957 resultados para Non ideal dynamic system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been argued that power-law time-to-failure fits for cumulative Benioff strain and an evolution in size-frequency statistics in the lead-up to large earthquakes are evidence that the crust behaves as a Critical Point (CP) system. If so, intermediate-term earthquake prediction is possible. However, this hypothesis has not been proven. If the crust does behave as a CP system, stress correlation lengths should grow in the lead-up to large events through the action of small to moderate ruptures and drop sharply once a large event occurs. However this evolution in stress correlation lengths cannot be observed directly. Here we show, using the lattice solid model to describe discontinuous elasto-dynamic systems subjected to shear and compression, that it is for possible correlation lengths to exhibit CP-type evolution. In the case of a granular system subjected to shear, this evolution occurs in the lead-up to the largest event and is accompanied by an increasing rate of moderate-sized events and power-law acceleration of Benioff strain release. In the case of an intact sample system subjected to compression, the evolution occurs only after a mature fracture system has developed. The results support the existence of a physical mechanism for intermediate-term earthquake forecasting and suggest this mechanism is fault-system dependent. This offers an explanation of why accelerating Benioff strain release is not observed prior to all large earthquakes. The results prove the existence of an underlying evolution in discontinuous elasto-dynamic, systems which is capable of providing a basis for forecasting catastrophic failure and earthquakes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical trials have established bosentan, an orally active non-selective endothelin (ET) receptor antagonist, as a beneficial treatment in pulmonary hypertension. Trials have also shown short-term benefits of bosentan in systemic hypertension and congestive heart failure. However, bosentan also increased plasma levels of ET-1, probably by inhibiting the clearance of ET-1 by endothelin type B (ET.) receptors, and this may mean its effectiveness is reduced with long-term clinical use. Preliminary data suggests that selective endothelin type A (ETA) receptor antagonists (BQ-123, sitaxsentan) may be more beneficial than the non-selective ET receptor antagonists in heart failure, especially when the failure is associated with pulmonary hypertension. Experimental evidence in animal disease models suggests that non-selective ET or selective ETA receptor antagonism may have a role in the treatment of athero-sclerosis, restenosis, myocarditis, shock and portal hypertension. In animal models of myocardial infarction and/or reperfusion injury, non-selective ET or selective ETA receptor antagonists have beneficial or detrimental effects depending on the conditions and agents used. Thus clinical trials of the nonselective ET or selective ETA receptor antagonists in these conditions are not presently warranted. Several selective endothelin-converting enzyme inhibitors tors have been synthesised recently, and these are only beginning to be tested in animal models of cardiovascular disease, and thus the clinical potential of these inhibitors is still to be defined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurement of exchange of substances between blood and tissue has been a long-lasting challenge to physiologists, and considerable theoretical and experimental accomplishments were achieved before the development of the positron emission tomography (PET). Today, when modeling data from modern PET scanners, little use is made of earlier microvascular research in the compartmental models, which have become the standard model by which the vast majority of dynamic PET data are analysed. However, modern PET scanners provide data with a sufficient temporal resolution and good counting statistics to allow estimation of parameters in models with more physiological realism. We explore the standard compartmental model and find that incorporation of blood flow leads to paradoxes, such as kinetic rate constants being time-dependent, and tracers being cleared from a capillary faster than they can be supplied by blood flow. The inability of the standard model to incorporate blood flow consequently raises a need for models that include more physiology, and we develop microvascular models which remove the inconsistencies. The microvascular models can be regarded as a revision of the input function. Whereas the standard model uses the organ inlet concentration as the concentration throughout the vascular compartment, we consider models that make use of spatial averaging of the concentrations in the capillary volume, which is what the PET scanner actually registers. The microvascular models are developed for both single- and multi-capillary systems and include effects of non-exchanging vessels. They are suitable for analysing dynamic PET data from any capillary bed using either intravascular or diffusible tracers, in terms of physiological parameters which include regional blood flow. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental studies on phase equilibria and liquidus in the multicomponent system PbO-ZnO-CaO-SiO2-FeO-Fe2O3 in air have been conducted over the temperature range between 1323 K (1050 degreesC) and 1623 K (1350 degreesC) to characterize the phase relations of the complex slag systems encountered in lead and zinc blast furnace sinters. The liquidus in two pseudoternary sections ZnO-Fe2O3-(PbO + CaO + SiO2) with the CaO/SiO2 weight ratio of 0.933 and PbO/(CaO + SiO2) weight ratios of 2.0 and 3.2 have been constructed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To develop a 'quality use of medicines' coding system for the assessment of pharmacists' medication reviews and to apply it to an appropriate cohort. Method: A 'quality use of medicines' coding system was developed based on findings in the literature. These codes were then applied to 216 (111 intervention, 105 control) veterans' medication profiles by an independent clinical pharmacist who was supported by a clinical pharmacologist with the aim to assess the appropriateness of pharmacy interventions. The profiles were provided for veterans participating in a randomised, controlled trial in private hospitals evaluating the effect of medication review and discharge counselling. The reliability of the coding was tested by two independent clinical pharmacists in a random sample of 23 veterans from the study population. Main outcome measure: Interrater reliability was assessed by applying Cohen's kappa score on aggregated codes. Results: The coding system based on the literature consisted of 19 codes. The results from the three clinical pharmacists suggested that the original coding system had two major problems: (a) a lack of discrimination for certain recommendations e. g. adverse drug reactions, toxicity and mortality may be seen as variations in degree of a single effect and (b) certain codes e. g. essential therapy were in low prevalence. The interrater reliability for an aggregation of all codes into positive, negative and clinically non-significant codes ranged from 0.49-0.58 (good to fair). The interrater reliability increased to 0.72-0.79 (excellent) when all negative codes were excluded. Analysis of the sample of 216 profiles showed that the most prevalent recommendations from the clinical pharmacists were a positive impact in reducing adverse responses (31.9%), an improvement in good clinical pharmacy practice (25.5%) and a positive impact in reducing drug toxicity (11.1%). Most medications were assigned the clinically non-significant code (96.6%). In fact, the interventions led to a statistically significant difference in pharmacist recommendations in the categories; adverse response, toxicity and good clinical pharmacy practice measured by the quality use of medicine coding system. Conclusion: It was possible to use the quality use of medicine coding system to rate the quality and potential health impact of pharmacists' medication reviews, and the system did pick up differences between intervention and control patients. The interrater reliability for the summarised coding system was fair, but a larger sample of medication regimens is needed to assess the non-summarised quality use of medicines coding system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper conducts a dynamic stability analysis of symmetrically laminated FGM rectangular plates with general out-of-plane supporting conditions, subjected to a uniaxial periodic in-plane load and undergoing uniform temperature change. Theoretical formulations are based on Reddy's third-order shear deformation plate theory, and account for the temperature dependence of material properties. A semi-analytical Galerkin-differential quadrature approach is employed to convert the governing equations into a linear system of Mathieu-Hill equations from which the boundary points on the unstable regions are determined by Bolotin's method. Free vibration and bifurcation buckling are also discussed as subset problems. Numerical results are presented in both dimensionless tabular and graphical forms for laminated plates with FGM layers made of silicon nitride and stainless steel. The influences of various parameters such as material composition, layer thickness ratio, temperature change, static load level, boundary constraints on the dynamic stability, buckling and vibration frequencies are examined in detail through parametric studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Wide testing of the aldosterone: renin ratio among hypertensive individuals has revealed primary aldosteronism to be common, with most patients normokalaemic. Some investigators, however, have reported aldosterone-producing adenoma to be rare among patients so detected. Objective To test the hypothesis that differences among reported studies in the rate of detection of aldosterone-producing adenoma (as opposed to bilateral adrenal hyperplasia) reflect differences in the procedures used for diagnosis of primary aldosteronism, and the methods used to identify aldosterone-producing adenomas. Methods In the newly established Princess Alexandra Hospital Hypertension Unit (PAHHU), we used procedures developed by Greenslopes Hospital Hypertension Unit (which reports that more than 30% of patients with primary aldosteronism have aldosterone-producing adenomas) to diagnose primary aldosteronism and determine the subtype. All patients with an increased aldosterone: renin ratio (measured after correction for hypokalaemia and while the patient was not receiving interfering medications) underwent fludrocortisone suppression testing to confirm or exclude primary aldosteronism; if they were positive, they underwent genetic testing to exclude glucocorticoid-remediable aldosteronism before adrenal venous sampling was used to differentiate lateralizing from bilateral primary aldosteronism. Results This approach allowed PAHHU to diagnose, within 2 years, 54 patients [only seven (13%) hypokalaemic] with primary aldosteronism. All tested negative for glucocorticoid-remediable aldosteronism. Aldosterone production was lateralized to one adrenal in 15 patients (31%; only six hypokalaemic) and was bilateral in 34 (69%; all normokalaemic) of 49 patients who underwent adrenal venous sampling. Among patients with lateralizing adrenal hyperplasia, computed tomography revealed an ipsilateral mass in only six and a contralateral lesion in one. Fourteen patients underwent unilateral adrenalectomy, which cured the hypertension in seven and improved it in the remainder. In patients with bilateral primary aldlosteronism, hypertension responded to spironolactone (112.5-50 mg/ day) or amiloride (2.5-10 mg/day). Conclusion When performed with careful regard to confounding factors, measurement of the aldosterone: renin ratio in all hypertensive individuals, followed by fludrocortisone suppression testing to confirm or exclude primary aldosteronism and adrenal venous sampling to determine the subtype, can result in the detection of significant numbers of patients with specifically treatable or potentially curable hypertension. (C) 2003 Lippincott Williams Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of Internet Relay Chat (IRC) affords for, and itself produces, non-response situations that are not possible in FTF or telephone interaction. These system-occasioned nonresponses produce almost isomorphic stimuli to participant non-responses. Situations thus arise in which non-responses are interpersonally accountable despite agentive ambiguity. This study explores four intersections of participant-action and system-occasioned non-responses. An extension to Pomerantz's (1984b) 'pursuing a response' problems/solutions is proposed. The impact of IRC's design on its popularity is discussed in contrast to more recent chat systems. Suggestions are made for active and passive presence and non-response accounting features in future chat systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The utility of 16s rDNA restriction fragment length polymorphism (RFLP) analysis for the partial genomovar differentiation of Burkholderia cepacia complex bacterium is well documented. We compared the 16s rDNA RFLP signatures for a number of non-fermenting gram negative bacilli (NF GNB) LMG control strains and clinical isolates pertaining to the genera Burkholderia, Pseudomonas, Achromobacter (Alcaligenes), Ralstonia, Stenotrophomonas and Pandoraea. A collection of 24 control strain (LMG) and 25 clinical isolates were included in the study. Using conventional PCR, a 1.2 kbp 16s rDNA fragment was generated for each organism. Following restriction digestion and electrophoresis, each clinical isolate RFLP signature was compared to those of the control strain panel. Nineteen different RFLP signatures were detected from the 28 control strains included in the study. TwentyoneyTwenty- five of the clinical isolates could be classified by RFLP analysis into a single genus and species when compared to the patterns produced by the control strain panel. Four clinical B. pseudomallei isolates produced RFLP signatures which were indistinguishable from B. cepacia genomovars I, III and VIII. The identity of these four isolates were confirmed using B. pseudomallei specific PCR. 16s rDNA RFLP analysis can be a useful identification strategy when applied to NF GNB, particularly for those which exhibit colistin sulfate resistance. The use of this molecular based methodology has proved very useful in the setting of a CF referral laboratory particularly when utilised in conjunction with B. cepacia complex and genomovar specific PCR techniques. Species specific PCR or sequence analysis should be considered for selected isolates; especially where discrepancies between epidemiology, phenotypic and genotypic characteristics occur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work discusses the use of optical flow to generate the sensorial information a mobile robot needs to react to the presence of obstacles when navigating in a non-structured environment. A sensing system based on optical flow and time-to-collision calculation is here proposed and experimented, which accomplishes two important paradigms. The first one is that all computations are performed onboard the robot, in spite of the limited computational capability available. The second one is that the algorithms for optical flow and time-to-collision calculations are fast enough to give the mobile robot the capability of reacting to any environmental change in real-time. Results of real experiments in which the sensing system here proposed is used as the only source of sensorial data to guide a mobile robot to avoid obstacles while wandering around are presented, and the analysis of such results allows validating the proposed sensing system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A identificação e a avaliação de crianças com desenvolvimento atípico configuram um processo muito importante para subsidiar as estratégias de ensino voltadas para a promoção do potencial de aprendizagem. O interesse em relação ao prognóstico de crianças com deficiência tem impulsionado o desenvolvimento de novas tecnologias e pesquisas relacionadas à avaliação, prevenção e intervenção. Nesse contexto, torna-se relevante verificar com instrumentos adequados indicadores linguísticos, cognitivos e comportamentais, para assim traçar metas a partir daquilo que as crianças podem aprender. Dessa forma, esta pesquisa teve por objetivo verificar se a avaliação assistida informatizada se apresenta como uma modalidade de diagnóstico mais prescritivo do desenvolvimento cognitivo, quando comparada à avaliação psicométrica, na aplicação em crianças com deficiência. Na modalidade assistida há ajuda do examinador para conduzir a criança a um melhor nível de desempenho cognitivo. Participaram 11 crianças que frequentam uma instituição de atendimento clínico, em saúde, para crianças com deficiência, na Grande Vitória. Na avaliação psicométrica foram utilizados a Escala de Maturidade Mental Colúmbia computadorizada – Colúmbiacomp e o Teste de Vocabulário por Imagens Peabody - TVIPcomp. Na avaliação assistida informatizada foram aplicadas três provas voltadas para as habilidades de classificação e raciocínio analógico: Exclusão de Objetos, Exclusão de Figuras Geométricas e Jogo de Analogia de Figuras, no ambiente informatizado SINDAPSI. Protocolos de registro de fatores afetivo-motivacionais e de operações cognitivas foram utilizados durante as tarefas assistidas. Na avaliação do comportamento, o Child Behavior Checklist – CBCL foi respondido pelas mães. Dados documentais e dos instrumentos foram submetidos à análise estatística descritiva para verificar o desempenho das crianças nas duas formas de avaliação informatizada (psicométrica e assistida). Nos testes psicométricos, 64% das crianças alcançaram índice “abaixo da média” no TVIPcomp, e 55% “médio-inferior” no Colúmbiacomp. Em relação ao perfil de desempenho cognitivo, na Prova de Exclusão de Objetos computadorizada 55% das crianças foram avaliadas como “não-mantenedoras”. Na Prova de Exclusão de Figuras Geométricas computadorizada 55% da amostra foi classificada no perfil “alto-escore”, e no Jogo de Analogias de Figuras computadorizado 45% apresentou o perfil “ganhador”. A amostra demonstrou níveis de dificuldade na realização dos testes,tanto na modalidade psicométrica quanto assistida. Contudo, o desempenho nos testes assistidos foi relativamente melhor, evidenciando que o grupo se beneficiou da mediação,implementada na fase de assistência, para melhorar as habilidades cognitivas. Além disso, a apresentação informatizada dos testes apresentou-se como fator motivador para a realização e persistência nas tarefas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last fifty years, Brazil began a rapid process of structural transformation, following the first stage of industrial development in the 1930s. Currently the country integrates the small group of countries which evolved from an initial peripheral and subordinate insertion dating back to the nineteenth century, part of the most dynamic segment of the semiperiphery. But this category, intermediate between the "maturity" and "backwardness", according Modernization theorists, or between the "center" and "periphery", as theorists of the Dependence defend, has undergone a process of overcoming considerable positive progress in the direction of the group of states that dominate the current world system. In this way, during the years 2003-2010, foreign policy, along with the formulation of a new regionalism as a strategy of global integration and a new ideal model of State, has been a key factor

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to characterize how Portuguese Small and Medium Enterprises (SMEs) view the Occupational Health and Safety Management Systems (OHSMSs) certification process, after receiving the Quality Management System (QMS) certification. References were based on the ISO 9001 standard for a QMS and OHSAS 18001 for OHSMS. The method used to evaluate the implemented systems, was by form of questionnaire. Those questioned had to have a certified quality management system, an implemented OHSMS and be a SME. The questionnaire was sent to 300 SMEs; 46 responses were received and validated. Of them, only 12 SMEs had the OHSMS certificate according to OHSAS 18001. Within those 12 companies that participated: 7 SMEs are from the industrial sector; 3 belong to the electricity/telecommunications sector and 2 SMEs are from the trade/services activity sector. The size of the sample was small, but corresponds to Portuguese reality. Moreover, 34 SMEs did not have the OHSMS certificate. The questionnaire requested the main reasons for SMEs to opt for non-certification and it was related with high costs, while the main reasons to certificate were, among others, needed to eliminate or minimize risks to workers. The main benefits that Portuguese SMEs have gained from the referred certifications have been, improved working conditions, ensuring compliance with legislation and better internal communication about risks and hazards. Also presented are the main difficulties in achieving an OHSMS certification including high certification costs, difficulties motivating personnel, difficulties in changing the company’s culture and increased bureaucracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study of adult Culicidae ecology was carried out from January 1992 through January 1993 at the rice irrigation system of the Ribeira Valley Experimental Station. The adaptation of Anopheles albitarsis to the anthropic environment became evident through the adult collections made at its various habitats represented by the irrigation system and the edge of the residual pond, as well as at those made within the local patchy residual woods. Other potential disease vectors were prevalent in the irrigated system too. There were Aedes scapularis, Culex nigripalpus and Cx. ribeirensis that were collected at various habitats. Remarkable differences among their prevalences were obtained such as between the natural forest and anthropic environments. In the former An. albitarsis was practically non-existent, thus suggesting that it might be considered as eusynathropic. As the populations of other species seemed to increase in the anthropic environment, they may be regarded as hemisynanthropes. Observations suggest the hypothesis that the development of irrigated land may be a factor in the emergence of An. albitarsis, and some other species, as well as the possibility of an increase in the transmission of mosquito-borne diseases such as malaria.