969 resultados para MTR REACTOR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the study was to synthesize the urea (13CO(NH2)2), with 99% 13C atoms, and to perform a quality analysis for the diagnosis (breath test) of Helicobacter pylori. Furthermore, the process was submitted to economic analysis. The reaction was performed in a stainless steel reactor, lined with polytetrafluoroethylene, under low pressure and temperature. The synthesis method was shown to be appropriate (2.35 g; 81.9% yield), evidenced by physico-chemical and microbiological results, according to Brazilian legislation. The production and diagnosis costs were competitive compared with national and international market values, rendering this a valuable tool in clinical medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium dioxide nanostructured catalysts (nanotubes) doped with different metals (silver, gold, copper, palladium and zinc) were synthesized by the hydrothermal method in order to promote an increase in their photocatalytic activity under visible light. The catalysts were characterized by X-ray diffraction, diffuse reflectance spectroscopy, transmission electron microscopy and specific area and pore volume determination. The materials' photocatalytic activity was evaluated by rhodamine B decomposition in a glass batch reactor. Under UV radiation, only nanotubes doped with palladium were more active than the TiO2 P25, but the samples doped with silver, palladium and gold exhibited better results than the undoped samples under visible light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we present an efficient and inexpensive device for undergraduate chemistry classes aimed at teaching and learning the photolytic synthesis concepts. A photochemical reactor was tested for the synthesis of the organometallic compound enneacarbonyldiiron from iron pentacarbonyl in acetic acid, and its formation evidenced by FTIR analysis. Although similar devices have been described in other studies, none of these offered the simplicity, low cost, class-compatible reaction times and good yields afforded by the procedure reported herein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultraviolet radiation corresponds to a fraction of electromagnetic radiation, covering wavelengths between 1 and 400 nm. Methods based on UV irradiation have become popular because it is possible to treat samples simply by applying energy, avoiding procedures that require the use of toxic substances, thus contributing to the development of Green Chemistry. This study aimed to assess the main applications of UV radiation reported in the literature and thoroughly described the construction of an alternative and low-cost photochemical reactor to be used for the pretreatment of samples in the laboratory. The use of this new photochemical reactor in the clean-up of milk samples for spectrofluorimetric measurements was also reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of different heterogeneous catalysts on the microwave-assisted transesterification of sunflower oil for the production of methylic biodiesel in a monomode microwave reactor is described. The experiments were carried out at 70 ºC with a 16:1 methanolsunflower oil molar ratio and different heterogeneous basic and acidic catalysts. The results showed that the microwave-heated reactions occur up to four times faster than those carried out with conventional heating. The reactions were performed with 24 catalysts; pure calcium oxide (CaO) and potassium carbonate, either pure or supported by alumina (K2CO3/Al2O3), were the most efficient catalysts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the development of a new catalytic reactor designed to operate with nanoparticle-embedded polymer thin films. Stabilization of metal nanoparticles in films that serve as catalysts in organic reactions is relatively new; therefore, the development of reactors to facilitate their use is necessary. We describe in detail the preparation of the GDCR reactor-type "dip catalyst" and its evaluation in the Suzuki - Miyaura cross-coupling reaction of phenylboronic acid and 4-bromoanisole catalyzed by palladium nanoparticle-embedded cellulose acetate thin film (CA/PD(0)). Compared with earlier prototypes, GDCR reactor showed excellent results when operating with CA/PD(0) thin films.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The impacts derived from the emission of volatile organic compounds (VOC) into the atmosphere can have harmful consequences for human health and the environment. In this regard, the present paper proposes the construction of a low-cost cold plasma reactor for the treatment of these compounds. Tests with the prototype were performed to confirm the efficiency for BTEX (benzene, toluene and xylene) samples. Degradation efficiency was confirmed by the gas chromatography method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work investigated the effect of microwave irradiation (MW) on the ethanolysis rate of soybean and sunflower oils catalyzed by supported Novozyme 435 (Candida antarctica). The effects of tert-butanol, water addition and oil:ethanol molar ratio on transesterification were evaluated under conventional heating (CH), and under optimum reaction conditions (with no added water in the system, 10% tert-butanol and 3:1 ethanol-to-oil molar ratio). The reactions were monitored up to 24 h to determine the conditions of initial reaction velocity. The investigated variables under MW (50 W) were: reaction time (5.0-180 min) and mode of reactor operation (fixed power, dynamic and cycles) in the absence and presence of tert-butanol (10% (w/w). The measured response was the reaction conversion in ethyl esters, which was linked to the enzyme catalytic activity. The results indicated that the use of microwave improved the activity at fixed power mode. A positive effect of the association of tert-butanol and MW irradiation on the catalytic activity was observed. The reaction rate improved in the order of approximately 1.5 fold compared to that under CH with soybean oil. Using soybean oil, the enzymatic transesterification under MW for conversion to FAEE (fatty acid ethyl esters) reached >99% in 3h, while with the use of CH the conversions were about 57% under similar conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zirconia was prepared by a precipitation method and calcined at 723 K, 1023 K, and 1253 K in order to obtain monoclinic zirconia. The prepared zirconia was characterized by XRD, SEM, EDX, surface area and pore size analyzer, and particle size analyzer. Monoclinic ZrO2 as a catalyst was used for the gas-phase oxidation of isopropanol to acetone in a Pyrex-glass-flow-type reactor with a temperature range of 443 K - 473 K. It was found that monoclinic ZrO2 shows remarkable catalytic activity (68%) and selectivity (100%) for the oxidation of isopropanol to acetone. This kinetic study reveals that the oxidation of isopropanol to acetone follows the L-H mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mild anodization (MA) reactor is exemplified for its operational simplicity and its excellent control over the experimental parameters that are involved in the anodization process. This method provides porous anodic alumina films with a regular cell-arrangement structure. This offers a better cost-benefit ratio than the other equipment configurations that are used to fabricate nanoporous structures (i.e., ion beam lithography). Conversely, the hard anodization (HA) reactor produces oxides at a rate that is 25 to 35 times faster than the MA reactor. The produced oxides also have greater layer thicknesses and interpore distance, and with a uniform nanopore spatial order (> 1000). In contrast to MA reactors, the construction of an HA reactor requires special components to maintain anodisation at a high potential regime. Herein, we describe and compare both reactors from a technical viewpoint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research was motivated by the need to examine the potential application areas of process intensification technologies in Neste Oil Oyj. According to the company’s interest membrane reactor technology was chosen and applicability of this technology in refining industry was investigated. Moreover, Neste Oil suggested a project which is related to the CO2 capture from FCC unit flue gas stream. The flowrate of the flue gas is 180t/h and consist of approximately 14% by volume CO2. Membrane based absorption process (membrane contactor) was chosen as a potential technique to model CO2 capture from fluid catalytic cracking (FCC) unit effluent. In the design of membrane contactor, a mathematical model was developed to describe CO2 absorption from a gas mixture using monoethanole amine (MEA) aqueous solution. According to the results of literature survey, in the hollow fiber contactor for laminar flow conditions approximately 99 % percent of CO2 can be removed by using a 20 cm in length polyvinylidene fluoride (PDVF) membrane. Furthermore, the design of whole process was performed by using PRO/II simulation software and the CO2 removal efficiency of the whole process obtained as 97 %. The technical and economical comparisons among existing MEA absorption processes were performed to determine the advantages and disadvantages of membrane contactor technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työssä käydään läpi säteilyhaurastumisilmiöitä ja niistä johtuvia vaikutuksia kevytvesilaitosten reaktoripainesäiliöille

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.