891 resultados para Maternal glycemic control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A catalyst comprising a catalytic material supported on a support, characterized in that the support comprises particles predominantly having a max. particle size of less than 1000 nm and an aspect ratio of greater than, and the. catalytic material is mainly present in the form of discrete islands of catalytic material supported on the support, with a substantial proportion of the islands of catalytic material being sep. and isolated from other islands of catalytic material. The islands of catalytic material are sep. and isolated from other islands of catalytic material such that diffusion and growth of the islands of catalytic material at elevated temp. is minimized or avoided. The disclosure and examples pertain to emission control catalysts. [on SciFinder(R)]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper introduces the design of robust current and voltage control algorithms for a grid-connected three-phase inverter which is interfaced to the grid through a high-bandwidth three-phase LCL filter. The algorithms are based on the state feedback control which have been designed in a systematic approach and improved by using oversampling to deal with the issues arising due to the high-bandwidth filter. An adaptive loop delay compensation method has also been adopted to minimize the adverse effects of loop delay in digital controller and to increase the robustness of the control algorithm in the presence of parameter variations. Simulation results are presented to validate the effectiveness of the proposed algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new controller for the excitation system to improve rotor angle stability. The proposed controller uses energy function to predict desired flux for the generator to achieve improved first swing stability and enhanced system damping. The controller is designed through predicting the desired value of flux for the future step of the system and then obtaining appropriate supplementary control input for the excitation system. The simulations are performed on Single-Machine-Infinite-Bus system and the results verify the efficiency of the controller. The proposed method facilitates the excitation system with a feasible and reliable controller for severe disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for forming a material comprising a metal oxide supported on a support particle comprising the steps of: (a) providing a precursor mixt. comprising a soln. contg. one or more metal cations and (i) a surfactant; or (ii) a hydrophilic polymer; said precursor mixt. further including support particles; and (b) treating the precursor mixt. from (a) above by heating to remove the surfactant or hydrophilic polymer and form metal oxide having nanosized grains, wherein at least some of the metal oxide formed in step (b) is deposited on or supported by the support particles and the metal oxide has an oxide matrix that includes metal atoms derived solely from sources other than the support particles. The disclosure and examples pertain to emission control catalysts. [on SciFinder(R)]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose This study investigated the efficacy and safety of cryotherapy, in the form of frozen gel gloves, in relation to docetaxel-induced hand and fingernail toxicities. Patients and methods After piloting with 21 patients, a consecutive series sample of patients (n=53) prescribed docetaxel every three weeks, for a minimum of three cycles, was enrolled in this randomised control trial. Participants acted as their own control, with the frozen gel glove worn on one randomised hand for 15 minutes prior to infusion, for the duration of the infusion, and for 15 minutes of after completion of treatment. Hand and nail toxicities were evaluated by two blinded assessors according to CTCAE.v4 criteria. To assess the potential for cross-infection of multi-use gloves, microbial culture and sensitivity swabs were taken of each glove at every tenth use. Results Of the 53 participants enrolled in the main study, 21 provided evaluable data. There was a 60% withdrawal rate due to patient discomfort with the intervention. The mean incidence and severity of toxicities in all evaluable cycles in control and intervention hands respectively were erythroderma Grade 1 (5%/5%); nail discolouration Grade 1 (81%/67%); nail loss Grade 1 (19%/19%) and nail ridging Grade 1 (57%/57%). No significant differences were determined between hand conditions in terms of time to event, nor in terms of toxicity in gloved and non-gloved hands. Conclusion While cryotherapy in the form of frozen gloves for the cutaneous toxicities associated with docetaxel is safe, its limited efficacy, patient discomfort and some logistical issues preclude its use in our clinical setting.