887 resultados para Peripheral fatigue
Resumo:
This thesis work encloses activities carried out in the Laser Center of the Polytechnic University of Madrid and the laboratories of the University of Bologna in Forlì. This thesis focuses on the superficial mechanical treatment for metallic materials called Laser Shock Peening (LSP). This process is a surface enhancement treatment which induces a significant layer of beneficial compressive residual stresses underneath the surface of metal components in order to improve the detrimental effects of the crack growth behavior rate in it. The innovation aspect of this work is the LSP application to specimens with extremely low thickness. In particular, after a bibliographic study and comparison with the main treatments used for the same purposes, this work analyzes the physics of the operation of a laser, its interaction with the surface of the material and the generation of the surface residual stresses which are fundamentals to obtain the LSP benefits. In particular this thesis work regards the application of this treatment to some Al2024-T351 specimens with low thickness. Among the improvements that can be obtained performing this operation, the most important in the aeronautic field is the fatigue life improvement of the treated components. As demonstrated in this work, a well-done LSP treatment can slow down the progress of the defects in the material that could lead to sudden failure of the structure. A part of this thesis is the simulation of this phenomenon using the program AFGROW, with which have been analyzed different geometric configurations of the treatment, verifying which was better for large panels of typical aeronautical interest. The core of the LSP process are the residual stresses that are induced on the material by the interaction with the laser light, these can be simulated with the finite elements but it is essential to verify and measure them experimentally. In the thesis are introduced the main methods for the detection of those stresses, they can be mechanical or by diffraction. In particular, will be described the principles and the detailed realization method of the Hole Drilling measure and an introduction of the X-ray Diffraction; then will be presented the results I obtained with both techniques. In addition to these two measurement techniques will also be introduced Neutron Diffraction method. The last part refers to the experimental tests of the fatigue life of the specimens, with a detailed description of the apparatus and the procedure used from the initial specimen preparation to the fatigue test with the press. Then the obtained results are exposed and discussed.
Resumo:
Lo scopo di questa tesi è lo studio degli aspetti procedurali e dosimetrici in angiografie periferiche che utilizzano la CO2 come mezzo di contrasto. La tecnica angiografica consiste nell’imaging radiologico di vasi sanguigni tramite l’iniezione di un mezzo di contrasto, e il suo uso è in costante incremento a causa dell’aumento di pazienti con malattie vascolari. I mezzi di contrasto iodati sono i più comunemente utilizzati e permettono di ottenere immagini di ottima qualità, ma presentano il limite di una elevata nefrotossicità. La CO2 è considerata un’interessante alternativa al mezzo iodato, per la sua acclarata biocompatibilità, soprattutto per pazienti con elevati fattori di rischio (diabete e/o insufficienza renale). Il suo utilizzo presenta comunque alcuni aspetti problematici, dovuti allo stato gassoso e al basso contrasto intrinseco rispetto alla soluzione iodata. Per quest’ultimo motivo si ritiene generalmente che l’utilizzo della CO2 comporti un aumento di dose rispetto ai mezzi di contrasto tradizionali. Il nostro studio, effettuato su diversi apparati radiologici, ha dimostrato che i parametri di emissione radiologica sono gli stessi per i protocolli di angiografia tradizionale, con iodio, e quelli che utilizzano CO2. Questa evidenza suggerisce che i protocolli CO2 operino solo sul trattamento delle immagini ottenute e non sulla modalità di acquisizione, e dal punto di vista dosimetrico l’angiografia con CO2 è riconducibile all’angiografia tradizionale. L’unico fattore che potrebbe portare a un effettivo incremento di dose al paziente è un allungamento dei tempi di scopia e di procedura, che andrebbe verificato con una campagna di misure in ambito clinico. Sulla base della stessa evidenza, si ritiene che la visualizzazione della CO2 possa essere ulteriormente migliorata attraverso l’ottimizzazione dei parametri di emissione radiologica (kVp, frame rate e durata degli impulsi) attualmente predisposti per l’uso di mezzi di contrasto iodati.