966 resultados para Urban heat island
Resumo:
This chapter reports on a study that reveals the essence of participation in urban spaces by ten children who live with various physical conditions: Muscular Dystrophy, Cerebral Palsy, and Autoimmune Rheumatic Diseases. These conditions affect muscle and movement differently resulting in diverse ways in which children move through space (personal mobility). The children at the time of the research were 9-12 years of age residing in South-east Queensland, Australia. The approach and methods selected for this study, interpretive phenomenological inquiry and grounded theory, were chosen for their capacity to capture the complexity and multiple interactions of the child’s urban living. The confronting and poignant accounts by children and their families of their experiences produced a new way of understanding the concept of participation, as a ‘journey of becoming involved.’ Their accounts of performing everyday routines (e.g. leaving home, getting in and out of the car, and entering places) in urban spaces (neighbourhood streets, schools, open spaces, shopping centres, and hospitals) revealed differences in the way settings were experienced. These differences were associated with the interplay between the body, space and context. Where interplays were problematic, explicit decisions about children’s involvement were made. These decisions were described in terms of ‘avoid going’, ‘pick and choose’, ‘discontinue’, ‘accept’, or ‘contest.’ What these decisions mean is some spaces are avoided, some journeys are discontinued, and some barriers encountered in journeys are normalised as everyday experiences, i.e. ‘tolerable discrimination’. These actions resulted in experiences of non-participation or partial–tokenistic participation. The key substantive contribution of the research lies in the identification of points in children’s journeys that shape participation experience. These points identify where future interventions in policy, programming and design can be made to make real and sustaining changes to lives of children and their families in geographies crucial to urban living.
Resumo:
This paper offers numerical modelling of a waste heat recovery system. A thin layer of metal foam is attached to a cold plate to absorb heat from hot gases leaving the system. The heat transferred from the exhaust gas is then transferred to a cold liquid flowing in a secondary loop. Two different foam PPI (Pores Per Inch) values are examined over a range of fluid velocities. Numerical results are then compared to both experimental data and theoretical results available in the literature. Challenges in getting the simulation results to match those of the experiments are addressed and discussed in detail. In particular, interface boundary conditions specified between a porous layer and a fluid layer are investigated. While physically one expects much lower fluid velocity in the pores compared to that of free flow, capturing this sharp gradient at the interface can add to the difficulties of numerical simulation. The existing models in the literature are modified by considering the pressure gradient inside and outside the foam. Comparisons against the numerical modelling are presented. Finally, based on experimentally-validated numerical results, thermo-hydraulic performance of foam heat exchangers as waste heat recovery units is discussed with the main goal of reducing the excess pressure drop and maximising the amount of heat that can be recovered from the hot gas stream.
Resumo:
Prosperity and environmental sustainability of cities are inextricably linked. Cities can only maintain their prosperity when environmental and social objectives are fully integrated with economic goals for the purpose of a sustainable urban development. Sustainability assessment helps policy-makers decide what actions they should and should not take in an attempt to make our cities more sustainable. There are numerous models available for measuring and evaluating urban sustainability, and they focus their analysis on a specific scale—i.e., micro, mezzo, or macro. In most cases these results are inadequate for the other scales, though generating reliable results for that particular scale. The paper introduces a multiscalar urban sustainability approach by linking two sustainability assessment models evaluate sustainability performances in micro- and mezzo-levels and generate multiscalar results for the macro-level. The paper puts this approach into test in Gold Coast, Australia, and sheds light on the development of a more accurate sustainability analysis that may be interconnected with UN-Habitat’s City Prosperity Index.
Resumo:
A solar assisted heat pump is used for different applications, such as, water heating, drying and air conditioning. The unglazed evaporator-collector enables to absorb both solar energy and ambient energy due to low operating temperature. Three different systems are described: solar assisted heat pump system for hot water using an unglazed evaporator collector; solar assisted heat pump for hot water and drying, where evaporator collector and air collector are used; an integrated solar heat pump system making use of solar and ambient energy, and air-con waste heat. Unlike conventional collector, evaporator collector was found to have higher efficiency, 80% to 90%, and the coefficient of performance attained a value as high as 8.0. The integrated system leads to a reduction of global warming, as it uses solar energy, ambient energy and air-con waste heat.
Resumo:
The solar-assisted heat pump (SAHP) desalination, based on the Rankin cycle, operates in low temperature and utilizes both solar and ambient energy. An experimental SAHP desalination system has been constructed at the National University of Singapore, Singapore. The system consisted of two main sections: an SAHP and a water distillation section. Experiments were carried out under the different meteorological condition of Singapore and results showed that the system had a performance ratio close to 1.3. The heat pump has a coefficient of performance of about 8, with solar collector efficiencies of 80% and 60% for evaporator and liquid collectors, respectively. Economic analysis showed that at a production rate of 900 L/day and an evaporator collector area of around 70m2 will have a payback period of about 3.5 years.
Resumo:
Desalination is considered one of the most suitable areas for the utilization of solar energy, as there are many places in the world where abundant supply of solar energy is available and also there is a great demand for fresh water. An integrated solar heat pump desalination system has been developed at the National University of Singapore. The system also offers the opportunity of water heating and drying utilizing solar, ambient energy and waste heat from air conditioning system, which is conventionally dumped into the environment causing global warming. Desalination is carried out by making use of a single effect of Multi-Effect Distillation (MED) system. Within the desalination chamber, both fl ashing and evaporation of saline water take place. The maximum Coefficient of Performance (COP) of the heat pump system was around 5.8. In the integrated system, the maximum fresh water production rate was 9.6 l h−1 and a Performance Ratio (PR) of 1.2. For only desalination, the system has the potential to produce a maximum of 30 l h−1 of fresh water.
Resumo:
The low temperature operation of a heat pump makes it an excellent match for the use of solar energy. At the National University of Singapore, a solar assisted heat pump system has been designed, fabricated and installed to provide water heating and drying. The system also utilizes the air con waste heat, which would normally be released to atmosphere adding to global warming. Experimental results show that the twophase unglazed solar evaporator-collector, instead of losing energy to the ambient, gained a significant amount due to low operating temperature of the collector. As a result, the collector efficiency attains a value greater than 1, when conventional collector equations are used. With this evaporator-collector, the system can be operated even in the absence of solar irradiation. The waste heat was collected from an air-con system, which maintained a room at 20-22 oC. In the condenser side, water at 60 oC was produced at a rate of 3 liter/minute and the drying capacity was 2.2kg/hour. Maximum COP of the system was found to be about 5.5.
Resumo:
Singapore is located at the equator, with abundant supply of solar radiation, relatively high ambient temperature and relative humidity throughout the year. The meteorological conditions of Singapore are favourable for efficient operation of solar energy based systems. Solar assisted heat pump systems are built on the roof-top of National University of Singapore’s Faculty of Engineering. The objectives of this study include the design and performance evaluation of a solar assisted heat-pump system for water desalination, water heating and drying of clothes. Using MATLAB programming language, a 2-dimensional simulation model has been developed to conduct parametric studies on the system. The system shows good prospect to be implemented in both industrial and residential applications and would give new opportunities in replacing conventional energy sources with green renewable energy.
Resumo:
Chloroquine-resistant Plasmodium falciparum was highly prevalent in Hainan, China, in the 1970s. Twenty-five years after cessation of chloroquine therapy, the prevalence of P. falciparum wild-type Pfcrt alleles has risen to 36% (95% confidence interval, 22.1 to 52.4%). The diverse origins of wild-type alleles indicate that there was no genetic bottleneck caused by high chloroquine resistance.
Resumo:
The Japanese government initiated a series of regulatory reforms in the mid-1990s. The Japanese urban gas industry consists of various sized private and non-private firms. Numerous previous studies find that deregulation leads to productivity improvements. We extend the literature by analyzing deregulation, privatization, and other aspects of a regulated industry using unique firm level data. This study measures productivity to evaluate the effect of the deregulation reform. Using data from 205 firms from 1993 to 2004, we find that the deregulation effect differs depending on firm size. Competitive pressure contributes to advanced productivity. The deregulation of gas sales to commercial customers is the most important factor for advancing productivity. Copyright © 2013 by the IAEE. All rights reserved.
Resumo:
This thesis explored traffic characteristics at the aggregate level for area-wide traffic monitoring of large urban area. It focused on three aspects: understanding a macroscopic network performance under real-time traffic information provision, measuring traffic performance of a signalised arterial network using available data sets, and discussing network zoning for monitoring purposes in the case of Brisbane, Australia. This work presented the use of probe vehicle data for estimating traffic state variables, and illustrated dynamic features of regional traffic performance of Brisbane. The results confirmed the viability and effectiveness of area-wide traffic monitoring.
Resumo:
In view of the growing global demand for energy and concern expressed for environmental degradation, a clean and "free" energy source, such as solar energy, has been receiving greater attention in recent years for various applications using different techniques. The Direct Expansion Solar Assisted Heat Pump (DX-SAHP) principle is one of the most promising techniques as it makes use of both solar and ambient energy. As the system has capability to function at low temperatures, it has the potential to operate at night in the tropics. The system utilizes multi-effect distillation (MED) principle for the conversion of seawater to fresh water. An experimental setup of the DX-SAHP desalination system has been built at the Department of Mechanical Engineering, National University of Singapore (NUS). This system uses two types of flat-plate solar collectors. One is called evaporator-collector, where no glazing is used, and the efficiency varies between 80 and 90%. The other type of collector is single-glazed, where the maximum efficiency is about 60%, and it is used for feed water heating. For the heat pump cycle, refrigerant R134a is used. The present study provides a comprehensive analyses and performance evaluation of this system under different operating and meteorological conditions of Singapore. The Coefficient of Performance (COP) of the heat pump system reached a maximum value of 10. For a single effect of desalination, the system shows a Performance Ratio (PR) of around 1.3.
Resumo:
Urban public space in Australia and internationally, can be critically examined from a number of multidisciplinary standpoints, including human geography, urban design, planning, sociology, and public health. Viewing urban public space from a range of perspectives encourages different vantage points to emerge and questions around health, wellbeing and public space are increasingly topical and important in the broadest of terms, with public space being a key arena for physical activity, mental health, commercial, cultural and community life and the possibility of social inclusion. However, in the name of urban regeneration, programs of securitisation, ‘gentrification’ ‘creative’ and ‘smart’ city initiatives refashion public space as sites of selective inclusion and exclusion (Watson 2005; Gabrys 2014). In this context of monitoring and control procedures, in particular, children and young people’s use of space in parks, neighbourhoods, shopping malls and streets, is often viewed as a threat to social order, requiring various forms of remedial action, such as being ‘designed out’ of public space (Johnson 2014). Rarely are children and young people actively and respectfully brought into planning and governance processes and consequently many urban public spaces are essentially adult places, where control and ongoing surveillance are the key concerns (Freeman 2011, Dee 2013). There is also a political economy of public space discernable in cities like Brisbane, where ‘flagship’ infrastructure such as road tunnels take pride of place, while more humbly appointed pedestrian footpaths are often narrow, in a poor state of repair and a potential barrier to good health (Atkinson and Easthope 2009). The recent development of bikeways in Brisbane is a case in point, presenting both challenges and opportunities in being a valuable new form of public space heavily used by ‘commuter cyclists’ by day, but poorly lit and conceived, for a range of users at other times (Wyeth 2014). This paper concentrates on questions of social citizenship rights and discourses of health and wellbeing and suggests that cities, places and spaces and those who seek to use them, can be resilient in maintaining and extending democratic freedoms, calling surveillance, planning and governance systems to account (Smith 2014). The active inclusion of children and young people better informs the implementation of public policy around the design, build and governance of public space and also understandings of urban citizenship, leading to healthier, more inclusive, public space for all (Jacobs 1965).
Resumo:
Participation is a word frequently espoused in the literature of childhood and urban studies. It has also been made sacrosanct through the Convention on the Rights of the Child and other rights-based policy and programming. Despite this importance, what it means and how it is experienced in the everyday lives of children with diverse abilities is not well understood. This chapter provides insight into the everyday experiences of participation by ten children 9-12 years of age, who have diverse personal mobility from various physical conditions that affect muscle and movement differently, including: Muscular Dystrophy, Cerebral Palsy, and Autoimmune Rheumatic Diseases. The children participants live in the outer suburbs and inner regions of south-east Queensland, Australia. The chapter discusses a new way of understanding and theorising participation as a journey of becoming involved. This knowledge emerged through the children’s body-space-time routines (body ballets) and their descriptions of inhabiting urban space. This chapter also establishes how body-space-context interplays shape the experiences of becoming and being involved in everyday life, as well as the preconceptions of body embed in space which divide and constrain children and families actualisation of full and genuine participation.
Resumo:
The aim of this study was to elucidate the thermophysiological effects of wearing lightweight non-military overt and covert personal body armour (PBA) in a hot and humid environment. Eight healthy males walked on a treadmill for 120 min at 22% of their heart rate reserve in a climate chamber simulating 31 °C (60%RH) wearing either no armour (control), overt or covert PBA in addition to a security guard uniform, in a randomised controlled crossover design. No significant difference between conditions at the end of each trial was observed in core temperature, heart rate or skin temperature (P > 0.05). Covert PBA produced a significantly greater amount of body mass change (−1.81 ± 0.44%) compared to control (−1.07 ± 0.38%, P = 0.009) and overt conditions (−1.27 ± 0.44%, P = 0.025). Although a greater change in body mass was observed after the covert PBA trial; based on the physiological outcome measures recorded, the heat strain encountered while wearing lightweight, non-military overt or covert PBA was negligible compared to no PBA. Practitioner summary The wearing of bullet proof vests or body armour is a requirement of personnel engaged in a wide range of occupations including police, security, customs and even journalists in theatres of war. This randomised controlled crossover study is the first to examine the thermophysiological effects of wearing lightweight non-military overt and covert personal body armour (PBA) in a hot and humid environment. We conclude that the heat strain encountered while wearing both overt and covert lightweight, non-military PBA was negligible compared to no PBA.