996 resultados para agente comercial
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).
Resumo:
ABSTRACT. Introduction: an in vitro model was used to measure the hydraulic conductance in human dentin discs treated with oxalic acid for 15, 30 or 60 s maintaining the occlusive effect and measuring 7 and 14 days after application. Methods: 45 dentin discs measuring 1 mm thick were obtained from human third molars which were free of caries and in no occlusion; the samples were obtained from patients aged 16 to 30 years. Discs were sorted out into three study groups (n = 15) depending on the time of application of a commercial solution of oxalate-based dentin desensitizer (DD) (BisBlock®) which contains ˂ 5% oxalic acid of 1.5-1.8 pH: in group A the agent was applied for 15 s, in group B it was applied for 30 s, and in group C for 60 s. The hydraulic conductance of each disc was calculated after acid etching, which corresponds to the maximum permeability of discs (100%) after immediate application of oxalic acid, as well as seven and fourteen days of storage in saline solution. The statistical analysis was done with ANOVA test and post-hoc Games-Howell test. Results: 35,46 ± 23.41% in Group A, 36.34 ± 15.88% in Group B and 24.99 ± 14.99% in Group C, showing that the use of DD for 15, 30 or 60 s decreased permeability in a statistically significant manner (p <0.05). Conclusions: DD was effective in reducing hydraulic conductance regardless of application time, but this reduction was temporary only, since after seven days permeability returns to values close to those of baseline.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Post-Occupancy Evaluation of buildings considers user satisfaction, building pathologies and performance, as well as users interventions in the built environment. The possibility of identifying interventions regardless of the user could provide a significant gain in the efficiency of Post-Occupancy Evaluations. We foresee the application of Augmented Reality (AR) to improve the identification of renovations by overlapping the construction information model with an image of the actual building. This article validates the use of AR on existing smartphone and tablet applications. This study proposes the incorporation of AR into the planning, execution and application of Post-Occupancy Evaluation. For the planning, this study proposes the development of a new research tool. With regards to the execution, this study examined the data collection conditions on site through the visualization of overlapping models. For the application, this study proposes displaying the results through the use of RA information layers. The transparency oft he RA model was used to allow comparison between the virtual model and the real model. The development and adaptation of the virtual model and the solution developed for the experiment of the RA proposal are presented and discussed. The experiment points to shortcomings that still make the proposed technological solution unfeasible.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.
Resumo:
Sabendo-se do potencial de toxicidade do mercúrio, mais especificamente de sua forma orgânica, o metilmercúrio (MeHg), faz-se necessária a busca por métodos analíticos eficientes e precisos para a determinação e especiação do metal. A técnica de difusão por gradiente em filmes finos (DGT) já vem sendo utilizada para tal fim de maneira eficiente tendo apresentado resultados satisfatórios em diversos estudos. Porém, a utilização de ligantes alternativos aos convencionais, que tornem a aplicação da técnica menos custosa em termos laborais e financeiros, faz-se importante para um monitoramento constante e eficiente do metilmercúrio no ambiente. No presente trabalho buscou-se avaliar o potencial da levedura Saccharomyces cerevisiae imobilizada em agarose em combinação com a poliacrilamida como agente difusivo para determinação seletiva de MeHg. Os resultados demonstraram-se positivo, com um coeficiente de difusão médio de 7,03 ± 0,77 x 10-6 cm2 s-1. Os resultados demonstraram também baixa influencia do pH, força iônica e outros íons na retenção do analito pelos dispositivos. As recuperações de Hg2+ demonstraram-se insatisfatórios, evidenciando a seletividade dos dispositivos
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.
Resumo:
This study aimed to evaluate the clinical effectiveness of two bleaching agents without changing the whitening gel during the clinic session 1X45minutos. 10 patients were selected according to the criteria of inclusion and exclusion and upper arch of the patients were divided into two quadrants (n: 10), G1: gel clareador Clàriant Office (hidrogênio35 Angellus) peroxide% (PH) in superior right side (LD) and the gel WhitenessHp Blue (FGM) PH 35% on the superior left side (LE. 2 clinical sessions were accomplished, 45 minutes each, with an interval of one week between sessions. At first the bleaching treatment patients received prophylaxis, molding to guide measurement of color with condensation silicon and the color evaluation through the apparel spectrophotometer VITA Easyshade (Vita Zhanfabrik, Alemanhã). 14 days after the end of the bleaching treatment was performed the measurement final color of the teeth. The patients reported sensitivity in scale 0-4. The result showed that through T Test comparing quadrants presented no statistical differences (p>0,05) in relation to coloration and dental sensibility. It can be concluded that the materials evaluated are effective for bleaching vital teeth with low tooth sensibility.
Resumo:
Chemical composition, proteolysis and functional properties of commercial Mozzarella cheese with reduced fat content found in the market of Londrina – PR were evaluated. The cheeses were analyzed for chemical composition, meltability, free oil formation, and the indexes of extension and depth of proteolysis during 30, 45 and 60 days of storage at 5°C. The samples showed no significant difference in chemical composition. The fat content of all samples complied with current legislation regarding the minimum percentage (25%) of fat reduction. Among the three brands tested, the cheeses of brand C showed the highest depth index of proteolysis. In all chesses, the meltability has increased during storage period. The, the brand C had significantly higher (p <0.05) free oil content when compared to other brands tested.