978 resultados para diagnostic fluorescent PCR
Resumo:
Conflicting results have been reported on the detection of paramyxovirus transcripts in Paget's disease, and a possible explanation is differences in the sensitivity of RT-PCR methods for detecting virus. In a blinded study, we found no evidence to suggest that laboratories that failed to detect viral transcripts had less sensitive RT-PCR assays, and we did not detect measles or distemper transcripts in Paget's samples using the most sensitive assays evaluated.
Introduction: There is conflicting evidence on the possible role of persistent paramyxovirus infection in Paget's disease of bone (PDB). Some workers have detected measles virus (MV) or canine distemper virus (CDV) transcripts in cells and tissues from patients with PDB, but others have failed to confirm this finding. A possible explanation might be differences in the sensitivity of RT-PCR methods for detecting virus. Here we performed a blinded comparison of the sensitivity of different RT-PCR-based techniques for MV and CDV detection in different laboratories and used the most sensitive assays to screen for evidence of viral transcripts in bone and blood samples derived from patients with PDB.
Materials and Methods: Participating laboratories analyzed samples spiked with known amounts of MV and CDV transcripts and control samples that did not contain viral nucleic acids. All analyses were performed on a blinded basis.
Results: The limit of detection for CDV was 1000 viral transcripts in three laboratories (Aberdeen, Belfast, and Liverpool) and 10,000 transcripts in another laboratory (Manchester). The limit of detection for MV was 16 transcripts in one laboratory (NIBSC), 1000 transcripts in two laboratories (Aberdeen and Belfast), and 10,000 transcripts in two laboratories (Liverpool and Manchester). An assay previously used by a U.S.-based group to detect MV transcripts in PDB had a sensitivity of 1000 transcripts. One laboratory (Manchester) detected CDV transcripts in a negative control and in two samples that had been spiked with MV. None of the other laboratories had false-positive results for MV or CDV, and no evidence of viral transcripts was found on analysis of 12 PDB samples using the most sensitive RT-PCR assays for MV and CDV.
Conclusions: We found that RT-PCR assays used by different laboratories differed in their sensitivity to detect CDV and MV transcripts but found no evidence to suggest that laboratories that previously failed to detect viral transcripts had less sensitive RT-PCR assays than those that detected viral transcripts. False-positive results were observed with one laboratory, and we failed to detect paramyxovirus transcripts in PDB samples using the most sensitive assays evaluated. Our results show that failure of some laboratories to detect viral transcripts is unlikely to be caused by problems with assay sensitivity and highlight the fact that contamination can be an issue when searching for pathogens by sensitive RT-PCR-based techniques.
The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry
Resumo:
PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.
Resumo:
PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD
Resumo:
PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.
Resumo:
Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. © 2007 American Academy of Ophthalmology.
Resumo:
Purpose: To compare the diagnostic abilities of the standard bracketing strategy (BR) and a fast strategy, the tendency-oriented perimetry (TOP). Methods: Seventy-seven controls and 91 eyes from patients with glaucoma were analyzed with the strategies TOP and BR. Sensitivity (Se), specificity (Sp), the area under the receiver operating characteristic (ROC) curve (AC) and the optimum cutoff value (CO) were calculated for the visual field indices mean defect (MD), the square root of the loss variance (sLV) and the number of pathological points (NPP). Results: In the glaucoma group, the mean MD value using TOP and BR was 7.5 and 8.3 dB, respectively. The mean sLV value using TOP and BR was 5.0 and 5.3 dB, respectively. Indices provided by TOP had higher ROC values than the ones provided by BR. Using TOP, the index with the best diagnostic ability was sLV (Sp = 94.8, Se = 90.1, AC = 0.966, CO = 2.5 dB), followed by NPP and MD. Using BR, the best results were obtained for MD (Sp = 92.2, Se = 81.3, AC = 0.900, CO = 2.5 dB) followed by sLV and NPP. Conclusions: A fast strategy, TOP, had superior diagnostic ability than the standard BR. Although TOP provided lower LV values than BR, the diagnostic ability of this index was higher than that of the conventional strategy. Copyright © 2005 S. Karger AG.
Resumo:
Aim: To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. Methods: The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. Results: A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Conclusion: Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.
Resumo:
This study presents a solid-phase PCR (SP-PCR) for rapid detection, identification, and sub-typing of various Salmonella species, the major food-borne cause of salmonellosis. The target DNA is firstly amplified with PCR primers (one primer is labeled with fluorophores) in the liquid phase. Simultaneously on the solid phase, the amplified PCR amplicons interact with the nested DNA probes immobilized on the solid substrate as an array. If the immobilized probes match the sequence of the DNA templates they are extended by the polymerase and serve as template for the second strand elongation primed by the liquid phase primer thus generating new templates for the SP-PCR. After the reaction, PCR products labeled with fluorophores remain attached to the substrate and can be visualized directly by fluorescence readout devices. Using this method, S. enteritidis, S. typhimurium and S. dublin can be detected at the same time. The method offers several advantages over conventional multiplex PCR: less competition between different primer pairs thus increasing multiplexing capability, only single wavelength optical readout needed for the multiplexing detection, and less time-consuming owing to reduction of the post-PCR gel electrophoresis. The method will be useful for development of point-of-care devices for rapid detection and identification of Salmonella spp. A solid-phase PCR for rapid detection and identification of S. enteritidis, S. typhimurium and S. dublin is developed. The method offers advantages such as better multiplexing capability, only single wavelength optical readout needed, and less time-consuming.
Resumo:
This paper reports a surface modification of epoxy-based negative photoresist SU-8 for reducing its autofluorescence while enhancing its biofunctionality. By covalently depositing a thin layer of 20 nm Au nanoparticles (AuNPs) onto the SU-8 surface, we found that the AuNPs-coated SU-8 surface is much less fluorescent than the untreated SU-8. Moreover, DNA probes can easily be immobilized on the Au surface and are thermally stable over a wide range of temperature. These improvements will benefit bioanalytical applications such as DNA hybridization and solid-phase PCR (SP-PCR).
Resumo:
During recent years, the increasing knowledge of genetic and physiological changes in polycythemia vera (PV) and of different types of congenital erythrocytosis has led to fundamental changes in recommendations for the diagnostic approach to patients with erythrocytosis. Although widely accepted for adult patients this approach may not be appropriate with regard to children and adolescents affected by erythrocytosis. The "congenital erythrocytosis" working group established within the framework of the MPN&MPNr-EuroNet (COST action BM0902) addressed this question in a consensus finding process and developed a specific algorithm for the diagnosis of erythrocytosis in childhood and adolescence which is presented here. Pediatr Blood Cancer 2013;9999:XX-XX. © 2013 Wiley Periodicals, Inc.