899 resultados para LESS-THAN -5.0


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dilution refrigerator has been constructed capable of producing steady state temperatures less than .075°K. The first part of this work is concerned with the design and construction of this machine. Enough theory is presented to allow one to understand the operation and critical design factors of a dilution refrigerator. The performance of our refrigerator is compared with the operating characteristics of three other dilution refrigerators appearing in the present literature.

The dilution refrigerator constructed was used to measure the nuclear contribution to the low temperature specific heat of a pure, single-crystalline sample of rhenium metal. Measurements were made in magnetic fields from 0 to 12.5 kOe for the temperature range .13°K - .52°K. The second part of this work discusses the results of these experiments. The expected nuclear contribution is not found when the sample is in the superconducting state. This is believed to be due to the long spin-lattice relaxation times in superconductors. In the normal state, for the temperature range studied, the nuclear contribution is given by A/T2 where A = .061 ± .002 millijoules-K/mole. The value of A is found to increase to A = .077 ± .004 millijoules-K/mole when the sample is located in a magnetic field of 12.5 kOe.

From the measured value of A the splitting of the energy levels of the nuclear spin system due to the interaction of the internal crystalline electric field gradients with the nuclear quadrupole moments is calculated. A comparison is made between the predicted and measured magnetic dependence of the specific heat. Finally, predictions are made of future nuclear magnetic resonance experiments which may be performed to check the results obtained by calorimetery here and further, to investigate existing theories concerning the sources of electric field gradients in metals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lowest T = 2 states have been identified and studied in the nuclei 12C, 12B, 20F and and 28Al. The first two of these were produced in the reactions 14C(p,t)12C and 14C (p,3He)12B, at 50.5 and 63.4 MeV incident proton energy respectively, at the Oak Ridge National Laboratory. The T = 2 states in 20F and 28Al were observed in (3He,p) reactions at 12-MeV incident energy, with the Caltech Tandem accelerator.

The results for the four nuclei studied are summarized below:

(1) 12C: the lowest T = 2 state was located at an excitation energy of 27595 ± 20 keV, and has a width less than 35 keV.

(2) 12B: the lowest T = 2 state was found at an excitation energy of 12710 ± 20 keV. The width was determined to be less than 54 keV and the spin and parity were confirmed to be 0+. A second 12B state (or doublet) was observed at an excitation energy of 14860 ± 30 keV with a width (if the group corresponds to a single state) of 226 ± 30 keV.

(3) 20F: the lowest T = 2 state was observed at an excitation of 6513 ± 5 keV; the spin and parity were confirmed to be 0+. A second state, tentatively identified as T = 2 from the level spacing, was located at 8210 ± 6 keV.

(4) 28Al: the lowest T = 2 state was identified at an excitation of 5997 ± 6 keV; the spin and parity were confirmed to be 0+. A second state at an excitation energy of 7491 ± 11 keV is tentatively identified as T = 2, with a corresponding (tentative) spin and parity assignment Jπ = 2+.

The results of the present work and the other known masses of T = 2 states and nuclei for 8 ≤ A ≤ 28 are summarized, and massequation coefficients have been extracted for these multiplets. These coefficients were compared with those from T = 1 multiplets, and then used to predict the mass and stability of each of the unobserved members of the T = 2 multiplets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

I. ELECTROPHORESIS OF THE NUCLEIC ACIDS

A zone electrophoresis apparatus using ultraviolet optics has been constructed to study nucleic acids at concentrations less than 0.004%. Native DNA has a mobility about 15% higher than denatured DNA over a range of conditions. Otherwise, the electrophoretic mobility is independent of molecular weight, base composition or source. DNA mobilities change in the expected way with pH but the fractional change in mobility is less than the calculated change in charge. A small decrease in mobility accompanies an increase in ionic strength. RNA’s from various sources have mobilities slightly lower than denatured DNA except for s-RNA which travels slightly faster. The important considerations governing the mobility of nucleic acids appear to be the nature of the hydrodynamic segment, and the binding of counterions. The differences between electrophoresis and sedimentation stem from the fact that all random coil polyelectrolytes are fundamentally free draining in electrophoresis.

II. THE CYTOCHROME C/DNA COMPLEX

The basic protein, cytochrome c, has been complexed to DNA. Up to a cytochrome:DNA mass ratio of 2, a single type of complex is formed. Dissociation of this complex occurs between 0.05F and 0.1F NaCl. The complexing of cytochrome to DNA causes a slight increase in the melting temperature of the DNA, and a reduction of the electrophoretic mobility proportional to the decrease in net charge. Above a cytochrome:DNA mass ratio of 2.5, a different type of complex is formed. The results suggest that complexes such as are formed in the Kleinschmidt technique of electron microscopy would not exist in bulk solution and are exclusively film phenomena.

III. STUDIES OF THE ELECTROPHORESIS AND MELTING BEHAVIOUR OF NUCLEOHISTONES

Electrophoresis studies on reconstituted nucleohistones indicate that the electrophoretic mobility for these complexes is a function of the net charge of the complex. The mobility is therefore dependent on the charge density of the histone complexing the DNA, as well as on the histone/DNA ratio. It is found that the different histones affect the transition from native to denatured DNA in different ways. It appears that histone I is exchanging quite rapidly between DNA molecules in 0.01 F salt, while histone II is irreversibly bound. Histone III-IV enhances the capacity of non-strand separated denatured DNA to reanneal. Studies on native nucleoproteins indicate that there are no gene-sized uncomplexed DNA regions in any preparations studied.

IV. THE DISSOCIATION OF HISTONE FROM CALF THYMUS CROMATIN

Calf thymus nucleoprotein was treated with varying concentrations of NaCl. The identity of the histones associated and dissociated from the DNA at each salt concentration was determined by gel electrophoresis. It was found that there is no appreciable histone dissociation below 0.4 F NaCl. The lysine rich histones dissociate between 0.4 and 0.5 F NaCl. Their dissociation is accompanies by a marked increase in the solubility of the chromatin. The moderately lysine rich histones dissociate mainly between 0.8 and 1.1 F NaCl. There are two arginine rich histone components: the first dissociates between 0.8 F and 1.1 F NaCl, but the second class is the very last to be dissociated from the DNA (dissociation beginning at 1.0 F NaCl). By 2.0 F NaCl, essentially all the histones are dissociated.

The properties of the extracted nucleoprotein were studied. The electrophoretic mobility increases and the melting temperature decreases as more histones are dissociated from the DNA. A comparison with the dissociation of histones from DNA in NaClO4 shows that to dissociate the same class of histones, the concentration of NaCl required is twice that of NaClO4.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first part of this thesis combines Bolocam observations of the thermal Sunyaev-Zel’dovich (SZ) effect at 140 GHz with X-ray observations from Chandra, strong lensing data from the Hubble Space Telescope (HST), and weak lensing data from HST and Subaru to constrain parametric models for the distribution of dark and baryonic matter in a sample of six massive, dynamically relaxed galaxy clusters. For five of the six clusters, the full multiwavelength dataset is well described by a relatively simple model that assumes spherical symmetry, hydrostatic equilibrium, and entirely thermal pressure support. The multiwavelength analysis yields considerably better constraints on the total mass and concentration compared to analysis of any one dataset individually. The subsample of five galaxy clusters is used to place an upper limit on the fraction of pressure support in the intracluster medium (ICM) due to nonthermal processes, such as turbulent and bulk flow of the gas. We constrain the nonthermal pressure fraction at r500c to be less than 0.11 at 95% confidence, where r500c refers to radius at which the average enclosed density is 500 times the critical density of the Universe. This is in tension with state-of-the-art hydrodynamical simulations, which predict a nonthermal pressure fraction of approximately 0.25 at r500c for the clusters in this sample.

The second part of this thesis focuses on the characterization of the Multiwavelength Sub/millimeter Inductance Camera (MUSIC), a photometric imaging camera that was commissioned at the Caltech Submillimeter Observatory (CSO) in 2012. MUSIC is designed to have a 14 arcminute, diffraction-limited field of view populated with 576 spatial pixels that are simultaneously sensitive to four bands at 150, 220, 290, and 350 GHz. It is well-suited for studies of dusty star forming galaxies, galaxy clusters via the SZ Effect, and galactic star formation. MUSIC employs a number of novel detector technologies: broadband phased-arrays of slot dipole antennas for beam formation, on-chip lumped element filters for band definition, and Microwave Kinetic Inductance Detectors (MKIDs) for transduction of incoming light to electric signal. MKIDs are superconducting micro-resonators coupled to a feedline. Incoming light breaks apart Cooper pairs in the superconductor, causing a change in the quality factor and frequency of the resonator. This is read out as amplitude and phase modulation of a microwave probe signal centered on the resonant frequency. By tuning each resonator to a slightly different frequency and sending out a superposition of probe signals, hundreds of detectors can be read out on a single feedline. This natural capability for large scale, frequency domain multiplexing combined with relatively simple fabrication makes MKIDs a promising low temperature detector for future kilopixel sub/millimeter instruments. There is also considerable interest in using MKIDs for optical through near-infrared spectrophotometry due to their fast microsecond response time and modest energy resolution. In order to optimize the MKID design to obtain suitable performance for any particular application, it is critical to have a well-understood physical model for the detectors and the sources of noise to which they are susceptible. MUSIC has collected many hours of on-sky data with over 1000 MKIDs. This work studies the performance of the detectors in the context of one such physical model. Chapter 2 describes the theoretical model for the responsivity and noise of MKIDs. Chapter 3 outlines the set of measurements used to calibrate this model for the MUSIC detectors. Chapter 4 presents the resulting estimates of the spectral response, optical efficiency, and on-sky loading. The measured detector response to Uranus is compared to the calibrated model prediction in order to determine how well the model describes the propagation of signal through the full instrument. Chapter 5 examines the noise present in the detector timestreams during recent science observations. Noise due to fluctuations in atmospheric emission dominate at long timescales (less than 0.5 Hz). Fluctuations in the amplitude and phase of the microwave probe signal due to the readout electronics contribute significant 1/f and drift-type noise at shorter timescales. The atmospheric noise is removed by creating a template for the fluctuations in atmospheric emission from weighted averages of the detector timestreams. The electronics noise is removed by using probe signals centered off-resonance to construct templates for the amplitude and phase fluctuations. The algorithms that perform the atmospheric and electronic noise removal are described. After removal, we find good agreement between the observed residual noise and our expectation for intrinsic detector noise over a significant fraction of the signal bandwidth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The major nonhistone chromosomal proteins (NHC proteins) are a group of 14-20 acidic proteins associated with DNA in eukaryotic chromatin. In comparisons by SDS gel electrophoresis (molecular weight sieving) one observes a high degree of homology among the NHC protein fractions of different tissues from a given species. Tissue-specific protein bands are also observed. The appearance of a new NHC protein, A, in the NHC proteins of rat liver stimulated to divide by partial hepatectomy and of rat ascites cells suggests that this protein may play a role in preparing the cell for division. The NHC proteins of the same tissue from different species are also very similar. Quantitative but not qualitative changes in the NHC proteins of rat uterus are observed on stimulation (in vivo) with estrogen. These observations suggest that the major NHC proteins play a general role in chromatin structure and the regulation of genome expression; several may be enzymes of nucleic acid and histone metabolism and/or structural proteins analogous to histones. One such enzyme, a protease which readily and preferentially degrades histones, can be extracted from chromatin with 0.7 N NaCl.

Although the NHC proteins readily aggregate, they can be separated from histone and fractionated by ion exchange chromatography on Sephadex SE C-25 resin in 10 M urea-25% formic acid (pH 2.5). Following further purification, four fractions of NHC protein are obtained; two of these are single purified proteins, and the other two contain 4-6 and 4-7 different proteins. These NHC proteins show a ratio of acidic to basic amino acids from 2.7 to 1.2 and isoelectric points from apparently less than 3.7 to 8.0. These isolated fractions appear more soluble and easier to work with than any whole NHC protein preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

光路自动准直系统应用于惯性约束聚变的高功率激光装置中的光束自动调整。图像处理是光路自动准直的关键技术之一。针对神光Ⅲ原型装置,结合阈值化、重心法、中值滤波和圆拟合等多种不同的图像处理方法设计了一套合理的准直方案,并且在模拟实验平台上进行了实验验证。实验结果表明,光路自动准直系统能够在15min之内顺利完成光路的自动调整,光束近场调整精度优于近场光斑的±0.5%,光束远场调整精度≤±0.3″,满足了原型装置的总体要求。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Apesar do potencial anticárie do dentifrício fluoretado na dentição permanente estar bem estabelecido, existe uma lacuna no conhecimento em relação ao seu efeito na dentição decídua; não existe consenso quanto à concentração ideal de fluoreto no dentifrício capaz de maximizar o benefício anticárie na dentição decídua e simultaneamente minimizar o risco de desenvolver fluorose clinicamente importante na dentição permanente. O artigo 1 desta tese avaliou o efeito dos dentifrícios de concentração baixa (menos de 600 ppm) e padrão (1000 a 1500 ppm) de fluoreto comparados com placebo ou nenhuma intervenção e o artigo 2 comparou diretamente o efeito do dentifrício de concentração baixa de fluoreto com o de concentração padrão. Foi realizada uma revisão sistemática de ensaios clínicos randomizados ou quasi-randomizados. Dois examinadores leram, de forma independente, 1932 resumos ou citações e 159 estudos na íntegra. As discordâncias foram resolvidas por um terceiro examinador. Oito estudos foram incluídos no artigo 1 e cinco no artigo 2. Para avaliar o efeito dos dentifrícios fluoretados sobre o número de dentes e superfícies dentárias cariadas, perdidas por cárie e obturadas, e sobre o número de crianças com cárie e fluorose, foram estimados frações prevenidas (FP) e riscos relativos (RR) combinados, respectivamente. Quando os dentifrícios de concentração padrão de fluoreto foram comparados com placebo ou nenhuma intervenção, houve reduções significativas de cárie no nível de superfície (FP= 31%; IC 95% 18 43), dente (FP= 16%; IC 95% 7 24) e indivíduo (RR= 0,86; IC 95% 0,81 0,93). Quando os dentifrícios de concentração baixa de fluoreto foram comparados com nenhuma intervenção, houve redução significativa de cárie apenas no nível de superfície (FP= 40%; IC 95% 5 75) (artigo 1). Os dentifrícios de concentração baixa de fluoreto, comparados diretamente com os de concentração padrão, aumentaram significativamente o risco de cárie na dentição decídua (RR= 1,13; IC 95% 1,07 1,20) e não reduziram significativamente o risco de fluorose clinicamente importante nos dentes permanentes anteriores superiores (RR= 0,32; IC 95% 0,03 2,97). Houve uma redução significativa de cárie no nível de dente quando o dentifrício com concentração padrão de fluoreto foi comparado com o de baixa concentração (FP=14%; IC 95% 6 21). Porém, não houve diferença no nível de superfície, apesar de ter havido uma tendência favorecendo os dentifrícios com concentração padrão de fluoreto e pH neutro (FP= 13%; IC 95% -4 30) e os de concentração baixa de fluoreto e pH ácido (FP= -5%; IC 95% -22 11) (artigo 2). Os dentifrícios de concentração padrão de fluoreto foram mais efetivos na redução de cárie na dentição decídua de pré-escolares do que os de concentração baixa, placebo ou nenhuma intervenção. Os dentifrícios de concentração padrão de fluoreto, em comparação com os de concentração baixa, não aumentaram significativamente o risco de fluorose clinicamente importante nos dentes permanentes anteriores superiores. São necessários mais estudos para confirmar se a redução do pH dos dentifrícios de concentração baixa de fluoreto pode ser considerada uma alternativa para aumentar o efeito anticárie e reduzir o risco de fluorose clinicamente importante.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As preocupações com o meio ambiente em particular com a água, adquirem especial importância, porque as demandas estão se tornando cada vez maiores, sob o aspecto crescente da população e das atividades industriais. Quando se fala em água subterrânea, a primeira ideia que surge é que ela seja potável. Mas nem sempre isso é uma verdade. Em área urbana, os crescentes números de problemas devido a contaminação, na maioria das vezes por vazamentos de combustíveis oriundos dos tanques de armazenamento dos postos de gasolina. Sem falar nas indústrias que também oferecem potencial risco de contaminação para esses corpos hídricos e são pouco divulgadas. O presente trabalho tem como foco determinar os compostos clorobenzenos por cromatografia de fase gasosa com headspace (CG-HS) em matriz água e validar a metodologia. A metodologia usada neste estudo foi cromatografia de fase gasosa com headspace (CG HS), por ser uma técnica excelente e sensível e é utilizada para determinar compostos voláteis em baixas concentrações. Os dados obtidos foram tratados estatisticamente de modo avaliar a seletividade, os limites de detecção e quantificação, a faixa linear de trabalho, a linearidade e a recuperação. As recuperações variam de 80 a 110%, os coeficientes de variação obtidos foram menor que 20%, todas as substâncias estudadas apresentaram linearidade na faixa de trabalho de 0,8 a 100g.L-1. Foram estudadas 10 amostras de água subterrânea do Município do Rio de Janeiro e nas amostras analisadas foram encontrados todos os compostos em estudo, com faixa de concentração: monoclorobenzeno (<0,8 a 2,988g.L-1); 1,3-diclorobenzeno (<0,8 a 23,067g.L-1); 1,4-diclorobenzeno (nd a 16,160g.L-1); 1,2-diclorobenzeno (<0,8 a 48,685g.L-1); 1,3,5-triclorobenzeno (<0,8 a 21,900g.L-1); 1,2,4-triclorobenzeno (1,007 a 183,808g.L-1) e 1,2,3-triclorobenzeno (<0,8 a 126,886g.L-1)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

高精度时间间隔测量单元(TIU)是星载激光测距仪的关键部件。基于现场可编程门阵列(FPGA)研制出了满足星载要求的高精度、高集成度时间间隔测量单元。该单元采用数字计数法结合数字延迟线插入法的技术,在0.5~10 km的测量距离范围内,时间分辨率为500 ps。通过地面检测,在全程范围内保持了良好的线性度,标准偏差小于270 ps。该单元同时具备测量脉冲回波宽度的能力,可以获取目标的脉冲展宽信息。由于单元选用的元器件都具有航天产品性能,因此其设计和技术指标可满足星载激光测距仪的应用。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo tem como tema central o ganho de peso e o consumo alimentar no período reprodutivo. A tese está dividida em três partes: i) revisão da literatura científica sobre os fatores de risco para o ganho de peso excessivo na gestação e para a sua retenção no pós-parto; ii) análise quantitativa e qualitativa do consumo alimentar (energia, nutrientes e alimentos) do período gestacional para o pós-parto; e iii) avaliação prospectiva da associação entre a dieta hiperproteica (≥ 1.2 g/kg) e a variação de peso pós-gestacional. A revisão da literatura apontou como principais determinantes da variação de peso no pós-parto os seguintes fatores: ganho de peso gestacional, peso pré-gestacional, dieta, atividade física, lactação, idade, escolaridade, renda, paridade e raça. As partes ii e iii correspondem a dois artigos, sendo que a população do estudo empregada nas duas análises foi baseada em uma coorte de mulheres no pós-parto atendidas no Centro Municipal de Saúde (CMS) Marcolino Candau, localizado no Município do Rio de Janeiro. Dentre as 709 mulheres convidadas para participar da pesquisa, 479 ingressaram na coorte. As mulheres foram recrutadas através dos serviços de pré-natal e na rotina pediátrica de imunização do BCG, oferecidos pelo CMS, e imediatamente após o parto, na maternidade central de referência. A coleta de dados ocorreu entre maio de 1999 e abril de 2001, sendo 15 meses de recrutamento e 9 meses de seguimento. As mulheres foram entrevistadas aos 15 dias, 2, 6 e 9 meses do pós-parto. Foram consideradas elegíveis para as duas analises as mulheres com idade entre 18 e 45 anos de idade, entrevistadas até 30 dias do pós-parto, sem doenças crônicas pré-existentes, com gravidez de 35 ou mais semanas gestacionais e sem gestação gemelar. O estudo sobre a composição da dieta do período gestacional para o pós-parto contou com 276 mulheres que responderam aos dois questionários de freqüência de consumo alimentar (QFCA) aplicados aos 15 dias e aos 6 meses do seguimento. Os resultados mostraram que as mulheres consumiram dietas mais energéticas na gravidez e aquelas que mais restringiram o consumo de energia no pós-parto, apresentaram um incremento na densidade de proteínas da dieta. As análises das medidas repetidos do peso foram realizadas para avaliar o efeito da dieta hiperproteica (≥ 1.2 g/kg) sobre a variação de peso no pós-parto, para as quais haviam dados de uma amostra de 430 mulheres. Os resultados mostraram que as mulheres com dieta hiperproteica perderam mais peso do que as mulheres com dieta normo ou hipoproteica (< 1.2 g/kg) (226 g/mês versus 123 g/mês). As duas analises indicam que um pequeno incremento no consumo de proteínas promove maior perda de peso. Estudos longitudinais futuros devem incluir avaliação relativa a segurança das dietas hiperproteicas no pós-parto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wind error of the double-edge technique Doppler lidar due to the instability of injection-seeding solid laser and the drift of interferometer s spectrum was analyzed. Corresponding numerical simulation indicated that if the wind error of 1 m/s was achieved, the unsuccessful injection-seeding pulses should be less than 0.06% in integration time of 5 min. (30000 pulses). In the respect of spectrum drift of the interferometer, double temperature control systems were used and the accuracy of minus or plus 0.002°C was obtained, corresponding to the wind error of minus or plus 0.226 m/s. Monitoring of buildup time of the injection-seeding laser and temperature of the interferometer was significantly to improve the invertion accuracy of wind error by rejecting the data with frequency jumping and drifting. Researches of injection-seeding and spectrum stability of the interferometer were practical for the development of double-edge wind lidar.}

Relevância:

100.00% 100.00%

Publicador:

Resumo:

报道了利用声光振幅调制锁模的方法,在激光二极管端面抽运Nd:YVO4激光器上获得320MHz高重复频率脉冲列的实验结果。实验采用平一平腔结构,腔长452mm,耦合输出镜透过率为3.6%。所用声光介质为熔融石英晶体,以铌酸锂作换能器,在驱动功率4.5W时,对1064nm波长衍射效率为50,相应的调制深度为0.31。在最佳锁模状态下,激光二极管抽运功率为3.5W,此时激光平均输出功率为15mw。示波器记录脉冲宽度680ps,实测光束质量因子M^2小于1.5。并在实验基础上对激光器工作的稳定性进行了分析,结果表

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出了基于菲佐干涉仪和多通道光电倍增管(PMT)阵列探测器组合的多普勒频移检测的方案, 适用于风速测量的直接探测多普勒激光雷达。首先介绍了工作原理, 再根据菲佐干涉仪光谱特征对频移检测用干涉仪进行了优化设计, 优化设计的菲佐干涉仪腔长150mm、平板反射率0.755。对提出的菲佐干涉仪和多通道光电倍增管阵列探测器组合的方案进行了数值模拟, 以分子散射作为背景噪声, 计算了该方法的风速测量误差。模拟结果表明, 设计的基于菲佐干涉仪的直接探测多普勒测风激光雷达, 在30 s的积分时间内、探测高度5 km以下,

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho são apresentados os procedimentos de caracterização de um sistema comercial portátil de Fluorescência de Raios X por dispersão em energia, o ARTAX 200, bem com seu processo de calibração. O sistema é composto por um tubo de Raios X, com anodo de Molibdênio e um detector XFlash (Silicon Drift Detector) refrigerado por Efeito Peltier. O procedimento de caracterização do sistema foi realizado utilizando-se uma amostra de referência contendo Ferro e Cromo. Foram também usadas amostras certificadas (National Bureau of Standards) D840, D845, D846, D847 e D849 para a realização do processo de calibração do sistema para análise quantitativa. O processo de calibração foi realizado por três metodologias diferentes a fim de avaliar qual deles apresentaria melhores resultados. A caracterização do sistema ARTAX 200 foi realizada executando testes de estabilidade do tubo de Raios X, repetibilidade, reprodutibilidade, resolução em energia do sistema, levantamento da curva de limite de detecção e verificação do centro geométrico do feixe (CG). Os resultados obtidos nos testes de estabilidade apresentaram um coeficiente de variação médio menor do que 2%, o teste de repetibilidade apresentou valores médios menores que 0,5 %. A reprodutibilidade apresentou um coeficiente de variação médio menor que 1,5%. A verificação do centro geométrica mostrou que o CG encontra-se alinhada com o centro ótimo do feixe em duas das três direções do plano cartesiano. A resolução em energia do sistema para a energia de 5,9 keV foi de 150 eV. O limite de detecção apresentou valores menores que 1 % do Si ao Cu. Na avaliação das metodologias para calibração verificou-se que uma das metodologias aplicadas apresentou melhor resultado. Comparando os resultados com outros sistemas portáteis de XRF observa-se que o ARTAX 200 apresenta eficiência superior em relação aos parâmetros analisados.