909 resultados para Polymeric lightweight concrete
Resumo:
Therapeutic RNAs, especially siRNAs, are a promising approach for treating diseases like cancer, neurodegenerative disorders and viral infections. Their application, however, is limited due to a lack of safe and efficient delivery systems. Nanosized carriers with the ability to either complex or entrap RNA species are a promising option. rn rn rnSuch a carrier has to meet a lot of requirements, some of which are even partly contradictive. Understanding and controlling the interplay between the different demands would advance a strategic design at an early stage of therapeutic development. rn rn This work is centered around a systematic evaluation of polyplexes, such carriers that are able to complex siRNA due to electrostatic interactions. Six structurally and chemically diverse candidates, poly-L-lysine brushes, block copolymers, cationic peptides, cationic lipids, nanohydrogels, and manganese oxide particles, were tested in a simultaneous fashion. The assays, mostly based on fluorescently labeled siRNA, ranged from the evaluation of polyplex formation and stability to in vitro parameters like cellular uptake and knockdown capability. The analysis from several perspectives offered insight into the interplay between the specifications of one polyplex. Assessing the different carriers under exactly the same experimental conditions also allowed conclusions about favourable traits and starting points for further optimization. This comparative approach also revealed weaknesses of some of the conventional protocols, which were therefore contrasted with alternative methods. In addition, in vitro knockdown assays were optimized and the impact of fluorescently labeled siRNA on knockdown efficiency was assessed. rn rn rn A second class of carriers, which share the ability to entrap siRNA inside their matrix, are briefly addressed. Nanocapsules, dextran particles and liposomes were assessed for basic features like siRNA encapsulation and knockdown capability. rn rn rn rn In an approach towards targeted delivery of RNA, liposomes were endowed with mitochondriotropic tags. Despite successful functionalization, no colocalization between the liposomal cargo and mitochondria was so far observed, which makes further optimization necessary.
Resumo:
This thesis focuses on the interactions of nanoparticles with artificial membranes. The synthesis of the block copolymer poly(dimethylsiloxane)-block-poly(2-methyloxazoline) (PDMS-b-PMOXA) is described, as well as the formation of polymersomes in water. These polymersomes act as minimal cell models, consisting of an artificial bilayer membrane only, allowing the study of the interactions between nanoparticles and polymeric membranes. Both spherical and rod-shaped gold nanoparticles (AuNPs) were used in this study and they were characterized using light scattering (PCS), transmission electron microscopy (TEM), UV/Vis spectroscopy, and polarization anisotropy measurements. The polymer grafting on the spherical cores is asymmetric (shell asphericity) but is parallel to the inherent, due to polycrystallinity, core anisotropy, resulting in a characteristic scattering of the AuNPs in PCS.rnInteractions of polymersomes and AuNPs were investigated by PCS, cryo-TEM and UV/Vis. Three possible scenarios upon mixing of polymersomes and AuNPs can be distinguished by using only PCS: (i) no interactions between particles and vesicles, (ii) attachment of the particles to the outer side of the vesicles (decoration), and (iii) uptake of particles into the vesicles. It is shown that all three scenarios are possible, solely depending on the particle’s surface functionalization. In addition, it was revealed that the AuNPs need to be attached to the inner side of the membrane instead of diffusing freely within the vesicle. The present experimental findings essentially help with the understanding of the interactions of nanoparticles with membranes and show that the process of endocytosis can be attributed to physical processes only. rn
Resumo:
Polymerbasierte Kolloide mit Groen im Nanometerbereich werden als aussichts- reiche Kandidaten fur die Verkapselung und den Transport von pharmazeutischen Wirkstoen angesehen. Daher ist es wichtig die physikalischen Prozesse, die die Bil- dung, Struktur und kinetische Stabilitat der polymerbasierten Kolloide beein ussen, besser zu verstehen. Allerdings ist die Untersuchung dieser Prozesse fur nanome- tergroe Objekte kompliziert und erfordert fortgeschrittene Techniken. In dieser Arbeit beschreibe ich Untersuchungen, bei denen Zwei-Farben-Fluoreszenzkreuz- korrelationsspektroskopie (DC FCCS) genutzt wurde, um Informationen uber die Wechselwirkung und den Austausch von dispergierten, nanometergroen Kolloiden zu bekommen. Zunachst habe ich den Prozess der Polymernanopartikelherstellung aus Emul- sionstropfen untersucht, welcher einen der am haugsten angewendeten Prozesse der Nanopartikelformulierung darstellt. Ich konnte zeigen, dass mit DC FCCS eindeutig und direkt Koaleszenz zwischen Emulsionstropfen gemessen werden kann. Dies ist von Interesse, da Koaleszenz als Hauptgrund fur die breite Groenverteilung der nalen Nanopartikel angesehen wird. Weiterhin habe ich den Austausch von Mizellen bildenden Molekulen zwischen amphiphilen Diblock Kopolymermizellen untersucht. Als Modellsystem diente ein Linear-Burste Block Kopolymer, welches Mizellen mit einer dichten und kurzen Korona bildet. Mit Hilfe von DC FCCS konnte der Austausch in verschiedenen Losungsmitteln und bei verschiedenen Temperaturen beobachtet werden. Ich habe herausgefunden, dass in Abhangigkeit der Qualitat des Losungsmittels die Zeit des Austausches um Groenordnungen verschoben werden kann, was eine weitreichende Einstellung der Austauschkinetik ermoglicht. Eine Eigenschaft die all diese Kolloide gemeinsam haben ist ihre Polydispersitat. Im letzten Teil meiner Arbeit habe ich am Beispiel von Polymeren als Modellsystem untersucht, welchen Eekt Polydispersitat und die Art der Fluoreszenzmarkierung auf FCS Experimente haben. Eine Anpassung des klassischen FCS Modells kann die FCS Korrelationskurven dieser Systeme beschreiben. Die Richtigkeit meines Ansatzes habe ich mit dem Vergleich zur Gel-Permeations-Chromatographie und Brownschen Molekulardynamiksimulationen bestatigt.
Resumo:
Il collasso di diverse colonne, caratterizzate da danneggiamenti simili, quali ampie fessure fortemente inclinate ad entrambe le estremità dell’elemento, lo schiacciamento del calcestruzzo e l’instabilità dei ferri longitudinali, ha portato ad interrogarsi riguardo gli effetti dell’interazione tra lo sforzo normale, il taglio ed il momento flettente. Lo studio è iniziato con una ricerca bibliografica che ha evidenziato una sostanziale carenza nella trattazione dell’argomento. Il problema è stato approcciato attraverso una ricerca di formule della scienza delle costruzioni, allo scopo di mettere in relazione lo sforzo assiale, il taglio ed il momento; la ricerca si è principalmente concentrata sulla teoria di Mohr. In un primo momento è stata considerata l’interazione tra solo due componenti di sollecitazione: sforzo assiale e taglio. L’analisi ha condotto alla costruzione di un dominio elastico di taglio e sforzo assiale che, confrontato con il dominio della Modified Compression Field Theory, trovata tramite ricerca bibliografica, ha permesso di concludere che i risultati sono assolutamente paragonabili. L’analisi si è poi orientata verso l’interazione tra sforzo assiale, taglio e momento flettente. Imponendo due criteri di rottura, il raggiungimento della resistenza a trazione ed a compressione del calcestruzzo, inserendo le componenti di sollecitazione tramite le formule di Navier e Jourawsky, sono state definite due formule che mettono in relazione le tre azioni e che, implementate nel software Matlab, hanno permesso la costruzione di un dominio tridimensionale. In questo caso non è stato possibile confrontare i risultati, non avendo la ricerca bibliografica mostrato niente di paragonabile. Lo studio si è poi concentrato sullo sviluppo di una procedura che tenta di analizzare il comportamento di una sezione sottoposta a sforzo normale, taglio e momento: è stato sviluppato un modello a fibre della sezione nel tentativo di condurre un calcolo non lineare, corrispondente ad una sequenza di analisi lineari. La procedura è stata applicata a casi reali di crollo, confermando l’avvenimento dei collassi.
Resumo:
This thesis investigates the synthesis of polymeric ionic liquid [(poly-acryloyloxy)6C6C1im][NTf2], by free radical polymerization of acryloyl imidazolium-base ionic liquid monomer [(acryloyloxy)6C6C1im][NTf2]. Moreover, the smartest synthetic route to obtain this monomer was investigated. Two different synthesis were compared. The first one started from the preparation of the monomer 6-chlorohexyl acrylate followed by substitution and metathesis to reach ionic liquid monomer. The second one started from synthesis of the ionic liquid [(HO)6C6C1im]Cl followed by metathesis and esterification in order to get ionic liquid monomer [(acryloyloxy)6C6C1im][NTf2].
Resumo:
The purpose of this work is to find a methodology in order to make possible the recycling of fines (0 - 4 mm) in the Construction and Demolition Waste (CDW) process. At the moment this fraction is a not desired by-product: it has high contaminant content, it has to be separated from the coarse fraction, because of its high water absorption which can affect the properties of the concrete. In fact, in some countries the use of fines recycled aggregates is highly restricted or even banned. This work is placed inside the European project C2CA (from Concrete to Cement and Clean Aggregates) and it has been held in the Faculty of Civil Engineering and Geosciences of the Technical University of Delft, in particular, in the laboratory of Resources And Recycling. This research proposes some procedures in order to close the loop of the entire recycling process. After the classification done by ADR (Advanced Dry Recovery) the two fractions "airknife" and "rotor" (that together constitute the fraction 0 - 4 mm) are inserted in a new machine that works at high temperatures. The temperatures analysed in this research are 600 °C and 750 °C, cause at that temperature it is supposed that the cement bounds become very weak. The final goal is "to clean" the coarse fraction (0,250 - 4 mm) from the cement still attached to the sand and try to concentrate the cement paste in the fraction 0 - 0,250 mm. This new set-up is able to dry the material in very few seconds, divide it into two fractions (the coarse one and the fine one) thanks to the air and increase the amount of fines (0 - 0,250 mm) promoting the attrition between the particles through a vibration device. The coarse fraction is then processed in a ball mill in order to improve the result and reach the final goal. Thanks to the high temperature it is possible to markedly reduce the milling time. The sand 0 - 2 mm, after being heated and milled is used to replace 100% of norm sand in mortar production. The results are very promising: the mortar made with recycled sand reaches an early strength, in fact the increment with respect to the mortar made with norm sand is 20% after three days and 7% after seven days. With this research it has been demonstrated that once the temperature is increased it is possible to obtain a clean coarse fraction (0,250 - 4 mm), free from cement paste that is concentrated in the fine fraction 0 - 0,250 mm. The milling time and the drying time can be largely reduced. The recycled sand shows better performance in terms of mechanical properties with respect to the natural one.
Resumo:
The work done is about the seismic analysis of an existing reinforced concrete structure that is equipped with a special bracing device. The main objective of the research is to provide a simple procedure that can be followed in order to design the lateral bracing system in such a way that the actual behavior of the structure matches the desired pre-defined objective curve. a great attention is devoted to the internal actions in the structural elements produced by the braces. The device used is called: Crescent shaped braces. This device is a special type of bracing because it has a banana-like geometry that allows the designer to have more control over the stiffness of the structure, especially under cyclic behavior, Unlike the conventional bracing that resists only through its axial stiffness. This device has been installed in a hospital in Italy. However, it has not been exposed to any ground motion so far. Different analysis methods, such as static pushover and dynamic time-history have been used in the analysis of the structure.
Resumo:
We investigated the inflammatory response to, and the osteoinductive efficacies of, four polymers (collagen, Ethisorb, PLGA and Polyactive) that bore either an adsorbed (fast-release kinetics) or a calcium-phosphate-coating-incorporated (slow-release kinetics) depot of BMP-2. Titanium-plate-supported discs of each polymer (n = 6 per group) were implanted at an ectopic (subcutaneous) ossification site in rats (n = 48). Five weeks later, they were retrieved for a histomorphometric analysis of the volumes of ectopic bone and foreign-body giant cells (a gauge of inflammatory reactivity), and the degree of polymer degradation. For each polymer, the osteoinductive efficacy of BMP-2 was higher when it was incorporated into a coating than when it was directly adsorbed onto the material. This mode of BMP-2 carriage was consistently associated with an attenuation of the inflammatory response. For coated materials, the volume density of foreign-body giant cells was inversely correlated with the volume density of bone (r(2) = 0.96), and the volume density of bone was directly proportional to the surface-area density of the polymer (r(2) = 0.97). Following coating degradation, other competitive factors, such as the biocompatibility and the biodegradability of the polymer itself, came into play.
Core networks for visual-concrete and abstract thought content: a brain electric microstate analysis
Resumo:
Commonality of activation of spontaneously forming and stimulus-induced mental representations is an often made but rarely tested assumption in neuroscience. In a conjunction analysis of two earlier studies, brain electric activity during visual-concrete and abstract thoughts was studied. The conditions were: in study 1, spontaneous stimulus-independent thinking (post-hoc, visual imagery or abstract thought were identified); in study 2, reading of single nouns ranking high or low on a visual imagery scale. In both studies, subjects' tasks were similar: when prompted, they had to recall the last thought (study 1) or the last word (study 2). In both studies, subjects had no instruction to classify or to visually imagine their thoughts, and accordingly were not aware of the studies' aim. Brain electric data were analyzed into functional topographic brain images (using LORETA) of the last microstate before the prompt (study 1) and of the word-type discriminating event-related microstate after word onset (study 2). Conjunction analysis across the two studies yielded commonality of activation of core networks for abstract thought content in left anterior superior regions, and for visual-concrete thought content in right temporal-posterior inferior regions. The results suggest that two different core networks are automatedly activated when abstract or visual-concrete information, respectively, enters working memory, without a subject task or instruction about the two classes of information, and regardless of internal or external origin, and of input modality. These core machineries of working memory thus are invariant to source or modality of input when treating the two types of information.
Resumo:
Rock-pocket and honeycomb defects impair overall stiffness, accelerate aging, reduce service life, and cause structural problems in hardened concrete members. Traditional methods for detecting such deficient volumes involve visual observations or localized nondestructive methods, which are labor-intensive, time-consuming, highly sensitive to test conditions, and require knowledge of and accessibility to defect locations. The authors propose a vibration response-based nondestructive technique that combines experimental and numerical methodologies for use in identifying the location and severity of internal defects of concrete members. The experimental component entails collecting mode shape curvatures from laboratory beam specimens with size-controlled rock pocket and honeycomb defects, and the numerical component entails simulating beam vibration response through a finite element (FE) model parameterized with three defect-identifying variables indicating location (x, coordinate along the beam length) and severity of damage (alpha, stiffness reduction and beta, mass reduction). Defects are detected by comparing the FE model predictions to experimental measurements and inferring the low number of defect-identifying variables. This method is particularly well-suited for rapid and cost-effective quality assurance for precast concrete members and for inspecting concrete members with simple geometric forms.
Resumo:
Different synthetic routes have been used for the preparation of a new tetranuclear [Fe4O2(O2CCMe3)(8)(bpm)] cluster (1) and a one-dimensional coordination polymer [Fe4O2-(O2CCMe3)(8)(hmta)](n) (2) (bpm = 2,2'-bipyrimidine and hmta = hexamethylenetetramine). For cluster 1, two structural isomers, 1a and 1b center dot 3MeCN, have been found. X-ray crystallographic analysis showed that all complexes consist of a central {Fe-4(mu(3)-O)(2)}(8+) core. In 1a, metal ions in the core are additionally linked by six bridging pivalates as two other pivalates and a bpm ligand are chelated to Fe-III ions, whereas in cluster 1b, metal ions in the {Fe-4(mu(3)-O)(2)}(8+) core are linked by seven bridging pivalates and only one carboxylate as well as bpm are chelated to the iron centers. In coordination polymer 2, [Fe4O2(O2CCMe3)(8)] clusters are bridged by hmta ligands to form zigzag chains. Magnetic measurements have been carried out to characterize these complexes and revealed antiferromagnetic interactions between Fe-III ions with best-fit parameters of J(wb) = -72.2 (1a) and -88.7 cm(-1) (1b) for wing...body interactions.
Resumo:
Metakaolin and volcanic ashes respectively called MK and ZG were used as aluminosilicate raw materials for the synthesis of porous geopolymers. The hydrogen peroxide was used as a blowing agent. The geopolymer prepared were characterized by Spectroscopy Fourier Transform Infrared (SFTI), X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM) and the determination of some physical properties such as bulk density, total porosity, volume shrinkage, compressive strength and thermal conductivity was also carried out. The presence of pores in the geopolymer obtained is function of the percentage of hydrogen peroxide added, causing the concomitantly decrease in compressive strength, apparent density and thermal conductivity. The use of hydrogen peroxide as a blowing agent gave some thermal insulation properties to these geopolymers which could be close to the properties of some commercial insulation materials.
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.
Resumo:
BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.