892 resultados para Occupancy Grid
Resumo:
Power system policies are broadly on track to escalate the use of renewable energy resources in electric power generation. Integration of dispersed generation to the utility network not only intensifies the benefits of renewable generation but also introduces further advantages such as power quality enhancement and freedom of power generation for the consumers. However, issues arise from the integration of distributed generators to the existing utility grid are as significant as its benefits. The issues are aggravated as the number of grid-connected distributed generators increases. Therefore, power quality demands become stricter to ensure a safe and proper advancement towards the emerging smart grid. In this regard, system protection is the area that is highly affected as the grid-connected distributed generation share in electricity generation increases. Islanding detection, amongst all protection issues, is the most important concern for a power system with high penetration of distributed sources. Islanding occurs when a portion of the distribution network which includes one or more distributed generation units and local loads is disconnected from the remaining portion of the grid. Upon formation of a power island, it remains energized due to the presence of one or more distributed sources. This thesis introduces a new islanding detection technique based on an enhanced multi-layer scheme that shows superior performance over the existing techniques. It provides improved solutions for safety and protection of power systems and distributed sources that are capable of operating in grid-connected mode. The proposed active method offers negligible non-detection zone. It is applicable to micro-grids with a number of distributed generation sources without sacrificing the dynamic response of the system. In addition, the information obtained from the proposed scheme allows for smooth transition to stand-alone operation if required. The proposed technique paves the path towards a comprehensive protection solution for future power networks. The proposed method is converter-resident and all power conversion systems that are operating based on power electronics converters can benefit from this method. The theoretical analysis is presented, and extensive simulation results confirm the validity of the analytical work.
Resumo:
Predictive models of species distributions are important tools for fisheries management. Unfortunately, these predictive models can be difficult to perform on large waterbodies where fish are difficult to detect and exhaustive sampling is not possible. In recent years the development of Geographic Information Systems (GIS) and new occupancy modelling techniques has improved our ability to predict distributions across landscapes as well as account for imperfect detection. I surveyed the nearshore fish community at 105 sites between Kingston, Ontario and Rockport, Ontario with the objective of modelling geographic and environmental characteristics associated with littoral fish distributions. Occupancy modelling was performed on Round Goby, Yellow perch, and Lepomis spp. Modelling with geographic and environmental covariates revealed the effect of shoreline exposure on nearshore habitat characteristics and the occupancy of Round Goby. Yellow Perch, and Lepomis spp. occupancy was most strongly associated negatively with distance to a wetland. These results are consistent with past research on large lake systems indicate the importance of wetlands and shoreline exposure in determining the fish community of the littoral zone. By examining 3 species with varying rates of occupancy and detection, this study was also able to demonstrate the variable utility of occupancy modelling.
Resumo:
By-catch and discards are a common problem to all fisheries. Recent studies of the Portuguese crustacean-trawl fishery show that discards average 70% of the total catch. This situation poses a threat not only to the management of target and commercial fish by-catch species stocks, but also in terms of the ecosystem impact of the discarded species whose survival is generally low. Previous attempts to address this problem by using oblique separator mesh panels associated with square-mesh windows, or square-mesh windows alone, provided encouraging results, but these are unlikely to have commercial applicability at present. Therefore, we tested the efficiency of a modified Nordmore grid in excluding some of the most captured non-commercial by-catch species, such as the blue whiting, Micromesistius poutassou, and the boarfish, Capros aper, evaluating simultaneously the losses of the crustacean target species (rose shrimp, Parapenaeus longirostris, Norway lobster, Nephrops norvegicus and red shrimp, Aristeus antennatus) and commercially valuable fish by-catch. A total of 41 valid hauls were carried out during 2001, and 15 in 2002 on board the R/V "Noruega". Results from both years varied considerably, with higher by-catch exclusion rates, in weight, registered in the second survey (73-74 and 48-63% for blue whiting and boarfish, respectively). The corresponding percentage reduction for target species was 8-15% for the Norway lobster, 4-9% for rose shrimp and 7-10% for red shrimp. The level of exclusion of the non-commercial by-catch is encouraging, although short-term loss of Norway lobster, where the escapees comprised larger individuals, raises some concern with regards to fishers' acceptance of mandatory use of grids. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This paper focuses on tests of photovoltaic systems in order to address two case studies with silicon monocrystalline and silicon polycrystalline panels, respectively. The first case is an identification of the three parameters of the single-diode equivalent circuit for modelling photovoltaic systems with conclusion about the inevitably age degradation. A comparison between experimental observed and computed I-V and V-P characteristics curves is carried out at standard test conditions. The second case is an experimental observation on a photovoltaic system connected to an electric grid in what regards the quality of the energy injected into the grid. A measuring of the harmonic content in the voltage and in the current waveforms at the terminals of the photovoltaic system is carried out in order to conclude about the conformity with the Standard EN 50160 and the IEEE 519-1992, respectively.
Resumo:
This paper focuses on technology state of the art for the charge/discharge of electric energy storage supported by vanadium redox flow battery linked to the electric grid. Properties of vanadium, the main configuration and the reaction of charge/discharge of a vanadium redox flow battery are addressed. The vanadium redox flow battery has the highest cell voltage among the other redox flow battery, implying higher power and energy density which favours application at power plants. This electric energy storage is viewed as a promising contribution to be integrated in power system due to a reasonably bulky size and to successful applications currently allowing storage of energy at power plants or at electrical grids. For instances, allowing storage of energy as an economic improvement providing spin reserve to avoid penalty for imbalances between the energy delivered and energy contracted at closing of electricity market or as an economic improvement to diminish the cost of electricity usage of a consumer. The vanadium redox flow battery has the advantages of scalability customized to meet requirements for power and energy capacity and of excellent combination of energy efficiency, capital cost and life cycle costs compared with other technology.
Resumo:
This paper is on modeling and simulation for an offshore wind system equipped with a semi-submersible floating platform, a wind turbine, a permanent magnet synchronous generator, a multiple point clamped four level or five level full-power converter, a submarine cable and a second order filter. The drive train is modeled by three mass model considering the resistant stiffness torque, structure and tower in deep water due to the moving surface elevation. The system control uses PWM by space vector modulation associated with sliding mode and proportional integral controllers. The electric energy is injected into the electric grid either by an alternated current link or by a direct current link. The model is intend to be a useful tool for unveil the behavior and performance of the offshore wind system, especially for the multiple point clamped full-power converter, under normal operation or under malfunctions.
Resumo:
Failure to detect a species at sites where it is present (i.e. imperfect detection) is known to occur frequently, but this is often disregarded in monitoring programs and metapopulation studies. Here we modelled for the first time the probability of patch occupancy by a threatened small mammal, the southern water vole (Arvicola sapidus, while accounting for the probability of detection given occupancy. Based on replicated presence sign surveys conducted in autumn (November–December 2013) and winter (February–March 2014) in a farmland landscape, we used occupancy detection modelling to test the effects of vegetation, sampling effort, observer experience, and rainfall on detection probability. We then assessed whether occupancy was related to patch size, isolation, vegetation, or presence of water, after correcting for imperfect detection. The mean detection probabilities of water vole signs in autumn (0.71) and winter (0.81) indicated that false absences may be generated in about 20–30% of occupied patches surveyed by a single observer on a single occasion. There was no statistical support for the effects of covariates on detectability. After controlling for imperfect detection, the mean probabilities of occupancy in autumn (0.31) and winter (0.29) were positively related to patch size and presence of water, and negatively so, albeit weakly, to patch isolation. Overall, our study underlined the importance of accounting for imperfect detection in sign surveys of small mammals such as water voles, pointing out the need to use occupancy detection modelling together with replicate surveys for accurately estimating occupancy and the factors affecting it.