943 resultados para Laboratories diagnostic
Resumo:
Human Papillomavirus (HPV) is the cause of cervical cancers (among these, adenocarcinoma, AdCa) and is associated to a subgroup of oropharyngeal carcinomas (OPSCCs). Even if the risk for cancer development is linked to the infection by some viral genotypes, mainly HPV16 and 18, viral DNA alone seems not to be sufficient for diagnosis. Moreover, the role of the virus in OPSCCs has not been totally clarified yet. In the first part of the thesis, the performances concerning viral genotyping in clinical cervical samples of a new pyrosequencing-based test and a well-known hybridization-based assay have been compared. Similar results between the methods have been obtained. However, the former showed advantages in detecting intratype variants, higher specificity and a broader spectrum of detectable HPV types. The second part deals with the evaluation of virological markers (genotyping, viral oncoproteins expression, viral load, physical state and CpG methylation of HPV16 genome) in the diagnosis/prognosis of cervical AdCa and HPV-associated OPSCCs. HPV16 has been confirmed the most prevalent genotype in both the populations. Interestingly, the mean methylation frequency of viral DNA at the early promoter showed the tendency to be associated to invasion for cervical AdCa and to a worse prognosis for OPSCCs, suggesting a promising role as diagnostic/prognostic biomarker. The experiments of the third part were performed at the DKFZ in Heidelberg (Germany) and dealt with the analysis of the response to IFN-k transfection in HPV16-positive cervical cancer and head&neck carcinoma cell lines to evaluate its potential role as new treatment. After 24h, we observed increased IFN-b expression which lead to the up-regulation of genes involved in the antigens presentation pathway (MHC class I and immunoproteasome) and antiviral response as well, in particular in cervical cancer cell lines. This fact suggested also the presence of different HPV-mediated carcinogenic pathways between the two anatomical districts.
Resumo:
The safety systems of nuclear power plants rely on low-voltage power, instrumentation and control cables. Inside the containment area, cables operate in harsh environments, characterized by relatively high temperature and gamma-irradiation. As these cables are related to fundamental safety systems, they must be able to withstand unexpected accident conditions and, therefore, their condition assessment is of utmost importance as plants age and lifetime extensions are required. Nowadays, the integrity and functionality of these cables are monitored mainly through destructive test which requires specific laboratory. The investigation of electrical aging markers which can provide information about the state of the cable by non-destructive testing methods would improve significantly the present diagnostic techniques. This work has been made within the framework of the ADVANCE (Aging Diagnostic and Prognostics of Low-Voltage I\&C Cables) project, a FP7 European program. This Ph.D. thesis aims at studying the impact of aging on cable electrical parameters, in order to understand the evolution of the electrical properties associated with cable degradation. The identification of suitable aging markers requires the comparison of the electrical property variation with the physical/chemical degradation mechanisms of polymers for different insulating materials and compositions. The feasibility of non-destructive electrical condition monitoring techniques as potential substitutes for destructive methods will be finally discussed studying the correlation between electrical and mechanical properties. In this work, the electrical properties of cable insulators are monitored and characterized mainly by dielectric spectroscopy, polarization/depolarization current analysis and space charge distribution. Among these techniques, dielectric spectroscopy showed the most promising results; by means of dielectric spectroscopy it is possible to identify the frequency range where the properties are more sensitive to aging. In particular, the imaginary part of permittivity at high frequency, which is related to oxidation, has been identified as the most suitable aging marker based on electrical quantities.
Resumo:
Environmental decay in porous masonry materials, such as brick and mortar, is a widespread problem concerning both new and historic masonry structures. The decay mechanisms are quite complex dependng upon several interconnected parameters and from the interaction with the specific micro-climate. Materials undergo aesthetical and substantial changes in character but while many studies have been carried out, the mechanical aspect has been largely understudied while it bears true importance from the structural viewpoint. A quantitative assessment of the masonry material degradation and how it affects the load-bearing capacity of masonry structures appears missing. The research work carried out, limiting the attention to brick masonry addresses this issue through an experimental laboratory approach via different integrated testing procedures, both non-destructive and mechanical, together with monitoring methods. Attention was focused on transport of moisture and salts and on the damaging effects caused by the crystallization of two different salts, sodium chloride and sodium sulphate. Many series of masonry specimens, very different in size and purposes were used to track the damage process since its beginning and to monitor its evolution over a number of years Athe same time suitable testing techniques, non-destructive, mini-invasive, analytical, of monitoring, were validated for these purposes. The specimens were exposed to different aggressive agents (in terms of type of salt, of brine concentration, of artificial vs. open-air natural ageing, …), tested by different means (qualitative vs. quantitative, non destructive vs. mechanical testing, punctual vs. wide areas, …), and had different size (1-, 2-, 3-header thick walls, full-scale walls vs. small size specimens, brick columns and triplets vs. small walls, masonry specimens vs. single units of brick and mortar prisms, …). Different advanced testing methods and novel monitoring techniques were applied in an integrated holistic approach, for quantitative assessment of masonry health state.
Resumo:
Aim of this study is to describe the possible diagnostic value of sleep disturbances in the differential diagnosis of neurodegenerative diseases characterized by parkinsonism at onset. 42 consecutive patients with parkinsonian features and disease duration up to 3 years were included in the BO-ProPark study. Each patient was evaluated twice, at baseline (T0) and 16 months later (T1). Patients were diagnosed as Parkinson disease (PD, 27 patients), PD plus (PD with cognitive impairment/dementia or dysautonomia, 4 patients) and parkinsonian syndrome (PS, 11 patients). All patients underwent a full night video-polysomnography scored by a neurologist blinded to the clinical diagnosis. Sleep efficiency and total sleep time were reduced in all patients; wake after sleep onset was higher in patients with atypical parkinsonisms than in PD patients. No significant differences between groups of patients were detected in other sleep parameters. The mean percentage of epochs with enhanced tonic muscle EMG activity during REM sleep was higher in PD plus and PS than in PD. No difference in phasic muscle EMG activity during REM sleep was seen between the two groups. REM behaviour disorder was more frequent in PD plus and PS than in PD patients. Our data suggest that REM sleep motor control is more frequently impaired at disease onset in patients with PS and PD plus compared to PD patients. The presence of RBD or an enhanced tonic muscle EMG activity in a patient with recent onset parkinsonian features should suggest a diagnosis of atypical parkinsonism, rather than PD. More data are needed to establish the diagnostic value of these features in the differential diagnosis of parkinsonisms. The evaluation of sleep disorders may be a useful tool in the differential diagnosis of parkinsonism at onset.
Resumo:
Background. Hhereditary cystic kidney diseases are a heterogeneous spectrum of disorders leading to renal failure. Clinical features and family history can help to distinguish the recessive from dominant diseases but the differential diagnosis is difficult due the phenotypic overlap. The molecular diagnosis is often the only way to characterize the different forms. A conventional molecular screening is suitable for small genes but is expensive and time-consuming for large size genes. Next Generation Sequencing (NGS) technologies enables massively parallel sequencing of nucleic acid fragments. Purpose. The first purpose was to validate a diagnostic algorithm useful to drive the genetic screening. The second aim was to validate a NGS protocol of PKHD1 gene. Methods. DNAs from 50 patients were submitted to conventional screening of NPHP1, NPHP5, UMOD, REN and HNF1B genes. 5 patients with known mutations in PKHD1 were submitted to NGS to validate the new method and a not genotyped proband with his parents were analyzed for a diagnostic application. Results. The conventional molecular screening detected 8 mutations: 1) the novel p.E48K of REN in a patient with cystic nephropathy, hyperuricemia, hyperkalemia and anemia; 2) p.R489X of NPHP5 in a patient with Senior Loken Syndrome; 3) pR295C of HNF1B in a patient with renal failure and diabetes.; 4) the NPHP1 deletion in 3 patients with medullar cysts; 5) the HNF1B deletion in a patient with medullar cysts and renal hypoplasia and in a diabetic patient with liver disease. The NGS of PKHD1 detected all known mutations and two additional variants during the validation. The diagnostic NGS analysis identified the patient’s compound heterozygosity with a maternal frameshift mutation and a paternal missense mutation besides a not transmitted paternal missense mutation. Conclusions. The results confirm the validity of our diagnostic algorithm and suggest the possibility to introduce this NGS protocol to clinical practice.
Resumo:
La prima parte del nostro studio riguarda la tecnica LAMP (Loop-mediated isothermal amplification), una tecnica di amplificazione isotermica recentemente inventata (Notomi et al., 2000). Essa presenta notevoli vantaggi rispetto alle tradizionali PCR: non necessita di strumentazioni sofisticate come i termociclatori, può essere eseguita da personale non specializzato, è una tecnica altamente sensibile e specifica ed è molto tollerante agli inibitori. Tutte queste caratteristiche fanno sì che essa possa essere utilizzata al di fuori dei laboratori diagnostici, come POCT (Point of care testing), con il vantaggio di non dover gestire la spedizione del campione e di avere in tempi molto brevi risultati paragonabili a quelli ottenuti con la tradizionale PCR. Sono state prese in considerazione malattie infettive sostenute da batteri che richiedono tempi molto lunghi per la coltivazione o che non sono addirittura coltivabili. Sono stati disegnati dei saggi per la diagnosi di patologie virali che necessitano di diagnosi tempestiva. Altri test messi a punto riguardano malattie genetiche del cane e due batteri d’interesse agro-alimentare. Tutte le prove sono state condotte con tecnica real-time per diminuire il rischio di cross-contaminazione pur riuscendo a comprendere in maniera approfondita l’andamento delle reazioni. Infine è stato messo a punto un metodo di visualizzazione colorimetrico utilizzabile con tutti i saggi messi a punto, che svincola completamente la reazione LAMP dall’esecuzione in un laboratorio specializzato. Il secondo capitolo riguarda lo studio dal punto di vista molecolare di un soggetto che presenza totale assenza di attività mieloperossidasica all’analisi di citochimica automatica (ADVIA® 2120 Hematology System). Lo studio è stato condotto attraverso amplificazione e confronto dei prodotti di PCR ottenuti sul soggetto patologico e su due soggetti con fenotipo wild-type. Si è poi provveduto al sequenziamento dei prodotti di PCR su sequenziatore automatico al fine di ricercare la mutazione responsabile della carenza di MPO nel soggetto indicato.
Resumo:
This thesis work deals, principally, with the development of different chemical protocols ranging from environmental sustainability peptide synthesis to asymmetric synthesis of modified tryptophans to a series of straightforward procedures for constraining peptide backbones without the need for a pre-formed scaffold. Much efforts have been dedicated to the structural analysis in a biomimetic environment, fundamental for predicting the in vivo conformation of compounds, as well as for giving a rationale to the experimentally determined bioactivity. The conformational analyses in solution has been done mostly by NMR (2D gCosy, Roesy, VT, titration experiments, molecular dynamics, etc.), FT-IR and ECD spectroscopy. As a practical application, 3D rigid scaffolds have been employed for the synthesis of biological active compounds based on peptidomimetic and retro-mimetic structures. These mimics have been investigated for their potential as antiflammatory agents and actually the results obtained are very promising. Moreover, the synthesis of Amo ring permitted the development of an alternative high effective synthetic pathway for obtaining Linezolid antibiotic. The final section is, instead, dedicated to the construction of a new biosensor based on zeolite L SAMs functionalized with the integrin ligand c[RGDfK], that has showed high efficiency for the selective detection of tumor cells. Such kind of sensor could, in fact, enable the convenient, non-invasive detection and diagnosis of cancer in early stages, from a few drops of a patient's blood or other biological fluids. In conclusion, the researches described herein demonstrate that the peptidomimetic approach to 3D definite structures, allows unambiguous investigation of the structure-activity relationships, giving an access to a wide range bioactive compounds of pharmaceutical interest to use not only as potential drugs but also for diagnostic and theranostic applications.
Resumo:
Since its approval by FDA in 2001, capsule endoscopy revolutionized the study of small bowel. One of the main limitations of its diffusion has been the high cost. More recently, a new videocapsule system (OMOM CE) has been developed in China and obtained the CE mark. Its cost is approximately half that of other capsule systems. However, there are few studies regarding the clinical experience with this new videocapsule system and none of them has been performed in the western world. Among the limitations of capsule endoscopy, there is also one linked to the diagnostic yield. The rapid transit of the device in the proximal segments implies a high risk of false negatives; an indirect confirmation of this limit is offered by the poor ability to identify the papilla of Vater. In addition, recent studies show that in patients with obscure gastrointestinal bleeding, the negative outcome of capsule endoscopy is correlated to a significant risk of recurrence of anemia in the short term, as well as the presence of small bowel lesions documented by a second capsule endoscopy. It was recently approved the use of a new device called "CapsoCam" (CapsoVision, Inc. Saratoga) characterized by four side cameras that offer a panoramic view of 360 degrees, instead of the front to 160°. Two recent pilot studies showed comparable safety profiles and diagnostic yield with the more standardized capsule. Namely, side vision has made possible a clear visualization of the papilla in 70% of cases. The aim of our study is to evaluate the feasibility and diagnostic yield of these two new devices, which first may allow a reduction in costs. Moreover, their complementary use could lead to a recovery diagnostic in patients with false negative results in an initial investigation.
Resumo:
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.
Resumo:
To evaluate, in a prospective pilot study, the feasibility of identifying pathogens in urine using real-time polymerase chain reaction (PCR), and to compare the results with the conventional urine culture-based procedures.
Resumo:
In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.
Resumo:
To prospectively evaluate a 3-dimensional spoiled gradient-dual-echo (3D SPGR-DE) magnetic resonance imaging (MRI) sequence for the qualitative and quantitative analysis of liver fat content (LFC) in patients with the suspicion of fatty liver disease using histopathology as the standard of reference.