930 resultados para Mamary ultrasound
Resumo:
Preclinical imaging has a critical role in phenotyping, in drug discovery, and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review high-resolution computed tomography (CT) also known as micro-CT for small-animal imaging. We present the principles, the technologies, the image quality parameters, and the types of applications. We show that micro-CT can be used to provide not only morphological but also functional information such as cardiac function or vascular permeability. Another way in which micro-CT can be used in the study of both function and anatomy is by combining it with other imaging modalities, such as positron emission tomography or single-photon emission tomography. Compared to other modalities, micro-CT imaging is usually regarded as being able to provide higher throughput at lower cost and higher resolution. The limitations are usually associated with the relatively poor contrast mechanisms and the radiation damage, although the use of novel nanoparticle-based contrast agents and careful design of studies can address these limitations.
Resumo:
Salt iodine content in Switzerland was raised from 7.5 to 15 mg per kg in 1980, and since then dietary iodine intake has been considered to be sufficient, even though a slight decrease due to imported food has recently been reported. The aim of this study was to establish normal values for thyroid volumes of school children who can be assumed to have had a sufficient iodine intake all their lifetime. Moreover, the present investigation was undertaken to verify that iodine sufficiency had been achieved equally in two regions each served by one of the two Swiss salt producers. Mean iodine concentration in urine spot samples from school children was 16.1 μg/dl, and it was identical in both the city of Lausanne (n=215) and the city of Solothurn (n=208). Thus it can be stated that in both cities (served by two different salt producers) iodine intake is equal and sufficient. Accordingly, thyroid volumes measured by ultrasound in school children aged 6 to 16 years were the same in both Lausanne (n=202) and Solothurn (n=207). Moreover, the age-adjusted median volumes at the 97th percentiles closely agree with and validate provisional international reference values recently proposed by the World Health Organisation and by the International Council for Control of Iodine Deficiency Disease.
Resumo:
Objective: To evaluate the practice of laparoscopic appendectomy (LA) in Italy. Methods: On behalf of the Italian Society of Young Surgeons (SPIGC), an audit of LA was carried out through a written questionnaire sent to 800 institutions in Italy. The questions concerned the diffusion of laparoscopic surgery and LA over the period 1990 through 2001, surgery-related morbidity and mortality rates, indications for LA, the diagnostic algorithm adopted prior to surgery, and use of LA among young surgeons (<40 years). Results: A total of 182 institutions (22.7%) participated in the current audit, and accounted for a total number of 26863 LA. Laparoscopic surgery is performed in 173 (95%) institutions, with 144 (83.2%) routinely performing LA. The mean interval from introduction of laparoscopic surgery to inception of LA was 3.4 ± 2.5 years. There was an emergent basis for 8809 (32.8%) LA procedures (<6 hours of admission); 10314 (38.4%) procedures were performed on an urgent basis (<24 hours of admission); while 7740 (28.8%) procedures were elective. The conversion rate was 2.1% (561 cases) and was due to intraoperative complications in 197 cases (35.1%). Intraoperative complications ranged as high as 0.32%, while postoperative complications were reported in 1.2% of successfully completed LA. The mean hospital stay for successfully completed LA was 2.5 ± 1.05 days. The highest rate of intraoperative complications was reported as occurring during the learning curve phase of their experience (in their first 10 procedures) by 39.7% of the surgeons. LA was indicated for every case of suspected acute appendiceal disease by 51.8% of surgeons, and 44.8% order abdominal ultrasound (US) prior to surgery. A gynecologic counseling is deemed necessary only by 34.5% surgeons, while an abdominal CT scan is required only by 1.5%. The procedure is completed laparoscopically in the absence of gross appendiceal inflammation by 83%; 79.8% try to complete the procedure laparoscopically in the presence of concomitant disease; while 10.4% convert to open surgery in cases of suspected malignancy. Of responding surgeons aged under 40, 76.3% can perform LA, compared to 47.3% surgeons of all age categories. Conclusions: The low response rate of the present survey does not allow us to assess the diffusion of LA in Italy, but rather to appraise its practice in centers routinely performing laparoscopic surgery. In the hands of experienced surgeons, LA has morbidity rates comparable to those of international series. The higher diagnostic yield of laparoscopy makes it an invaluable tool in the management algorithm of women of childbearing age; its advantages in the presence of severe peritonitis are less clear-cut. Surgeons remain the main limiting factor preventing a wider diffusion of LA in our country, since only 47.3% of surgeons from the audited institutions can perform LA on a routine basis.
Resumo:
Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.
Resumo:
This paper concerns the use of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste and specifically, the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of paste materials at the molecular level. Ultrasonic techniques are a widely used and a reliable form of non-destructive testing of materials. This is because techniques such as ultrasounds while used for testing or monitoring material properties, has offered immense benefits in applications where access to the sample is restricted or when handling the sample for testing could interfere with the monitoring or analysis process. Very often, this would mean that the measurements taken are not a true representation of the behaviour of the material (due to externally incorporated changes into the material's physical state during the removal or testing process). Ultrasonic based techniques are being increasingly used for quality control and production monitoring functions which requires evaluation of the changes in material properties over wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough, and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capacity to take rapid measurements in systems which are optically opaque. The viscometer and rheometer are two of the most widely used rheological instruments used in industry for monitoring the quality of solder pastes, during the production and packaging stage. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. It is for these reasons that materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers) are keen to see the development of simple, easy to use and accurate techniques for the theological characterisation of solder pastes. The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.
Resumo:
This paper investigates the application of a non-destructive ultrasonic technique for characterising the rheological properties of solder paste through the use of through-mode microsecond ultrasonic pulses for evaluation of viscoelastic properties of lead-free solder paste containing different types of flux. Ultrasonic techniques offer a robust and reliable form of non-destructive testing of materials where access to the sample is restricted or when sample handling can interfere with the monitoring or analysis process due to externally incorporated changes to the material’s physical state or accidental contamination during the removal or testing process. Ultrasonic based techniques are increasingly used for quality control and production monitoring functions which requires evaluation of changes in material properties for a wide range of industrial applications such as cement paste quality, plastic/polymer extrusion process, dough and even sugar content in beverage drinks. In addition, ultrasound techniques are of great interest for their capability to take rapid measurements in systems which are optically opaque. The conventional industry approach for characterising the rheological properties of suspensions during processing/packaging stage is mainly through the use of viscometer and some through the use of rheometer. One of the potential limitations of viscometer and rheometer based measurements is that the collection and preparation of the solder paste samples can irreversibly alter the structure and flow behaviour of the sample. Hence the measurement may not represent the actual quality of the whole production batch. Secondly, rheological measurements and the interpretation of rheological data is a very technical and time consuming process, which requires professionally trained R&D personnel. The ultrasound technique being proposed provides simple, yet accurate and easy to use solution for the in-situ rheological characterisation of solder pastes which will benefit the materials suppliers (who formulate and produce solder pastes) and solder paste consumers (especially, contract electronics manufacturers). The results from the work show that the technique can be used by R&D personnel involved in paste formulation and manufacture to monitor the batch-to-batch quality and consistency.
Resumo:
The ultrasonic measurement and imaging of tissue elasticity is currently under wide investigation and development as a clinical tool for the assessment of a broad range of diseases, but little account in this field has yet been taken of the fact that soft tissue is porous and contains mobile fluid. The ability to squeeze fluid out of tissue may have implications for conventional elasticity imaging, and may present opportunities for new investigative tools. When a homogeneous, isotropic, fluid-saturated poroelastic material with a linearly elastic solid phase and incompressible solid and fluid constituents is subjected to stress, the behaviour of the induced internal strain field is influenced by three material constants: the Young's modulus (E(s)) and Poisson's ratio (nu(s)) of the solid matrix and the permeability (k) of the solid matrix to the pore fluid. New analytical expressions were derived and used to model the time-dependent behaviour of the strain field inside simulated homogeneous cylindrical samples of such a poroelastic material undergoing sustained unconfined compression. A model-based reconstruction technique was developed to produce images of parameters related to the poroelastic material constants (E(s), nu(s), k) from a comparison of the measured and predicted time-dependent spatially varying radial strain. Tests of the method using simulated noisy strain data showed that it is capable of producing three unique parametric images: an image of the Poisson's ratio of the solid matrix, an image of the axial strain (which was not time-dependent subsequent to the application of the compression) and an image representing the product of the aggregate modulus E(s)(1-nu(s))/(1+nu(s))(1-2nu(s)) of the solid matrix and the permeability of the solid matrix to the pore fluid. The analytical expressions were further used to numerically validate a finite element model and to clarify previous work on poroelastography.
Resumo:
Purpose: We investigated the potential for improvement in disease control by use of autologous peripheral blood stem cell transplant (PBSCT) to permit administration of high activities of 186Re-hydroxyethylidene diphosphonate (HEDP) in patients with progressive hormone-refractory prostate cancer (HRPC).
Methods: Eligible patients had progressive HRPC metastatic to bone, good performance status and minimal soft tissue disease. Patients received 5,000 MBq of 186Re-HEDP i.v., followed 14 days later by PBSCT. Response was assessed using PSA, survival, pain scores and quality of life.
Results: Thirty-eight patients with a median age of 67 years (range 50–77) and a median PSA of 57 ng/ml (range 4–3,628) received a median activity of 4,978 MBq 186Re-HEDP (range 4,770–5,100 MBq). The most serious toxicity was short-lived grade 3 thrombocytopenia in 8 (21%) patients. The median survival of the group is 21 months (95%CI 18–24 months) with Kaplan-Meier estimated 1- and 2-year survival rates of 83% and 40% respectively. Thirty-one patients (81%, 95% CI 66–90%) had stable or reduced PSA levels 3 months post therapy while 11 (29%, 95% CI 15–49%) had PSA reductions of >50% lasting >4 weeks. Quality of life measures were stable or improved in 27 (66%) at 3 months.
Conclusion: We have shown that it is feasible and safe to deliver high-activity radioisotope therapy with PBSCT to men with metastatic HRPC. Response rates and survival data are encouraging; however, further research is needed to define optimal role of this treatment approach.