974 resultados para Ultrafine Particles, Laser Printer, Indoor Air Quality, Aerosol Formation
Resumo:
Currently, there is increasing use of nanomaterials in the food industry thanks to the many advantages offered and make the products that contain them more competitive in the market. Their physicochemical properties often differ from those of bulk materials, which require specialized risk assessment. This should cover the risks to the health of workers and consumers as well as possible environmental risks. The risk assessment methods must go updating due to more widespread use of nanomaterials, especially now that are making their way down to consumer products. Today there is no specific legislation for nanomaterials, but there are several european dispositions and regulations that include them. This review gives an overview of the risk assessment and the existing current legislation regarding the use of nanotechnology in the food industry.
Resumo:
Die zunehmende Luftverschmutzung aufgrund des steigenden Energiebedarfs und Mobilitätsanspruchs der Bevölkerung, insbesondere in urbanen Gebieten, erhöht das Gefährdungspotential für die Gesundheit und verschlechtert so die Lebensqualität. Neben der Vermeidung von Emissionen toxischer Gase als mittel- und langfristig optimale Maßnahme zur Verbesserung der Luftqualität, stellt der Abbau emittierter Luftschadstoffe ein geeignetes und kurzfristig wirksames Mittel dar. Ein solcher Abbau kann durch Photokatalyse erzielt werden, allerdings nutzen Photokatalysatoren, die auf dem Halbleiter Titandioxid (TiO2) basieren, das solare Emissionsspektrum nur geringfüfig aus und sind in Innenräumen und anderen UV-schwachen Bereichen nicht wirksam. Um diese Nachteile zu überwinden, wurde ein Photokatalysator entwickelt und hergestellt, der aus TiO2 (P25) als UV-aktiver Photokatalysator und als Trägermaterial sowie einem seinerseits im Vis-Bereich photoaktiven Porphyrazin-Farbstoff als Beschichtung besteht. Die sterisch anspruchsvollen und in der Peripherie mit acht Bindungsmotiven für TiO2 versehenen Farbstoffmoleküle wurden zu diesem Zweck auf der Halbleiteroberfläche immobilisiert. Die so gebildeten Porphyrazin-Titandioxid-Hybride wurde ausführlich charakterisiert. Dabei wurden unter anderem die Bindung der Farbstoffe auf der Titandioxidoberfläche mittels Adsorptionsisothermen und die UV/Vis-spektroskopischen Eigenschaften des Hybridmaterials untersucht. Zur Bestimmung der photokatalytischen Aktivitäten der Einzelkomponenten und des Hybridmaterials wurden diese auf die Fähigkeit zur Bildung von Singulett-Sauerstoff, Wasserstoffperoxid und Hydroxylradikalen hin sowie in einem an die ISO-22197-1 angelehnten Verfahren auf die Fähigkeit zum Abbau von NO hin jeweils bei Bestrahlung in drei Wellenlängenbereichen (UV-Strahlung, blaues Licht und rotes Licht) geprüft. Darüber hinaus konnte die Aktivität des Hybridmaterials bei der Photodynamischen Inaktivierung (PDI) von Bakterien unter UV- und Rotlichtbestrahlung im Vergleich zum reinen Ttandioxid bestimmt werden. Die Charakterisierung des Hybridmaterials ergab, dass die Farbstoffmoleküle in einer neutralen Suspension nahezu irreversibel in einer monomolekularen Schicht mit einer Bindungsenergie von -41.43 kJ/mol an die Oberfläche gebunden sind und das Hybridmaterial mit hohen Extinktionskoeffizienten von bis zu 105 M-1cm-1 in großen Bereichen des UV/Vis-Spektrums Photonen absorbiert. Das Spektrum des Hybridmaterials setzt sich dabei additiv aus den beiden Einzelspektren zusammen. Die Auswirkungen der Charakterisierungsergebnisse auf die Bildung reaktiver Sauerstoffspezies wurden ausführlich diskutiert. Der Vergleich der Aktivitäten in Bezug auf die Bildung der reaktiven Sauerstoffspezies zeigte, dass die Aktivität des Hybridmaterials bis auf die bei der Bildung von Hydroxylradikalen unter UV-Bestrahlung in allen Versuchen deutlich höher war als die Aktivität des reinen Titandioxids. Im Gegensatz zu reinem Titandioxid erzeugte das Hybridmaterial in allen untersuchten Wellenlängenbereichen Mengen an Singulett-Sauerstoff, die photophysikalisch eindeutig detektierbar waren. Zur Erklärung und Deutung dieser Beobachtungen wurde eine differenzierte Diskussion geführt, die die Ergebnisse der Hybridpartikelcharakterisierung aufgreift und implementiert. Der Vergleich der NO-Abbaueffizienzen ergab bei allen Experimenten durchgängig deutlich höhere Werte für das Hybridmaterial. Zudem wurden durch das Hybridmaterial nachgewiesenermaßen wesentlich geringere Mengen des unerwünschten Nebenprodukts des Abbaus (NO2) gebildet. Im Zuge der Diskussion wurden verschiedene mögliche Mechanismen der „sauberen“ Oxidation zu Nitrat durch das Hybridmaterial vorgestellt. Untersuchungen zur Photodynamischen Inaktivierung verschiedener Bakterien ergaben, dass das Hybridmaterial neben einer zu P25 ähnlichen Aktivität unter UV-Bestrahlung, anders als P25, auch eine PDI verschiedener Bakterien unter Rotlichtbestrahlung erreicht.
Resumo:
The dataset contains aerosol ion concentrations and oxygen-17 excess data for samples collected during the Malaspina and Xue-Long cruises. This is the data used for the study "Isotopic constraints on the role of hypohalous acids in sulfate aerosol formation in the remote marine boundary layer" in ACPD by Chen et al., 2016.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
A consciencialização ambiental vem assumindo um papel preponderante na construção civil. Nesse sentido, o desenvolvimento de materiais sustentáveis e ecológicos é essencial para a satisfação de fabricantes e consumidores, respeitando diversos requisitos: níveis reduzidos de poluição e toxicidade, durabilidade dos materiais, possibilidade de reutilização e/ou reciclagem, a proveniência das matérias-primas e a possibilidade de contaminação do ar no interior dos edifícios. As declarações ambientais de produto (DAP) permitem informar o consumidor do desempenho ambiental dos materiais dos produtos. Assim, ao longo de todo o processo de fabrico são registados os consumos de recursos e emissões ambientais e, através da metodologia de avaliação de ciclo de vida, é quantificada a contribuição resultante para impactes ambientais. Esta dissertação visa analisar os possíveis impactes ambientais no decurso do processo de produção de um pavimento flutuante de cortiça, constituído por cortiça, High Density Fibreboard (HDF) e acabamento de superfície, denominado Artcomfort Floating NPC e elaborar de um relatório de suporte, que servirá de base para a DAP do pavimento Artcomfort Floating NPC do sistema do Institut Bauen und Umwelt (IBU). Esta dissertação inclui um relatório de fundo, para a avaliação do ciclo de vida do pavimento flutuante Artcomfort Floating NPC da empresa Amorim Revestimentos, que servirá de base para a elaboração da declaração ambiental de produto (DAP) do mesmo. Para tal, recorreu-se ao software SimaPro para análise dos impactes ambientais das várias fases do processo de fabrico do pavimento em estudo, sendo as fases consideradas, a produção da camada base de cortiça aglomerada, camada backing de cortiça aglomerada, montagem da sanduiche, placa pintada, placa acabada e corte e embalagem. A fase que tem maior contribuição para os impactes ambientais do processo de fabrico do produto, em todas as categorias de impacte analisadas, com exceção da depleção dos recursos abióticos sem combustíveis fósseis, foi a fase de montagem da sanduiche.
Resumo:
Esta dissertação centra-se na elaboração de uma proposta de matriz de indicadores de sustentabilidade a aplicar ao município de Estarreja. Apesar dos mais recentes desafios e requisitos em matéria de monitorização de planos, projectos e actividades com implicações sobre o ambiente e a sustentabilidade, o acompanhamento da evolução económica, social e ambiental, de uma forma integrada, pelo município tem sido escasso. A literatura da especialidade bem como diversas experiencias municipais nacionais e internacionais têm revelado que a adopção de sistemas de indicadores de sustentabilidade tem um grande potencial não apenas para avaliar o progresso dos municípios em direcção à sustentabilidade ambiental, mas também para induzir melhores formas de governação local. O principal objectivo desta dissertação é a construção de uma matriz de indicadores que avalie a sustentabilidade do município de Estarreja ao nível ambiental. A metodologia adoptada neste trabalho consiste em cinco fases, sendo a primeira fase, a revisão da literatura, através da análise de artigos científicos da especialidade. Na segunda fase é feito o enquadramento legislativo das responsabilidades de monitorização ambiental que cabem aos municípios portugueses. Numa terceira fase, desenvolve-se o levantamento e análise de indicadores sectoriais existentes, já recolhidos e tratados por instituições do Concelho de Estarreja. Na quarta fase procede-se à construção da matriz de indicadores de sustentabilidade, agregando os indicadores já recolhidos pelas iniciativas municipais a um novo conjunto de indicadores de sustentabilidade capazes de analisar a evolução do município no que respeita às pressões sobre o ambiente e sobre os níveis de qualidade ambiental. Na quinta fase são apresentadas as principais conclusões do trabalho e feitas recomendações para tornar exequível e eficiente a monitorização da matriz. O trabalho está organizado em cinco capítulos sendo estes coincidentes com as cinco fases da metodologia. A região de Estarreja tem implantado no seu concelho um dos maiores complexos industriais do país e, em consequência disso, tem vindo a sofrer ao longo dos anos o impacto das actividades industrial e urbana. O procedimento para a construção do sistema de indicadores, bem como a identificação dos eixos temáticos necessários para descrever o contexto que influencia a sustentabilidade do desenvolvimento local, teve por base outros sistemas de indicadores de sustentabilidade local e fornece uma ampla avaliação das características ambientais do município. As dimensões ambientais incluem água, gestão de resíduos, solos, ruído, protecção da natureza, biodiversidade, qualidade do ar, energia e espaços verdes e estão distribuídas por 60 indicadores. Entre estes, 32 já estão a ser monitorizados e 28 foram acrescentados no âmbito deste trabalho. A monitorização dos indicadores propostos não exige grande investimento em capital humano e financeiro, no entanto, constitui um desafio, uma vez que pressupõe a interacção, partilha de informação e transparência por parte das diferentes entidades e empresas municipais.
Resumo:
Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior
Resumo:
L’arbre en ville offre plusieurs bienfaits, et ce, même s’il est souvent confronté à des conditions de vie difficiles. Au cours des années, la foresterie urbaine a suscité plusieurs travaux de recherches. Ce projet visait à faire un recensement des publications scientifiques de recherche en foresterie urbaine, à faire l’état de la situation des municipalités en matière de foresterie urbaine et à identifier les besoins de recherche en foresterie urbaine des municipalités canadiennes de 5 000 habitants et plus. Le premier objectif a été réalisé en utilisant plusieurs bases de données d’articles scientifiques et des mots clefs en foresterie urbaine. Un sondage pancanadien a permis de réaliser les deux autres objectifs. Le recensement que nous avons effectué des publications en foresterie urbaine depuis 1800 a montré, comme pour les publications scientifiques en général, mais de façon encore plus marquée, un accroissement de leur nombre ces dernières années. Ce recensement a aussi permis de révéler que les préoccupations de recherche touchent surtout l’effet des arbres sur la santé humaine et la qualité de l’air. L’identification des besoins de recherche réalisée auprès des responsables des espaces verts a permis de constater qu’il y avait toujours place pour la recherche dans ce domaine. Les municipalités veulent connaître, entre autres, quelles espèces d’arbres sont adaptées à l’environnement urbain, quel est l’effet des arbres sur le ruissellement des eaux de pluie et sur la santé humaine. Nous avons aussi constaté qu’il y avait un manque de transfert de connaissances entre les chercheurs et les responsables d’espaces verts ou que les recherches menées ne répondent pas aux besoins exprimés par les répondants. Le présent mémoire a permis de mieux cerner les besoins de recherche des municipalités canadiennes et permettra aux chercheurs de mieux définir les priorités de recherche en foresterie urbaine.
Resumo:
Personal exposure and possible cancer risk to formaldehyde and acetaldehyde were appraised in 8 work places at a university in Brazil. Levels of formaldehyde measured ranged from 22.5 to 161.5 g·m 3 and from 18.3 to 91.2 g·m 3 for acetaldehyde. The personal exposure, expressed as the potential dose in indoor air, was calculated to range from 129.8 to 930.4 g·day 1 (low exposure) and 183.9 to 1318.1 g·day 1 (medium exposure) for formaldehyde and 105.5 to 525.3 g·day 1 (low exposure) and 149.5 to 744.2 g·day 1 (medium exposure) for acetaldehyde. The indoor/outdoor ratio showed the existence of indoor sources of the compounds which were mainly in practical classes and research laboratories. The highest formaldehyde and acetaldehyde levels were found where chemical reagents were manipulated. Relating the levels found to the permissible limit given by the US OSHA showed there was no particular risk although some formaldehyde levels did exceed the lower exposure limit of the US agency NIOSH. Any cancer risk would be highest for female technicians and teaching researchers.
Resumo:
Kandidaatintyön tarkoituksena oli perehtyä Tekesin Terve talo -konseptiin ja tutustua sisäilmaongelmiin. Työn tavoitteina oli kartoittaa sisäilmaongelmien lähteitä ja tutustua Terve talo -rakentamiseen ja tunnistaa ongelmakohtia, jotka johtavat usein kosteus- ja homeongelmiin sekä sisäilmaongelmiin. Näitä haasteita ja ongelmakohtia vertailtiin Terve talo -kriteereihin ja pohdittiin, miten rakentamisen laatua ja ylläpitoa voidaan parantaa, että tulevaisuudessa vältyttäisiin sisäilmaongelmilta. Työ oli kirjallisuustyö, joka perustui kirjallisiin lähteisiin. Työssä käsiteltiin vain uudisrakentamista toimitilarakentamisen Terve talo -kriteereiden avulla. Terve talo -rakentaminen on laadukkaampaa kuin määräykset sanovat. Konseptin mukaan rakennettaessa rakennetaan kosteusteknisesti toimivaa ja terveellistä rakennusta, jossa on hyvä sisäilma. Terve talo -rakennus rakennetaan Terve talo -kriteerien avulla, joita seurataan koko rakennushankkeen ajan. Sisäilmaongelmia aiheuttavat monet eri asiat, kuten hiukkasmaiset ja kaasumaiset epäpuhtaudet. Suuria ongelmia aiheuttavat myös kosteus- ja homeongelmista johtuvat kosteusvauriomikrobit. Epäpuhtaudet aiheuttavat ihmisille terveydellisiä haittoja, kuten silmien ja hengitysteiden ärsyyntymistä. Kosteus- ja homeongelmat voivat johtua monesta syystä. Ongelmia voi aiheuttaa mm. riittämätön suunnittelu, riittämätön kosteudenhallinta työmaalla tai käytön aikaiset virheet. Työn tuloksena voidaan todeta, että kriteereiden avulla voidaan vähentää ja mahdollisesti kokonaan välttyä sisäilmaongelmilta. Rakentaminen vaatii kuitenkin monen asian huomiointia optimointia. Rakennuksen ylläpidon ja huollon tulee myös olla laadukasta ja ennakoivaa.
Resumo:
This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation
Resumo:
Most major cities in the eastern United States have air quality deemed unhealthy by the EPA under a set of regulations known as the National Ambient Air Quality Standards (NAAQS). The worst air quality in Maryland is measured in Edgewood, MD, a small community located along the Chesapeake Bay and generally downwind of Baltimore during hot, summertime days. Direct measurements and numerical simulations were used to investigate how meteorology and chemistry conspire to create adverse levels of photochemical smog especially at this coastal location. Ozone (O3) and oxidized reactive nitrogen (NOy), a family of ozone precursors, were measured over the Chesapeake Bay during a ten day experiment in July 2011 to better understand the formation of ozone over the Bay and its impact on coastal communities such as Edgewood. Ozone over the Bay during the afternoon was 10% to 20% higher than the closest upwind ground sites. A combination of complex boundary layer dynamics, deposition rates, and unaccounted marine emissions play an integral role in the regional maximum of ozone over the Bay. The CAMx regional air quality model was assessed and enhanced through comparison with data from NASA’s 2011 DISCOVER-AQ field campaign. Comparisons show a model overestimate of NOy by +86.2% and a model underestimate of formaldehyde (HCHO) by –28.3%. I present a revised model framework that better captures these observations and the response of ozone to reductions of precursor emissions. Incremental controls on electricity generating stations will produce greater benefits for surface ozone while additional controls on mobile sources may yield less benefit because cars emit less pollution than expected. Model results also indicate that as ozone concentrations improve with decreasing anthropogenic emissions, the photochemical lifetime of tropospheric ozone increases. The lifetime of ozone lengthens because the two primary gas-phase sinks for odd oxygen (Ox ≈ NO2 + O3) – attack by hydroperoxyl radicals (HO2) on ozone and formation of nitrate – weaken with decreasing pollutant emissions. This unintended consequence of air quality regulation causes pollutants to persist longer in the atmosphere, and indicates that pollutant transport between states and countries will likely play a greater role in the future.
Resumo:
Objective: In the setting of the increasing use of closed systems for reconstitution and preparation of these drugs, we intend to analyze the correct use of these systems in the Hospital Pharmacy, with the objective to minimize the risks of exposure not only for those professionals directly involved, but also for all the staff in the unit, taking also into account efficiency criteria. Method: Since some systems protect against aerosol formation but not from vapours, we decided to review which cytostatics should be prepared using an awl with an air inlet valve, in order to implement a new working procedure. We reviewed the formulations available in our hospital, with the following criteria: method of administration, excipients, and potential hazard for the staff handling them. We measured the diameters of the vials. We selected drugs with Level 1 Risk and also those including alcohol-based excipients, which could generate vapours. Outcomes: Out of the 66 reviewed formulations, we concluded that 11 drugs should be reconstituted with this type of awl: busulfan, cabazitaxel, carmustine, cyclophosphamide, eribulin, etoposide, fotemustine, melphalan, paclitaxel, temsirolimus and thiotepa; these represented an 18% of the total volume of formulations. Conclusions: The selection of healthcare products must be done at the Hospital Pharmacy, because the use of a system with an air valve inlet only for those drugs selected led to an outcome of savings and a more efficient use of materials. In our experience, we confirmed that the use of the needle could only be avoided when the awl could adapt to the different formulations of cytostatics, and this is only possible when different types of awls are available. Besides, connections were only really closed when a single awl was used for each vial. The change in working methodology when handling these drugs, as a result of this study, will allow us to start different studies about environmental contamination as a future line of work.
Resumo:
A crescente urbanização global tem como consequência o aumento dos níveis de poluentes na atmosfera e a respetiva deterioração da qualidade do ar. O controlo da poluição atmosférica e monitorização da qualidade do ar são passos fundamentais para implementar estratégias de redução e estimular a consciência ambiental dos cidadãos. Com este intuito, existem várias técnicas e tecnologias que podem ser usadas para monitorizar a qualidade do ar. A utilização de microsensores surge como uma ferramenta inovadora para a monitorização da qualidade do ar. E, apesar dos desempenhos dos microsensores permitirem uma nova estratégia, resultando em respostas rápidas, baixos custos operacionais e eficiências elevadas, que não podem ser alcançados apenas com abordagens convencionais, ainda é necessário aprofundar o conhecimento a fim de integrar estas novas tecnologias, particularmente quanto à verificação do desempenho dos sensores comparativamente aos métodos de referência em campanhas experimentais. Esta dissertação, desenvolvida no Instituto do Ambidente e Desenvolvimento em forma de estágio, teve como objetivo a avaliação do desempenho de sensores de baixo custo comparativamente com os métodos de referência, tendo como base uma campanha de monitorização da qualidade do ar realizada no centro de Aveiro durante 2 semanas de outubro de 2014. De forma mais específica pretende-se perceber até que ponto se podem utilizar sensores de baixo custo que cumpram os requisitos especificados na legislação e as especificidades das normas, estabelecendo assim um protocolo de avaliação de microsensores. O trabalho realizado passou ainda pela caracterização da qualidade do ar no centro de Aveiro para o período da campanha de monitorização. A aplicação de microsensores eletroquímicos, MOS e OPC em paralelo com equipamento de referência neste estudo de campo permitiu avaliar a fiabilidade e a incerteza destas novas tecnologias de monitorização. Com este trabalho verificou-se que os microsensores eletroquímicos são mais precisos comparativamente aos microsensores baseados em óxidos metálicos, apresentando correlações fortes com os métodos de referência para diversos poluentes. Por sua vez, os resultados obtidos pelos contadores óticos de partículas foram satisfatórios, contudo poderiam ser melhorados quer pelo modo de amostragem, quer pelo método de tratamento de dados aplicado. Idealmente, os microsensores deveriam apresentar fortes correlações com o método de referência e elevada eficiência de recolha de dados. No entanto, foram identificados alguns problemas na eficiência de recolha de dados dos sensores que podem estar relacionados com a humidade relativa e temperaturas elevadas durante a campanha, falhas de comunicação intermitentes e, também, a instabilidade e reatividade causada por gases interferentes. Quando as limitações das tecnologias de sensores forem superadas e os procedimentos adequados de garantia e controlo de qualidade possam ser cumpridos, os sensores de baixo custo têm um grande potencial para permitir a monitorização da qualidade do ar com uma elevada cobertura espacial, sendo principalmente benéfico em áreas urbanas.
Resumo:
A crescente urbanização global tem como consequência o aumento dos níveis de poluentes na atmosfera e a respetiva deterioração da qualidade do ar. O controlo da poluição atmosférica e monitorização da qualidade do ar são passos fundamentais para implementar estratégias de redução e estimular a consciência ambiental dos cidadãos. Com este intuito, existem várias técnicas e tecnologias que podem ser usadas para monitorizar a qualidade do ar. A utilização de microsensores surge como uma ferramenta inovadora para a monitorização da qualidade do ar. E, apesar dos desempenhos dos microsensores permitirem uma nova estratégia, resultando em respostas rápidas, baixos custos operacionais e eficiências elevadas, que não podem ser alcançados apenas com abordagens convencionais, ainda é necessário aprofundar o conhecimento a fim de integrar estas novas tecnologias, particularmente quanto à verificação do desempenho dos sensores comparativamente aos métodos de referência em campanhas experimentais. Esta dissertação, desenvolvida no Instituto do Ambidente e Desenvolvimento em forma de estágio, teve como objetivo a avaliação do desempenho de sensores de baixo custo comparativamente com os métodos de referência, tendo como base uma campanha de monitorização da qualidade do ar realizada no centro de Aveiro durante 2 semanas de outubro de 2014. De forma mais específica pretende-se perceber até que ponto se podem utilizar sensores de baixo custo que cumpram os requisitos especificados na legislação e as especificidades das normas, estabelecendo assim um protocolo de avaliação de microsensores. O trabalho realizado passou ainda pela caracterização da qualidade do ar no centro de Aveiro para o período da campanha de monitorização. A aplicação de microsensores eletroquímicos, MOS e OPC em paralelo com equipamento de referência neste estudo de campo permitiu avaliar a fiabilidade e a incerteza destas novas tecnologias de monitorização. Com este trabalho verificou-se que os microsensores eletroquímicos são mais precisos comparativamente aos microsensores baseados em óxidos metálicos, apresentando correlações fortes com os métodos de referência para diversos poluentes. Por sua vez, os resultados obtidos pelos contadores óticos de partículas foram satisfatórios, contudo poderiam ser melhorados quer pelo modo de amostragem, quer pelo método de tratamento de dados aplicado. Idealmente, os microsensores deveriam apresentar fortes correlações com o método de referência e elevada eficiência de recolha de dados. No entanto, foram identificados alguns problemas na eficiência de recolha de dados dos sensores que podem estar relacionados com a humidade relativa e temperaturas elevadas durante a campanha, falhas de comunicação intermitentes e, também, a instabilidade e reatividade causada por gases interferentes. Quando as limitações das tecnologias de sensores forem superadas e os procedimentos adequados de garantia e controlo de qualidade possam ser cumpridos, os sensores de baixo custo têm um grande potencial para permitir a monitorização da qualidade do ar com uma elevada cobertura espacial, sendo principalmente benéfico em áreas urbanas.