914 resultados para Rating Bridges
Resumo:
Restoring old buildings to conform the current building policies and standards is a great challenge to engineers and architects. The restoration of the Brisbane City Hall, a heritage building listed by the State of Queensland in Australia, developed an innovative approach to upgrade the building using the method called ‘concrete overlay’ following the guidelines of both the International Council on Monuments and Sites and the Burra Charter of Australia. Concrete overlay is a new method of structural strengthening by drilling new reinforcement and placing new concrete on top of the existing structure, akin to a bone transplant or bone grafting in the case of a human being. This method is popularly used for newer bridges which have suffered load stresses. However, this method had never been used on any heritage buildings which were built on different conditions and standards. The compatibility of this method is currently being monitored. Most of the modern historic buildings are rapidly deteriorating and require immediate interventions in order to be saved. As most of these heritage buildings are on the stage of advanced deterioration, significant attempts are being made and several innovations are being applied to upgrade these structures to conform with the current building requirements. To date, the knowledge and literature in regarding ‘concrete cancer’ in relation to rehabilitating these reinforced concrete heritage structures is significantly lacking. It is hoped that the method of concrete overlay and the case study of Brisbane City Hall restoration will contribute to the development of restoration techniques and policies for Modern Heritage Buildings.
Resumo:
Cold-formed steel lipped channels are commonly used in LSF wall construction as load bearing studs with plasterboards on both sides. Under fire conditions, cold-formed thin-walled steel sections heat up quickly resulting in fast reduction in their strength and stiffness. Usually the LSF wall panels are subjected to fire from one side which will cause thermal bowing, neutral axis shift and magnification effects due to the development of non-uniform temperature distributions across the stud. This will induce an additional bending moment in the stud and hence the studs in LSF wall panels should be designed as a beam column considering both the applied axial compression load and the additional bending moment. Traditionally the fire resistance rating of these wall panels is based on approximate prescriptive methods. Very often they are limited to standard wall configurations used by the industry. Therefore a detailed research study is needed to develop fire design rules to predict the failure load and hence the failure time of LSF wall panels subject to non-uniform temperature distributions. This paper presents the details of an investigation to develop suitable fire design rules for LSF wall studs under non-uniform elevated temperature distributions. Applications of the previously developed fire design rules based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 to LSF wall studs were investigated in detail and new simplified fire design rules based on AS/NZS 4600 and Eurocode 3 Part 1.3 were proposed in the current study with suitable allowances for the interaction effects of compression and bending actions. The accuracy of the proposed fire design rules was verified by using the results from full scale fire tests and extensive numerical studies.
Resumo:
Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.
Resumo:
Light Gauge Steel Framing (LSF) walls are made of cold-formed, thin-walled steel lipped channel studs with plasterboard linings on both sides. However, these thin-walled steel sections heat up quickly and lose their strength under fire conditions despite the protection provided by plasterboards. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. A research study using both fire tests and numerical studies was undertaken to investigate the structural and thermal behaviour of load bearing LSF walls made of both conventional and the new composite panels under standard fire conditions and to determine their fire resistance rating. This paper presents the details of finite element models of LSF wall studs developed to simulate the structural performance of LSF wall panels under standard fire conditions. Finite element analyses were conducted under both steady and transient state conditions using the time-temperature profiles measured during the fire tests. The developed models were validated using the fire test results of 11 LSF wall panels with various plasterboard/insulation configurations and load ratios. They were able to predict the fire resistance rating within five minutes. The use of accurate numerical models allowed the inclusion of various complex structural and thermal effects such as local buckling, thermal bowing and neutral axis shift that occurred in thin-walled steel studs under non-uniform elevated temperature conditions. Finite element analyses also demonstrated the improvements offered by the new composite panel system over the conventional cavity insulated system.
Resumo:
Traditionally the fire resistance rating of LSF wall systems is based on approximate prescriptive methods developed using limited fire tests. Therefore a detailed research study into the performance of load bearing LSF wall systems under standard fire conditions was undertaken to develop improved fire design rules. It used the extensive fire performance results of eight different LSF wall systems from a series of full scale fire tests and numerical studies for this purpose. The use of previous fire design rules developed for LSF walls subjected to non-uniform elevated temperature distributions based on AISI design manual and Eurocode3 Parts 1.2 and 1.3 was investigated first. New simplified fire design rules based on AS/NZS 4600, North American Specification and Eurocode 3 Part 1.3 were then proposed in this study with suitable allowances for the interaction effects of compression and bending actions. The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated. A spread sheet based design tool was developed based on the new design rules to predict the failure load ratio versus time and temperature curves for varying LSF wall configurations. The accuracy of the proposed design rules was verified using the test and FEA results for different wall configurations, steel grades, thicknesses and load ratios. This paper presents the details and results of this study including the improved fire design rules for predicting the load capacity of LSF wall studs and the failure times of LSF walls under standard fire conditions.
Resumo:
Background: The Vulnerable Elders Survey-13 (VES-13) is increasingly used to screen for older patients who can proceed to intensive chemotherapy without further comprehensive assessment. This study compared the VES-13 determination of fitness for treatment with the oncologist's assessments of fitness. Method: Sample: Consecutive series of solid tumour patients ≥65 years (n=175; M=72; range=65-86) from an Australian cancer centre. Patients were screened with the VES-13 before proceeding to usual treatment. Blinded to screening, oncologists concurrently predicted patient fitness for chemotherapy. A sample of 175 can detect, with 90% power, kappa coefficients of agreement between VES-13 and oncologists’ assessments >0.90 ("almost perfect agreement"). Separate backward stepwise logistic regression analyses assessed potential predictors of VES-13 and oncologists’ ratings of fitness. Results: Kappa coefficient for agreement between VES-13 and oncologists’ ratings of fitness was 0.41 (p<0.001). VES-13 and oncologists’ assessments agreed in 71% of ratings. VES-13 sensitivity = 83.3%; specificity = 57%; positive predictive value = 69%; negative predictive value = 75%. Logistic regression modelling indicated that the odds of being vulnerable to chemotherapy (VES-13) increased with increasing depression (OR=1.42; 95% CI: 1.18, 1.71) and decreased with increased functional independence assessed on the Bartel Index (OR=0.82; CI: 0.74, 0.92) and Lawton instrumental activities of daily living (OR=0.44; CI: 0.30, 0.65); RSquare=.65. Similarly, the odds of a patient being vulnerable to chemotherapy, when assessed by physicians, increased with increasing age (OR=1.15; CI: 1.07, 1.23) and depression (OR=1.23; CI: 1.06, 1.43), and decreased with increasing functional independence (OR=0.91; CI: 0.85, 0.98); RSquare=.32. Conclusions: Our data indicate moderate agreement between VES-13 and clinician assessments of patients’ fitness for chemotherapy. Current ‘one-step’ screening processes to determine fitness have limits. Nonetheless, screening tools do have the potential for modification and enhanced predictive properties in cancer care by adding relevant items, thus enabling fit patients to be immediately referred for chemotherapy.
Resumo:
Background There is growing consensus that a multidisciplinary, comprehensive and standardised process for assessing the fitness of older patients for chemotherapy should be undertaken to determine appropriate cancer treatment. Aim This study tested a model of cancer care for the older patient incorporating Comprehensive Geriatric Assessment (CGA), which aimed to ensure that 'fit' individuals amenable to active treatment were accurately identified; 'vulnerable' patients more suitable for modified or supportive regimens were determined; and 'frail 'individuals who would benefit most from palliative regimens were also identified and offered the appropriate level of care. Methods A consecutive-series n=178 sample of patients >65 years was recruited from a major Australian cancer centre. The following instruments were administered by an oncogeriatric nurse prior to treatment: Vulnerable Elders Survey-13; Cumulative Illness Rating Scale (Geriatric); Malnutrition Screening Tool; Mini-mental State Examination; Geriatric Depression Scale; Barthel Index; and Lawton Instrumental Activities of Daily Living Scale. Scores from these instruments were aggregated to predict patient fitness, vulnerability or frailty for chemotherapy. Physicians provided a concurrent (blinded) prediction of patient fitness, vulnerability or frailty based on their clinical assessment. Data were also collected on actual patient outcomes (eg treatment completed as predicted, treatment reduced) during monthly audits of patient trajectories. Data analysis Data analysis is underway. A sample of 178 is adequate to detect, with 90% power, kappa coefficients of agreement between CGA and physician assessments of K>0.90 ("almost perfect agreement"). Primary endpoints comprise a) whether the nurse-led CGA determination of fit, vulnerable or frail agrees with the oncologist's assessments of fit, vulnerable or frail and b) whether the CGA and physician assessments accurately predict actual patient outcomes. Conclusion An oncogeriatric nurse-led model of care is currently being developed from the results. We conclude with a discussion of the pivotal role of nurses in CGA-based models of care.
Resumo:
Cold–formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.
Resumo:
This research is part of a major project with a stimulus that rose from the need to manage a large number of ageing bridges in low traffic volume roads (LTVR) in Australia. The project investigated, designed and consequently constructed, involved replacing an ageing super-structure of a 10m span bridge with a disused Flat-bed Rail Wagon (FRW). This research, therefore, is developed on the premises that the FRW can be adopted as the main structural system for the bridges in LTVR network. The main focus of this research is to present two alternate deck wearing systems (DWS) as part of the design of the FRW as road bridge deck conforming to AS5100 (2004). The bare FRW structural components were first examined for their adequacy (ultimate and serviceability) in resisting the critical loads specified in AS5100(2004). Two options of DWSs were evaluated and their effects on the FRW examined. The first option involved usage of timber DWS; the idea of this option was to use all the primary and secondary members of the FRW in load sharing and to provide additional members where weaknesses in the original members arose. The second option involved usage of reinforced concrete DWS with only the primary members of the FRW sharing the AS5100 (2004) loading. This option inherently minimised the risk associated with any uncertainty of the secondary members to their structural adequacy. This thesis reports the design phases of both options with conclusions of the selection of the ideal option for better structural performance, ease of construction and cost. The comparison carried out here focuses on the distribution of the traffic load by the FRW as a superstructure. Advantages and disadvantages highlighting cost comparisons and ease of constructability of the two systems are also included.
Resumo:
Despite its potential multiple contributions to sustainable policy objectives, urban transit is generally not widely used by the public in terms of its market share compared to that of automobiles, particularly in affluent societies with low-density urban forms like Australia. Transit service providers need to attract more people to transit by improving transit quality of service. The key to cost-effective transit service improvements lies in accurate evaluation of policy proposals by taking into account their impacts on transit users. If transit providers knew what is more or less important to their customers, they could focus their efforts on optimising customer-oriented service. Policy interventions could also be specified to influence transit users’ travel decisions, with targets of customer satisfaction and broader community welfare. This significance motivates the research into the relationship between urban transit quality of service and its user perception as well as behaviour. This research focused on two dimensions of transit user’s travel behaviour: route choice and access arrival time choice. The study area chosen was a busy urban transit corridor linking Brisbane central business district (CBD) and the St. Lucia campus of The University of Queensland (UQ). This multi-system corridor provided a ‘natural experiment’ for transit users between the CBD and UQ, as they can choose between busway 109 (with grade-separate exclusive right-of-way), ordinary on-street bus 412, and linear fast ferry CityCat on the Brisbane River. The population of interest was set as the attendees to UQ, who travelled from the CBD or from a suburb via the CBD. Two waves of internet-based self-completion questionnaire surveys were conducted to collect data on sampled passengers’ perception of transit service quality and behaviour of using public transit in the study area. The first wave survey is to collect behaviour and attitude data on respondents’ daily transit usage and their direct rating of importance on factors of route-level transit quality of service. A series of statistical analyses is conducted to examine the relationships between transit users’ travel and personal characteristics and their transit usage characteristics. A factor-cluster segmentation procedure is applied to respodents’ importance ratings on service quality variables regarding transit route preference to explore users’ various perspectives to transit quality of service. Based on the perceptions of service quality collected from the second wave survey, a series of quality criteria of the transit routes under study was quantitatively measured, particularly, the travel time reliability in terms of schedule adherence. It was proved that mixed traffic conditions and peak-period effects can affect transit service reliability. Multinomial logit models of transit user’s route choice were estimated using route-level service quality perceptions collected in the second wave survey. Relative importance of service quality factors were derived from choice model’s significant parameter estimates, such as access and egress times, seat availability, and busway system. Interpretations of the parameter estimates were conducted, particularly the equivalent in-vehicle time of access and egress times, and busway in-vehicle time. Market segmentation by trip origin was applied to investigate the difference in magnitude between the parameter estimates of access and egress times. The significant costs of transfer in transit trips were highlighted. These importance ratios were applied back to quality perceptions collected as RP data to compare the satisfaction levels between the service attributes and to generate an action relevance matrix to prioritise attributes for quality improvement. An empirical study on the relationship between average passenger waiting time and transit service characteristics was performed using the service quality perceived. Passenger arrivals for services with long headways (over 15 minutes) were found to be obviously coordinated with scheduled departure times of transit vehicles in order to reduce waiting time. This drove further investigations and modelling innovations in passenger’ access arrival time choice and its relationships with transit service characteristics and average passenger waiting time. Specifically, original contributions were made in formulation of expected waiting time, analysis of the risk-aversion attitude to missing desired service run in the passengers’ access time arrivals’ choice, and extensions of the utility function specification for modelling passenger access arrival distribution, by using complicated expected utility forms and non-linear probability weighting to explicitly accommodate the risk of missing an intended service and passenger’s risk-aversion attitude. Discussions on this research’s contributions to knowledge, its limitations, and recommendations for future research are provided at the concluding section of this thesis.
Resumo:
The dc capacitors voltage unbalancing is the main technical drawback of a diode-clamped multilevel inverter (DCMLI), with more than three levels. A voltage-balancing circuit based on buck–boost chopper connected to the dc link of DCMLI is a reliable and robust solution to this problem. This study presents four different schemes for controlling the chopper circuit to achieve the capacitor voltages equalisation. These can be broadly categorised as single-pulse, multi-pulse and hysteresis band current control schemes. The single-pulse scheme does not involve faster switching actions but need the chopper devices to be rated for higher current. The chopper devices current rating can be kept limited by using the multi-pulse scheme but it involves faster switching actions and slower response. The hysteresis band current control scheme offers faster dynamics, lower current rating of the chopper devices and can nullify the initial voltage imbalance as well. However, it involves much faster switching actions which may not be feasible for some of its applications. Therefore depending on the system requirements and ratings, one of these schemes may be used. The performance and validity of the proposed schemes are confirmed through both simulation and experimental investigations on a prototype five-level diode-clamped inverter.
Resumo:
Background: Medication remains the cornerstone treatment for mental illness. Cognition is one of the strongest predictors of non-adherence. The aim of this preliminary investigation was to examine the association between the Large Allen Cognitive Level Screen (LACLS) and medication adherence among a small sample of mental health service users to determine whether the LACLS has potential as a screening tool for capacity to manage medication regimens. Method: Demographic and clinical information was collected from a small sample of people who had recently accessed community mental health services. Participants then completed the LACLS and the Medication Adherence Rating Scale (MARS) at a single time point. The strength of association between the LACLS and MARS was examined using Spearman rank-order correlation. Results: A strong positive correlation between the LACLS and medication adherence (r = 0.71, p = 0.01) was evident. No participants reported the use of medication aids despite evidence of impaired cognitive functioning. Conclusion: This investigation has provided the first empirical evidence indicating that the LACLS may have utility as a screening instrument for capacity to manage medication adherence among this population. While promising, this finding should be interpreted with caveats given its preliminary nature.
Resumo:
In recent times, fire has become a major disaster in buildings due to the increase in fire loads, as a result of modern furniture and light weight construction. This has caused problems for safe evacuation and rescue activities, and in some instances lead to the collapse of buildings (Lewis, 2008 and Nyman, 2002). Recent research has shown that the actual fire resistance of building elements exposed to building fires can be less than their specified fire resistance rating (Lennon and Moore, 2003, Jones, 2002, Nyman, 2002 and Abecassis-Empis et al. 2008). Conventionally the fire rating of building elements is determined using fire tests based on the standard fire time-temperature curve given in ISO 834. This ISO 834 curve was developed in the early 1900s, where wood was the basic fuel source. In reality, modern buildings make use of thermoplastic materials, synthetic foams and fabrics. These materials are high in calorific values and increase both the speed of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Hence it suggests the need to use realistic fire time-temperature curves in tests. Real building fire temperature profiles depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials. Fuel load is selected based on a review and suitable realistic fire time-temperature curves were developed. Fire tests were then performed for plasterboard lined light gauge steel framed walls for the developed realistic fire curves. This paper presents the details of the development of suitable realistic building fire curves, and the fire tests using them. It describes the fire performance of tested walls in comparison to the standard fire tests and highlights the differences between them. This research has shown the need to use realistic fire exposures in assessing the fire resistance rating of building elements.
Resumo:
The increasing prevalence of obesity in society has been associated with a number of atherogenic risk factors such as insulin resistance. Aerobic training is often recommended as a strategy to induce weight loss, with a greater impact of high-intensity levels on cardiovascular function and insulin sensitivity, and a greater impact of moderate-intensity levels on fat oxidation. Anaerobic high-intensity (supramaximal) interval training has been advocated to improve cardiovascular function, insulin sensitivity and fat oxidation. However, obese individuals tend to have a lower tolerance of high-intensity exercise due to discomfort. Furthermore, some obese individuals may compensate for the increased energy expenditure by eating more and/or becoming less active. Recently, both moderate- and high-intensity aerobic interval training have been advocated as alternative approaches. However, it is still uncertain as to which approach is more effective in terms of increasing fat oxidation given the issues with levels of fitness and motivation, and compensatory behaviours. Accordingly, the objectives of this thesis were to compare the influence of moderate- and high-intensity interval training on fat oxidation and eating behaviour in overweight/obese men. Two exercise interventions were undertaken by 10-12 overweight/obese men to compare their responses to study variables, including fat oxidation and eating behaviour during moderate- and high-intensity interval training (MIIT and HIIT). The acute training intervention was a methodological study designed to examine the validity of using exercise intensity from the graded exercise test (GXT) - which measured the intensity that elicits maximal fat oxidation (FATmax) - to prescribe interval training during 30-min MIIT. The 30-min MIIT session involved 5-min repetitions of workloads 20% below and 20% above the FATmax. The acute intervention was extended to involve HIIT in a cross-over design to compare the influence of MIIT and HIIT on eating behaviour using subjective appetite sensation and food preference through the liking and wanting test. The HIIT consisted of 15-sec interval training at 85 %VO2peak interspersed by 15-sec unloaded recovery, with a total mechanical work equal to MIIT. The medium term training intervention was a cross-over 4-week (12 sessions) MIIT and HIIT exercise training with a 6-week detraining washout period. The MIIT sessions consisted of 5-min cycling stages at ±20% of mechanical work at 45 %VO2peak, and the HIIT sessions consisted of repetitive 30-sec work at 90 %VO2peak and 30-sec interval rests, during identical exercise sessions of between 30 and 45 mins. Assessments included a constant-load test (45 %VO2peak for 45 mins) followed by 60-min recovery at baseline and the end of 4-week training, to determine fat oxidation rate. Participants’ responses to exercise were measured using blood lactate (BLa), heart rate (HR) and rating of perceived exertion (RPE) and were measured during the constant-load test and in the first intervention training session of every week during training. Eating behaviour responses were assessed by measuring subjective appetite sensations, liking and wanting and ad libitum energy intake. Results of the acute intervention showed that FATmax is a valid method to estimate VO2 and BLa, but is not valid to estimate HR and RPE in the MIIT session. While the average rate of fat oxidation during 30-min MIIT was comparable with the rate of fat oxidation at FATmax (0.16 ±0.09 and 0.14 ±0.08 g/min, respectively), fat oxidation was significantly higher at minute 25 of MIIT (P≤0.01). In addition, there was no significant difference between MIIT and HIIT in the rate of appetite sensations after exercise, but there was a tendency towards a lower rate of hunger after HIIT. Different intensities of interval exercise also did not affect explicit liking or implicit wanting. Results of the medium-term intervention indicated that current interval training levels did not affect body composition, fasting insulin and fasting glucose. Maximal aerobic capacity significantly increased (P≤0.01) (2.8 and 7.0% after MIIT and HIIT respectively) during GXT, and fat oxidation significantly increased (P≤0.01) (96 and 43% after MIIT and HIIT respectively) during the acute constant-load exercise test. RPE significantly decreased after HIIT greater than MIIT (P≤0.05), and the decrease in BLa was greater during the constant-load test after HIIT than MIIT, but this difference did not reach statistical significance (P=0.09). In addition, following constant-load exercise, exercise-induced hunger and desire to eat decreased after HIIT greater than MIIT but were not significant (p value for desire to eat was 0.07). Exercise-induced liking of high-fat sweet (HFSW) and high-fat non-sweet (HFNS) foods increased after MIIT and decreased after HIIT (p value for HFNS was 0.09). The intervention explained 12.4% of the change in fat intake (p = 0.07). This research is significant in that it confirmed two points in the acute study. While the rate of fat oxidation increased during MIIT, the average rate of fat oxidation during 30-min MIIT was comparable with the rate of fat oxidation at FATmax. In addition, manipulating the intensity of acute interval exercise did not affect appetite sensations and liking and wanting. In the medium-term intervention, constant-load exercise-induced fat oxidation significantly increased after interval training, independent of exercise intensity. In addition, desire to eat, explicit liking for HFNS and fat intake collectively confirmed that MIIT is accompanied by a greater compensation of eating behaviour than HIIT. Findings from this research will assist in developing exercise strategies to provide obese men with various training options. In addition, the finding that overweight/obese men expressed a lower RPE and decreased BLa after HIIT compared with MIIT is contrary to the view that obese individuals may not tolerate high-intensity interval training. Therefore, high-intensity interval training can be advocated among the obese adult male population. Future studies may extend this work by using a longer-term intervention.
Resumo:
In recent years, with the impact of global knowledge economy, a more comprehensive development approach has gained significant popularity. This new development approach, so called ‘knowledge-based urban development’, is different from its traditional predecessor. With a much more balanced focus on all of the four key development domains – economic, spatial, institutional, and socio-cultural – this contemporary approach, aims to bring economic prosperity, environmental sustainability and local institutional competence with a just socio-spatial order to our cities and regions. The ultimate goal of knowledgebased urban development is to produce a city purposefully designed to encourage the continuous production, circulation and commercialization of social and scientific knowledge – this will in turn establish a ‘knowledge city’. A city following the ‘knowledge city’ concept embarks on a strategic mission to firmly encourage and nurture locally focused innovation, science and creativity within the context of an expanding knowledge economy and society. In this regard a ‘knowledge city’ can be seen as an integrated city, which physically and institutionally combines the functions of a science and technology park with civic and residential functions and urban amenities. It also offers one of the effective paradigms for the sustainable cities of our time. This sixth edition of KCWS – The 6th Knowledge Cities World Summit 2013 – makes an important reminder that the ‘knowledge city’ concept is a key notion in the 21st Century development. Considering this notion, the Summit sheds light on the multifaceted dimensions and various scales of building a ‘knowledge city’ via ‘knowledge-based urban development’ paradigm by particularly focusing on the overall Summit theme of ‘Establishing Bridges’. At this summit, the theoretical and practical maturing of knowledge-based development paradigms are advanced through the interplay between the world’s leading academics’ theories and the practical models and strategies of practitioners’ and policy makers’ drawn from around the world. This summit proceeding is compiled in order to disseminate the knowledge generated and shared in KCWS 2013 with the wider research, governance, and practice communities the knowledge co-created in this summit. All papers of this proceeding have gone through a double-blind peer review process and been reviewed by our summit editorial review and advisory board members. We, organizers of the summit, cordially thank the members of the Summit Proceeding Editorial Review and Advisory Board for their diligent work in the review of the papers. Also we thank Prof.Dr. Ahmet Ademoğlu, Rector of İstanbul Şehir University, for providing all the support for the Summit. We hope the papers in this proceeding will inspire and make a significant contribution to the research, governance, and practice circles.