990 resultados para Two Vertical Cylinders


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze generalized CP symmetries of two-Higgs doublet models, extending them from the scalar to the fermion sector of the theory. We show that, other than the usual CP transformation, there is only one of those symmetries which does not imply massless charged fermions. That single model which accommodates a fermionic mass spectrum compatible with experimental data possesses a remarkable feature. Through a soft breaking of the symmetry it displays a new type of spontaneous CP violation, which does not occur in the scalar sector responsible for the symmetry breaking mechanism but, rather, in the fermion sector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two-Higgs-doublet model can be constrained by imposing Higgs-family symmetries and/or generalized CP symmetries. It is known that there are only six independent classes of such symmetry-constrained models. We study the CP properties of all cases in the bilinear formalism. An exact symmetry implies CP conservation. We show that soft breaking of the symmetry can lead to spontaneous CP violation (CPV) in three of the classes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The minimal supersymmetric standard model involves a rather restrictive Higgs potential with two Higgs fields. Recently, the full set of classes of symmetries allowed in the most general two-Higgs-doublet model was identified; these classes do not include the supersymmetric limit as a particular class. Thus, a physically meaningful definition of the supersymmetric limit must involve the interaction of the Higgs sector with other sectors of the theory. Here we show how one can construct basis invariant probes of supersymmetry involving both the Higgs sector and the gaugino-Higgsino-Higgs interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho incide sobre a análise da eficiência energética dos elevadores. Para se poder entender esta questão, são apresentadas diversas informações que permitem conhecer os factores associados aos consumos de energia activa, procurando-se perceber qual o rendimento destes equipamentos. Inicialmente são analisados os diversos componentes, que fazem parte de um elevador e os locais em que esses componentes são instalados. Abordam-se as diferentes soluções de accionamento, os diversos tipos de utilização e as diferentes tecnologias que podem ser aplicadas. O estudo dos consumos de energia eléctrica dos elevadores, foi efectuado com base na metodologia desenvolvida pelo grupo E4, do programa Utilização Eficiente da Energia, da Comunidade Europeia, cujo suporte foi o DRAFT ISSO/DIS 25745 - 1 Energy Performance of Lifts and Escalators - Part 1: Energy Measurement and Conformance. Os consumos de energia eléctrica serão caracterizados com os elevadores a serem monitorizados individualmente e sem carga na cabina. A apresentação de resultados obtidos terá em linha de conta: a energia eléctrica consumida com o equipamento em modo de funcionamento, ou seja, com este a realizar ciclos completos, e a potência eléctrica consumida com a instalação em modo de standby, ou seja em não operação. No presente trabalho, são divulgados estudos do grupo E4, em que foram monitorizados elevadores em quatro países da Europa: Portugal, Alemanha, Itália e Polónia. Estes estudos permitem estimar os consumos anuais de energia eléctrica, a nível de funcionamento e a nível de standby e estimar o consumo total, seguindo como base a metodologia anteriormente referida. Para se caracterizar o parque Europeu de elevadores, o grupo E4 recorreu à ELA, Associação Europeia de Elevadores, tendo assim sido possível estimar o consumo anual numa Europa a 27, acrescido do parque da Suíça e da Noruega. Pretende-se com isso poder estimar o potencial de redução no consumo energético no parque analisado, com a aplicação das Melhores Tecnologias Disponíveis (MTD) e com a aplicação de tecnologias que ainda estão em fase de desenvolvimento. (MTND). Paralelamente o autor irá apresentar as monitorizações que efectuou a três elevadores, para os quais procurou validar as leituras efectuadas, comparando os consumos obtidos, com os consumos registados pelas monitorizações do grupo E4 e respectivas estimativas de consumos anuais de energia. As monitorizações do autor, serão utilizadas na catalogação desses três equipamentos a nível de classes de eficiência energética, tendo por base a VDI 4707/Part 1 - Lifts - Energy Efficiency - VDI manual Building Services - Volume 5: Transportation Systems. Procura-se, também, criar um método de apoio na tomada de decisão nas diversas fases de um ciclo do elevador, nomeadamente: desde a especificação, a selecção do sistema de accionamento, a selecção dos sistemas auxiliares, a instalação e a operação do elevador, com vista à melhoria da eficiência energética, e á instalação futura ou à modernização dos equipamentos existentes. Abordam-se as barreiras existentes que inibem a mudança no sector de elevação, para a implementação das MTD no parque de elevadores existente ou no desenvolvimento de novas tecnologias que possibilitem a melhoria da eficiência energética, MTND. Por ultimo, aborda-se de forma simples a temática da supervisão técnica nos elevadores, através da monitorização e supervisão dos diversos componentes, com vista à optimização da gestão da manutenção e procurando interligar esta gestão à melhoria da eficiência energética. Consegue-se concluir que apenas com a aplicação das MTD, podem ser obtidos ganhos de eficiência energética, e também que este tema não tem tido a importância que merece, pois, na análise da eficiência energética de um edifício, a eficiência dos elevadores não é tida em consideração. A ausência de legislação específica, que torne a análise da eficiência energética dos elevadores obrigatória, será um dos problemas referidos. Reforça-se que, a potencialidade de poupança energética na Europa não deve ser desprezada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the Miocene through Present compression in the Tagus Abyssal Plain are mapped using the most up to date available to scientific community multi-channel seismic reflection and refraction data. Correlation of the rift basin fault pattern with the deep crustal structure is presented along seismic line IAM-5. Four structural domains were recognized. In the oceanic realm mild deformation concentrates in Domain I adjacent to the Tore-Madeira Rise. Domain 2 is characterized by the absence of shortening structures, except near the ocean-continent transition (OCT), implying that Miocene deformation did not propagate into the Abyssal Plain, In Domain 3 we distinguish three sub-domains: Sub-domain 3A which coincides with the OCT, Sub-domain 3B which is a highly deformed adjacent continental segment, and Sub-domain 3C. The Miocene tectonic inversion is mainly accommodated in Domain 3 by oceanwards directed thrusting at the ocean-continent transition and continentwards on the continental slope. Domain 4 corresponds to the non-rifted continental margin where only minor extensional and shortening deformation structures are observed. Finite element numerical models address the response of the various domains to the Miocene compression, emphasizing the long-wavelength differential vertical movements and the role of possible rheologic contrasts. The concentration of the Miocene deformation in the transitional zone (TC), which is the addition of Sub-domain 3A and part of 3B, is a result of two main factors: (1) focusing of compression in an already stressed region due to plate curvature and sediment loading; and (2) theological weakening. We estimate that the frictional strength in the TC is reduced in 30% relative to the surrounding regions. A model of compressive deformation propagation by means of horizontal impingement of the middle continental crust rift wedge and horizontal shearing on serpentinized mantle in the oceanic realm is presented. This model is consistent with both the geological interpretation of seismic data and the results of numerical modelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Previous cross-sectional studies have shown a high prevalence of chronic disease and disability among the elderly. Given Brazil’s rapid aging process and the obvious consequences of the growing number of old people with chronic diseases and associated disabilities for the provision of health services, a need was felt for a study that would overcome the limitations of cross-sectional data and shed some light on the main factors determining whether a person will live longer and free of disabling diseases, the so-called successful aging. The methodology of the first follow-up study of elderly residents in Brazil is presented. METHOD: The profile of the initial cohort is compared with previous cross-sectional data and an in-depth analysis of nonresponse is carried out in order to assess the validity of future longitudinal analysis. The EPIDOSO (‘Epidemiologia do Idoso’) Study conducted a two-year follow-up of 1,667 elderly people (65+), living in S. Paulo. The study consisted of two waves, each consisting of household, clinical, and biochemical surveys. RESULTS AND CONCLUSIONS: In general, the initial cohort showed a similar profile to previous cross-sectional samples in S. Paulo. There was a majority of women, mostly widows, living in multigenerational households, and a high prevalence of chronic illnesses, psychiatric disturbances, and physical disabilities. Despite all the difficulties inherent in follow-up studies, there was a fairly low rate of nonresponse to the household survey after two years, which did not actually affect the representation of the cohort at the final household assessment, making unbiased longitudinal analysis possible. Concerning the clinical and blood sampling surveys, the respondents tended to be younger and less disabled than the nonrespondents, limiting the use of the clinical and laboratory data to longitudinal analysis aimed at a healthier cohort. It is worth mentioning that gender, education, family support, and socioeconomic status were not important determinants of nonresponse, as is often the case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The crustal and lithospheric mantle structure at the south segment of the west Iberian margin was investigated along a 370 km long seismic transect. The transect goes from unthinned continental crust onshore to oceanic crust, crossing the ocean-continent transition (OCT) zone. The wide-angle data set includes recordings from 6 OBSs and 2 inland seismic stations. Kinematic and dynamic modeling provided a 2D velocity model that proved to be consistent with the modeled free-air anomaly data. The interpretation of coincident multi-channel near-vertical and wide-angle reflection data sets allowed the identification of four main crustal domains: (i) continental (east of 9.4 degrees W); (ii) continental thinning (9.4 degrees W-9.7 degrees W): (iii) transitional (9.7 degrees W-similar to 10.5 degrees W); and (iv) oceanic (west of similar to 10.5 degrees W). In the continental domain the complete crustal section of slightly thinned continental crust is present. The upper (UCC, 5.1-6.0 km/s) and the lower continental crust (LCC, 6.9-7.2 km/s) are seismically reflective and have intermediate to low P-wave velocity gradients. The middle continental crust (MCC, 6.35-6.45 km/s) is generally unreflective with low velocity gradient. The main thinning of the continental crust occurs in the thinning domain by attenuation of the UCC and the LCC. Major thinning of the MCC starts to the west of the LCC pinchout point, where it rests directly upon the mantle. In the thinning domain the Moho slope is at least 13 degrees and the continental crust thickness decreases seaward from 22 to 11 km over a similar to 35 km distance, stretched by a factor of 1.5 to 3. In the oceanic domain a two-layer high-gradient igneous crust (5.3-6.0 km/s; 6.5-7.4 km/s) was modeled. The intra-crustal interface correlates with prominent mid-basement, 10-15 km long reflections in the multi-channel seismic profile. Strong secondary reflected PmP phases require a first order discontinuity at the Moho. The sedimentary cover can be as thick as 5 km and the igneous crustal thickness varies from 4 to 11 km in the west, where the profile reaches the Madeira-Tore Rise. In the transitional domain the crust has a complex structure that varies both horizontally and vertically. Beneath the continental slope it includes exhumed continental crust (6.15-6.45 km/s). Strong diffractions were modeled to originate at the lower interface of this layer. The western segment of this transitional domain is highly reflective at all levels, probably due to dykes and sills, according to the high apparent susceptibility and density modeled at this location. Sub-Moho mantle velocity is found to be 8.0 km/s, but velocities smaller than 8.0 km/s confined to short segments are not excluded by the data. Strong P-wave wide-angle reflections are modeled to originate at depth of 20 km within the lithospheric mantle, under the eastern segment of the oceanic domain, or even deeper at the transitional domain, suggesting a layered structure for the lithospheric mantle. Both interface depths and velocities of the continental section are in good agreement to the conjugate Newfoundland margin. A similar to 40 km wide OCT having a geophysical signature distinct from the OCT to the north favors a two pulse continental breakup.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microcrystalline silicon is a two-phase material. Its composition can be interpreted as a series of grains of crystalline silicon imbedded in an amorphous silicon tissue, with a high concentration of dangling bonds in the transition regions. In this paper, results for the transport properties of a mu c-Si:H p-i-n junction obtained by means of two-dimensional numerical simulation are reported. The role played by the boundary regions between the crystalline grains and the amorphous matrix is taken into account and these regions are treated similar to a heterojunction interface. The device is analysed under AM1.5 illumination and the paper outlines the influence of the local electric field at the grain boundary transition regions on the internal electric configuration of the device and on the transport mechanism within the mu c-Si:H intrinsic layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existe uma necessidade de reabilitação das linhas mais antigas para que estas possam dar maior conforto, comodidade e segurança aos utentes e para que o caminho - de- ferro possa ser competitivo com outros meios de transporte. A REFER é a empresa que gere a conservação, manutenção, renovação das linhas de caminho-de-ferro existentes e a construção de novas linhas. No caso em estudo, trata-se de uma linha de caminho-de-ferro antiga a necessitar de renovação/manutenção, sendo por isso a REFER a empresa responsável pelo lançamento de novos projetos neste âmbito. Este relatório de estágio foi desenvolvido no âmbito do estudo de soluções para a reabilitação do túnel do Loureiro, com o objetivo da criação de condições para a sua eletrificação. Foram equacionados três cenários possíveis, todos eles com o propósito da futura eletrificação da via. A primeira solução passa pela conversão de via balastrada em via não balastrada dentro do túnel, a segunda solução cinge-se à intervenção nas bocas do túnel e nas zonas de alvenaria, e a terceira hipótese é uma solução de rebaixamento de via. De entre as três hipóteses, optou-se por estudar a terceira solução de rebaixamento da via, em detrimento das outras duas devido à sua complexidade de trabalhos e ao seu elevado custo de construção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde (CH2O), the most simple and reactive aldehyde, is a colorless, reactive and readily polymerizing gas at room temperature (National Toxicology Program [NTP]. It has a pungent suffocating odor that is recognized by most human subjects at concentrations below 1 ppm. Aleksandr Butlerov synthesized the chemical in 1859, but it was August Wilhelm von Hofmann who identified it as the product formed from passing methanol and air over a heated platinum spiral in 1867. This method is still the basis for the industrial production of formaldehyde today, in which methanol is oxidized using a metal catalyst. By the early 20th century, with the explosion of knowledge in chemistry and physics, coupled with demands for more innovative synthetic products, the scene was set for the birth of a new material–plastics. According to the Report on Carcinogens, formaldehyde ranks 25th in the overall U.S. chemical production, with more than 5 million tons produced each year. Formaldehyde annual production rises up to 21 million tons worldwide and it has increased in China with 7.5 million tons produced in 2007. Given its economic importance and widespread use, many people are exposed to formaldehyde environmentally and/or occupationally. Commercially, formaldehyde is manufactured as an aqueous solution called formalin, usually containing 37% by weight of dissolved formaldehyde. This chemical is present in all regions of the atmosphere arising from the oxidation of biogenic and anthropogenic hydrocarbons. Formaldehyde concentration levels range typically from 2 to 45 ppbV (parts per billion in a given volume) in urban settings that are mainly governed by primary emissions and secondary formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Int’l J. of Information and Communication Technology Education, 3(2), 1-14, April-June 2007

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-plane deformation of foams was studied experimentally by subjecting bidisperse foams to cycles of traction and compression at a prescribed rate. Each foam contained bubbles of two sizes with given area ratio and one of three initial arrangements: sorted perpendicular to the axis of deformation (iso-strain), sorted parallel to the axis of deformation (iso-stress), or randomly mixed. Image analysis was used to measure the characteristics of the foams, including the number of edges separating small from large bubbles N-sl, the perimeter (surface energy), the distribution of the number of sides of the bubbles, and the topological disorder mu(2)(N). Foams that were initially mixed were found to remain mixed after the deformation. The response of sorted foams, however, depended on the initial geometry, including the area fraction of small bubbles and the total number of bubbles. For a given experiment we found that (i) the perimeter of a sorted foam varied little; (ii) each foam tended towards a mixed state, measured through the saturation of N-sl; and (iii) the topological disorder mu(2)(N) increased up to an "equilibrium" value. The results of different experiments showed that (i) the change in disorder, Delta mu(2)(N), decreased with the area fraction of small bubbles under iso-strain, but was independent of it under iso-stress; and (ii) Delta mu(2)(N) increased with Delta N-sl under iso-strain, but was again independent of it under iso-stress. We offer explanations for these effects in terms of elementary topological processes induced by the deformations that occur at the bubble scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have performed Surface Evolver simulations of two-dimensional hexagonal bubble clusters consisting of a central bubble of area lambda surrounded by s shells or layers of bubbles of unit area. Clusters of up to twenty layers have been simulated, with lambda varying between 0.01 and 100. In monodisperse clusters (i.e., for lambda = 1) [M.A. Fortes, F Morgan, M. Fatima Vaz, Philos. Mag. Lett. 87 (2007) 561] both the average pressure of the entire Cluster and the pressure in the central bubble are decreasing functions of s and approach 0.9306 for very large s, which is the pressure in a bubble of an infinite monodisperse honeycomb foam. Here we address the effect of changing the central bubble area lambda. For small lambda the pressure in the central bubble and the average pressure were both found to decrease with s, as in monodisperse clusters. However, for large,, the pressure in the central bubble and the average pressure increase with s. The average pressure of large clusters was found to be independent of lambda and to approach 0.9306 asymptotically. We have also determined the cluster surface energies given by the equation of equilibrium for the total energy in terms of the area and the pressure in each bubble. When the pressures in the bubbles are not available, an approximate equation derived by Vaz et al. [M. Fatima Vaz, M.A. Fortes, F. Graner, Philos. Mag. Lett. 82 (2002) 575] was shown to provide good estimations for the cluster energy provided the bubble area distribution is narrow. This approach does not take cluster topology into account. Using this approximate equation, we find a good correlation between Surface Evolver Simulations and the estimated Values of energies and pressures. (C) 2008 Elsevier B.V. All rights reserved.