1000 resultados para Lounasmaa, Olli V
Resumo:
Invocatio: Q.F.F.Q.S.
Resumo:
In this investigation antioxidant response and toxicity of metals in receiving water effluent miner in the Blanco river in Pseudokirchneriella subcapitata was assessed. The catalase activity, lipid damage through Tbars, the growth rate of was determined. The result showed an inhibition of the growth rate of P. subcapitata which correlated with increased catalase activity and the lipid liperoxidation. These responses were correlated with the concentrations of copper and iron.
Resumo:
Invocatio: Divina favente gratia.
Resumo:
Invocatio: Q.F.F.Q.S.
Resumo:
Invocatio: Q.B.V.D.T.O.M.
Resumo:
Invocatio: Q.F.S.F.Q.
Resumo:
Invocatio: I.N.J.
Resumo:
This paper describes the adsorption of heavy metals ions from aqueous solution by hydrous niobium oxide. Three heavy metals were selected for this study: cadmium, lead and silver. Adsorption isotherms were well fitted by Langmuir model. Maximum adsorption capacity (Q0) for Pb2 +, Ag+ and Cd2 + was found to be 452.5, 188.68 and 8.85 mg g-1, respectively.
Resumo:
Invocatio: I.N.S.S.T.
Resumo:
In this work, hydrotalcite, a layered double hydroxide, had its adsorption and ion exchange properties combined with the magnetic properties of iron oxide to produce a magnetic adsorbent, HT-Fe. The removal of As(V) by a HT-Fe adsorbent was evaluated under various conditions. The Kinetic process was well described by a pseudo-second order rate model. The maximum adsorption capacity, calculated with the Langmuir model showed to be dependent on pH, reaching values of 24.09, 10.19 and 7.44 mg g-1, respectively, for pH values of 4.0, 7.0 and 9.0. The inhibition by competition of anions is dependent on the type of ionic species.
Resumo:
A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.