992 resultados para MESENTERIC-ARTERIES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is a chronic process that evolves over decades and may culminate in myocardial infarction (MI). While invasive coronary angiography (ICA) is still considered the gold standard of imaging CAD, non-invasive assessment of both the vascular anatomy and myocardial perfusion has become an intriguing alternative. In particular, computed tomography (CT) and positron emission tomography (PET) form an attractive combination for such studies. Increased radiation dose is, however, a concern. Our aim in the current thesis was to test novel CT and PET techniques alone and in hybrid setting in the detection and assessment of CAD in clinical patients. Along with diagnostic accuracy, methods for the reduction of the radiation dose was an important target. The study investigating the coronary arteries of patients with atrial fibrillation (AF) showed that CAD may be an important etiology of AF because a high prevalence of CAD was demonstrated within AF patients. In patients with suspected CAD, we demonstrated that a sequential, prospectively ECG-triggered CT technique was applicable to nearly 9/10 clinical patients and the radiation dose was over 60% lower than with spiral CT. To detect the functional significance of obstructive CAD, a novel software for perfusion quantification, CarimasTM, showed high reproducibility with 15O-labelled water in PET, supporting feasibility and good clinical accuracy. In a larger cohort of 107 patients with moderate 30-70% pre-test probability of CAD, hybrid PET/CT was shown to be a powerful diagnostic method in the assessment of CAD with diagnostic accuracy comparable to that of invasive angiography and fractional flow reserve (FFR) measurements. A hybrid study may be performed with a reasonable radiation dose in a vast majority of the cases, improving the performance of stand-alone PET and CT angiography, particularly when the absolute quantification of the perfusion is employed. These results can be applied into clinical practice and will be useful for daily clinical diagnosis of CAD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to simulate blood flow in thoracic human aorta and understand the role of flow dynamics in the initialization and localization of atherosclerotic plaque in human thoracic aorta. The blood flow dynamics in idealized and realistic models of human thoracic aorta were numerically simulated in three idealized and two realistic thoracic aorta models. The idealized models of thoracic aorta were reconstructed with measurements available from literature, and the realistic models of thoracic aorta were constructed by image processing Computed Tomographic (CT) images. The CT images were made available by South Karelia Central Hospital in Lappeenranta. The reconstruction of thoracic aorta consisted of operations, such as contrast adjustment, image segmentations, and 3D surface rendering. Additional design operations were performed to make the aorta model compatible for the numerical method based computer code. The image processing and design operations were performed with specialized medical image processing software. Pulsatile pressure and velocity boundary conditions were deployed as inlet boundary conditions. The blood flow was assumed homogeneous and incompressible. The blood was assumed to be a Newtonian fluid. The simulations with idealized models of thoracic aorta were carried out with Finite Element Method based computer code, while the simulations with realistic models of thoracic aorta were carried out with Finite Volume Method based computer code. Simulations were carried out for four cardiac cycles. The distribution of flow, pressure and Wall Shear Stress (WSS) observed during the fourth cardiac cycle were extensively analyzed. The aim of carrying out the simulations with idealized model was to get an estimate of flow dynamics in a realistic aorta model. The motive behind the choice of three aorta models with distinct features was to understand the dependence of flow dynamics on aorta anatomy. Highly disturbed and nonuniform distribution of velocity and WSS was observed in aortic arch, near brachiocephalic, left common artery, and left subclavian artery. On the other hand, the WSS profiles at the roots of branches show significant differences with geometry variation of aorta and branches. The comparison of instantaneous WSS profiles revealed that the model with straight branching arteries had relatively lower WSS compared to that in the aorta model with curved branches. In addition to this, significant differences were observed in the spatial and temporal profiles of WSS, flow, and pressure. The study with idealized model was extended to study blood flow in thoracic aorta under the effects of hypertension and hypotension. One of the idealized aorta models was modified along with the boundary conditions to mimic the thoracic aorta under the effects of hypertension and hypotension. The results of simulations with realistic models extracted from CT scans demonstrated more realistic flow dynamics than that in the idealized models. During systole, the velocity in ascending aorta was skewed towards the outer wall of aortic arch. The flow develops secondary flow patterns as it moves downstream towards aortic arch. Unlike idealized models, the distribution of flow was nonplanar and heavily guided by the artery anatomy. Flow cavitation was observed in the aorta model which was imaged giving longer branches. This could not be properly observed in the model with imaging containing a shorter length for aortic branches. The flow circulation was also observed in the inner wall of the aortic arch. However, during the diastole, the flow profiles were almost flat and regular due the acceleration of flow at the inlet. The flow profiles were weakly turbulent during the flow reversal. The complex flow patterns caused a non-uniform distribution of WSS. High WSS was distributed at the junction of branches and aortic arch. Low WSS was distributed at the proximal part of the junction, while intermedium WSS was distributed in the distal part of the junction. The pulsatile nature of the inflow caused oscillating WSS at the branch entry region and inner curvature of aortic arch. Based on the WSS distribution in the realistic model, one of the aorta models was altered to induce artificial atherosclerotic plaque at the branch entry region and inner curvature of aortic arch. Atherosclerotic plaque causing 50% blockage of lumen was introduced in brachiocephalic artery, common carotid artery, left subclavian artery, and aortic arch. The aim of this part of the study was first to study the effect of stenosis on flow and WSS distribution, understand the effect of shape of atherosclerotic plaque on flow and WSS distribution, and finally to investigate the effect of lumen blockage severity on flow and WSS distributions. The results revealed that the distribution of WSS is significantly affected by plaque with mere 50% stenosis. The asymmetric shape of stenosis causes higher WSS in branching arteries than in the cases with symmetric plaque. The flow dynamics within thoracic aorta models has been extensively studied and reported here. The effects of pressure and arterial anatomy on the flow dynamic were investigated. The distribution of complex flow and WSS is correlated with the localization of atherosclerosis. With the available results we can conclude that the thoracic aorta, with complex anatomy is the most vulnerable artery for the localization and development of atherosclerosis. The flow dynamics and arterial anatomy play a role in the localization of atherosclerosis. The patient specific image based models can be used to diagnose the locations in the aorta vulnerable to the development of arterial diseases such as atherosclerosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intestinal complications after laparoscopic cholecystectomy are rare and usually caused by direct injury sustained on trocar insertion. However, intestinal ischaemia has been reported as an unusual complication of the pneumoperitoneum. We describe a 55-years-old patient who underwent an uneventful laparoscopic cholecystectomy after an episode of acute cholecystitis. Initial recovery was complicated by development of increasing abdominal pain which led to open laparotomy on day 2. Gangrene of the distal ileum and right-sided colon was detected and small bowel resection with right colectomy and primary anastomosis was performed. Histological examination of the resected ileum showed features of venous hemorragic infarction and trombosis. In view of the proximity of the operation it is assumed that ileal ischaemia was precipitated by carbon dioxide pneumoperitoneum. Some studies have been demonstrated that, within 30 minutes of establishing a pneumoperitoneum at an intraabdominal pressure of 16 mmHg, cardiac output, blood flow in the superior mesenteric artery and portal vein decrease progressively. Carbon dioxide pneumoperitoneum may lead to mechanical compression of the splanchnic veins and mesenteric vasoconstriction as a result of carbon dioxide absortion. The distribution of the ischaemic segment of intestine is also unusual as the most precarious blood supply is traditionally at the splenic flexure of the colon. It has been suggested that intermittent decompression of the abdomen reduces the risk of mesenteric ischaemia during penumoperitoneum especially in patients with predisposing clinical features for arteriosclerosis intestinal. In present patient was observed intestinal venous infarction what remains unclear but we think the carbon dioxide pneumoperitoneum have been related to it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Superior Mesenteric Syndrome is a rare and controversial disease. The compression of the duodenum by the mesenteric artery and aorta causes an intermitent obstruction. Preoperative diagnosis is very difficult.We present one case of this syndrome in a pacient with severe weight loss and signs of high intestinal obstruction. The diagnosis was based on clinical and radiologic findings. A duodenojejunostomy was performed after medical treatment failure.This patient died on the 20th posoperative day due to cardiac complications. This syndrome must be remembered in cases of high obstruction in chronic ill patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mesenteric cyst is a rare intra abdominal pathology. The incidence ranges from 1/100,000 to 1/250,000 hospital admissions. The authors present a case of a female patient, 20 years old, with abdominal pain for four months which three days had an acute onset of abdominal pain, and ultrasound revealed a cyst of mesentery within a dense fluid. The patient had been submitted to a laparotomy, and resection of the cyst. We emphasized the clinical symptoms, diagnostic evaluation and the therapeutic of this condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Appendiceal tumors are rare and usually presented as acute appendicitis. They are incidentally discovered at an emergency surgery, in which case the decision-making is very difficult. The purpose of this report is discuss to the most appropriate management for appendiceal tumors. A retrospective analysis of one case treated at HU-UEL was undertaken and the literature was reviewed. The conclusion is that frozen section should be done whenever the appendiceal findings are atypical. For appendiceal carcinoids greater than 2 cm and adenocarcinomas, a right hemicolectomy is recommended. Appendectomy is apropriate for patients whose carcinoid tumors are 1 cm in diameter or less and for carcinoid tumors between 1 cm and 2 cm without extensive lymphatic permeation and mesenteric invasion. Every case should be searched for synchronous tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report a case of thrombosis of common and internal carotid arteries caused by blunt trauma. They emphasize the rarity of this lesion and the variability of clinical presentation. Different forms of treatment are analysed, such as the use of anticoagulation and surgery. Treatment needs to be individualized for each patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Superior mesenteric vein invasion has historically been considered a contraindication for pancreatic cancer resection. Several studies have shown that in selected cases vascular resection can be performed safely. Many techniques have been used to reconstruct the venous flow. We describe one case of mesenteric superior vein resection and reconstrution of mesenteric-portal venous flow using the splenic vein during a pancreatoduodenectomy for pancreatic adenocarcinoma. The patient presented an extensive involvement of the superior mesenteric vein. A segmental resection with an end-to-end anastomosis of this vein and the splenic vein was accomplished after splenectomy. The patient had histologically confirmed negative margins. There was no hospital complications. These results show that the splenic vein can be an option for venous flow reconstruction when a segmental vascular resection is required during at pancreaticoduodenectomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Videolaparoscopy has been widely used in the treatment of pathologies as cholelithiasis, appendicitis and adrenal tumor. Nowadays, has also been used to treat type II endoleaks after endovascular repair of abdominal aortic aneurysms. The goal of this work is to report one case of inferior mesenteric artery endoleak treated by videolaparoscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mesenteric cyst is a rare abdominal disease, with a higher incidence among women and 1: 250.000 incidence among hospitalized adults and 1: 200.000 among hospitalized children. Thereby, we report a case of a 10 years old child, male, presenting a large mesenteric cyst, which occupied almost all the abdominal and pelvic cavities and treated by resection during laparotomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis focuses on tissue inhibitor of metalloproteinases 4 (TIMP4) which is the newest member of a small gene and protein family of four closely related endogenous inhibitors of extracellular matrix (ECM) degrading enzymes. Existing data on TIMP4 suggested that it exhibits a more restricted expression pattern than the other TIMPs with high expression levels in heart, brain, ovary and skeletal muscle. These observations and the fact that the ECM is of special importance to provide the cardiovascular system with structural strength combined with elasticity and distensibility, prompted the present molecular biologic investigation on TIMP4. In the first part of the study the murine Timp4 gene was cloned and characterized in detail. The structure of murine Timp4 genomic locus resembles that in other species and of the other Timps. The highest Timp4 expression was detected in heart, ovary and brain. As the expression pattern of Timp4 gives only limited information about its role in physiology and pathology, Timp4 knockout mice were generated next. The analysis of Timp4 knockout mice revealed that Timp4 deficiency has no obvious effect on the development, growth or fertility of mice. Therefore, Timp4 deficient mice were challenged using available cardiovascular models, i.e. experimental cardiac pressure overload and myocardial infarction. In the former model, Timp4 deficiency was found to be compensated by Timp2 overexpression, whereas in the myocardial infarct model, Timp4 deficiency resulted in increased mortality due to increased susceptibility for cardiac rupture. In the wound healing model, Timp4 deficiency was shown to result in transient retardation of re-epithelialization of cutaneous wounds. Melanoma tumor growth was similar in Timp4 deficient and control mice. Despite of this, lung metastasis of melanoma cells was significantly increased in Timp4 null mice. In an attempt to translate the current findings to patient material, TIMP4 expression was studied in human specimens representing different inflammatory cardiovascular pathologies, i.e. giant cell arteritis, atherosclerotic coronary arteries and heart allografts exhibiting signs of chronic rejection. The results showed that cardiovascular expression of TIMP4 is elevated particularly in areas exhibiting inflammation. The results of the present studies suggest that TIMP4 has a special role in the regulation of tissue repair processes in the heart, and also in healing wounds and metastases. Furthermore, evidence is provided suggesting the usefulness of TIMP4 as a novel systemic marker for vascular inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a case of non-resectable head pancreatic cancer by mesenteric venous invasion in which treatment with Gemcitabine (Gemzar) 1.000 mg/m 2 weekly for 3 weeks, followed by a 1-week rest, normalized CA 19.9 and promoted tumor resecability in a second operation (ultrasound, helicoidal tomography and magnetic ressonance exams). The value of the adjuvant treatment (radiochemotherapy) and the association with immunotherapy (Interferon) is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osteochondromas are the most common benign tumor of the bone. They are sometimes responsible for vascular complications involving either veins or arteries, principally around the knee. Pseudoaneurysms are considered a rare condition. The authors describe the occurrence of a pseudoaneurysm of the popliteal artery in association with a femoral osteochondroma in a 30-years-old man.