954 resultados para cooling chip for handheld electronic devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connecting different devices in many situations; however, this is often impractical, and sometimes impossible in outdoors situations. The aim of this paper is to describe a wireless system for outdoor use, allowing synchronization of different types of - potentially embedded and moving - devices. In this system, each synchronization device is composed of: (i) a GPS receiver (used as time reference), (ii) a radio transmitter, and (iii) a microcontroller. These components are used to provide synchronized trigger signals at the desired frequency to the measurement device connected. The synchronization devices communicate wirelessly, are very lightweight, battery-operated and thus very easy to set up. They are adaptable to every measurement device equipped with either trigger input or recording channel. The accuracy of the system was validated using an oscilloscope. The mean synchronization error was found to be 0.39 μs and pulses are generated with an accuracy of <2 μs. The system provides synchronization accuracy about two orders of magnitude better than commonly used post-processing methods, and does not suffer from any drift in trigger generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computerized handheld procedure is presented in this paper. It is intended as a database complementary tool, to enhance prospective risk analysis in the field of occupational health. The Pendragon forms software (version 3.2) has been used to implement acquisition procedures on Personal Digital Assistants (PDAs) and to transfer data to a computer in an MS-Access format. The data acquisition strategy proposed relies on the risk assessment method practiced at the Institute of Occupational Health Sciences (IST). It involves the use of a systematic hazard list and semi-quantitative risk assessment scales. A set of 7 modular forms has been developed to cover the basic need of field audits. Despite the minor drawbacks observed, the results obtained so far show that handhelds are adequate to support field risk assessment and follow-up activities. Further improvements must still be made in order to increase the tool effectiveness and field adequacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report for the scientific sojourn at the James Cook University, Australia, between June to December 2007. Free convection in enclosed spaces is found widely in natural and industrial systems. It is a topic of primary interest because in many systems it provides the largest resistance to the heat transfer in comparison with other heat transfer modes. In such systems the convection is driven by a density gradient within the fluid, which, usually, is produced by a temperature difference between the fluid and surrounding walls. In the oil industry, the oil, which has High Prandtl, usually is stored and transported in large tanks at temperatures high enough to keep its viscosity and, thus the pumping requirements, to a reasonable level. A temperature difference between the fluid and the walls of the container may give rise to the unsteady buoyancy force and hence the unsteady natural convection. In the initial period of cooling the natural convection regime dominates over the conduction contribution. As the oil cools down it typically becomes more viscous and this increase of viscosity inhibits the convection. At this point the oil viscosity becomes very large and unloading of the tank becomes very difficult. For this reason it is of primary interest to be able to predict the cooling rate of the oil. The general objective of this work is to develop and validate a simulation tool able to predict the cooling rates of high Prandtl fluid considering the variable viscosity effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els sistemes dʼatenció mèdica en situacions de pèrdues humanes massives necessiten classificar un número molt elevat de víctimes en un temps limitat i amb pocs recursos disponibles. Els mètodes clàssics es basen en una etiqueta de triatge de paper on el personal dʼemergències anota lʼestat del pacient juntament amb una quantitat reduïda dʼinformació. En aquest projecte descrivim lʼanàlisi, disseny i implementació dʼinterfícies gràfiques per dispositius mòbils pel protocol de triatge START, per ser utilitzades pels equips dʼemergència. Els components del projecte inclouen un dispositiu portàtil Nokia N810 amb connexió GPS, i IDBlue, un lector dʼetiquetes RFID per Bluetooth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RNA polymerase III (Pol III) occurs in two versions, one containing the POLR3G subunit and the other the closely related POLR3GL subunit. It is not clear whether these two Pol III forms have the same function, in particular whether they recognize the same target genes. We show that the POLR3G and POLR3GL genes arose from a DNA-based gene duplication, probably in a common ancestor of vertebrates. POLR3G- as well as POLR3GL-containing Pol III are present in cultured cell lines and in normal mouse liver, although the relative amounts of the two forms vary, with the POLR3G-containing Pol III relatively more abundant in dividing cells. Genome-wide chromatin immunoprecipitations followed by high-throughput sequencing (ChIP-seq) reveal that both forms of Pol III occupy the same target genes, in very constant proportions within one cell line, suggesting that the two forms of Pol III have a similar function with regard to specificity for target genes. In contrast, the POLR3G promoter-not the POLR3GL promoter-binds the transcription factor MYC, as do all other promoters of genes encoding Pol III subunits. Thus, the POLR3G/POLR3GL duplication did not lead to neo-functionalization of the gene product (at least with regard to target gene specificity) but rather to neo-functionalization of the transcription units, which acquired different mechanisms of regulation, thus likely affording greater regulation potential to the cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plant growth is strongly influenced by the presence of neighbors that compete for light resources. In response to vegetational shading shade-intolerant plants such as Arabidopsis display a suite of developmental responses known as the shade-avoidance syndrome (SAS). The phytochrome B (phyB) photoreceptor is the major light sensor to mediate this adaptive response. Control of the SAS occurs in part with phyB, which controls protein abundance of phytochrome-interacting factors 4 and 5 (PIF4 and PIF5) directly. The shade-avoidance response also requires rapid biosynthesis of auxin and its transport to promote elongation growth. The identification of genome-wide PIF5-binding sites during shade avoidance revealed that this bHLH transcription factor regulates the expression of a subset of previously identified SAS genes. Moreover our study suggests that PIF4 and PIF5 regulate elongation growth by controlling directly the expression of genes that code for auxin biosynthesis and auxin signaling components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Nuclear Factor I (NFI) family of DNA binding proteins (also called CCAAT box transcription factors or CTF) is involved in both DNA replication and gene expression regulation. Using chromatin immuno-precipitation and high throughput sequencing (ChIP-Seq), we performed a genome-wide mapping of NFI DNA binding sites in primary mouse embryonic fibroblasts. RESULTS: We found that in vivo and in vitro NFI DNA binding specificities are indistinguishable, as in vivo ChIP-Seq NFI binding sites matched predictions based on previously established position weight matrix models of its in vitro binding specificity. Combining ChIP-Seq with mRNA profiling data, we found that NFI preferentially associates with highly expressed genes that it up-regulates, while binding sites were under-represented at expressed but unregulated genes. Genomic binding also correlated with markers of transcribed genes such as histone modifications H3K4me3 and H3K36me3, even outside of annotated transcribed loci, implying NFI in the control of the deposition of these modifications. Positional correlation between + and - strand ChIP-Seq tags revealed that, in contrast to other transcription factors, NFI associates with a nucleosomal length of cleavage-resistant DNA, suggesting an interaction with positioned nucleosomes. In addition, NFI binding prominently occurred at boundaries displaying discontinuities in histone modifications specific of expressed and silent chromatin, such as loci submitted to parental allele-specific imprinted expression. CONCLUSIONS: Our data thus suggest that NFI nucleosomal interaction may contribute to the partitioning of distinct chromatin domains and to epigenetic gene expression regulation.NFI ChIP-Seq and input control DNA data were deposited at Gene Expression Omnibus (GEO) repository under accession number GSE15844. Gene expression microarray data for mouse embryonic fibroblasts are on GEO accession number GSE15871.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: The difficulty of identifying the ownership of lost dentures when found is a common and expensive problem in long term care facilities (LTCFs) and hospitals. PURPOSE: The purpose of this study was to evaluate the reliability of using radiofrequency identification (RFID) in the identification of dentures for LTCF residents after 3 and 6 months. MATERIAL AND METHODS: Thirty-eight residents of 2 LTCFs in Switzerland agreed to participate after providing informed consent. The tag was programmed with the family and first names of the participants and then inserted in the dentures. After placement of the tag, the information was read. A second and third assessment to review the functioning of the tag occurred at 3 and 6 months, and defective tags (if present) were reported and replaced. The data were analyzed with descriptive statistics. RESULTS: At the 3-month assessment of 34 residents (63 tags) 1 tag was unreadable and 62 tags (98.2%) were operational. At 6 months, the tags of 27 of the enrolled residents (50 tags) were available for review. No examined tag was defective at this time period. CONCLUSIONS: Within the limits of this study (number of patients, 6-month time span) RFID appears to be a reliable method of tracking and identifying dentures, with only 1 of 65 devices being unreadable at 3 months and 100% of 50 initially placed tags being readable at the end of the trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY : Eukaryotic DNA interacts with the nuclear proteins using non-covalent ionic interactions. Proteins can recognize specific nucleotide sequences based on the sterical interactions with the DNA and these specific protein-DNA interactions are the basis for many nuclear processes, e.g. gene transcription, chromosomal replication, and recombination. New technology termed ChIP-Seq has been recently developed for the analysis of protein-DNA interactions on a whole genome scale and it is based on immunoprecipitation of chromatin and high-throughput DNA sequencing procedure. ChIP-Seq is a novel technique with a great potential to replace older techniques for mapping of protein-DNA interactions. In this thesis, we bring some new insights into the ChIP-Seq data analysis. First, we point out to some common and so far unknown artifacts of the method. Sequence tag distribution in the genome does not follow uniform distribution and we have found extreme hot-spots of tag accumulation over specific loci in the human and mouse genomes. These artifactual sequence tags accumulations will create false peaks in every ChIP-Seq dataset and we propose different filtering methods to reduce the number of false positives. Next, we propose random sampling as a powerful analytical tool in the ChIP-Seq data analysis that could be used to infer biological knowledge from the massive ChIP-Seq datasets. We created unbiased random sampling algorithm and we used this methodology to reveal some of the important biological properties of Nuclear Factor I DNA binding proteins. Finally, by analyzing the ChIP-Seq data in detail, we revealed that Nuclear Factor I transcription factors mainly act as activators of transcription, and that they are associated with specific chromatin modifications that are markers of open chromatin. We speculate that NFI factors only interact with the DNA wrapped around the nucleosome. We also found multiple loci that indicate possible chromatin barrier activity of NFI proteins, which could suggest the use of NFI binding sequences as chromatin insulators in biotechnology applications. RESUME : L'ADN des eucaryotes interagit avec les protéines nucléaires par des interactions noncovalentes ioniques. Les protéines peuvent reconnaître les séquences nucléotidiques spécifiques basées sur l'interaction stérique avec l'ADN, et des interactions spécifiques contrôlent de nombreux processus nucléaire, p.ex. transcription du gène, la réplication chromosomique, et la recombinaison. Une nouvelle technologie appelée ChIP-Seq a été récemment développée pour l'analyse des interactions protéine-ADN à l'échelle du génome entier et cette approche est basée sur l'immuno-précipitation de la chromatine et sur la procédure de séquençage de l'ADN à haut débit. La nouvelle approche ChIP-Seq a donc un fort potentiel pour remplacer les anciennes techniques de cartographie des interactions protéine-ADN. Dans cette thèse, nous apportons de nouvelles perspectives dans l'analyse des données ChIP-Seq. Tout d'abord, nous avons identifié des artefacts très communs associés à cette méthode qui étaient jusqu'à présent insoupçonnés. La distribution des séquences dans le génome ne suit pas une distribution uniforme et nous avons constaté des positions extrêmes d'accumulation de séquence à des régions spécifiques, des génomes humains et de la souris. Ces accumulations des séquences artéfactuelles créera de faux pics dans toutes les données ChIP-Seq, et nous proposons différentes méthodes de filtrage pour réduire le nombre de faux positifs. Ensuite, nous proposons un nouvel échantillonnage aléatoire comme un outil puissant d'analyse des données ChIP-Seq, ce qui pourraient augmenter l'acquisition de connaissances biologiques à partir des données ChIP-Seq. Nous avons créé un algorithme d'échantillonnage aléatoire et nous avons utilisé cette méthode pour révéler certaines des propriétés biologiques importantes de protéines liant à l'ADN nommés Facteur Nucléaire I (NFI). Enfin, en analysant en détail les données de ChIP-Seq pour la famille de facteurs de transcription nommés Facteur Nucléaire I, nous avons révélé que ces protéines agissent principalement comme des activateurs de transcription, et qu'elles sont associées à des modifications de la chromatine spécifiques qui sont des marqueurs de la chromatine ouverte. Nous pensons que lés facteurs NFI interagir uniquement avec l'ADN enroulé autour du nucléosome. Nous avons également constaté plusieurs régions génomiques qui indiquent une éventuelle activité de barrière chromatinienne des protéines NFI, ce qui pourrait suggérer l'utilisation de séquences de liaison NFI comme séquences isolatrices dans des applications de la biotechnologie.