901 resultados para Repetitive transcranial magnetic stimulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Repetition of environmental sounds, like their visual counterparts, can facilitate behavior and modulate neural responses, exemplifying plasticity in how auditory objects are represented or accessed. It remains controversial whether such repetition priming/suppression involves solely plasticity based on acoustic features and/or also access to semantic features. To evaluate contributions of physical and semantic features in eliciting repetition-induced plasticity, the present functional magnetic resonance imaging (fMRI) study repeated either identical or different exemplars of the initially presented object; reasoning that identical exemplars share both physical and semantic features, whereas different exemplars share only semantic features. Participants performed a living/man-made categorization task while being scanned at 3T. Repeated stimuli of both types significantly facilitated reaction times versus initial presentations, demonstrating perceptual and semantic repetition priming. There was also repetition suppression of fMRI activity within overlapping temporal, premotor, and prefrontal regions of the auditory "what" pathway. Importantly, the magnitude of suppression effects was equivalent for both physically identical and semantically related exemplars. That the degree of repetition suppression was irrespective of whether or not both perceptual and semantic information was repeated is suggestive of a degree of acoustically independent semantic analysis in how object representations are maintained and retrieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le répertoire cellulaire Τ a pour but d'être tolérant aux antigènes du soi afin d'éviter l'induction de maladies autoimmunes. C'est pourquoi les lymphocytes Τ autoréactifs sont éliminés dans le thymus lors de leur développement par le processus de sélection négative. La plupart des recherches étudient les lymphocytes Τ de haute avidité. Ces lymphocytes Τ de haute avidité sont très sensibles et réagissent fortement à un antigène du soi. En conséquence, ces cellules induisent le développement de maladies autoimmunes lorsqu'elles ciblent des organes exprimant l'antigène du soi. Plusieurs études ont montré que les lymphocytes Τ qui réagissent faiblement aux antigènes spécifiques à un tissu, nommé lymphocytes Τ de faible avidité, peuvent contourner les mécanismes de tolérance centrale et périphérique. J'ai utilisé des souris Rip-mOva qui expriment l'Ovalbumine comme antigène du soi spécifique à un tissu. Dans ces souris transgéniques Rip-mOva, les lymphocytes Τ de faible avidité survivent à la sélection négative. Une fois stimulés à la périphérie, ces lymphocytes Τ CD8+ de faible avidité ont la capacité d'infiltrer les organes qui expriment l'antigène du soi chez les souris Rip-mOva et peuvent induire une destruction tissulaire. L'objectif principal de mon projet de thèse était de comprendre les caractéristiques phénotypiques et fonctionnelles de ces lymphocytes Τ dans un état d'équilibre et dans un contexte infectieux. Pour étudier ces cellules dans un modèle murin bien défini, nous avons généré des souris exprimant un récepteur de cellule Τ transgénique appelé OT-3. Ces souris transgéniques OT-3 ont des lymphocytes Τ CD8+ de faible avidité spécifiques à l'épitope SIINFEKL de l'antigène Ovalbumine. Nous avons démontré qu'un grand nombre de lymphocytes Τ CD8+ OT-3 ne sont pas éliminés lors de la sélection négative dans le thymus après avoir rencontré l'antigène du soi. Par conséquent, les lymphocytes Τ OT-3 de faible avidité sont présents dans une fenêtre de sélection comprise entre la sélection positive et négative. Cette limite se définie comme le seuil d'affinité et est impliquée dans l'échappement de certains lymphocytes Τ OT- 3 autoréactifs. A la périphérie, ces cellules sont capables d'induire une autoimmunité après stimulation au cours d'une infection, ce qui nous permet de les définir comme étant non tolérante et non dans un état anergique à la périphérie. Nous avons également étudié le seuil d'activation des lymphocytes Τ OT-3 à faible avidité à la périphérie et avons constaté que des ligands peptidiques plus faibles que l'épitope natif SIINFEKL sont capables de les activer au cours d'une infection ainsi que de les différencier en lymphocytes Τ effecteurs et mémoires. Les données illustrent une déficience lors de la sélection négative dans le thymus de lymphocytes Τ CD8+ autoréactifs de faible avidité contre un antigène du soi spécifique à tissu et montrent que ces cellules sont entièrement compétentes lors d'une infection. - The diverse Τ cell repertoire needs to be tolerant to self-antigen to avoid the induction of autoimmunity. This is why autoreactive developing Τ cells are deleted in the thymus. The deletion of self-reactive Τ cells occurs through the process of negative selection. Most studies investigated high avidity Τ cells. These high avidity Τ cells are very sensitive and strongly react to a self-antigen. As a consequence, these cells induce the development of autoimmunity when they target organs which express the self-antigen. High avidity autoreactive CD8+ Τ cells are deleted in the thymus. However, several studies have shown Τ cells that weakly respond to tissue-restricted antigen, referred to as low avidity Τ cells, can bypass central and peripheral tolerance mechanisms. I used Rip-mOva mice that expressed Ovalbumin as a neo self-antigen in a tissue-restricted fashion. In these transgenic Rip-mOva mice low avidity CD8+ Τ cells survive negative selection. Upon stimulation in the periphery, these low avidity CD8+ Τ cells have the ability to infiltrate organs that express the self-antigen in the Rip-mOva mice and can also induce the destruction of the tissue. The major aim of my PhD project was to understand the phenotypic and functionality characteristics of these Τ cells in a steady-state condition and in a context of an infection. To study these cells in a well-defined mouse model, we generated OT-3 Τ cell receptor transgenic mice that express low avidity CD8+ Τ cells that are specific for the SIINFEKL epitope of the Ovalbumin antigen. We have been able to demonstrate that a large number of OT-3 CD8+ Τ cells survive negative selection in the thymus after encountering the self-antigen. Thus, low avidity OT-3 Τ cells are present in a window of selection comprised between positive and negative selection. This boundary defined as the affinity threshold is involved in the escape of some autoreactive low avidity OT-3 Τ cells. Once they circulate in the periphery, they are able to induce autoimmunity after stimulation during an infection, allowing us to allocate these cells as being non-tolerant and not in an anergic state in the periphery. We have also looked at the threshold of activation of low avidity OT-3 CD8+ Τ cells in the periphery and found that peptide ligands that are weaker than the native SIINFEKL epitope are able to activate OT-3 Τ cells during an infection and to differentiate them into effector and memory Τ cells. The data illustrate the impairment of negatively selecting low avidity autoreactive CD8+ Τ cells against a tissue-restricted antigen in the thymus and shows that these cells are fully competent upon an infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the study of a large American family displaying autosomal dominant retinitis pigmentosa with reduced penetrance, a form of hereditary retinal degeneration. Although the inheritance pattern and previous linkage mapping pointed to the involvement of the PRPF31 gene, extensive screening of all its exons and their boundaries failed in the past to reveal any mutation. In this work, we sequenced the entire PRPF31 genomic region by both the classical Sanger method and ultrahigh throughput (UHT) sequencing. Among the many variants identified, a single-base substitution (c.1374+654C>G) located deep within intron 13 and inside a repetitive DNA element was common to all patients and obligate asymptomatic carriers. This change created a new splice donor site leading to the synthesis of two mutant PRPF31 isoforms, degraded by nonsense-mediated mRNA decay. As a consequence, amounts of PRPF31 mRNA derived from the mutant allele were very reduced, with no evidence of mutant proteins being synthesized. Our results indicate that c.1374+654C>G causes retinitis pigmentosa via haploinsufficiency, similar to the vast majority of PRPF31 mutations described so far. We discuss the potential of UHT sequencing technologies in mutation screening and the continued identification of pathogenic splicing mutations buried deep within intronic regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic brain injury (TBI) is recognized as a cause of hypopituitarism even after mild TBI. Although over the past decade, a growing body of research has detailed neuroendocrine changes induced by TBI, the mechanisms and risk factors responsible for this pituitary dysfunction are still unclear. Around the world, sports-especially combative sports-are very popular. However, sports are not generally considered as a cause of TBI in most epidemiological studies, and the link between sports-related head trauma and hypopituitarism has not been investigated until recently. Thus, there is a paucity of data regarding this important concern. Because of the large number of young sports participants with near-normal life expectancy, the implications of undiagnosed or untreated postconcussion pituitary dysfunction can be dramatic. Understanding the pathophysiological mechanisms and risk factors of hypopituitarism caused by sports injuries is thus an important issue that concerns both medical staff and sponsors of sports. The aim of this paper was to summarize the best evidence for understanding the pathophysiological mechanisms and to discuss the current data and recommendations on sports-related head trauma as a cause of hypopituitarism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in daily clinical practice. However, little is known about its clinical utility such as image quality, safety and impact on patient management. In addition, there is limited information about the potential of CMR to acquire prognostic information. METHODS: The European Cardiovascular Magnetic Resonance Registry (EuroCMR Registry) will consist of two parts: 1) Multicenter registry with consecutive enrolment of patients scanned in all participating European CMR centres using web based online case record forms. 2) Prospective clinical follow up of patients with suspected coronary artery disease (CAD) and hypertrophic cardiomyopathy (HCM) every 12 months after enrolment to assess prognostic data. CONCLUSION: The EuroCMR Registry offers an opportunity to provide information about the clinical utility of routine CMR in a large number of cases and a diverse population. Furthermore it has the potential to gather information about the prognostic value of CMR in specific patient populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether different brain networks are involved in generating unimanual responses to a simple visual stimulus presented in the ipsilateral versus contralateral hemifield remains a controversial issue. Visuo-motor routing was investigated with event-related functional magnetic resonance imaging (fMRI) using the Poffenberger reaction time task. A 2 hemifield x 2 response hand design generated the "crossed" and "uncrossed" conditions, describing the spatial relation between these factors. Both conditions, with responses executed by the left or right hand, showed a similar spatial pattern of activated areas, including striate and extrastriate areas bilaterally, SMA, and M1 contralateral to the responding hand. These results demonstrated that visual information is processed bilaterally in striate and extrastriate visual areas, even in the "uncrossed" condition. Additional analyses based on sorting data according to subjects' reaction times revealed differential crossed versus uncrossed activity only for the slowest trials, with response strength in infero-temporal cortices significantly correlating with crossed-uncrossed differences (CUD) in reaction times. Collectively, the data favor a parallel, distributed model of brain activation. The presence of interhemispheric interactions and its consequent bilateral activity is not determined by the crossed anatomic projections of the primary visual and motor pathways. Distinct visuo-motor networks need not be engaged to mediate behavioral responses for the crossed visual field/response hand condition. While anatomical connectivity heavily influences the spatial pattern of activated visuo-motor pathways, behavioral and functional parameters appear to also affect the strength and dynamics of responses within these pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the benefits of a low-dose stimulation (LDS) protocol with purified urinary follicle-stimulating hormone in patients with polycystic ovaries who have presented previously with a very high ovarian response to a standard hMG stimulation. DESIGN: Cohort study. SETTING: Fertility center in a university hospital. PATIENT(S): Sixty-one patients involved in an IVF/ICSI program from January 1995 to December 1996. INTERVENTION(S): The patients were first stimulated with a standard protocol using hMG and presented with a very high ovarian response. These patients were then stimulated a second time using a low-dose protocol. Cryopreserved embryos were transferred in later artificial or natural cycles until to December 1999. MAIN OUTCOME MEASURE(S): Number of gonadotropin ampules; estradiol level on the day of ovulation induction; follicles, oocytes, and cryopreserved zygotes; fertilization, implantation, and pregnancy rates; and number of ovarian hyperstimulation syndromes (OHSS). RESULT(S): The number of ampules used, the estradiol level reached, and the number of oocytes obtained were significantly lower under the LDS than the standard protocol. High implantation (21.8%) and clinical pregnancy (38.4%) rates were obtained after LDS. The cumulated deliveries per cycle started and per patient were, respectively, 41.6% and 52.5%. Five patients suffered OHSS with the standard protocol, and none with the LDS. CONCLUSION(S): The LDS protocol offers a safe and efficient treatment for patients who present with echographic polycystic ovaries and are at risk of an excessive ovarian response to standard IVF stimulation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IL-2 immunotherapy is an attractive treatment option for certain metastatic cancers. However, administration of IL-2 to patients can lead, by ill-defined mechanisms, to toxic adverse effects including severe pulmonary edema. Here, we show that IL-2-induced pulmonary edema is caused by direct interaction of IL-2 with functional IL-2 receptors (IL-2R) on lung endothelial cells in vivo. Treatment of mice with high-dose IL-2 led to efficient expansion of effector immune cells expressing high levels of IL-2Rbetagamma, including CD8(+) T cells and natural killer cells, which resulted in a considerable antitumor response against s.c. and pulmonary B16 melanoma nodules. However, high-dose IL-2 treatment also affected immune cell lineage marker-negative CD31(+) pulmonary endothelial cells via binding to functional alphabetagamma IL-2Rs, expressed at low to intermediate levels on these cells, thus causing pulmonary edema. Notably, IL-2-mediated pulmonary edema was abrogated by a blocking antibody to IL-2Ralpha (CD25), genetic disruption of CD25, or the use of IL-2Rbetagamma-directed IL-2/anti-IL-2 antibody complexes, thereby interfering with IL-2 binding to IL-2Ralphabetagamma(+) pulmonary endothelial cells. Moreover, IL-2/anti-IL-2 antibody complexes led to vigorous activation of IL-2Rbetagamma(+) effector immune cells, which generated a dramatic antitumor response. Thus, IL-2/anti-IL-2 antibody complexes might improve current strategies of IL-2-based tumor immunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To implement and characterize a fluorine-19 ((19)F) magnetic resonance imaging (MRI) technique and to test the hypothesis that the (19)F MRI signal in steady state after intravenous injection of a perfluoro-15-crown-5 ether (PCE) emulsion may be exploited for angiography in a pre-clinical in vivo animal study. MATERIALS AND METHODS: In vitro at 9.4T, the detection limit of the PCE emulsion at a scan time of 10 min/slice was determined, after which the T(1) and T(2) of PCE in venous blood were measured. Permission from the local animal use committee was obtained for all animal experiments. 12 µl/g of PCE emulsion was intravenously injected in 11 mice. Gradient echo (1)H and (19)F images were obtained at identical anatomical levels. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined for 33 vessels in both the (19)F and (1)H images, which was followed by vessel tracking to determine the vessel conspicuity for both modalities. RESULTS: In vitro, the detection limit was ∼400 µM, while the (19)F T(1) and T(2) were 1350±40 and 25±2 ms. The (19)F MR angiograms selectively visualized the vasculature (and the liver parenchyma over time) while precisely coregistering with the (1)H images. Due to the lower SNR of (19)F compared to (1)H (17±8 vs. 83±49, p<0.001), the (19)F CNR was also lower at 15±8 vs. 52±35 (p<0.001). Vessel tracking demonstrated a significantly higher vessel sharpness in the (19)F images (66±11 vs. 56±12, p = 0.002). CONCLUSION: (19)F magnetic resonance angiography of intravenously administered perfluorocarbon emulsions is feasible for a selective and exclusive visualization of the vasculature in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular magnetic resonance (CMR) has become an established imaging modality which provides often unique information on a wide range of cardiovascular diseases. The European Society of Cardiology (ESC) training curriculum reflects the emerging role of CMR by recommending that all trainees obtain a minimum level of training in CMR and by defining criteria for subspecialty training in CMR. 1 The wider use of CMR requires the definition of standards for data acquisition, reporting, and training in CMR across Europe. At the same time, training and accreditation in all cardiac imaging methods should be harmonized and integrated to promote the training of cardiac imaging specialists. The recommendations presented in this document are intended to inform the discussion about standards for accreditation and certification in CMR in Europe and the discussion on integrated imaging training. At present, the recommendations in this position statement are not to be interpreted as guidelines. Until such guidelines are available and nationally ratified, physicians will be able to train and practice CMR according to current national regulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

l'imagerie par résonance magnétique (IRMC) est une technologie utilisée depuis les aimées quatre¬-vingts dans le monde de la cardiologie. Cette technique d'imagerie non-invasive permet d'acquérir Ses images du coeur en trois dimensions, dans n'importe quel, plan, sans application de radiation, et en haute résolution. Actuellement, cette technique est devenue un référence dans l'évaluation et 'l'investigation de différentes pathologies cardiaques. La morphologie cardiaque, la fonction des ventricules ainsi que leur contraction, la perfusion tissulaire ainsi que la viabilité tissulaire peuvent être caractérisés en utilisant différentes séquences d'imagerie. Cependant, cette technologie repose sur des principes physiques complexes et la mise en pratique de cette technique se heurte à la difficulté d'évaluer un organe en mouvement permanent. L'IRM cardiaque est donc sujette à différents artefacts qui perturbent l'interprétation des examens et peuvent diminuer la précision diagnostique de cette technique. A notre connaissance, la plupart des images d'IRMC sont analysées et interprétées sans évaluation rigoureuse de la qualité intrinsèque de l'examen. Jusqu'à présent, et à notre connaissance, aucun critère d'évaluation de la qualité des examens d'IRMC n'a été clairement déterminé. L'équipe d'IRMC du CHUV, dirigée par le Prof J. Schwitter, a recensé une liste de 35 critères qualitatifs et 12 critères quantitatifs évaluant la qualité d'un examen d'IRMC et les a introduit dans une grille d'évaluation. L'objet de cette étude est de décrire et de valider la reproductibilité des critères figurant dans cette grille d'évaluation, par l'interprétation simultanée d'examens IRMC par différents observateurs (cardiologues spécialisés en IRM, étudiant en médecine, infirmière spécialisée). Notre étude a permis de démontrer que les critères définis pour l'évaluation des examens d'IRMC sont robustes, et permettent une bonne reproductibilité intra- et inter-observateurs. Cette étude valide ainsi l'utilisation de ces critères de qualité dans le cadre de l'imagerie par résonance magnétique cardiaque. D'autres études sont encore nécessaires afin de déterminer l'impact de la qualité de l'image sur la précision diagnostique de cette technique. Les critères standardisés que nous avons validés seront utilisés pour évaluer la qualité des images dans le cadre d'une étude à échelle européenne relative à l'IRMC : "l'EuroCMR registry". Parmi les autres utilités visées par ces critères de qualité, citons notamment la possibilité d'avoir une référence d'évaluation de la qualité d'examen pour toutes les futures études cliniques utilisant la technologie d'IRMC, de permettre aux centres d'IRMC de quantifier leur niveau de qualité, voire de créer un certificat de standard de qualité pour ces centres, d'évaluer la reproductibilité de l'évaluation des images par différents observateurs d'un même centre, ou encore d'évaluer précisément la qualité des séquences développées à l'avenir dans le monde de l'IRMC.