957 resultados para Solid-phase Synthesis


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As operações de separação por adsorção têm vindo a ganhar importância nos últimos anos, especialmente com o desenvolvimento de técnicas de simulação de leitos móveis em colunas, tal como a cromatografia de Leito Móvel Simulado (Simulated Moving Bed, SMB). Esta tecnologia foi desenvolvida no início dos anos 60 como método alternativo ao processo de Leito Móvel Verdadeiro (True Moving Bed, TMB), de modo a resolver vários dos problemas associados ao movimento da fase sólida, usuais nestes métodos de separação cromatográficos de contracorrente. A tecnologia de SMB tem sido amplamente utilizada em escala industrial principalmente nas indústrias petroquímica e de transformação de açúcares e, mais recentemente, na indústria farmacêutica e de química fina. Nas últimas décadas, o crescente interesse na tecnologia de SMB, fruto do alto rendimento e eficiente consumo de solvente, levou à formulação de diferentes modos de operação, ditos não convencionais, que conseguem unidades mais flexíveis, capazes de aumentar o desempenho de separação e alargar ainda mais a gama de aplicação da tecnologia. Um dos exemplos mais estudados e implementados é o caso do processo Varicol, no qual se procede a um movimento assíncrono de portas. Neste âmbito, o presente trabalho foca-se na simulação, análise e avaliação da tecnologia de SMB para dois casos de separação distintos: a separação de uma mistura de frutose-glucose e a separação de uma mistura racémica de pindolol. Para ambos os casos foram considerados e comparados dois modos de operação da unidade de SMB: o modo convencional e o modo Varicol. Desta forma, foi realizada a implementação e simulação de ambos os casos de separação no simulador de processos Aspen Chromatography, mediante a utilização de duas unidades de SMB distintas (SMB convencional e SMB Varicol). Para a separação da mistura frutose-glucose, no quediz respeito à modelização da unidade de SMB convencional, foram utilizadas duas abordagens: a de um leito móvel verdadeiro (modelo TMB) e a de um leito móvel simulado real (modelo SMB). Para a separação da mistura racémica de pindolol foi considerada apenas a modelização pelo modelo SMB. No caso da separação da mistura frutose-glucose, procedeu-se ainda à otimização de ambas as unidades de SMB convencional e Varicol, com o intuito do aumento das suas produtividades. A otimização foi realizada mediante a aplicação de um procedimento de planeamento experimental, onde as experiências foram planeadas, conduzidas e posteriormente analisadas através da análise de variância (ANOVA). A análise estatística permitiu selecionar os níveis dos fatores de controlo de modo a obter melhores resultados para ambas as unidades de SMB.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The interest for environmental fate assessment of chiral pharmaceuticals is increasing and enantioselective analytical methods are mandatory. This study presents an enantioselective analytical method for the quantification of seven pairs of enantiomers of pharmaceuticals and a pair of a metabolite. The selected chiral pharmaceuticals belong to three different therapeutic classes, namely selective serotonin reuptake inhibitors (venlafaxine, fluoxetine and its metabolite norfluoxetine), beta-blockers (alprenolol, bisoprolol, metoprolol, propranolol) and a beta2-adrenergic agonist (salbutamol). The analytical method was based on solid phase extraction followed by liquid chromatography tandem mass spectrometry with a triple quadrupole analyser. Briefly, Oasis® MCX cartridges were used to preconcentrate 250 mL of water samples and the reconstituted extracts were analysed with a Chirobiotic™ V under reversed mode. The effluent of a laboratory-scale aerobic granular sludge sequencing batch reactor (AGS-SBR) was used to validate the method. Linearity (r2 > 0.99), selectivity and sensitivity were achieved in the range of 20–400 ng L−1 for all enantiomers, except for norfluoxetine enantiomers which range covered 30–400 ng L−1. The method detection limits were between 0.65 and 11.5 ng L−1 and the method quantification limits were between 1.98 and 19.7 ng L−1. The identity of all enantiomers was confirmed using two MS/MS transitions and its ion ratios, according to European Commission Decision 2002/657/EC. This method was successfully applied to evaluate effluents of wastewater treatment plants (WWTP) in Portugal. Venlafaxine and fluoxetine were quantified as non-racemic mixtures (enantiomeric fraction ≠ 0.5). The enantioselective validated method was able to monitor chiral pharmaceuticals in WWTP effluents and has potential to assess the enantioselective biodegradation in bioreactors. Further application in environmental matrices as surface and estuarine waters can be exploited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O leite é um alimento complexo, pela sua composição rico em água, proteínas, lípidos, vitaminas e minerais. Devido ao seu alto valor nutricional é fundamental para a amamentação de crianças e animais em crescimento, pois fornece componentes fundamentais para o desenvolvimento e manutenção da saúde. Os antimicrobianos são amplamente utilizados como uma medida terapêutica no tratamento de infeções bacterianas, profilaxia e como promotores de crescimento (aditivos). A presença de resíduos de antimicrobianos no leite pode representar riscos para a saúde humana, como reações alérgicas em indivíduos hipersensíveis e resistências. Os objetivos deste estudo são o desenvolvimento de novos métodos de limpeza e de pré-concentração para amostras de leite, por meio de extração em fase sólida (SPE), com a finalidade de realizar uma melhor identificação e quantificação de antimicrobiana por Cromatografia Líquida de Alta Performance (HPLC). Todos os métodos desenvolvidos são de fácil execução, com taxas de recuperação dos agentes antimicrobianos viáveis, com uma percentagem de recuperação a partir de 85%. O método cromatográfico utilizado para a deteção e quantificação (HPLC-DAD) têm os limites de deteção (LD) entre 2.43ng / mL e 1.62ng / mL e os limites de quantificação (LQ) entre 7,36 ng / mL e 4.92 ng / mL, o que significa este método vai de encontro às diretrizes estipuladas pela União Europeia para os agentes antimicrobianos estudados. A combinação dos métodos propostos de limpeza e pré-concentração por SPE e multirresíduo por HPLC-DAD permite, por conseguinte, a deteção e quantificação de resíduos de antibióticos no leite, tornando esta uma alternativa importante e útil no processo de controlo de qualidade para a indústria de alimentos e outras área.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An analytical methodology for the simultaneous determination of seven pharmaceuticals and two metabolites belonging to the non-steroidal anti-inflammatory drugs (NSAIDs) and analgesics therapeutic groups was developed based on off-line solid-phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry (SPE–UHPLC–MS/MS). Extraction conditions were optimized taking into account parameters like sorbent material, sample volume and sample pH. Method detection limits (MDLs) ranging from 0.02 to 8.18 ng/L were obtained. This methodology was successfully applied to the determination of the selected pharmaceuticals in seawater samples of Atlantic Ocean in the Northern Portuguese coast. All the pharmaceuticals have been detected in the seawater samples, with pharmaceuticals like ibuprofen, acetaminophen, ketoprofen and the metabolite hydroxyibuprofen being the most frequently detected at concentrations that can reach some hundreds of ng/L.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Gestão de Sistemas Ambientais

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Staphylococcus aureus harbors redundant adhesins mediating tissue colonization and infection. To evaluate their intrinsic role outside of the staphylococcal background, a system was designed to express them in Lactococcus lactis subsp. cremoris 1363. This bacterium is devoid of virulence factors and has a known genetic background. A new Escherichia coli-L. lactis shuttle and expression vector was constructed for this purpose. First, the high-copy-number lactococcal plasmid pIL253 was equipped with the oriColE1 origin, generating pOri253 that could replicate in E. coli. Second, the lactococcal promoters P23 or P59 were inserted at one end of the pOri253 multicloning site. Gene expression was assessed by a luciferase reporter system. The plasmid carrying P23 (named pOri23) expressed luciferase constitutively at a level 10,000 times greater than did the P59-containing plasmid. Transcription was absent in E. coli. The staphylococcal clumping factor A (clfA) gene was cloned into pOri23 and used as a model system. Lactococci carrying pOri23-clfA produced an unaltered and functional 130-kDa ClfA protein attached to their cell walls. This was indicated both by the presence of the protein in Western blots of solubilized cell walls and by the ability of ClfA-positive lactococci to clump in the presence of plasma. ClfA-positive lactococci had clumping titers (titer of 4,112) similar to those of S. aureus Newman in soluble fibrinogen and bound equally well to solid-phase fibrinogen. These experiments provide a new way to study individual staphylococcal pathogenic factors and might complement both classical knockout mutagenesis and modern in vivo expression technology and signature tag mutagenesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The goal of this thesis was to study factors related to the development of Brassica juncea as a sustainable nematicide. Brassica juncea is characterized by the glycoside (glucosinolate) sinigrin. Various methods were developed for the determination of sinigrin in Brassica juncea tissue extracts. Sinigrin concentrations in plant tissues at various stages of growth were monitored. Sinigrin enzymatically breaks down into allylisothiocyanate (AITC). AITC is unstable in aqueous solution and degradation was studied in water and in soil. Finally, the toxicity of AITC against the root-lesion nematode (Pratylenchus penetrans) was determined. A method was developed to extract sinigrin from whole Brassica j uncea tissues. The optimal time of extraction wi th boiling phosphate buffer (0.7mM, pH=6.38) and methanol/water (70:30 v/v) solutions were both 25 minutes. Methanol/water extracted 13% greater amount of sinigrin than phosphate buffer solution. Degradation of sinigrin in boiling phosphate buffer solution (0.13%/minute) was similar to the loss of sinigrin during the extraction procedure. The loss of sinigrin from boiling methanol/water was estimated to be O.Ol%/minute. Brassica juncea extract clean up was accomplished by an ion-pair solid phase extraction (SPE) method. The recovery of sinigrin was 92.6% and coextractive impurities were not detected in the cleaned up extract. Several high performance liquid chromatography (HPLC) methods were developed for the determination of sinigrin. All the developed methods employed an isocratic mobile phase system wi th a low concentration of phosphate buffer solution, ammonium acetate solution or an ion-pair reagent solution. A step gradient system was also developed. The method involved preconditioning the analytical column with phosphate buffer solution and then switching the mobile phase to 100% water after sample injection.Sinigrin and benzyl-glucosinolate were both studied by HPLC particle beam negative chemical ionization mass spectrometry (HPLCPB- NCI-MS). Comparison of the mass spectra revealed the presence of fragments arising from the ~hioglucose moiety and glucosinolate side-chain. Variation in the slnlgrin concentration within Brassica juncea plants was studied (Domo and Cutlass cuItivars). The sinigrin concentration in the top three leaves was studied during growth of each cultivar. For Cutlass, the minimum (200~100~g/g) and maximum (1300~200~g/g) concentrations were observed at the third and seventh week after planting, respectively. For Domo, the minimum (190~70~g/g) and maximum (1100~400~g/g) concentrations were observed at the fourth and eighth week after planting, respectively. The highest sinigrin concentration was observed in flower tissues 2050±90~g/g and 2300±100~g/g for Cutlass and Domo cultivars, respectively. Physical properties of AITC were studied. The solubility of AITC in water was determined to be approximately 1290~g/ml at 24°C. An HPLC method was developed for the separation of degradation compounds from aqueous AITC sample solutions. Some of the degradation compounds identified have not been reported in the literature: allyl-thiourea, allyl-thiocyanate and diallyl-sulfide. In water, AITC degradation to' diallyl-thiourea was favored at basic pH (9.07) and degradation to diallyl-sulfide was favored at acidic pH (4 . 97). It wap necessary to amend the aqueous AITC sample solution with acetonitrile ?efore injection into the HPLC system. The acetonitrile amendment considerably improved AITC recovery and the reproducibility of the results. The half-life of aqueous AITC degradation at room temperature did not follow first-order kinetics. Beginning with a 1084~g/ml solution, the half-life was 633 hours. Wi th an ini tial AITC concentration of 335~g/ml the half-life was 865 hours. At 35°C the half-life AITC was 76+4 hours essentially independent of the iiisolution pH over the range of pH=4.97 to 9.07 (1000~g/ml). AITC degradation was also studied in soil at 35°C; after 24 hours approximately 75% of the initial AITC addition was unrecoverable by water extraction. The ECso of aqueous AITC against the root-lesion nematode (Pratylenchus penetrans) was determined to be approximately 20~g/ml at one hour exposure of the nematode to the test solution. The toxicological study was also performed with a myrosinase treated Brassica juncea extract. Myrosinase treatment of the Brassica juncea extract gave nearly quantitative conversion of sinigrin into AITC. The myrosinase treated extract was of the same efficacy as an aqueous AITC solution of equivalent concentration. The work of this thesis was focused upon understanding parameters relevant to the development of Brassica juncea as a sustainable nematicide. The broad range of experiments were undertaken in support of a research priority at Agriculture and Agri-Food Canada.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’électrofilage est une technique permettant de fabriquer des fibres polymériques dont le diamètre varie entre quelques nanomètres et quelques microns. Ces fibres ont donc un rapport surface/volume très élevé. Les fibres électrofilées pourraient trouver des applications dans le relargage de médicaments et le génie tissulaire, comme membranes et capteurs chimiques, ou dans les nanocomposites et dispositifs électroniques. L’électrofilage était initialement utilisé pour préparer des toiles de fibres désordonnées, mais il est maintenant possible d’aligner les fibres par l’usage de collecteurs spéciaux. Cependant, il est important de contrôler non seulement l’alignement macroscopique des fibres mais aussi leur orientation au niveau moléculaire puisque l’orientation influence les propriétés mécaniques, optiques et électriques des polymères. Les complexes moléculaires apparaissent comme une cible de choix pour produire des nanofibres fortement orientées. Dans les complexes d’inclusion d’urée, les chaînes polymères sont empilées dans des canaux unidimensionnels construits à partir d’un réseau tridimensionnel de molécules d’urée liées par des ponts hydrogène. Ainsi, les chaînes polymère sonts très allongées à l’échelle moléculaire. Des nanofibres du complexe PEO-urée ont été préparées pour la première fois par électrofilage de suspensions et de solutions. Tel qu’attendu, une orientation moléculaire inhabituellement élevée a été observée dans ces fibres. De tels complexes orientés pourraient être utilisés à la fois dans des études fondamentales et dans la préparation de matériaux hiérarchiquement structurés. La méthode d’électrofilage peut parfois aussi être utilisée pour préparer des matériaux polymériques métastables qui ne peuvent pas être préparés par des méthodes conventionnelles. Ici, l’électrofilage a été utilisé pour préparer des fibres des complexes stables (α) et "métastables" (β) entre le PEO et l’urée. La caractérisation du complexe β, qui était mal connu, révèle un rapport PEO:urée de 12:8 appartenant au système orthorhombique avec a = 1.907 nm, b = 0.862 nm et c = 0.773 nm. Les chaînes de PEO sont orientées selon l’axe de la fibre. Leur conformation est significativement affectée par les ponts hydrogène. Une structure en couches a été suggérée pour la forme β, plutôt que la structure conventionnelle en canaux adoptée par la forme α. Nos résultats indiquent que le complexe β est thermodynamiquement stable avant sa fonte et peut se transformer en forme α et en PEO liquide par un processus de fonte et recristallisation à 89 ºC. Ceci va dans le sens contraire aux observations faites avec le complexe β obtenu par trempe du complexe α fondu. En effet, le complexe β ainsi obtenu est métastable et contient des cristaux d’urée. Il peut subir une transition de phases cinétique solide-solide pour produire du complexe α dans une vaste gamme de températures. Cette transition est induite par un changement de conformation du PEO et par la formation de ponts hydrogène intermoléculaires entre l’urée et le PEO. Le diagramme de phases du système PEO-urée a été tracé sur toute la gamme de compositions, ce qui a permis d’interpréter la formation de plusieurs mélanges qui ne sont pas à l’équilibre mais qui sont été observés expérimentalement. La structure et le diagramme de phases du complexe PEO-thiourée, qui est aussi un complexe très mal connu, ont été étudiés en détail. Un rapport molaire PEO :thiourée de 3:2 a été déduit pour le complexe, et une cellule monoclinique avec a = 0.915 nm, b = 1.888 nm, c = 0.825 nm et β = 92.35º a été déterminée. Comme pour le complexe PEO-urée de forme β, une structure en couches a été suggérée pour le complexe PEO-thiourée, dans laquelle les molécules de thiourée seraient disposées en rubans intercalés entre deux couches de PEO. Cette structure en couches pourrait expliquer la température de fusion beaucoup plus faible des complexes PEO-thiourée (110 ºC) et PEO-urée de forme β (89 ºC) en comparaison aux structures en canaux du complexe PEO-urée de forme α (143 ºC).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le présent projet vise à documenter la nécessité d’augmenter notre connaissance de la présence des contaminants organiques tels que les médicaments dans l’environnement et d’évaluer leur devenir environnemental. On a étudié la présence de composés pharmaceutiques dans différents échantillons d'eau. On a focalisé nos efforts spécialement sur les échantillons d'eau de l'usine d'épuration de la Ville de Montréal et ses effluents, les eaux de surface avoisinantes et l’eau du robinet dans la région de Montréal. Pour ce faire, on a tout d’abord développé deux méthodes analytiques automatisées basées sur la chromatographie liquide avec extraction en phase solide (SPE) couplée à la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). On a également étudié les performances des trois techniques d'ionisation à pression atmosphérique (API), pour ensuite les utiliser dans la méthode analytique développée. On a démontré que l'ionisation par électronébulisation (ESI) est une méthode d'ionisation plus efficace pour l'analyse des contaminants pharmaceutiques dans des échantillons de matrices très complexes comme les eaux usées. Une première méthode analytique SPE couplée à la LC-MS/MS a été développée et validée pour l'étude des échantillons complexes provenant de l'usine d'épuration de la Ville de Montréal et des eaux de surface près de l'usine. Cinq médicaments de prescription ont été étudiés: le bézafibrate (un régulateur de lipides), le cyclophosphamide et le méthotrexate (deux agents anticancéreux), l'orlistat (un agent anti-obésité) et l’énalapril (utilisé dans le traitement de l'hypertension). La plupart de ces drogues sont excrétées par le corps humain et rejetées dans les eaux usées domestiques en faisant par la suite leur chemin vers les usines municipales de traitement des eaux usées. On a pu démontrer qu'il y a un faible taux d’élimination à l'usine d'épuration pour le bézafibrate et l'énalapril. Ces deux composés ont aussi été détectés dans les eaux de surface sur un site à proximité immédiate de la décharge de l’effluent de la station d'épuration. i En observant la nécessité de l'amélioration des limites de détection de la première méthode analytique, une deuxième méthode a été développée. Pour la deuxième méthode, un total de 14 contaminants organiques, incluant trois agents anti-infectieux (clarithromycin, sulfaméthoxazole et triméthoprime), un anticonvulsant (carbamazépine) et son produit de dégradation (10,11-dihydrocarbamazépine), l'agent antihypertensif (enalapril), deux antinéoplastiques utilisés en chimiothérapie (cyclophosphamide et méthotrexate), des herbicides (atrazine, cyanazine, et simazine) et deux produits de transformation de l’atrazine (deséthylatrazine et déisopropylatrazine) ainsi qu’un agent antiseptique (triclocarban). Ces produits ont été quantifiés dans les eaux de surface ainsi que dans l’eau du robinet. L'amélioration des limites de détection pour cette méthode a été possible grâce à la charge d'un volume d'échantillon supérieur à celui utilisé dans la première méthode (10 mL vs 1 mL). D'autres techniques de confirmation, telles que les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle et la mesure des masses exactes par spectrométrie de masse à temps d’envol, ont été explorées. L'utilisation d'un analyseur de masse à temps d’envol a permis la confirmation de 6 des 14 analytes. Finalement, étant donné leur haute toxicité et pour évaluer leur persistance et leur transformation au niveau du traitement des eaux potables, la cinétique d'oxydation du cyclophosphamide et de méthotrexate avec l'ozone moléculaire et des radicaux OH a été étudiée. Les constantes de dégradation avec l'ozone moléculaire ont été calculées et la qualité de l'eau après traitement a pu être évaluée. Le rendement du processus d'ozonation a été amélioré pour la cyclophosphamide dans les eaux naturelles, en raison de la combinaison de réactions directes et indirectes. Cette étude a montré que l'ozone est très efficace pour oxyder le méthotrexate mais que le cyclophosphamide serait trop lent à s’oxyder pour un traitement efficace aux conditions usuelles de traitement de l’eau potable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les sols forestiers constituent un réservoir considérable d’éléments nutritifs disponibles pour soutenir la productivité forestière. Ces sols contiennent aussi une quantité, encore inconnue à ce jour, d’éléments traces biodisponibles provenant de sources anthropiques ou naturelles. Or, plusieurs de ces éléments recèlent un potentiel toxique pour les organismes vivants. Ainsi, la quantification de la concentration et du contenu total en éléments traces des sols forestiers s’avère nécessaire afin d’évaluer les impacts des perturbations sur la qualité des sols. Les objectifs de ce projet de recherche sont: 1) de mesurer le contenu total en éléments traces en phase solide (Ag, As, Ba, Cd, Ce, Co, Cr, Cu, Mn, Ni, Pb, Rb, Se, Sr, Tl, V, Y, Zn) des divers horizons de sols d’écosystèmes forestiers du Québec méridional; 2) d’établir des liens significatifs entre la fraction soluble dans l’eau des éléments traces et les propriétés des horizons de sols et; 3) d’évaluer le rôle de la proximité d’un centre urbain sur les contenus en éléments traces. Pour répondre à ces objectifs, quatre profils de sols situés dans la région de St-Hippolyte et deux situés dans la région de Montréal furent échantillonnés jusqu'à l'atteinte du matériel parental. Les résultats de ce projet de recherche ont révélé que le contenu total en éléments traces présents dans les profils de sols se retrouve en grande partie dans les fragments grossiers du sol. Il a été démontré que la teneur en carbone organique, les complexes organométalliques et les oxydes de fer et d’aluminium dictent la distribution en profil de la majorité des éléments traces étudiés. Finalement, il fut prouvé que la région de Montréal présente des niveaux de contamination en éléments traces (Ag, As, Ba, Cu, Mn, Pb, Rb, Se, Sr, Tl et Zn) supérieurs à ceux rencontrés dans les Laurentides.