921 resultados para Radiochemical laboratories
Resumo:
This paper describes the development of a mechatronic system for a predictive maintenance grounded on wear particle analysis. The reckoning of wear particles containing in lubricating industrial oils brings the image acquisition system into being. The ISO 4406:1999 standard is a guide to establish the counting and evaluation processes of particles. The system applied to the acquisition and analysis of the data consists of a digital camera, a monocular microscope and an oil filtering system. A computational program was developed with the application of Visual Microsoft C++ in a way to detain the oil sample image from the microscope slide to the computer screen. Quantitative analyses of the wear debris particles bulk are exploited applying a graphical interface that was developed to render the image processing of the sample test. The implemented system has a reachable cost thus it can be applied for schooling goals and for bolstering laboratories of minor industries and medium size companies.
Resumo:
The cotton disease known as angular leaf spot, caused by Xanthomonas axonopodis pv. malvacearum (Xam) has been causing cotton losses in several producing regions around the world. Xam is transmitted by seeds, which may be infected both externally and internally. Infected seeds constitute the main long-distance dissemination mode of the pathogen. In view of this, the use of healthy seeds is a must. To accomplish that, detection methodologies for the bacteria must be developed be used in seed health analysis laboratories. This study aimed to develop a semi-selective medium for Xam detection in cotton seeds. The semi-selective culture medium was named MSSXAN and it was consisted of peptone (5.0 g), beef extract (3 g), sucrose (5 g), soluble starch (10 g), agar (15 g), CaCl 2 (0.25 g), Tween 80 (10 mL), distilled water (1,000 mL), crystal violet solution at 1% (150 μL), cephalexin (50 mg 1*), methyl thyophanate (10 mg*) and chlorothalonil (10 mg*) - *added after culture medium autoclaving. This MSSXAN medium shows low repressiveness to Xam and it be used for isolation of this bacteria in cotton seeds health analysis. © 2009 Academic Journals Inc.
Resumo:
Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.
Resumo:
Due to the wide diversity of unknown organisms in the environment, 99% of them cannot be grown in traditional culture medium in laboratories. Therefore, metagenomics projects are proposed to study microbial communities present in the environment, from molecular techniques, especially the sequencing. Thereby, for the coming years it is expected an accumulation of sequences produced by these projects. Thus, the sequences produced by genomics and metagenomics projects present several challenges for the treatment, storing and analysis such as: the search for clones containing genes of interest. This work presents the OCI Metagenomics, which allows defines and manages dynamically the rules of clone selection in metagenomic libraries, thought an algebraic approach based on process algebra. Furthermore, a web interface was developed to allow researchers to easily create and execute their own rules to select clones in genomic sequence database. This software has been tested in metagenomic cosmid library and it was able to select clones containing genes of interest. Copyright 2010 ACM.
Resumo:
Incluye Bibliografía
Resumo:
This work has evaluated the hematological and biochemical profile by the use of sodium diclofenac, meloxicam and firocoxib in Wistar rats. The rats were distributed in groups: G1 (control), G2 (diclofenac sodium: 15 mg/kg), G3 (meloxicam: 2.0 mg/ kg), G4 (meloxicam: 10.0 mg/ kg), G5 (firocoxib: 5.0 mg/ kg) e G6 (firocoxib: 25.0 mg/ kg). The drugs were administered intragastrically (gavage) once a day, during five days and evaluated in three moments: M1 (48 hours after the beginning of the treatment), M2 (96 hours after the beginning of the treatment) and M3 (72 hours after the ending of the treatment). In each moment of each group, five to seven animals were evaluated and laboratory exams were performed. There were no significant changes observed in the biochemical and hematological parameters by the use of meloxicam and firocoxib. One of the effects of the sodium diclofenac was eritrogram variation as hematocrit, erythrocytes, hemoglobin decrease during the treatment. In addition, the platelets and total white blood cells counts did not change except for basophil. There was no changes in AST, ALP, GGT, urea, creatinine, sodium, potassium values. However, the values of protein, globulin and albumin decreased. It was concluded that diclofenac sodium does not provide large variations in the hemogram and biochemical profile than the meloxicam and firocoxib do not provide delletery effects in laboratories tests.
Resumo:
In 2010 QIAGEN® launched to eight kits of different combinations of STRs, including the Investigator IDplex Kit. This kit allows amplification in one PCR 16 markers. The aim of this study was to evaluate the reproducibility of Investigator IDplex Kit among Latin America laboratories. In the framework of the 'III International Theoretical-Practice Course in Populations Genetic and Biologicals Filiations' in Medellín-Colombia, all participants were invited to evaluate the reproducibility of this kit, they were provided of the necessary materials for the study. The results reported by participating were tabulated for the study the reproducibility. Results and comments were received on the agreed date of 12 of the 22 laboratories registered, one participant submits comments only. Some laboratories reported greater sensitivity Investigator IDplex Kit compared with other kits containing similar markers, also highlight the easy adaptability to existing conditions in laboratories, without involving major changes to its implementation. This paper shows the high reproducibility of Investigator IDplex Kit, a new tool offered by QIAGEN® for all laboratories that perform human identification testing and biological relationship testing using DNA markers. © 2011 Elsevier B.V.
Resumo:
Latin-American Society of Forensic Genetics (SLAGF) Interlaboratory Quality Control Exercise (2010-2011) included the analysis of three bloodstain samples in FTA Classic Card (three persons, biologically unrelated) and one theoretical exercise. There were 56 participating laboratories from 13 Latin-American countries that belong to society, were reported 70 STRs, including autosomal and sex chromosome markers with consensus in 53 STRs with a rate in reporting errors of 2.3%. Fifty-six laboratories reported results in theoretical exercise with mistakes in calculation of IP for each marker. It is necessary to hold meetings to discuss the results of this exercise to reach conclusions and recommendations on all aspects of DNA forensics analysis and paternity test, to improve results and quality in the results of each laboratory. © 2011 Elsevier B.V.
Resumo:
This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.
Resumo:
A body of knowledge in Software Engineering requires experiments replications. The knowledge generated by a study is registered in the so-called lab package, which, must be reviewed by an eventual research group with the intention to replicate it. However, researchers face difficulties reviewing the lab package, what leads to problems in share knowledge among research groups. Besides that, the lack of standardization is an obstacle to the integration of the knowledge from an isolated study in a common body of knowledge. In this sense, ontologies can be applied, since they can be seen as a standard that promotes the shared understanding of the experiment information structure. In this paper, we present a workflow to generate lab packages based on EXPEiiQntology, an ontology of controlled experiments domain. In addition, by means of lab packages instantiation, it is possible to evolve the ontology, in order to deal with new concepts that may appear in different lab packages. The iterative ontology evolution aims at achieve a standard that is able to accommodate different lab packages and, hence, facilitate to review and understand their content.
Resumo:
Feline immunodeficiency virus and feline leukemia represent important infectious diseases caused by retroviruses. This study aimed to investigate the prevalence of infection by feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) in cats from the municipality of Araçatuba, São Paulo. Blood samples from 302 cats were collected and tested for the presence of antibodies against feline immunodeficiency virus and antigen of feline leukemia virus by ELISA ® Snap- Combo FIV-FeLV (IDEXX Laboratories). The frequency of FIV positivity was 5.63% (17/302) and of FeLV was 0.33% (1/302). Of the 17 cats infected with FIV, nine (52.94%) were symptomatic. There was a prevalence of FIV infection in males (p 0.0316) and cats aged between one and three years (p 0.0324).
Resumo:
Despite the fact that the processes of embryo development and implantation of mammals do not occur in atmospheric tension in vivo, it is common practice in laboratories for in vitro fertilization (IVF) the culture of embryos in an oxygen tension of 20%. The discrepancy between the tensions of oxygen leads to important discussions about their effects in vitro embryo development. It is believed that the culture of embryo in atmospheric oxygen tension can be detrimental to the quality of the data for predisposing them to the negative interference of reactive oxygen species (ROS), resulting in oxidative stress, leading to deleterious effects on metabolism embryo gene expression and blastocysts grown in those conditions. Faced with arguments for and against the culture of embryos in vitro oxygen tensions similar to those found in vivo, this revies article aims to condense and discuss the literature concerning the influence of oxygen tension on the quality of in vitro culture.
Resumo:
In this paper, remote laboratory experiment access is considered through the use of radio frequency identification (RFID) technology. Contactless smart cards are used widely in many applications from travel cards through to building access control and inventory tracking. However, their use is considered here for access to electronic engineering experimentation in a remote laboratory setting by providing the ability to interface experiments through this contactless (wireless) connection means. A case study design is implemented to demonstrate such a means by incorporating experiment data onto a contactless smart card and accessing this via a card reader and web server arrangement. © 2012 IEEE.
Resumo:
Voltammetric analysis of amodiaquine using a hemin biosensor revealed a well-defined peak at 0.14 V (vs. Ag/AgCl), corresponding to the oxidation of amodiaquine at pH 7.0. The electrodic behavior indicated that the oxidation process was irreversible, and that it was controlled by diffusion. In addition to advantages such as high selectivity and sensitivity, the method developed could be used for the analysis of breast milk containing amodiaquine without any need for prior sample treatment, an important consideration in routine analysis laboratories. Measurements of the drug contained in breast milk were used to validate the technique. The detection limit for standard solutions was 3.30 mg L-1, and the quantification limit was 11.0 mg L-1. ©The Electrochemical Society.
Resumo:
This article presents an analysis of the quality of advertisements for over-the-counter (OTC) drugs addressed to the medical profession, based on the new Anvisa resolution RDC 96 (17/12/2008). For this analysis, 16 volumes of the Brazilian Journal of Medicine (RBM) were collected, from August 2009 to December 2010. To investigate the quality of the adverts, we prepared a questionnaire divided into three parts. In total, 160 advertisements were found, of which 27 were related to drugs exempt from prescription, from 9 laboratories. It was observed that none of the advertisements complied fully with the new rules, as required by legislation (RDC 96/08), with violations ranging from identification of the advert to prohibitions of human figures and subjective messages. Therefore, it was concluded that there is a need to implement more effective monitoring, so as to improve the quality of the adverts, so they can be used as a reliable source of information and update by prescribers.