976 resultados para Orthodontic mini-implants
Resumo:
The use of smaller surgical incisions has become popularized for total hip arthroplasty (THR) because of the potential benefits of shorter recovery and improved cosmetic appearance. However, an increased incidence of serious complications has been reported. To minimize the risks of minimally invasive approaches to THR, we have developed an experimental approach which enables us to evaluate risk factors in these procedures through cadaveric simulations performed within the laboratory. During cadaveric hip replacement procedures performed via posterior and antero-lateral mini-incisions, pressures developed between the wound edges and the retractors were approximately double those recorded during conventional hip replacement using Charnley retractors (p < 0.01). In MIS procedures performed via the dual-incision approach, lack of direct visualisation of the proximal femur led to misalignment of broaches and implants with increased risk of cortical fracture during canal preparation and implant insertion. Cadaveric simulation of surgical procedures allows surgeons to measure variables affecting the technical success of surgery and to master new procedures without placing patients at risk.
Resumo:
Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.
Resumo:
High-performance thermoplastics including polyetheretherketone (PEEK) are key biomaterials for load-bearing implants. Plasma treatment of implants surfaces has been shown to chemically activate its surface, which is a prerequisite to achieve proper cell attachment. Oxygen plasma treatment of PEEK films results in very reproducible surface nanostructures and has been reported in the literature. Our goal is to apply the plasma treatment to another promising polymer, polyetherketoneketone (PEKK), and compare its characteristics to the ones of PEEK. Oxygen plasma treatments of plasma powers between 25 and 150 W were applied on 60 μm-thick PEKK and 100 μm-thick PEEK films. Analysis of the nanostructures by atomic force microscopy showed that the roughness increased and island density decreased with plasma power for both PEKK and PEEK films correlating with contact angle values without affecting bulk properties of the used films. Thermal analysis of the plasma-treated films shows that the plasma treatment does not change the bulk properties of the PEKK and PEEK films.
Resumo:
The purpose of the internet-based teachware mySCM is that students of economics, informatics and industrial engineering get familiar with quantitative methods for supply chain management. Input-output-relationships of various optimization methods can be detected by sampling input values, parameters, and alternative methods for the same problem. Students can gain extra benefits by passing so-called mini-exams that motivate active learning. mySCM can be used for free, round-the-clock, and any place where access to the Internet is available.
Resumo:
BACKGROUND: Zirconia (ZrO2 ) has received interest as a dental material; however, little information is available on the impact of surface modifications on the osseointegration of zirconia implants. PURPOSE: The aim of the present study was to determine the effect of acid or alkaline etching of sandblasted ZrO2 implants on bone apposition in vivo. METHODS: Cylindrical ZrO2 implants with two circumferential grooves were placed in the maxilla of 12 miniature pigs. Biopsies were harvested after 1, 2, 4, and 8 weeks of healing. Undecalcified toluidine blue-stained ground sections were produced. The bone-to-implant contact, the bone area, and the presence of multinucleated giant cells were determined by histomorphometry. An uncorrected explorative statistical analysis was performed. RESULTS: Acid etching but not alkaline etching of sandblasted ZrO2 implants caused more bone-to-implant contact than sandblasted ZrO2 implants. The bone area was unaffected by the surface modifications. Acid and alkaline etching both increased the formation of multinucleated giant cells at the implant surface. CONCLUSIONS: This study provides a scientific basis to further investigate the impact of acid etching of sandblasted ZrO2 implants on osseointegration and the role of multinucleated giant cells in this process.
Resumo:
UPF1, an RNA helicase and a core factor of nonsense-mediated mRNA decay (NMD), interacts with RNA independently of the sequence context. To investigate the influence of translation on the association of UPF1 with specific reporter transcripts, UPF1 RNA immunoprecipitations (RIPs) are performed from Hela cells that either express a normally translated immunoglobulin-µ (Ig-µ) reporter (mini µ) or a version with a stable stem loop in the 5' UTR (SL mini µ) that efficiently inhibit translation initiation (Zund et al., 2013). Both the cloning of the SL mini µ reporter construct and the UPF1 RIP experiment are described in detail.
Resumo:
The purpose of this long-term follow-up study was twofold-firstly, to assess prevalence of relapse after treatment of deep bite malocclusion and secondly, to identify risk factors that predispose patients with deep bite malocclusion to relapse. Sixty-one former patients with overbite more than 50% incisor overlap before treatment were successfully recalled. Clinical data, morphometrical measurements on plaster casts before treatment, after treatment and at long-term follow-up, as well as cephalometric measurements before and after treatment were collected. The median follow-up period was 11.9 years. Patients were treated by various treatment modalities, and the majority of patients received at least a lower fixed retainer and an upper removable bite plate during retention. Relapse was defined as increase in incisor overlap from below 50% after treatment to equal or more than 50% incisor overlap at long-term follow-up. Ten per cent of the patients showed relapse to equal or larger than 50% incisor overlap, and their amount of overbite increase was low. Among all cases with deep bite at follow-up, gingival contact and palatal impingement were more prevalent in partially corrected noncompliant cases than in relapse cases. In this sample, prevalence and amount of relapse were too low to identify risk factors of relapse.
Resumo:
OBJECTIVE To survey retention procedures used in orthodontic practices in Switzerland. MATERIAL AND METHODS A questionnaire previously developed by Renkema et al. (2009) was sent to 223 Swiss orthodontists. The questionnaire comprised six parts, mainly containing multiple-choice questions. Information as to background education of the individual orthodontist, retention in general, frequency of different types of removable or bonded retainers that were used, retention pro- tocol, and the type and size of the wire used for bonded retainers was assessed. RESULTS The overall response rate was 65 percent. Most orthodontists placed a bonded retainer in the upper and lower arch, except when the upper arch was expanded during treatment or when extractions were performed in the upper arch, in which case they placed a combination of fixed and removable retainers. Opinions varied with regard to how many hours the removable retainers should be worn and the duration of the retention phase. As far as bonded retainers were concerned, 87 percent of the orthodontists preferred life-long retention. Ninety-three percent of the orthodontists considered that the development of a guide- line on retention procedures would be useful. CONCLUSIONS The choice of retention procedures is mostly based on orthodontists personal preference. A further research into the long-term effectiveness of individual retention protocols is needed.
Resumo:
OBJECTIVES To assess the available evidence on the effectiveness of accelerated orthodontic tooth movement through surgical and non-surgical approaches in orthodontic patients. METHODS Randomized controlled trials and controlled clinical trials were identified through electronic and hand searches (last update: March 2014). Orthognathic surgery, distraction osteogenesis, and pharmacological approaches were excluded. Risk of bias was assessed using the Cochrane risk of bias tool. RESULTS Eighteen trials involving 354 participants were included for qualitative and quantitative synthesis. Eight trials reported on low-intensity laser, one on photobiomodulation, one on pulsed electromagnetic fields, seven on corticotomy, and one on interseptal bone reduction. Two studies on corticotomy and two on low-intensity laser, which had low or unclear risk of bias, were mathematically combined using the random effects model. Higher canine retraction rate was evident with corticotomy during the first month of therapy (WMD=0.73; 95% CI: 0.28, 1.19, p<0.01) and with low-intensity laser (WMD=0.42mm/month; 95% CI: 0.26, 0.57, p<0.001) in a period longer than 3 months. The quality of evidence supporting the interventions is moderate for laser therapy and low for corticotomy intervention. CONCLUSIONS There is some evidence that low laser therapy and corticotomy are effective, whereas the evidence is weak for interseptal bone reduction and very weak for photobiomodulation and pulsed electromagnetic fields. Overall, the results should be interpreted with caution given the small number, quality, and heterogeneity of the included studies. Further research is required in this field with additional attention to application protocols, adverse effects, and cost-benefit analysis. CLINICAL SIGNIFICANCE From the qualitative and quantitative synthesis of the studies, it could be concluded that there is some evidence that low laser therapy and corticotomy are associated with accelerated orthodontic tooth movement, while further investigation is required before routine application.
Resumo:
OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
Resumo:
OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. RESULTS Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. CONCLUSIONS/IMPLICATIONS Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy.
Resumo:
OBJECTIVE To assess the indication and timing of soft tissue augmentation for prevention or treatment of gingival recession when a change in the inclination of the incisors is planned during orthodontic treatment. MATERIALS AND METHODS Electronic database searches of literature were performed. The following electronic databases with no restrictions were searched: MEDLINE, EMBASE, Cochrane, and CENTRAL. Two authors performed data extraction independently using data collection forms. RESULTS No randomized controlled trial was identified. Two studies of low-to-moderate level of evidence were included: one of prospective and retrospective data collection and one retrospective study. Both implemented a periodontal intervention before orthodontics. Thus, best timing of soft tissue augmentation could not be assessed. The limited available data from these studies appear to suggest that soft tissue augmentation of bucco-lingual gingival dimensions before orthodontics may yield satisfactory results with respect to the development or progression of gingival recessions. However, the strength of the available evidence is not adequate in order to change or suggest a possible treatment approach in the daily practice based on solid scientific evidence. CONCLUSIONS Despite the clinical experience that soft tissue augmentation of bucco-lingual gingival dimensions before orthodontic treatment may be a clinically viable treatment option in patients considered at risk, this treatment approach is not based on solid scientific evidence. Moreover, the present data do not allow to draw conclusions on the best timing of soft tissue augmentation when a change in the inclination of the incisors is planned during orthodontic treatment and thus, there is a stringent need for randomized controlled trials to clarify these open issues.
Resumo:
Factorial designs for clinical trials are often encountered in medical, dental, and orthodontic research. Factorial designs assess two or more interventions simultaneously and the main advantage of this design is its efficiency in terms of sample size as more than one intervention may be assessed on the same participants. However, the factorial design is efficient only under the assumption of no interaction (no effect modification) between the treatments under investigation and, therefore, this should be considered at the design stage. Conversely, the factorial study design may also be used for the purpose of detecting an interaction between two interventions if the study is powered accordingly. However, a factorial design powered to detect an interaction has no advantage in terms of the required sample size compared to a multi-arm parallel trial for assessing more than one intervention. It is the purpose of this article to highlight the methodological issues that should be considered when planning, analysing, and reporting the simplest form of this design, which is the 2 × 2 factorial design. An example from the field of orthodontics using two parameters (bracket type and wire type) on maxillary incisor torque loss will be utilized in order to explain the design requirements, the advantages and disadvantages of this design, and its application in orthodontic research.