992 resultados para Yersinia pestis F1 antigen detection
Resumo:
A digoxigenin-labeled probe was produced from the Pasteur virus strain for the detection of the rabies virus N gene. The probe hybridization was performed from amplified N gene obtained by reverse transcription polymerase chain reaction and the results by RT-PCR and hybridization showed 100% agreement. The hybridization, when carried out in products amplified by RT-PCR, increases the sensitivity of this technique even more and confers specificity to the diagnosis. The technique described in this work will be useful in rabies diagnosis laboratories, once the cost is compatible with traditional rabies diagnostic techniques.
Resumo:
This dissertation presents an approach aimed at three-dimensional perception’s obstacle detection on all-terrain robots. Given the huge amount of acquired information, the adversities such environments present to an autonomous system and the swiftness, thus required, from each of its navigation decisions, it becomes imperative that the 3-D perceptional system to be able to map obstacles and passageways in the most swift and detailed manner. In this document, a hybrid approach is presented bringing the best of several methods together, combining the lightness of lesser meticulous analyses with the detail brought by more thorough ones. Realizing the former, a terrain’s slope mapping system upon a low resolute volumetric representation of the surrounding occupancy. For the latter’s detailed evaluation, two novel metrics were conceived to discriminate the little depth discrepancies found in between range scanner’s beam distance measurements. The hybrid solution resulting from the conjunction of these two representations provides a reliable answer to traversability mapping and a robust discrimination of penetrable vegetation from that constituting real obstructions. Two distinct robotic platforms offered the possibility to test the hybrid approach on very different applications: a boat, under an European project, the ECHORD Riverwatch, and a terrestrial four-wheeled robot for a national project, the Introsys Robot.
Resumo:
RESUMO:RESUMO: Nos últimos anos a ultrassonografia emergiu como um instrumento importante no diagnóstico da patologia torácica. O progresso tecnológico possibilitou a conceção de novos equipamentos como a ecoendoscopia brônquica radial e linear. Verificou-se, igualmente, o aparecimento de indicações para a realização de ecografia transtorácica. Uma das principais doenças impulsionadoras da técnica ultrassonográfica no tórax foi o cancro do pulmão, primeira causa de morte oncológica a nível mundial. A aplicabilidade e conhecimento do papel dos ultrassons no âmbito do diagnóstico e estadiamento do cancro do pulmão não se encontram esgotados, persistindo focos de controvérsia e dúvida científica que se pretendem esclarecer. A presente tese foi organizada em cinco capítulos: o primeiro abordou de forma geral e introdutória o estado da arte referente à ultrassonografia torácica, cancro do pulmão e a sua conjugação; o segundo destacou os principais objetivos; o terceiro sumarizou a metodologia utilizada; o quarto englobou os cinco estudos publicados, descritos subsequentemente, e o quinto incluiu uma discussão concisa, as principais conclusões e perspetivas futuras. O primeiro estudo avaliou a rentabilidade diagnóstica, segurança e curva de aprendizagem num coorte de 179 doentes submetidos a ecoendoscopia brônquica linear. De acordo com as indicações para este procedimento os doentes foram subdivididos em três grupos: (1) diagnóstico, (2) diagnóstico e estadiamento e (3) estadiamento. Para o primeiro, segundo e terceiro grupos a sensibilidade da ecoendoscopia foi 86.1%, 86.7% e 95% respetivamente e a precisão técnica foi 87.5%, 93.1% e 97.7% respetivamente. O treino originou um aumento progressivo do número de locais puncionados por doente, com menor duração e sem complicações, comprovando a eficácia e segurança do método quando realizado na população Portuguesa por broncologistas com experiência. O segundo estudo foi conduzido para averiguar a eficácia e custo da ecoendoscopia brônquica linear realizada através da via aérea e/ou esófago no diagnóstico de lesões sugestivas de neoplasia do pulmão, após ineficácia das técnicas convencionais. Nos doentes incluídos prospetivamente alcançou-se um diagnóstico definitivo em 106 casos (87.6%). A sensibilidade global para o diagnóstico de cancro do pulmão foi 89.8%, a especificidade foi 100%, o valor preditivo positivo foi 100%, o valor preditivo negativo foi 20% e a precisão foi 90.1%. Esta estratégia ultrassonográfica abrangente evitou intervenções cirúrgicas diagnósticas em doentes anteriormente submetidos a broncoscopia flexível ou punção aspirativa transtorácica guiada por tomografia computorizada, proporcionando uma redução significativa dos custos. No terceiro estudo investigou-se a viabilidade e papel da conjugação da ecoendoscopia brônquica linear com técnicas moleculares na avaliação de antigénios tumorais e padrões de metastização ganglionar em doentes com cancro do pulmão de não-pequenas células (CPNPC). Os marcadores citoqueratina 19 (CK-19), antigénio carcinoembrionário (CEA), molécula de adesão celular epitelial (EPCAM), sialyl-Lewis X e CD44 foram determinados nos aspirados ganglionares de 33 doentes com neoplasia e 17 controlos 10 Ultrassonografia através de citometria de fluxo (CF) e reação em cadeia da polimerase em tempo real (RTPCR). Os doentes com CPNPC possuíam um compartimento celular epitelial significativamente aumentado e com marcação superior de CK-19 comparativamente ao grupo de controlo. O compartimento imune foi também analisado nestas amostras e revelou-se alterado no CPNPC com aumento da população de monócitos e diminuição das subpopulações linfocitárias. Os transcriptos de CK-19, CEA e EPCAM estavam elevados nos doentes com cancro do pulmão, identificando-se uma correlação positiva entre estes marcadores e o tamanho da lesão primária. Concluiu-se que a identificação de CK-19, CEA e EPCAM nas amostras obtidas por ecoendoscopia e avaliadas por CF e RTPCR foi viável, podendo auxiliar na deteção de metástases ganglionares no CPNPC. O quarto estudo envolveu a combinação da ecoendoscopia brônquica radial com uma criosonda para o diagnóstico de lesões pulmonares sólidas periféricas. Foi determinada a viabilidade, rentabilidade diagnóstica, tamanho das amostras e segurança do método. Lesões inferiores a 40mm foram localizadas por ultrassonografia sendo os doentes randomizados para a realização de biópsias transbrônquicas com pinça seguidas por criosonda ou vice-versa. Nos 39 casos incluídos a lesão foi visualizada pela minisonda em 31 doentes (79.5%), com 80.6% de prevalência de cancro do pulmão na amostra. A rentabilidade diagnóstica da pinça de biópsia foi 61.3% e da criosonda foi 74.2%. O tamanho do tecido adquirido pelas criobiópsias foi significativamente maior do que o alcançado por pinça (11.17mm2 vs. 4.69mm2, p<0.001). Ocorreu um único caso de hemorragia moderada, controlada através de medidas conservadoras. As biópsias transbrônquicas com criosonda sob orientação de ecoendoscopia radial foram seguras e eficazes na obtenção de amostras histológicas. O quinto estudo determinou o valor diagnóstico da ecografia transtorácica na identificação de malignidade em doentes com derrame pleural de natureza indeterminada. Foram examinados de forma prospetiva 154 doentes. Os resultados clínicos e radiológicos de cada caso foram ocultados ao executante do exame que gerou imagens estáticas e vídeos ultrassonográficos relevantes. Estes foram posteriormente visualizados, sendo as suas características classificadas por revisores independentes e comparadas com o diagnóstico definitivo. Em 66 casos o diagnóstico foi de derrame pleural maligno (68.2% com cancro do pulmão) e em 67 de derrame benigno. A ecografia torácica obteve 80.3% de sensibilidade, 83.6% de especificidade, 81.2% de valor preditivo negativo e 82.8% de valor preditivo positivo na deteção de malignidade. A nodularidade pleural ou diafragmática, espessamento pleural superior a 10mm e sinal de swirling foram significativamente diferentes (p<0.001) sendo sugestivos de derrame maligno. A existência de nodularidade pleural e ausência de broncograma aéreo ecográfico aumentaram a probabilidade de malignidade (OR 29.0 e OR 10.4, respetivamente). A ecografia transtorácica permitiu diferenciar derrame pleural maligno do benigno. A existência de nódulos pleurais constituiu o fator discriminador mais relevante. Em conclusão, os resultados desta tese possibilitam uma melhor compreensão do papel da ecoendoscopia brônquica (linear e radial) e ecografia transtorácica no diagnóstico e estadiamento do cancro do pulmão, com implicações e aplicabilidade na prática clínica.------------- ABSTRACT: In recent years ultrasonography has emerged as an important instrument in the diagnosis of thoracic diseases. Technological progress has enabled the design of new equipment such as radial and linear endobronchial ultrasound. In addition, indications for transthoracic echography were established. One of the main diseases responsible for the progression of chest sonography was lung cancer, the leading cause of cancer mortality worldwide. The applicability and knowledge of the role of ultrasonography in diagnosing and staging lung cancer is not depleted, persisting foci of controversy and scientific doubt that we intend to elucidate. The present thesis was organized into five chapters: the first included a general introduction regarding chest ultrasound, lung cancer and their combination; the second emphasized the main objectives; the third summarized the methodology used; the fourth encompassed the five published studies, subsequently described, and the fifth included a concise discussion, the main findings and future perspectives. The first study evaluated the diagnostic yield, safety and learning curve in a cohort of 179 patients submitted to linear endobronchial ultrasound. According to procedure indications, the patients were divided into three groups: (1) diagnosis, (2) diagnosis and staging, and (3) staging. For the first, second and third groups, endobronchial ultrasound sensitivity was 86.1%, 86.7% and 95% respectively and accuracy was 87.5%, 93.1% and 97.7% respectively. Practise led to an increase number of punctured sites per patient, in a shorter period of time and without complications, proving the safety and efficacy of the method when performed in the Portuguese population by expert echoscopists. The second study was conducted to determine the efficacy and cost of linear endobronchial ultrasound performed through the airway and/or oesophagus for diagnosis of lesions suggestive of lung cancer, after failure of conventional techniques. Of the patients prospectively enrolled a definitive diagnosis was reached in 106 cases (87.6%). The overall sensitivity for the diagnosis of lung cancer was 89.8%, specificity was 100%, positive predictive value was 100%, negative predictive value was 20% and accuracy was 90.1%. In conclusion, this global ultrasonographic strategy avoided diagnostic surgical procedures in patients that had undergone flexible bronchoscopy or computed tomography-guided transthoracic needle aspiration, providing a significant cost reduction. In the third study, the feasibility and role of linear endobronchial ultrasound combined with molecular techniques in the evaluation of tumour antigens and patterns of lymph node metastasis in patients with non-small cell lung cancer (NSCLC) was investigated. Cytokeratin 19 (CK-19), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EPCAM), sialyl Lewis-X and CD44 were determined in lymph node aspirates of 33 lung cancer patients and 17 controls, using flow cytometry (FC) and reverse transcription polymerase chain reaction (RT-PCR). In patients with NSCLC the epithelial cell compartment was significantly increased nd showed brighter CK-19 staining, compared to the control group. In NSCLC patients the immune compartment revealed an increased monocyte population and decreased lymphocyte subsets. The transcripts of CK- 19, CEA and EPCAM were higher in lung cancer patients and a positive correlation between these markers and the size of the primary lesion was also found. We concluded that the identification of CK-19, CEA and EPCAM in endobronchial ultrasound samples, using RT-PCR and FC was feasible and might aid in the detection of NSCLC lymph node metastases. The fourth study involved the combination of the radial endobronchial ultrasound with the cryoprobe for diagnosing solid peripheral lung lesions. We determined the feasibility, diagnostic yield, sample size and safety of the method. Lesions less than 40mm were located by ultrasound and forceps or cryobiopsies were performed in a randomized order. Of the 39 cases included, the lesion could be visualized by the miniprobe in 31 patients (79.5%), and lung cancer prevalence was 80.6%. The diagnostic yield of the biopsy forceps was 61.3% and for the cryobiopsy was 74.2 %. Cryobiopsies were significantly larger than forceps biopsies (11.17mm2 vs. 4.69mm2, p<0.001). There was only one case of moderate bleeding that was controlled by conservative measures. Transbronchial cryobiopsies under radial endobronchial ultrasound guidance were safe and effective in obtaining histological samples. The fifth study determined the diagnostic value of transthoracic sonography in predicting malignancy in patients with an undiagnosed pleural effusion. One hundred and fifty four patients were prospectively scanned. Relevant ultrasound images and videos were generated by an operator blinded to clinical and radiological results. These were subsequently visualized, its characteristics classified by independent reviewers and compared to the final diagnosis. A malignant pleural effusion was diagnosed in 66 cases (68.2 % with lung cancer) and a benign effusion in 67 cases. Thoracic ultrasound had a sensitivity of 80.3 %, specificity of 83.6%, negative predictive value of 81.2 % and positive predictive value of 82.8% to detect malignancy. The presence of pleural or diaphragmatic nodularity, pleural thickening greater than 10mm and swirling signal were significantly different (p<0.001 ), being suggestive of malignant effusion. The existence of pleural nodularity and absence of lung air bronchogram were more likely to indicate malignancy (OR 29.0 and OR 10.4, respectively). Transthoracic ultrasonography permits the distinction between malignant and benign pleural effusions. Pleural nodules were the most relevant feature. In conclusion, the results of this thesis provide a better understanding of the role of endobronchial ultrasound (linear and radial) and transthoracic sonography in lung cancer diagnosis and staging, with direct implications and applicability in clinical practice.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
Eradication of code smells is often pointed out as a way to improve readability, extensibility and design in existing software. However, code smell detection remains time consuming and error-prone, partly due to the inherent subjectivity of the detection processes presently available. In view of mitigating the subjectivity problem, this dissertation presents a tool that automates a technique for the detection and assessment of code smells in Java source code, developed as an Eclipse plugin. The technique is based upon a Binary Logistic Regression model that uses complexity metrics as independent variables and is calibrated by expert‟s knowledge. An overview of the technique is provided, the tool is described and validated by an example case study.
Resumo:
Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.
Resumo:
The objective of the present study was to estimate the frequency of infection by Cryptosporidium spp and other intestinal parasites in dehydrated children with gastroenteritis who were admitted to a pediatric hospital. Stool examinations from 218 children were performed. Cryptosporidium spp was identified in eighteen out of 193 stool samples (9.3%) subjected to safranin-methylene blue staining. Giardia lamblia was detected in ten out of 213 (4.7%) samples examined via the direct or Ritchie methods. Other parasites identified were Ascaris lumbricoides (4.2%), Blastocystis hominis (1.4%), Entamoeba coli (0.9%), Entamoeba histolytica/Entamoeba dispar (0.5%), Endolimax nana (0.5%), Trichuris trichiura (0.5%) and Enterobius vermicularis (0.5%).
Resumo:
Total antigen from Leishmania (Leishmania) amazonensis and isolates from the Leishmania braziliensis complex, along with their respective antigenic fractions obtained by affinity chromatography on concanavalin-A-Sepharose and jacalin-agarose columns evaluated using immunoenzymatic ELISA assay. For this, serum samples from 229 patients were used, grouped as American tegmental leishmaniasis (nº=58), visceral leishmaniasis (nº=28), Chagas disease (nº=49), malaria (nº=32), tuberculosis (nº=13) and healthy volunteers (nº=49). Samples from American tegmentary leishmaniasis showed higher reactivity with antigens isolated from the Leishmania braziliensis complex than with antigens from Leishmania amazonensis (p<0.001). ELISA assays showed a sensitivity range from 60% to 95% with antigens isolated from the Leishmania braziliensis complex. There was marked nonspecific reactivity among serum samples with the use of antigenic fractions binding with concanavalin-A and jacalin from both Leishmania complexes, in comparison with other antigens (p<0.001). The results presented in this study suggest that the use of homologous antigens increases the efficiency of anti-Leishmania immunoglobulin detection, which may be very valuable for diagnostic purposes.
Resumo:
Detection of anti-toxoplasma IgM antibodies has frequently been used as a serological marker for diagnosing recently acquired toxoplasmosis. However, the persistence of these antibodies in some patients has complicated the interpretation of serological results when toxoplasmosis is suspected. The purpose of the present study was to evaluate the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, to establish a profile for acute recent infection in a single serum sample and confirm the presence of residual IgM antibodies obtained in automated assays. When we evaluated the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii by means of immunoblot, we observed phase-specific reactivity, i.e. cases of acute recent toxoplasmosis presented low avidity and cases of non-acute recent toxoplasmosis presented high avidity towards the 30kDa protein fraction, which probably corresponds to the SAG-1 surface antigen. Our results suggest that the avidity of IgG antibodies against excreted/secreted antigens of Toxoplasma gondii is an important immunological marker for distinguishing between recent infections and for determining the presence of residual IgM antibodies obtained from automated assays.
Resumo:
Part of this thesis will be published in the following: Gomes, B.C., Santos, B. 2015. Methods for studying microRNAs expression and their targets in formalin-fixed, paraffin-embedded (FFPE) breast cancer tissues. In Methods in Molecular Biology: Cancer Drug Resistance (Rueff, J. & Rodrigues, A.S. eds), Springer Protocols.
Resumo:
Diagnosis of human herpesvirus-7 active infection in transplant patients has proved difficult, because this virus is ubiquitous and can cause persistent infections in the host. The significance of viral DNA detected in leukocytes by PCR is unclear and cross-reaction in serological tests may occur. This study aimed to evaluate nested-PCR to detect human herpesvirus-7 active infection in liver transplant recipients compared to healthy individuals. human herpesvirus-7 nested-PCR was performed on leukocytes and sera of 53 healthy volunteers and sera of 29 liver transplant recipients. In healthy volunteers, human herpesvirus-7 was detected in 28.3% of leukocytes and 0% of serum. human herpesvirus-7 was detected in sera of 48.2% of the liver transplant recipients. Nested-PCR on DNA extracted from leukocytes detected latent infection and the study suggests that nested-PCR performed on serum could be useful to detect human herpesvirus-7 active infection in liver transplant recipients.
Resumo:
The main objective of this thesis was the development of a gold nanoparticle-based methodology for detection of DNA adducts as biomarkers, to try and overcome existing drawbacks in currently employed techniques. For this objective to be achieved, the experimental work was divided in three components: sample preparation, method of detection and development of a model for exposure to acrylamide. Different techniques were employed and combined for de-complexation and purification of DNA samples (including ultrasonic energy, nuclease digestion and chromatography), resulting in a complete protocol for sample treatment, prior to detection. The detection of alkylated nucleotides using gold nanoparticles was performed by two distinct methodologies: mass spectrometry and colorimetric detection. In mass spectrometry, gold nanoparticles were employed for laser desorption/ionisation instead of the organic matrix. Identification of nucleotides was possible by fingerprint, however no specific mass signals were denoted when using gold nanoparticles to analyse biological samples. An alternate method using the colorimetric properties of gold nanoparticles was employed for detection. This method inspired in the non-cross-linking assay allowed the identification of glycidamide-guanine adducts and DNA adducts generated in vitro. For the development of a model of exposure, two different aquatic organisms were studies: a goldfish and a mussel. Organisms were exposed to waterborne acrylamide, after which mortality was recorded and effect concentrations were estimated. In goldfish, both genotoxicity and metabolic alterations were assessed and revealed dose-effect relationships of acrylamide. Histopathological alterations were verified primarily in pancreatic cells, but also in hepatocytes. Mussels showed higher effect concentrations than goldfish. Biomarkers of oxidative stress, biotransformation and neurotoxicity were analysed after prolonged exposure, showing mild oxidative stress in mussel cells, and induction of enzymes involved in detoxification of oxygen radicals. A qualitative histopathological screening revealed gonadotoxicity in female mussels, which may present some risk to population equilibrium.
Resumo:
This study analyses financial data using the result characterization of a self-organized neural network model. The goal was prototyping a tool that may help an economist or a market analyst to analyse stock market series. To reach this goal, the tool shows economic dependencies and statistics measures over stock market series. The neural network SOM (self-organizing maps) model was used to ex-tract behavioural patterns of the data analysed. Based on this model, it was de-veloped an application to analyse financial data. This application uses a portfo-lio of correlated markets or inverse-correlated markets as input. After the anal-ysis with SOM, the result is represented by micro clusters that are organized by its behaviour tendency. During the study appeared the need of a better analysis for SOM algo-rithm results. This problem was solved with a cluster solution technique, which groups the micro clusters from SOM U-Matrix analyses. The study showed that the correlation and inverse-correlation markets projects multiple clusters of data. These clusters represent multiple trend states that may be useful for technical professionals.
Resumo:
INTRODUCTION: Arenavirus hemorrhagic fever is a severe emerging disease. METHODS: Considering that the levels of antibodies against arenavirus in the Brazilian population are completely unknown, we have standardized an ELISA test for detecting IgG antibodies using a recombinant nucleoprotein from the Junin virus as the antigen. This protein was obtained by inserting the gene of the Junin virus nucleoprotein into the genome of Autographa californica nucleopolyhedrovirus, using the Bac-to-Bac baculovirus expression system. This recombinant baculovirus was used to infect S. frugiperda cells (SF9). RESULTS: The infection resulted in synthesis of high concentrations of recombinant protein. This protein was detected on 12.5% polyacrylamide gel and by means of Western blot. Using the standardized ELISA test, 343 samples from the population of Nova Xavantina were analyzed. We observed that 1.4% of the serum samples (five samples) presented antibody titers against arenavirus. CONCLUSIONS: These results show the population studied may present exposure to arenavirus infection.