948 resultados para N2O emission
Resumo:
The recently described process of simultaneous nitrification, denitrification and phosphorus removal (SNDPR) has a great potential to save capital and operating costs for wastewater treatment plants. However, the presence of glycogen-accumulating organisms (GAOs) and the accumulation of nitrous oxide (N2O) can severely compromise the advantages of this process. In this study, these two issues were investigated using a lab-scale sequencing batch reactor performing SNDPR over a 5-month period. The reactor was highly enriched in polyphosphate-accumulating organisms (PAOs) and GAOs representing around 70% of the total microbial community. PAOs were the dominant population at all times and their abundance increased, while GAOs population decreased over the study period. Anoxic batch tests demonstrated that GAOs rather than denitrifying PAOs were responsible for denitrification. NO accumulated from denitrification and more than half of the nitrogen supplied in a reactor cycle was released into the atmosphere as NO. After mixing SNDPR sludge with other denitrifying sludge, N2O present in the bulk liquid was reduced immediately if external carbon was added. We therefore suggest that the N2O accumulation observed in the SNDPR reactor is an artefact of the low microbial diversity facilitated by the use of synthetic wastewater with only a single carbon source. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
Left ventricular (LV) volumes have important prognostic implications in patients with chronic ischemic heart disease. We sought to examine the accuracy and reproducibility of real-time 3D echo (RT-3DE) compared to TI-201 single photon emission computed tomography (SPECT) and cardiac magnetic resonance imaging (MRI). Thirty (n = 30) patients (age 62±9 years, 23 men) with chronic ischemic heart disease underwent LV volume assessment with RT-3DE, SPECT, and MRI. Ano vel semi-automated border detection algorithmwas used by RT-3DE. End diastolic volumes (EDV) and end systolic volumes (ESV) measured by RT3DE and SPECT were compared to MRI as the standard of reference. RT-3DE and SPECT volumes showed excellent correlation with MRI (Table). Both RT- 3DE and SPECT underestimated LV volumes compared to MRI (ESV, SPECT 74±58 ml versus RT-3DE 95±48 ml versus MRI 96±54 ml); (EDV, SPECT 121±61 ml versus RT-3DE 169±61 ml versus MRI 179±56 ml). The degree of ESV underestimation with RT-3DE was not significant.
Resumo:
It was decided to investigate field emission from cadmium sulphide because many workers have found that the agreement between theory and experiment for this material, and other semiconductors, is poor. An electron energy analyser, similar to those used in most of the previously reported experiments, was, therefore, built. The performance of the analyser was thoroughly investigated both theoretically and practically and the results of these investigations were used in conjunction with a tungsten emitter. Excellent agreement was obtained between the usually accepted total energy distribution for tungsten and the corresponding .distribution measured with the present analyser. A method of obtaining reliable cadmium sulphide emitter was developed. These emitters were then used in the analyser and it was found that the agreement between theory and experiment was poor. Previous explanations of the lack of agreement are considered and are found to be doubtful. The theory of field emission from semiconductors is reviewed and possible reasons for the discrepancy between theory and experiment are proposed. Finally, further experiments are described which should prove or disprove the conclusions arrived at in this work.
Resumo:
In an attempt to clarify the behaviour of semi-conductor field emitters the properties of a narrow band gap material were investigated. A retarding potential analyser was built and tested using a tungsten emitter. The energy distribution of electrons emitted from single crystals of lead telluride (band gap 0.3 eV) and gallium phosphide (band gap 2.26 eV) were measured. The halfwidths of the distributions are discussed with respect to the relevant parameters for the materials. Methods of tip preparation had to be developed. The halfwidth of the energy distribution of electrons field emitted from carbon fibres was measured to be 0.21 ± 0.01 eV. A mechanism explaining the long lifetime of the emitters in poor vacuua is proposed.