994 resultados para Two-Photon absorptions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the effects of temporary tissue expanders (TTEs) on the dose distributions of photon beams in breast cancer radiotherapy treatments. EBT2 radiochromic film and ion chamber measurements were taken to quantify the attenuation and backscatter effects of the inhomogeneity. Results illustrate that the internal magnetic port present in a tissue expander causes a dose reduction of approximately 25% in photon tangent fields immediately downstream of the implant. It was also shown that the silicone elastomer shell of the tissue expander reduced the dose to the target volume by as much as 8%. This work demonstrates the importance for an accurately modelled high-density implant in the treatment planning system for post-mastectomy breast cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we present the challenges associated with the two-way recommendation methods in social networks and the solutions. We discuss them from the perspective of community-type social networks such as online dating networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Pharmacist prescribing has been introduced in several countries and is a possible future role for pharmacy in Australia. Objective To assess whether patient satisfaction with the pharmacist as a prescriber, and patient experiences in two settings of collaborative doctor-pharmacist prescribing may be barriers to implementation of pharmacist prescribing. Design Surveys containing closed questions, and Likert scale responses, were completed in both settings to investigate patient satisfaction after each consultation. A further survey investigating attitudes towards pharmacist prescribing, after multiple consultations, was completed in the sexual health clinic. Setting and Participants A surgical pre-admission clinic (PAC) in a tertiary hospital and an outpatient sexual health clinic at a university hospital. Two hundred patients scheduled for elective surgery, and 17 patients diagnosed with HIV infection, respectively, recruited to the pharmacist prescribing arm of two collaborative doctor-pharmacist prescribing studies. Results Consultation satisfaction response rates in PAC and the sexual health clinic were 182/200 (91%) and 29/34 (85%), respectively. In the sexual health clinic, the attitudes towards pharmacist prescribing survey response rate were 14/17 (82%). Consultation satisfaction was high in both studies, most patients (98% and 97%, respectively) agreed they were satisfied with the consultation. In the sexual health clinic, all patients (14/14) agreed that they trusted the pharmacist’s ability to prescribe, care was as good as usual care, and they would recommend seeing a pharmacist prescriber to friends. Discussion and Conclusion Most of the patients had a high satisfaction with pharmacist prescriber consultations, and a positive outlook on the collaborative model of care in the sexual health clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study investigates the effects of temporary tissue expanders (TTEs) on the dose distributions in breast cancer radiotherapy treatments under a variety of conditions. Methods: Using EBT2 radiochromic film, both electron and photon beam dose distribution measurements were made for different phantoms, and beam geometries. This was done to establish a more comprehensive understanding of the implant’s perturbation effects under a wider variety of conditions. Results: The magnetic disk present in a tissue expander causes a dose reduction of approximately 20% in a photon tangent treatment and 56% in electron boost fields immediately downstream of the implant. The effects of the silicon elastomer are also much more apparent in an electron beam than a photon beam. Conclusions: Evidently, each component of the TTE attenuates the radiation beam to different degrees. This study has demonstrated that the accuracy of photon and electron treatments of post-mastectomy patients is influenced by the presence of a tissue expander for various beam orientations. The impact of TTEs on dose distributions establishes the importance of an accurately modelled high-density implant in the treatment planning system for post-mastectomy patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective fuel injector operation and efficient combustion are two of the most critical aspects when Diesel engine performance, efficiency and reliability are considered. Indeed, it is widely acknowledged that fuel injection equipment faults lead to increased fuel consumption, reduced power, greater levels of exhaust emissions and even unexpected engine failure. Previous investigations have identified fuel injector related acoustic emission activity as being caused by mechanisms such as fuel line pressure build-up; fuel flow through injector nozzles, injector needle opening and closing impacts and premixed combustion related pulses. Few of these investigations however, have attempted to categorise the close association and interrelation that exists between fuel injection equipment function and the acoustic emission generating mechanisms. Consequently, a significant amount of ambiguity remains in the interpretation and categorisation of injector related AE activity with respect to the functional characteristics of specific fuel injection equipment. The investigation presented addresses this ambiguity by detailing a study in which AE signals were recorded and analysed from two different Diesel engines employing the two commonly encountered yet fundamentally different types of fuel injection equipment. Results from tests in which faults were induced into fuel injector nozzles from both indirect-injection and direct-injection engines show that functional differences between the main types of fuel injection equipment results in acoustic emission activity which can be specifically related to the type of fuel injection equipment used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bushfire Responsive Architecture proposals (2) detailed in a 144 page document containing orginal architectural designs and site surveys by Dr Ian Weir. Presented in support of Dr Weir's sucessful planning application for the perminant artwork/land art project "Lightsite Perminant" situated on Point Henry, Western Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the security of two recent RFID mutual authentication protocols are investigated. The first protocol is a scheme proposed by Huang et al. [7] and the second one by Huang, Lin and Li [6]. We show that these two protocols have several weaknesses. In Huang et al.’s scheme, an adversary can determine the 32-bit secret password with a probability of 2−2 , and in Huang-Lin-Li scheme, a passive adversary can recognize a target tag with a success probability of 1−2−4 and an active adversary can determine all 32 bits of Access password with success probability of 2−4 . The computational complexity of these attacks is negligible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present concrete collision and preimage attacks on a large class of compression function constructions making two calls to the underlying ideal primitives. The complexity of the collision attack is above the theoretical lower bound for constructions of this type, but below the birthday complexity; the complexity of the preimage attack, however, is equal to the theoretical lower bound. We also present undesirable properties of some of Stam’s compression functions proposed at CRYPTO ’08. We show that when one of the n-bit to n-bit components of the proposed 2n-bit to n-bit compression function is replaced by a fixed-key cipher in the Davies-Meyer mode, the complexity of finding a preimage would be 2 n/3. We also show that the complexity of finding a collision in a variant of the 3n-bits to 2n-bits scheme with its output truncated to 3n/2 bits is 2 n/2. The complexity of our preimage attack on this hash function is about 2 n . Finally, we present a collision attack on a variant of the proposed m + s-bit to s-bit scheme, truncated to s − 1 bits, with a complexity of O(1). However, none of our results compromise Stam’s security claims.