918 resultados para coefficient of discharge
Resumo:
Background: British government policy for older people focuses on a vision of active ageing and independent living. In the face of diminishing personal capacities, the use of appropriate home-based technology (HBT) devices could potentially meet a wide range of needs and consequently improve many aspects of older people's quality of life such as physical health, psychosocial well-being, social relationships, and their physical or living environment. This study aimed to examine the use of HBT devices and the correlation between use of such devices and quality of life among older people living in extra-care housing (ECH). Methods: A structured questionnaire was administered for this study. Using purposive sampling 160 older people living in extra-care housing schemes were selected from 23 schemes in England. A face-to-face interview was conducted in each participant's living unit. In order to measure quality of life, the SEIQoL-Adapted and CASP-19 were used. Results: Although most basic appliances and emergency call systems were used in the living units, communally provided facilities such as personal computers, washing machines, and assisted bathing equipment in the schemes were not well utilised. Multiple regression analysis adjusted for confounders including age, sex, marital status, living arrangement and mobility use indicated a coefficient of 1.17 with 95% CI (0.05, 2.29) and p = 0.04 [SEIQoL-Adapted] and 2.83 with 95% CI (1.17, 4.50) and p = 0.001 [CASP-19]. Conclusions: The findings of the present study will be value to those who are developing new form of specialised housing for older people with functional limitations and, in particular, guiding investments in technological aids. The results of the present study also indicate that the home is an essential site for developing residential technologies.
Resumo:
OBJECTIVES: To develop a method for objective assessment of fine motor timing variability in Parkinson’s disease (PD) patients, using digital spiral data gathered by a touch screen device. BACKGROUND: A retrospective analysis was conducted on data from 105 subjects including65 patients with advanced PD (group A), 15 intermediate patients experiencing motor fluctuations (group I), 15 early stage patients (group S), and 10 healthy elderly subjects (HE) were examined. The subjects were asked to perform repeated upper limb motor tasks by tracing a pre-drawn Archimedes spiral as shown on the screen of the device. The spiral tracing test was performed using an ergonomic pen stylus, using dominant hand. The test was repeated three times per test occasion and the subjects were instructed to complete it within 10 seconds. Digital spiral data including stylus position (x-ycoordinates) and timestamps (milliseconds) were collected and used in subsequent analysis. The total number of observations with the test battery were as follows: Swedish group (n=10079), Italian I group (n=822), Italian S group (n = 811), and HE (n=299). METHODS: The raw spiral data were processed with three data processing methods. To quantify motor timing variability during spiral drawing tasks Approximate Entropy (APEN) method was applied on digitized spiral data. APEN is designed to capture the amount of irregularity or complexity in time series. APEN requires determination of two parameters, namely, the window size and similarity measure. In our work and after experimentation, window size was set to 4 and similarity measure to 0.2 (20% of the standard deviation of the time series). The final score obtained by APEN was normalized by total drawing completion time and used in subsequent analysis. The score generated by this method is hence on denoted APEN. In addition, two more methods were applied on digital spiral data and their scores were used in subsequent analysis. The first method was based on Digital Wavelet Transform and Principal Component Analysis and generated a score representing spiral drawing impairment. The score generated by this method is hence on denoted WAV. The second method was based on standard deviation of frequency filtered drawing velocity. The score generated by this method is hence on denoted SDDV. Linear mixed-effects (LME) models were used to evaluate mean differences of the spiral scores of the three methods across the four subject groups. Test-retest reliability of the three scores was assessed after taking mean of the three possible correlations (Spearman’s rank coefficients) between the three test trials. Internal consistency of the methods was assessed by calculating correlations between their scores. RESULTS: When comparing mean spiral scores between the four subject groups, the APEN scores were different between HE subjects and three patient groups (P=0.626 for S group with 9.9% mean value difference, P=0.089 for I group with 30.2%, and P=0.0019 for A group with 44.1%). However, there were no significant differences in mean scores of the other two methods, except for the WAV between the HE and A groups (P<0.001). WAV and SDDV were highly and significantly correlated to each other with a coefficient of 0.69. However, APEN was not correlated to neither WAV nor SDDV with coefficients of 0.11 and 0.12, respectively. Test-retest reliability coefficients of the three scores were as follows: APEN (0.9), WAV(0.83) and SD-DV (0.55). CONCLUSIONS: The results show that the digital spiral analysis-based objective APEN measure is able to significantly differentiate the healthy subjects from patients at advanced level. In contrast to the other two methods (WAV and SDDV) that are designed to quantify dyskinesias (over-medications), this method can be useful for characterizing Off symptoms in PD. The APEN was not correlated to none of the other two methods indicating that it measures a different construct of upper limb motor function in PD patients than WAV and SDDV. The APEN also had a better test-retest reliability indicating that it is more stable and consistent over time than WAV and SDDV.
Resumo:
The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.
Resumo:
The aim of this project is to provide an explanation for recently obtained binding constants for two similar guest molecules, NDMG and N-MAP, with a p-sulfonatocalix[6]arene host in ammonium acetate buffer. This work was done primarily using pressure perturbation calorimetry, which is a technique that determines the coefficient of thermal expansion, α, which is in turn related to the solute molecule's effect on the order of the surrounding water molecules. A series of experiments were designed to test the effects of suspected confounding variables on the validity of PPC data. PPC was then used to study NDMG and N-MAP in ammonium acetate buffer. NDMG exhibited a minimum in α as function of temperature, while N-MAP did not. This difference was theorized to be due to the formation of an intramolecular hydrogen bond in monocationic NDMG that would lower the heat capacity of the molecule and better distribute the molecule's charge. Computational work and nuclear magnetic resonance spectroscopy confirmed that monocationic, ring-closed NDMG has less concentrated charge and more constrained motion than monocationic, ring-open NDMG. This evidence supports the theory that monocationic NDMG forms an intramolecular hydrogen bond and that this may be responsible for the minimum in α. This difference may explain the differences in binding constants between NDMG and N-MAP.
Resumo:
The reliable evaluation of the flood forecasting is a crucial problem for assessing flood risk and consequent damages. Different hydrological models (distributed, semi-distributed or lumped) have been proposed in order to deal with this issue. The choice of the proper model structure has been investigated by many authors and it is one of the main sources of uncertainty for a correct evaluation of the outflow hydrograph. In addition, the recent increasing of data availability makes possible to update hydrological models as response of real-time observations. For these reasons, the aim of this work it is to evaluate the effect of different structure of a semi-distributed hydrological model in the assimilation of distributed uncertain discharge observations. The study was applied to the Bacchiglione catchment, located in Italy. The first methodological step was to divide the basin in different sub-basins according to topographic characteristics. Secondly, two different structures of the semi-distributed hydrological model were implemented in order to estimate the outflow hydrograph. Then, synthetic observations of uncertain value of discharge were generated, as a function of the observed and simulated value of flow at the basin outlet, and assimilated in the semi-distributed models using a Kalman Filter. Finally, different spatial patterns of sensors location were assumed to update the model state as response of the uncertain discharge observations. The results of this work pointed out that, overall, the assimilation of uncertain observations can improve the hydrologic model performance. In particular, it was found that the model structure is an important factor, of difficult characterization, since can induce different forecasts in terms of outflow discharge. This study is partly supported by the FP7 EU Project WeSenseIt.
Resumo:
The initial endogenous growth models emphasized the importance of externaI effects in explaining sustainable growth across time. Empirically, this hypothesis can be confirmed if the coefficient of physical capital per hour is unity in the aggregate production function. Although cross-section results concur with theory, previous estimates using time series data rejected this hypothesis, showing a small coefficient far from unity. It seems that the problem lies not with the theory but with the techniques employed, which are unable to capture low frequency movements in high frequency data. This paper uses cointegration - a technique designed to capture the existence of long-run relationships in multivariate time series - to test the externalities hypothesis of endogenous growth. The results confirm the theory' and conform to previous cross-section estimates. We show that there is long-run proportionality between output per hour and a measure of capital per hour. U sing this result, we confmn the hypothesis that the implied Solow residual can be explained by government expenditures on infra-structure, which suggests a supply side role for government affecting productivity and a decrease on the extent that the Solow residual explains the variation of output.
Resumo:
In this paper I claim that, in a long-run perspective, measurements of income inequality, under any of the usual inequality measures used in the literature, are upward biased. The reason is that such measurements are cross-sectional by nature and, therefore, do not take into consideration the turnover in the job market which, in the long run, equalizes within-group (e.g., same-education groups) inequalities. Using a job-search model, I show how to derive the within-group invariant-distribution Gini coefficient of income inequality, how to calculate the size of the bias and how to organize the data in arder to solve the problem. Two examples are provided to illustrate the argument.
Resumo:
A lógica fuzzy admite infinitos valores lógicos intermediários entre o falso e o verdadeiro. Com esse princípio, foi elaborado neste trabalho um sistema baseado em regras fuzzy, que indicam o índice de massa corporal de animais ruminantes com objetivo de obter o melhor momento para o abate. O sistema fuzzy desenvolvido teve como entradas as variáveis massa e altura, e a saída um novo índice de massa corporal, denominado Índice de Massa Corporal Fuzzy (IMC Fuzzy), que poderá servir como um sistema de detecção do momento de abate de bovinos, comparando-os entre si através das variáveis linguísticas )Muito BaixaM, ,BaixaB, ,MédiaM, ,AltaA e Muito AltaM. Para a demonstração e aplicação da utilização deste sistema fuzzy, foi feita uma análise de 147 vacas da raça Nelore, determinando os valores do IMC Fuzzy para cada animal e indicando a situação de massa corpórea de todo o rebanho. A validação realizada do sistema foi baseado em uma análise estatística, utilizando o coeficiente de correlação de Pearson 0,923, representando alta correlação positiva e indicando que o método proposto está adequado. Desta forma, o presente método possibilita a avaliação do rebanho, comparando cada animal do rebanho com seus pares do grupo, fornecendo desta forma um método quantitativo de tomada de decisão para o pecuarista. Também é possível concluir que o presente trabalho estabeleceu um método computacional baseado na lógica fuzzy capaz de imitar parte do raciocínio humano e interpretar o índice de massa corporal de qualquer tipo de espécie bovina e em qualquer região do País.
Resumo:
Many efforts are currently oriented toward extracting more information from ocean color than the chlorophyll a concentration. Among biological parameters potentially accessible from space, estimates of phytoplankton cell size and light absorption by colored detrital matter (CDM) would lead to an indirect assessment of major components of the organic carbon pool in the ocean, which would benefit oceanic carbon budget models. We present here 2 procedures to retrieve simultaneously from ocean color measurements in a limited number of bands, magnitudes, and spectral shapes for both light absorption by CDM and phytoplankton, along with a size parameter for phytoplankton. The performance of the 2 procedures was evaluated using different data sets that correspond to increasing uncertainties: ( 1) measured absorption coefficients of phytoplankton, particulate detritus, and colored dissolved organic matter ( CDOM) and measured chlorophyll a concentrations and ( 2) SeaWiFS upwelling radiance measurements and chlorophyll a concentrations estimated from global algorithms. In situ data were acquired during 3 cruises, differing by their relative proportions in CDM and phytoplankton, over a continental shelf off Brazil. No local information was introduced in either procedure, to make them more generally applicable. Over the study area, the absorption coefficient of CDM at 443 nm was retrieved from SeaWiFS radiances with a relative root mean square error (RMSE) of 33%, and phytoplankton light absorption coefficients in SeaWiFS bands ( from 412 to 510 nm) were retrieved with RMSEs between 28% and 33%. These results are comparable to or better than those obtained by 3 published models. In addition, a size parameter of phytoplankton and the spectral slope of CDM absorption were retrieved with RMSEs of 17% and 22%, respectively. If these methods are applied at a regional scale, the performances could be substantially improved by locally tuning some empirical relationships.
Resumo:
Concanavalin A-Sandwich ELISA (Con A-S-ELISA) was developed for the detection of infectious bronchitis virus (IBV) or chicken specific anti-viral antibodies. The antigen detection limit for the Con A-S-ELISA was 10(5,1) EID50/mL. Three homologous and four heterologous IBV strains were similarly detected. This assay was highly effective in detecting the virus after infected tissue homogenates were passed once in embryonated chicken eggs, showing a good agreement with virus isolation technique. The Con A-S-ELISA was also used to measure anti-IBV chicken antibodies and showed a high coefficient of correlation (r = 0.85) and an agreement of k = 0.80 with the commercially available Indirect-ELISA. The relative sensitivity and specificity between these two tests were, respectively, 92.86% and 95.65% with an accuracy of 93.39%. Thus, the Con A-S-ELISA proved to be able to detect alternatively homologous and heterologous IBV strains or specific chicken anti-IBV antibodies, using the Con A as capture reagent of this assay.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study reported compared coefficients of apparent digestibility (CAD) obtained by total collection (TC) and by chromic oxide (Cr2O3) determined by visible absorption spectrometry (VIS) and flame atomic absorption spectrophotometry (FAAS). These quantification methods were also investigated to assess their precision. Nineteen adult dogs housed in individual digestibility cages were fed three commercial diets, each test including five or seven animals. The experiment was carried out in a completely randomized design with three among-subjects factors (foods) and three within-subject factors (methods), and the dogs were the experimental unit. Estimated CAD for all dietary components in the three diets by either chromium quantification methods did not differ and showed fair agreement with TC results (P > 0.05). Coefficients of chromic oxide recoveries in feces were 1.06 +/- 0.044 and 1.01 +/- 0.045 for VIS and FAAS, respectively, values significantly different (P < 0.05), indicating better recovery for FAAS. Significant differences (P<0.05) were found in the mean concentration of Cr2O3 for diets and feces (17 +/- 0.6 and 19 +/- 0.8g/kg for VIS and FAAS, respectively). Coefficient of variation for FAAS was 1.69% and 1.77% for VIS, which did not differ significantly (P > 0.05). Pearson's correlation coefficient (r=0.99; P < 0.01) indicated positive and significant association among the results for VIS and FASS, indicating reasonable precision and agreement of chromic oxide contents determined by these methods. Therefore, FAAS and VIS can be used successfully to determine Cr2O3 in dog foods and feces. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Maize gluten feed (MGF) is a co-product of wet milling of maize, and is composed of structures that remain after most starch, gluten and germ has been extracted from the grain. Although currently used in dog foods, its digestibility and energy values have not been documented. Two techniques were used to determine nutrient digestibility of MGF for dog foods. Both techniques used extruded diets fed to Beagle dogs, with six replicates per diet. The first study used a difference method in which 300 g/kg of a reference diet was replaced by MGF. Based on the difference method, the coefficient of total tract apparent digestibility (CTTAD) of MGF was 0.53 for dry matter (DM), 0.69 for crude protein (CP), 0.74 for fat, 0.99 for starch, and 0.55 for gross energy (GE). The calculated metabolizable energy (ME) of MGF was 7.99 MJ/kg (as-fed). The second study used a regression method and included a basal diet and a basal diet with 70, 140 and 210 g MGF/kg of diet (as a substitute for maize starch). Maize gluten feed inclusion resulted in a linear reduction of CTTAD of DM (R(2)=0.99; P<0.001), CP (R(2)=0.95; P=0.002), fat (R(2)=0.87; P=0.009). starch (R(2)=0.81; P<0.001), and GE (R(2)=0.99; P<0.001). Faecal production increased linearly from 56 g to 107 g/dog/d (R(2)=0.99; P<0.001), with a linear reduction of faecal DM (R(2)=0.99: P<0.001) and a linear increase in faecal lactic acid concentration (P<0.02). Both urine (R(2)=0.77; P=0.029) and faeces (R(2)=0.92: P=0.019) showed a linear reduction in pH. Results of ingredient MAD obtained by the regression and difference methods were close (6% or less of variation) for CP, fat, and starch, and also for ME content (1.4% higher for the difference method), but the two methods disagreed on calculated CTTAD of DM and organic matter. The high dietary fiber content of MGF (382 g/kg) may explain the low digestibility of this ingredient. Maize gluten feed could be a useful ingredient for formulations designed to have low energy or reduce the urine pH of dogs. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.