917 resultados para document image processing


Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To investigate the relationship between divine proportion and facial esthetics in frontal photographs as well as whether any of the 4 ratios for manipulation provide more favorable facial esthetics. MATERIAL AND METHODS: The sample comprised 20 frontal photographs of Caucasian individuals (11 males and 9 females). The photographs were digitized and stored on a compact disk. A photometric analysis was created with 7 facial segments that were measured on Image Tool software and 4 ratios between 2 facial segments calculated using Microsoft Excel. This manipulation led to 5 different photographs of the same individual: one photograph with no manipulation and the others with 1 of the ratios manipulated in the Deformer 2.0 to very close or equal to 1.618. Thereafter, the 5 photographs of all individuals were evaluated by 12 examiners. The examiners selected those photographs that were esthetically more pleasant. CONCLUSION: After evaluation, a chi-square test revealed a relationship between divine proportion and facial esthetics. Among the ratios selected, R1 and R2 provided more favorable facial esthetics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the clinical behavior of 2 pit and fissure sealants through clinical/computerized evaluation. METHOD AND MATERIALS: Occlusal sealants were placed on maxillary and mandibular first and second premolars according to a split-mouth design. All premolars were sealed with either Concise (3M Espe) or Prisma Shield (Caulk/Dentsply) sealant agents. A hematoxylin-based staining solution was applied on the occlusal surface 7 days, 18 months, 36 months, and 11 years after occlusal sealing to allow checking of the sealant material on the surface. At each analysis time all occlusal surfaces were photographed, and the photographs corresponding to each time period were analyzed with SigmaScan 4.0 Software. The alterations of the sealed area of each sealant were analyzed with the software and recorded. Next, the measurements of the areas were tabulated and analyzed according to each period. Analysis of variance (ANOVA), with parts subdivided into time, and the t test, with a significance level of 5%, were used. RESULTS: The greatest sealed area was maintained by the sealant Concise. However, over the course of 11 years, all sealants began to show the same level of alteration in sealed area. CONCLUSION: The sealing materials showed alteration in sealed area over time, but they were efficient in controlling caries lesion formation on premolar pits and fissures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work the color dependence of resin composites with the background color was evaluated. The objective was to measure since what thickness the color of the sample stops being influenced by the color of the background over which the resin is placed and the methodology used in experiment was based in analyzing the contrast of digital images of the sample over a black background. The results shown that since 0.8 mm the images contrast becomes almost constant; it prove that since this thickness the color of resin composite depends on the optical resin properties only. The experiment was repeated under three conditions of luminosity to evaluate the influence of it on the image contrast and the results obtained were identical.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper discusses two pitch detection algorithms (PDA) for simple audio signals which are based on zero-cross rate (ZCR) and autocorrelation function (ACF). As it is well known, pitch detection methods based on ZCR and ACF are widely used in signal processing. This work shows some features and problems in using these methods, as well as some improvements developed to increase their performance. © 2008 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Paraguay River is the main tributary of the Paraná River and has an extension of 1.693 km in Brazilian territory. The navigability conditions are very important for the regional economy because most of the central-west Brazilian agricultural and mineral production is transported by the Paraguay waterway. Increased sedimentation along the channel requires continuous dredging to waterway maintenance. Systematic bathymetric surveys are periodically carried out in order to check depth condition along the channel using echo-sounding devices. In this paper, digital image processing and geostatistical analysis methods were used to analyze the applicability of the ASTER sensor to estimate channel depths in a segment of the upper Paraguay River. The results were compared with field data in order to choose the band with better adjustment and to evaluate the standard deviation. Comparing the VNIR bands, the best fit was presented by the red wavelength (band 2; 0,63 - 0,69 μm), showing a good representation of the channel depths shallow than 1,7 m. Applying geostatistical methods, the model accuracy was enhanced from 43 cm to 36 cm and undesired components were slacked. It was concluded that the digital number of band 2, converted to bathymetry information allows a good estimation of river depths and channel morphology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes the development of a mechatronic system for a predictive maintenance grounded on wear particle analysis. The reckoning of wear particles containing in lubricating industrial oils brings the image acquisition system into being. The ISO 4406:1999 standard is a guide to establish the counting and evaluation processes of particles. The system applied to the acquisition and analysis of the data consists of a digital camera, a monocular microscope and an oil filtering system. A computational program was developed with the application of Visual Microsoft C++ in a way to detain the oil sample image from the microscope slide to the computer screen. Quantitative analyses of the wear debris particles bulk are exploited applying a graphical interface that was developed to render the image processing of the sample test. The implemented system has a reachable cost thus it can be applied for schooling goals and for bolstering laboratories of minor industries and medium size companies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Symmetry is one of the factors that contributes to facial harmony, and in oral rehabilitation it determines the success of esthetic treatment. Therefore, the aim of the present study was to analyze the axial symmetry between the bipupillar midline and maxillary central incisors midline of 102 dental students (both genders) distributed across five Brazilian dental schools. Materials and Methods: Students with no teeth missing and who had never been subjected to any dental treatment were selected. Photographs were taken with a Dental Eye III camera with a 100-mm macro objective and ratio of 1 : 10 from natural size, recorded on an Ektachrome ASA/ISO 100 film. The images were developed and applied to Microsoft Office Power Point 2007 software. The results were analyzed by analysis of variance and Student's t-test (= 0.05). Results: There was no significant correlation between bipupillar midline and the maxillary dental midline, irrespective of gender. Conclusion: No significant coincidence was observed between the interpupillary and dental midline. However, the interpupillar distance and its relationship with other anatomic structures may be used as a reference in treatment, but measurements must be assessed individually. CLINICAL SIGNIFICANCE Anatomic measurements and facial proportions can be helpful during the planning of esthetic oral rehabilitation. © 2009 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Soil use for the development of activities as agriculture and livestock has been causing great alterations in the environment, mainly when these are practiced intensively, disrespecting the fragility and aptitude of the natural resources. Therefore, it is essential that the planning of the agricultural activities is done, taking into consideration the several environmental criteria involved in the decision-making process. Thus, this study aimed to analyze the agricultural aptitude classes of lands from a watershed through geographical information system (GIS). The Arroio Ajuricaba watershed is located in the Municipality of Marechal Cândido Rondon - PR among the coordinates UTM 787309m E and 793892m E; 7275026m N and 7281310m N, in the Spindle 21, presenting an area of 1681ha. Soil maps, in semi detail scale, was the digital cartographic base used. The results allowed to conclude that 42.41% of the basin presented a good aptitude for farming in handling level of high technology (handling level C), regular aptitude for B, and restricted aptitude for A [class 1(a)bC] and that 12% of the area had regular aptitude for farming in the three handling levels (class 1abc). The watershed lands (14.24%) presented regular aptitude for farming in handling level C, restricted aptitude for B, and inapt for A [class of aptitude 2(b)c]; 15.85% presented good aptitude for planted pasture (class 4P) and 12.21% were considered without aptitude for agricultural use (class 6). We can say that 71.94% of the lands has aptitude for farming, although they present different degrees of limitations that request different treatments for its conservation.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this paper is to introduce a new approach for edge detection in grey shaded images. The proposed approach is based on the fuzzy number theory. The idea is to deal with the uncertainties concerning the grey shades making up the image and, thus, calculate the appropriateness of the pixels in relation to a homogeneous region around them. The pixels not belonging to the region are then classified as border pixels. The results have shown that the technique is simple, computationally efficient and with good results when compared with both the traditional border detectors and the fuzzy edge detectors. Copyright © 2009, Inderscience Publishers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study on several components of intervertebral joints is essential to understand the spine's degenerative mechanisms and to assess the best method for their treatment. For such study it is necessary to know the mechanical properties of the isolated intervertebral disc (ID) mechanical properties and, it is necessary to evaluate its stresses and strains. In order to assess the ID displacements, a fine, U-shaped blade was developed, over which two extensometers connected in a Wheatstone bridge were placed. The device was then tested on porcine spine ID, where compression loads were applied and the extremities displacements of the blade coupled to the intervertebral disc were measured. Stress/strain diagram, both on the compression and on the decompression phases, evidencing the non-linear nature of such relationship. With the experiment, it was possible to obtain approximate values of the longitudinal elasticity module (E) of the disc material and of the Poisson coefficient (n ). After several tests, E results are compatible with those obtained by others studies, with very simple and low-cost device. This experiments can be used for obtained others mechanical properties of isolated ID with precision and accuracy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a novel, fast and accurate appearance-based method for infrared face recognition. By introducing the Optimum-Path Forest classifier, our objective is to get good recognition rates and effectively reduce the computational effort. The feature extraction procedure is carried out by PCA, and the results are compared to two other well known supervised learning classifiers; Artificial Neural Networks and Support Vector Machines. The achieved performance asserts the promise of the proposed framework. ©2009 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.