998 resultados para Optical quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess image quality using PGMI (perfect, good, moderate, inadequate) scale in digital mammography examinations acquired in DR systems. Identify the main failures and propose corrective actions. Evaluate the most typical breast density. Methods and Materials: Clinical image quality criteria were evaluated considering mammograms acquired in 13 DR systems and classified according to PGMI scale using the criteria described in European Commission guidelines for radiographers. The breast density was assessed according to ACR recommendations. The data were collected on the acquisition system monitor to reproduce the daily practice of the radiographer. Results: The image quality criteria were evaluated in 3044 images. The criteria were fully achieved in 41% of the images that were classified as P (perfect), 31 % of the images were classified as M (moderate), 20% G (good) and 9% I (inadequate). The main cause of inadequate image quality was absence of all breast tissue in the image, skin folders in the pectoral muscle and in the infra-mammary angle. The higher number of failures occurred in MLO projections (809 out of 1022). The most represented (36%) breast type was type 2 (25-50% glandular tissue). Conclusion: Incorrect radiographic technique was frequently detected suggesting potential training needs and poor communication between the team members (radiographer and radiologists). Further correlations are necessary to identify the main causes for the failures, namely specific education and training in digital mammography and workload.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si: H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze evidence of the validity and reliability of a Brazilian Portuguese version of the Quality of Care Scale from the perspective of people with physical and intellectual disabilities.METHODS There were 162 people with physical disabilities and 156 with intellectual disabilities from Porto Alegre and metropolitan region, who participated in the study in 2008. Classical psychometrics was used to independently analyze the two samples. Hypotheses for evidence of criterion validity (concurrent type) were tested with the Mann-Whitney test for non-normal distributions. Principal components analysis was used to explore factorial models. Evidence of reliability was calculated with Cronbach alpha for the scales and subscales. Test-retest reliability was analyzed for individuals with intellectual disabilities through intra-class correlation coefficient and the Willcoxon test.RESULTS The principal components in the group with physical disabilities replicated the original model presented as a solution to the international project data. Evidence of discriminant validity and test-retest reliability was found.CONCLUSIONS The transcultural factor model found within the international sample project seems appropriate for the samples investigated in this study, especially the physical disabilities group. Depression, pain, satisfaction with life and disability may play a mediating role in the evaluation of quality of care. Additional research is needed to add to evidence of the validity of the instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the association between sleep quality and quality of life of nursing professionals according to their work schedules.METHODS A prospective, cross-sectional, observational study was conducted between January and December 2010, with 264 nursing professionals, drawn from 989 subjects at Botucatu General Hospital and stratified by professional category. The Pittsburg Sleep Quality Index and the WHOQOL-bref were administered to evaluate sleep quality and quality of life, respectively. Self-reported demographic data were collected with a standard form. Continuous variables were reported as means and standard deviations, and categorical variables were expressed as proportions. Associations were evaluated using Spearman’s correlation coefficient. The association of night-shift work and gender with sleep disturbance was evaluated by logistic regression analysis using a model adjusted for age and considering sleep disturbance the dependent variable. The level of significance was p < 0.05.RESULTS Night-shift work was associated with severe worsening of at least one component of sleep quality in the model adjusted for age (OR = 1.91; 95%CI 1.04;3.50; p = 0.036). Female gender was associated with sleep disturbance (OR = 3.40; 95%CI 1.37;8.40; p = 0.008). Quality of life and quality of sleep were closely correlated (R = -0.56; p < 0.001).CONCLUSIONS Characteristics of the nursing profession affect sleep quality and quality of life, and these two variables are associated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is the design of an optoelectronic circuit based on a-SiC technology, able to act simultaneously as a 4-bit binary encoder or a binary decoder in a 4-to-16 line configurations and show multiplexer-based logical functions. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n multilayered structure produced by PECVD. To analyze it under information-modulated wave (color channels) and uniform irradiation (background) four monochromatic pulsed lights (input channels): red, green, blue and violet shine on the device. Steady state optical bias was superimposed separately from the front and the back sides, and the generated photocurrent was measured. Results show that the devices, under appropriate optical bias, act as reconfigurable active filters that allow optical switching and optoelectronic logic functions development providing the possibility for selective removal of useless wavelengths. The logic functions needed to construct any other complex logic functions are the NOT, and both or either an AND or an OR. Any other complex logic function that might be found can also be used as building blocks to achieve the functions needed for the retrieval of channels within the WDM communication link. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the inequalities in access, utilization, and quality of health care services according to the socioeconomic status. METHODS This population-based cross-sectional study evaluated 2,927 individuals aged ≥ 20 years living in Pelotas, RS, Southern Brazil, in 2012. The associations between socioeconomic indicators and the following outcomes were evaluated: lack of access to health services, utilization of services, waiting period (in days) for assistance, and waiting time (in hours) in lines. We used Poisson regression for the crude and adjusted analyses. RESULTS The lack of access to health services was reported by 6.5% of the individuals who sought health care. The prevalence of use of health care services in the 30 days prior to the interview was 29.3%. Of these, 26.4% waited five days or more to receive care and 32.1% waited at least an hour in lines. Approximately 50.0% of the health care services were funded through the Unified Health System. The use of health care services was similar across socioeconomic groups. The lack of access to health care services and waiting time in lines were higher among individuals of lower economic status, even after adjusting for health care needs. The waiting period to receive care was higher among those with higher socioeconomic status. CONCLUSIONS Although no differences were observed in the use of health care services across socioeconomic groups, inequalities were evident in the access to and quality of these services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the job quality in Europe. It is based on the results of the Fourth European Foundation Survey on working conditions covering different dimensions including work organisation, job content, autonomy at work, aspects of worker dignity, working time and work-life balance, working conditions and safety in the workplace. The results point to the existence of great diversity in the job quality across Europe and the north-south divide. The job quality differences are related to the variety of social and institutional contexts. The countries of Southern Europe, with their social and institutional contexts falling within the scope of the Mediterranean model, generally present indicators below the European average contrasting Nordic countries having the best job quality indicators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visible range to telecom band spectral translation is accomplished using an amorphous SiC pi'n/pin wavelength selector under appropriate front and back optical light bias. Results show that background intensity works as selectors in the infrared region, shifting the sensor sensitivity. Low intensities select the near-infrared range while high intensities select the visible part according to its wavelength. Here, the optical gain is very high in the infrared/red range, decreases in the green range, stays close to one in the blue region and strongly decreases in the near-UV range. The transfer characteristics effects due to changes in steady state light intensity and wavelength backgrounds are presented. The relationship between the optical inputs and the output signal is established. A capacitive optoelectronic model is presented and tested using the experimental results. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Gestão de Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxidative behaviour of fluoxetine was studied at a glassy carbon electrode in various buffer systems and at different pH using cyclic, differential pulse and square wave voltammetry. A new square wave voltammetric method suitable for the quality control of fluoxetine in commercial formulations has been developed using a borate pH 9 buffer solution as supporting electrolyte. Under optimized conditions, a linear response was obtained in the range 10 to 16 μM with a detection limit of 1.0 μM. Validation parameters such as sensitivity, precision and accuracy were evaluated. The proposed method was successfully applied to the determination of fluoxetine in pharmaceutical formulations. The results were statistically compared with those obtained by the reference high-performance liquid chromatographic method. No significant differences were found between the methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado integrado em Engenharia do Ambiente, perfil: Gestão de Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To examine whether religiousness mediates the relationship between sociodemographic factors, multimorbidity and health-related quality of life of older adults.METHODS This population-based cross-sectional study is part of the Survey on Health, Well-Being, and Aging (SABE). The sample was composed by 911 older adults from Sao Paulo, SP, Southeastern Brazil. Structural equation modeling was performed to assess the mediator effect of religiousness on the relationship between selected variables and health-related quality of life of older adults, with models for men and women. The independent variables were: age, education, family functioning and multimorbidity. The outcome variable was health-related quality of life of older adults, measured by SF-12 (physical and mental components). The mediator variables were organizational, non-organizational and intrinsic religiousness. Cronbach’s alpha values were: physical component = 0.85; mental component = 0.80; intrinsic religiousness = 0.89 and family APGAR (Adaptability, Partnership, Growth, Affection, and Resolve) = 0.91.RESULTS Higher levels of organizational and intrinsic religiousness were associated with better physical and mental components. Higher education, better family functioning and fewer diseases contributed directly to improved performance in physical and mental components, regardless of religiousness. For women, organizational religiousness mediated the relationship between age and physical (β = 2.401, p < 0.01) and mental (β = 1.663, p < 0.01) components. For men, intrinsic religiousness mediated the relationship between education and mental component (β = 7.158, p < 0.01).CONCLUSIONS Organizational and intrinsic religiousness had a beneficial effect on the relationship between age, education and health-related quality of life of these older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desde 1935 que tem sido demonstrada a relação entre a execução de um trabalho de perto prolongado e o aparecimento de queixas visuais astenópicas. Anomalias da VB encontram-se significativamente aumentadas ao fim de um dia de trabalho com fixação de perto. Diminuição significativa da amplitude de acomodação e convergência depois de quatro dias a realizar uma atividade de perto. Objectivo geral: avaliar o estado da visão binocular dos profissionais de Anatomia Patológica utilizadores de microscópio ótico. Objectivos específicos: identificar as queixas astenópicas mais frequentes dos profissionais durante o trabalho com o microscópio ótico; comparar o estado da VB no início e no final de uma semana de trabalho; correlacionar o estado da VB com as queixas astenópicas sentidas pelos profissionais; correlacionar as queixas astenópicas com as horas e o número de anos de trabalho com o microscópio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An integration of undoped InOx and commercial ITO thin films into laboratory assembled light shutter devices is made. Accordingly, undoped transparent conductive InOx thin films, about 100 nm thick, are deposited by radiofrequency plasma enhanced reactive thermal evaporation (rf-PERTE) of indium teardrops with no intentional heating of the glass substrates. The process of deposition occurs at very low deposition rates (0.1-0.3 nm/s) to establish an optimized reaction between the oxygen plasma and the metal vapor. These films show the following main characteristics: transparency of 87% (wavelength, lambda = 632.8 nm) and sheet resistance of 52 Omega/sq; while on commercial ITO films the transparency was of 92% and sheet resistance of 83 Omega/sq. The InOx thin film surface characterized by AFM shows a uniform grain texture with a root mean square surface roughness of Rq similar to 2.276 nm. In contrast, commercial ITO topography is characterized by two regions: one smoother with Rq similar to 0.973 nm and one with big grains (Rq similar to 3.617 nm). For the shutters assembled using commercial ITO, the light transmission coefficient (Tr) reaches the highest value (Tr-max) of 89% and the lowest (Tr-min) of 1.3% [13], while for the InOx shutters these values are 80.1% and 3.2%, respectively. Regarding the electric field required to achieve 90% of the maximum transmission in the ON state (E-on), the one presented by the devices assembled with commercial ITO coated glasses is 2.41 V/mu m while the one presented by the devices assembled with InOx coated glasses is smaller, 1.77 V/mu m. These results corroborate the device quality that depends on the base materials and fabrication process used. (C) 2014 Elsevier Ltd. All rights reserved.