897 resultados para Measurement in Bacteriology


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on a measurement of the inclusive jet cross section in pp̄ collisions at a center-of-mass energy s=1.96TeV using data collected by the D0 experiment at the Fermilab Tevatron Collider corresponding to an integrated luminosity of 0.70fb-1. The data cover jet transverse momenta from 50 to 600 GeV and jet rapidities in the range -2.4 to 2.4. Detailed studies of correlations between systematic uncertainties in transverse momentum and rapidity are presented, and the cross section measurements are found to be in good agreement with next-to-leading order QCD calculations. © 2008 The American Physical Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work we studied the changes of the optical constants of films in the binary system Sb2O3-Sb2S3 induced by light in the VIS-UV. The measurements were performed before and after homogeneous irradiation of the films to a Hg lamp and in real time during the holographic exposure of the samples (at 458nm). Changes of the absorption coefficient (amplitude grating) and refractive index (phase grating) were measured simultaneously using the self-diffraction using the holographic setup. Besides the films presented a strong photodarkening effect under homogeneous irradiation, the samples holographically exposed presented only refractive index modulations. None amplitude modulation was measured in real time for spatial frequencies of about 1000 l/mm. © 2009 SPIE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a general modeling approach to investigate and to predict measurement errors in active energy meters both induction and electronic types. The measurement error modeling is based on Generalized Additive Model (GAM), Ridge Regression method and experimental results of meter provided by a measurement system. The measurement system provides a database of 26 pairs of test waveforms captured in a real electrical distribution system, with different load characteristics (industrial, commercial, agricultural, and residential), covering different harmonic distortions, and balanced and unbalanced voltage conditions. In order to illustrate the proposed approach, the measurement error models are discussed and several results, which are derived from experimental tests, are presented in the form of three-dimensional graphs, and generalized as error equations. © 2009 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Purpose: The circadian rhythm of melatonin in saliva or plasma, or of the melatonin metabolite 6-sulfatoxymelatonin (a6MTs) in urine, is a defining feature of suprachiasmatic nucleus (SCN) function, the body's endogenous oscillatory pacemaker. The primary objective of this review is to ascertain the clinical benefits and limitations of current methodologies employed for detection and quantification of melatonin in biological fluids and tissues. Data Identification: A search of the English-language literature (Medline) and a systematic review of published articles were carried out. Study Selection: Articles that specified both the methodology for quantifying melatonin and indicated the clinical purpose were chosen for inclusion in the review. Data Extraction: The authors critically evaluated the methodological issues associated with various tools and techniques (e.g. standards, protocols, and procedures). Results of Data Synthesis: Melatonin measurements are useful for evaluating problems related to the onset or offset of sleep and for assessing phase delays or advances of rhythms in entrained individuals. They have also become an important tool for psychiatric diagnosis, their use being recommended for phase typing in patients suffering from sleep and mood disorders. Additionally, there has been a continuous interest in the use of melatonin as a marker for neoplasms of the pineal region. Melatonin decreases such as found with aging are or post pinealectomy can cause alterations in the sleep/wake cycle. The development of sensitive and selective methods for the precise detection of melatonin in tissues and fluids has increasingly been shown to have direct relevance for clinical decision making. Conclusions: Due to melatonin's low concentration, as well as the coexistence of numerous other compounds in the blood, the routine determination of melatonin has been an analytical challenge. The available evidence indicates however that these challenges can be overcome and consequently that evaluation of melatonin's presence and activity can be an accessible and useful tool for clinical diagnosis. © Springer-Verlag 2010.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Drell-Yan differential cross section is measured in pp collisions at √ s = 7TeV, from a data sample collected with the CMS detector at the LHC, corresponding to an integrated luminosity of 36 pb-1. The cross section measurement, normalized to the measured cross section in the Z region, is reported for both the dimuon and dielectron channels in the dilepton invariant mass range 15{600 GeV. The normalized cross section values are quoted both in the full phase space and within the detector acceptance. The effect of final state radiation is also identified. The results are found to agree with theoretical predictions. Copyright CERN.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A measurement of the lepton charge asymmetry in inclusive pp → WX production at √s = 7TeV is presented based on data recorded by the CMS detector at the LHC and corresponding to an integrated luminosity of 36 pb -1. This high precision measurement of the lepton charge asymmetry, performed in both the W → eν and W → μν channels, provides new insights into parton distribution functions. Copyright CERN.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.