910 resultados para Serologic tests
Resumo:
This study describes the development and establishment of a proposed Simple Performance Test (SPT) specification in order to contribute to the asphalt materials technology in the state of Michigan. The properties and characteristic of materials, performance testing of specimens, and field analyses are used in developing draft SPT specifications. These advanced and more effective specifications should significantly improve the qualities of designed and constructed hot mix asphalt (HMA) leading to improvement in pavement life in Michigan. The objectives of this study include the following: 1) using the SPT, conduct a laboratory study to measure the parameters including the dynamic modulus terms (E*/sinϕ and E*) and the flow number (Fn) for typical Michigan HMA mixtures, 2) correlate the results of the laboratory study to field performance as they relate to flexible pavement performance (rutting, fatigue, and low temperature cracking), and 3) make recommendations for the SPT criteria at specific traffic levels (e.g. E3, E10, E30), including recommendations for a draft test specification for use in Michigan. The specification criteria of dynamic modulus were developed based upon field rutting performance and contractor warranty criteria.
Resumo:
Coal is an aggregation of vegetal matter with varying small amounts of mineral and animal matter which have been so changed by the processes of sedimentation, decay and metamorphism that it has become a dense, dark, combustible substance. It occurs in beds varying in thickness from one foot or less to over 300 feet. The horizontal extent of a bed is sometimes continuous over an area as large as the State of Montana.
Resumo:
Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.
Resumo:
The James Lind Library (www.jameslindlibrary.org) has been established to improve public and professional general knowledge about fair tests of treatments in healthcare and their history. Its foundation was laid ten years ago at the Royal College of Physicians of Edinburgh, and its administrative centre is in the College's Sibbald Library, one of the most important collections of historic medical manuscripts, papers and books in the world. The James Lind Library is a website that introduces visitors to the principles of fair tests of treatments, with a series of short, illustrated essays, which are currently available in English, Arabic, Chinese, French, Portuguese, Russian and Spanish. A 100-page book-- Testing Treatments--is now available free through the website, both in English and in Arabic and Spanish translations. To illustrate the evolution of ideas related to fair tests of treatments from 2000 BC to the present, the James Lind Library contains key passages and images from manuscripts, books and journal articles, many of them accompanied by commentaries, biographies, portraits and other relevant documents and images, including audio and video files. New material is being added to the website continuously, as relevant new records are identified and as methods for testing treatments evolve. A multinational, multilingual editorial team oversees the development of the website, which currently receives tens of thousands of visitors every month.
Resumo:
The diagnosis of a drug hypersensitivity reaction (DHR) is a challenging task because multiple and complex mechanisms are involved. Better understanding of immunologic pathomechanisms in DHRs and rapid progress in cellular-based in-vitro tests can help to adjust the correct diagnostic strategy to individual patients with different clinical manifestations of drug allergy. Thus, drug hypersensitivity diagnosis needs to rely on a combination of medical history and different in vivo and in vitro tests. In this article, the authors discuss current in vitro techniques, most recent findings, and new promising tools in the diagnosis of T-cell-mediated drug hypersensitivity.
Resumo:
Objective assessments of subjective complaints such as sleepiness, tiredness or fatigue using sleepiness and vigilance tests aim to identify its causes and to judge the fitness to drive or to work of the affected person. "Vigilance" comprises wakefulness, alertness and attention and is therefore not merely reciprocal to sleepiness. Since it is a complex phenomenon with several dimensions it is unlikely to be appropriately assessed by one single "vigilance test". One important dimension of vigilance discussed here is wakefulness with its counterpart of overt sleep and the whole spectrum of various levels in between. The transit zone between full wakefulness and overt sleep is mainly characterised by the subjective complaint of sleepiness, which cannot be measured directly. Only the consequences of reduced wakefulness such as a shortened sleep latency, slowed cognitive function and prolonged reaction time can be measured objectively. It is, therefore, more promising to combine a battery of subjective and objective tests to answer a specific question in order to achieve the most appropriate description for a given clinical or medicolegal situation. However even then we must keep in mind that many other important aspects of fitness to drive / fitness to work such as neurological, psychiatric and neuropsychological functions including risk taking behaviour are not covered by vigilance tests. A comprehensive, multidisciplinary approach is essential in such situations.
Resumo:
Writing unit tests for legacy systems is a key maintenance task. When writing tests for object-oriented programs, objects need to be set up and the expected effects of executing the unit under test need to be verified. If developers lack internal knowledge of a system, the task of writing tests is non-trivial. To address this problem, we propose an approach that exposes side effects detected in example runs of the system and uses these side effects to guide the developer when writing tests. We introduce a visualization called Test Blueprint, through which we identify what the required fixture is and what assertions are needed to verify the correct behavior of a unit under test. The dynamic analysis technique that underlies our approach is based on both tracing method executions and on tracking the flow of objects at runtime. To demonstrate the usefulness of our approach we present results from two case studies.
Resumo:
To quickly localize defects, we want our attention to be focussed on relevant failing tests. We propose to improve defect localization by exploiting dependencies between tests, using a JUnit extension called JExample. In a case study, a monolithic white-box test suite for a complex algorithm is refactored into two traditional JUnit style tests and to JExample. Of the three refactorings, JExample reports five times fewer defect locations and slightly better performance (-8-12\%), while having similar maintenance characteristics. Compared to the original implementation, JExample greatly improves maintainability due the improved factorization following the accepted test quality guidelines. As such, JExample combines the benefits of test chains with test quality aspects of JUnit style testing.
Resumo:
Recurrent airway obstruction (RAO) is a common condition in stabled horses characterised by small airway inflammation, airway neutrophilia and obstruction following exposure of susceptible horses to mouldy hay and straw and is thus regarded as a hypersensitivity reaction to mould spores. However, the role of IgE-mediated reactions in RAO remains unclear. The aim of the study was to investigate with a serological IgE ELISA test (Allercept), an in vitro sulfidoleukotriene (sLT) release assay (CAST) and with intradermal testing (IDT) whether serum IgE and IgE-mediated reactions against various mould, mite and pollen extracts are associated with RAO. IDT reactions were evaluated at different times in order to detect IgE-mediated immediate type reactions (type I hypersensitivity reactions, 0.5-1 h), immune complex-mediated late type reactions (type III reactions, 4-10 h) and cell-mediated delayed type reactions (type IV hypersensitivity reactions 24-48 h). In the serological test, overall the control horses displayed more positive reactions than the RAO-affected horses but the difference was not significant. Comparison of the measured IgE levels showed that the RAO-affected horses had slightly higher IgE levels against Aspergillus fumigatus than controls (35 and 16 AU, respectively, p<0.05), but all values were below the cut off (150 AU) of the test. In the sLT release assay, seven positive reactions were observed in the RAO-affected horses and four in the controls but this difference was not significant. A significantly higher proportion of late type IDT reactions was observed in RAO-affected horses compared to controls (25 of 238 possible reactions versus 12 of 238 possible reactions, respectively, p<0.05). Interestingly, four RAO-affected but none of the control horses reacted with the recombinant mould allergen A. fumigatus 8 (rAsp f 8, p<0.05), but only late phase and delayed type reactions were observed. In all three tests the majority of the positive reactions was observed with the mite extracts (64%, 74% and 88% of all positive reactions, respectively) but none of the tests showed a significant difference between RAO-affected and control animals. Our findings do not support that IgE-mediated reactions are important in the pathogenesis of RAO. Further studies are needed to investigate whether sensitisation to mite allergens is of clinical relevance in the horse and to understand the role of immune reactions against rAsp f 8.
Resumo:
Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.