996 resultados para Multicenter Evaluation
Resumo:
Demand response has gain increasing importance in the context of competitive electricity markets environment. The use of demand resources is also advantageous in the context of smart grid operation. In addition to the need of new business models for integrating demand response, adequate methods are necessary for an accurate determination of the consumers’ performance evaluation after the participation in a demand response event. The present paper makes a comparison between some of the existing baseline methods related to the consumers’ performance evaluation, comparing the results obtained with these methods and also with a method proposed by the authors of the paper. A case study demonstrates the application of the referred methods to real consumption data belonging to a consumer connected to a distribution network.
Resumo:
Journal of Cleaner Production, nº 17, p. 36-52
Resumo:
Electric power networks, namely distribution networks, have been suffering several changes during the last years due to changes in the power systems operation, towards the implementation of smart grids. Several approaches to the operation of the resources have been introduced, as the case of demand response, making use of the new capabilities of the smart grids. In the initial levels of the smart grids implementation reduced amounts of data are generated, namely consumption data. The methodology proposed in the present paper makes use of demand response consumers’ performance evaluation methods to determine the expected consumption for a given consumer. Then, potential commercial losses are identified using monthly historic consumption data. Real consumption data is used in the case study to demonstrate the application of the proposed method.
Resumo:
With the objective of standardizing a Dot Enzyme-Linked Immunosorbent Assay (Dot-ELISA) to detect antigens of fecal bacterial enteropathogens, 250 children, aged under 36 months and of both sexes, were studied; of which 162 had acute gastroenteritis. The efficacy of a rapid screening assay for bacterial enteropathogens (enteropathogenic Escherichia coli "EPEC", enteroinvasive Escherichia coli "EIEC", Salmonella spp. and Shigella spp.) was evaluated. The fecal samples were also submitted to a traditional method of stool culture for comparison. The concordance index between the two techniques, calculated using the Kappa (k) index for the above mentioned bacterial strains was 0.8859, 0.9055, 0.7932 and 0.7829 respectively. These values express an almost perfect degree of concordance for the first two and substantial concordance for the latter two, thus enabling this technique to be applied in the early diagnosis of diarrhea in infants. With a view to increasing the sensitivity and specificity of this immunological test, a study was made of the antigenic preparations obtained from two types of treatment: 1) deproteinization by heating; 2) precipitation and concentration of the lipopolysaccharide antigen (LPS) using an ethanol-acetone solution, which was then heated in the presence of sodium EDTA
Resumo:
Oxamniquine (OXA) was sucessfully encapsulated in small unilamellar vesicles using a pH gradient method. This procedure led to a high drug encapsulation efficiency (> 85%) at a drug to lipid molar ratio of 1/10. Moreover, these liposomes were found to retain encapsulated OXA efficciently under dialysis conditions at 37º C. Liposome-entrapped OXA (LOXA), OXA, and empty liposomes were tested against Schistosoma mansoni in a murine model. LOXA produced a significant reduction of the worm burden compared to the other preparations, when inoculated by subcutaneous route (s.c.) with 10 mg OXA/kg animal one day before the infection, and 3, 7, and 14 days after. However, LOXA was not effective when given 7 days before, or 35 days after infections. OXA, in the free form, was effective in relation to the untreated group, only when administered 3 days after the infection. Maximum effect of LOXA, with 97% reduction of the parasite number, was observed when the preparation was given s.c.one day before the infection. On the other hand, LOXA inoculated intraperitoneally one day before the infection didnt show any reduction of the parasite count. It can be concluded that LOXA is more effective than OXA for the treatment of experimental schistosomiasis, particularly when administered subcutaneously at a time close to the infection
Resumo:
The antigenic and allergenic chemical analysis of spore and mycelia extracts of Pisolithus tinctorius was carried out. The spores were collected from basidiocarps in plantations of Eucalyptus spp and the mycelia from culture in MNM medium. With basis on the fungus growth curve, the mycelia masses were obtained after 10, 20, 30, and 40 days of incubation, which correspond, respectively, to the beginning, middle and end of the log phase, and beginning of the decline phase. The mycelia masses, together with the spores, were submitted to the action of three extractors (Coca, Tris-HCl, and ammonium bicarbonate). The contents of carbohydrates and proteins were determined. The SDS-PAGE electrophoretical analysis revealed separate fractions in these extracts, besides common fractions, in function of cultivation time and extraction methods. The selected extracts for the allergic tests were the ones with the highest number of fractions. The prick-tests were conducted in 374 patients rural workers, eucalyptus plantation works and college students. The positivity to the "prick test" with the antigenic extract of P. tinctorius was, respectively, 3.78%, 28.20% and 6.40%. Most prick-test positive patients (82.75%) also presented symptoms of respiratory allergy (asthma and rhinitis). There was no reactivity difference when the spore and mycelia extracts were employed. The analysis of the positive patients sera revealed the presence of IgE specific to the P. tinctorius antigens. Since Pisolithus tinctorius is found as mycorrhyza of Eucalyptus spp, and this plant is used in reforestation in most countries, the importance of that fungus should be regarded as a possible cause of respiratory allergies, especially in occupationally exposed workers
Resumo:
Treatment of mucosal leishmaniasis (ML) can be controlled by clinical examination and by serologic titers by the indirect immunofluorescence serologic reaction (IISR). We studied the correlation between the presence of antigen in tissue determined by immunohistochemistry, the IISR titers and the anatomopathologic findings in fifteen patients with ML before and after healing of the lesions as determined by otorhinolaryngologic evaluation, and evaluated these parameters to determine which of them could be useful during follow-up. Tissue antigens became negative in four patients (group A) after treatment, with a statistically significant reduction or negativity of IISR titers (p<0.05). This did not occur in patients in whom the antigen persisted after treatment (group B), suggesting that serologic follow-up should be performed together with the search for tissue antigen, a combination which, to our knowledge, has not been used in previous studies. The negativity of tissue antigens and the behavior of IIRS titers in group A patients probably indicate a lower possibility of recurrence. Upon anatomopathologic examination the inflammatory process was found to persist after treatment even in group A, suggesting that the permanence of inflammatory activity even in clinically healed lesions is possibly correlated with the presence of the antigen or of some unknown factor.
Resumo:
Objectives: Describe cases of children with hepatosplenomegaly (HS) attended at the General Pediatric Teaching Ambulatory (AGER) of Instituto da Criança, São Paulo, identifying the main causes, evolution, necessity for hospitalization and/or referral to specialists. Methodology: Retrospective analysis of the records of children presenting HS on admission at AGER from September 1, 1993 to August 31, 1996. Results: Of the 89 children included (age range, 1 to 148 months; median, 24 months), 64 (72%) were referred from other services for HS investigation. Most common presenting complaints were: fever - 39 (44%); pallor - 26 (29%); weight loss - 21 (24%) and jaundice - 14 (16%). Main alterations noticed on physical examination were: pallor - 47 (53%) and short stature - 17 (19%). Anemia was diagnosed in 70 children (79%); 35 children (39%) had infections; 7 (8%) metabolic disorders and 5 (6%) neoplastic disorders. The most frequent infections were of the urinary tract - 9 (10%) and hepatitis A - 6 (7%).Thirty six children (40%) were referred to specialists, 17 of which were already diagnosed. Conclusions: Most of the children with HS present deficiency anemia associated with infections which the general pediatrician is able to diagnose. Persistence of unexplained HS for more than 2 months, especially when there is substantial volume enlargement or alteration in the organs consistency, is an indication for referral to specialists.
Resumo:
This study was conducted to assess the presence of schistosomiasis mansoni in the "Noroeste de Minas" mesoregion, an area considered non-endemic. A malacologic survey and parasitologic stool examinations were undertaken in 13 municipalities of the mesoregion. A sample of 3,283 primary school students was submitted to fecal examination by the Kato-Katz method. A total of 3,627 planorbids was collected and examined. The molluscs were identified as Biomphalaria straminea in seven municipalities (Unaí, Bonfinópolis de Minas, Paracatu, João Pinheiro, Vazante, Lagamar and Lagoa Grande) and as Biomphalaria peregrina in one (Presidente Olegário). All planorbids were negative for Schistosoma mansoni. Four students were diagnosed with schistosomiasis in the municipalities of Buritis, Formoso, Paracatu and Unaí, but none of these cases was considered autochthonous. The data obtained indicate that the "Noroeste de Minas" mesoregion continues to be non-endemic for schistosomiasis mansoni, although the presence of intermediate hosts associated with parasitized individuals emphasizes the need for epidemiological surveillance of schistosomiasis in this mesoregion.
Resumo:
World Transport Policy & Practice, Vol.6, nº2, (2000)
Resumo:
Erythromycin, a reversal agent in multidrug-resistant cancer, was assayed in chloroquine resistance modulation. The in vitro microtechnique for drug susceptibility was employed using two freshly isolates of Plasmodium falciparum from North of Brazil. The antimalarial effect of the drug was confirmed, with an IC50 estimates near the usual antimicrobial therapy concentration, and a significant statistical modulating action was observed for one isolate.
Resumo:
Anticorpos anti-Trypanosoma cruzi (isotipo IgG) foram detectados no transudato da mucosa oral (TMO) através de um ensaio imunoenzimático. Foram estudados 21 indivíduos com doença de Chagas crônica comprovada através de diagnóstico clínico, eletrocardiográfico, epidemiológico e sorológico: 10 com forma cardíaca, 2 com forma digestiva, 6 com forma mista e 3 com forma assintomática. Sete indivíduos de área endêmica, com sorologia negativa, constituiram o grupo controle. O soro destes grupos foi armazenado a -20 oC. A coleta de TMO de ambos os grupos foi realizada com o dispositivo OraSureâ seguindo orientação do fabricante (OraSureâ , Epitope Inc., Beaverton, OR, USA). As amostras de TMO foram diluídas (1:2) e testadas em duplicata através de um ensaio imunoenzimático da Abbott Laboratories para detectar anticorpos IgG contra doença de Chagas. Vinte dos vinte e um pacientes chagásicos apresentaram densidade óptica acima do limiar de reatividade e foram considerados positivos para doença de Chagas. Nenhuma das amostras provenientes de indivíduos soronegativos foi positiva. A sensibilidade e especificidade foram de 95% e 100%, respectivamente. Estes resultados indicam que TMO poderá ser utilizado como um fluido biológico alternativo para o diagnóstico da doença de Chagas. Nós estamos aumentando o número de indivíduos para validar estes resultados incluindo a análise comparativa entre amostras de TMO e soro.
Resumo:
Our objective was to compare food intake and nutritional status of Pemphigus Foliaceus patients (PG) on long term glucocorticoid therapy to a Control Group (CG). Fourteen PG female inpatients receiving prednisone (0.33 ± 0.22mg/kg) for at least 12 months and twelve CG subjects were submitted to nutritional evaluation, including anthropometry, urinary creatinine determination and serum biochemical measurements, besides 48-h-based food intake records. Groups were compared by Chi-square, Mann-Whitney and "t" tests. PG patients and CG were paired, respectively, in relation to age (24.7 ± 14.1 vs. 22.0 ± 12.0 years), body mass index (25.8 ± 6.4 vs. 24.0 ± 5.6kg/m2), daily protein intake (132.9 ± 49.8 vs. 95.2 ± 58.9g), and serum albumin (median; range) (3.8; 3.5-4.1 vs. 3.8; 3.6-5.0g/dl). However, PG patients had lower height-creatinine index (64.8 ± 17.6 vs. 90.1 ± 33.4%), and higher daily energy (3080 ± 1099 vs. 2187 ± 702kcal) and carbohydrate (376.8 ± 135.8 vs. 242.0 ± 80.7g) intakes. Despite high food, protein and energy consumption, PG patients on long term glucocorticoid therapy had lower body muscle mass than controls, while showing high body fat stores. These findings are possibly related to combined metabolic effects of long term corticotherapy and inflammatory disease plus corticosteroid-induced increased appetite.
Resumo:
Between 1992 and 1997, 790 blood donors with anti-HCV EIA-2 strongly reagent (relationship between the sample optical density/cut-off > 3) detected at the blood bank serological screening, were evaluated in ambulatory environment. They were all negative for Chagas disease, syphilis, hepatitis B (HBsAg) and AIDS. Blood samples were collected at the first ambulatorial evaluation, for hemogram, biochemical tests and new serological tests for HCV (anti-HCV EIA-2). In blood samples of 226 repeatedly reagent anti-HCV EIA-2 blood donors, supplementary "immunoblot" test for HCV (RIBA-2) was used. In 209 donors, the presence of HCV-RNA was investigated by the PCR test. The abdominal ultrasonography was realized in 366 donors. In 269 patients liver biopsy was performed for the histopathological study. The follow-up of blood donors showed that 95.6% were repeatedly EIA-2 reagent, 94% were symptomless and denied any hepatitis history, with only 2% mentioning previous jaundice. In 47% of this population at least one risk factor has been detected for the HCV transmission, the use of intravenous drugs being the main one (27.8%). Blood transfusion was the second factor for HCV transmission (27.2%). Hepatomegaly was detected in 54% of the cases. Splenomegaly and signs of portal hypertension have seldom been found in the physical examination, indicating a low degree of hepatic compromising in HCV. Abdominal ultrasound showed alterations in 65% of the subjects, being the steatosis the most frequent (50%). In 83.5% of the donors submitted to the liver biopsy, the histopathological exam showed the presence of chronic hepatitis, usually classified as active (89%) with mild or moderate grade in most of the cases (99.5%). The histopathological exam of the liver was normal in 1.5% of blood donors. The RIBA-2 test and the HCV-RNA investigation by PCR were positive in respectively 91.6 and 75% of the anti-HCV EIA-2 reagent donors. The HCV-RNA research was positive in 82% of the RIBA-2 positive subjects, in 37.5% of the indeterminate RIBA-2 donors and in 9% of the negative RIBA-2 donors. Chronic hepatitis has also been observed in 50% of the histopathological exams of the anti-HCV EIA-2 reagent donors which were indeterminate RIBA-2. Among 18 blood donors with minimal changes histopathological exam 11 (61%) were HCV-RNA positive. Our blood donors anti-HCV reagent generally had clinical, laboratorial and histopathological features observed in patients with chronic HCV hepatitis and a high proportion could be identified in interviews and medical evaluation realized in blood blanks. Generally, these HCV infected donors are identified and discharged only by the serological tests results.
Resumo:
The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.