999 resultados para Kuntsi-Vaattovaara, Helena
Resumo:
Twenty-seven healthy captive lions (Panthera leo) and 13 healthy captive tigers (Panthera tigris) from S to Paulo Zoo (Fundacao Parque Zoologico de Rio Paulo, Sao Paulo, Brazil) collection were selected for this study. They were anesthetized with ketamine (10 mg/kg) combined with xylazine (1-2 mg/kg) for physical examinations. hematologic and serum chemical analysis and electrocardiogram recording. The main aim of this research was to gather initial information about normal electrocardiographic parameters of large felids. Standard P-QRS-T deflections on leads described for domestic carnivores were analyzed, and they did not greatly differ from those of large felids. taking into account the greater weight and corporal mass of large felids. Heart rate of lions ranged frorn 42 to 76 beats per minute (bpm). Heart rate of tigers ranged from 56 to 97 bpm. In both species, the most common rhythm detected was normal sinus rhythm followed by sinus arrhythmia: wandering, pacemaker was also observed with normal sinus rhythm or sinus arrhythmia. Mean electrical axis lay between +60 degrees and +120 degrees. QRS complexes were predominantly positive in leads DI, DII, DIII, and AVF and negative in AVR and AVL. This Study provides insights into normal electrocardiograms of large felids. Wider investigations on the same subject arc necessary to establish criteria for the recognition of abnormalities in these species and should include other anesthetic drug(s) combinations and reports of electrocardiographic features of animals with cardiac disease and electrolytes disturbances.
Resumo:
The present study aimed to determine whether Cryptosporidium oocysts were present in stools from captive snakes at Fundacao Parque Zoo logic (Zoological Park Foundation) in Sno Paulo, Brazil. Two collections were performed; the first in July 2008 and the second in February 2009. Fecal samples were collected from 74 enclosures that housed 101 individuals of 23 snake species. The stool specimens collected from 16 out of the 74 enclosures (21.6%) contained Cryptosporidium spp. oocysts; all of them were confirmed as Cryptosporidium serpent is, using molecular techniques. Only in three (18.7%) out of the 16 enclosures with positive samples were there animals with clinical signs compatible with infection by C. serpentis, such as regurgitation and significant progressive weight loss. From the results, it was concluded that diagnostic examinations need to be performed periodically, even on clinically healthy animals, as a preventive measure.
Resumo:
Considering the importance of neosporosis in the animal health and production, the frequency of antibodies to Neospora caninum was evaluated in dairy cattle of the Southwestern region of Mato Grosso State, Brazil, in addition to serum samples obtained from dogs and humans living in the farms. A total of 1036 serum samples were analyzed, from which 932 were from dairy bovine females, 37 from dogs and 67 from humans, from 24 farms and examined by the indirect fluorescent antibody test (IFAT). Reactive human scrum samples were retested by Western-blotting to confirm the results. Antibodies to N. caninum were found in 499 cattle sera (53.5 %), with at least one positive in each farm, 25 dog sera (67.6 %) and seven human sera (10.5 %). There was no significant difference in the number of positive cattle sera according to age group. The results indicate a wide dissemination of N caninum in the studied region.
Resumo:
Due to the scarcity of information related to the epidemiology of Cryptosporidium infection in passerine birds, this study aimed to determine the periodicity of fecal shedding of Cryptosporidium spp. oocysts, after natural infection, and its clinical signs, mortality, and molecular characterization. Four hundred eighty fecal samples were collected from 40 birds, including 372 samples from 31 adult birds and 108 samples from nine young birds (up to 12 months old), housed in five aviaries, monthly from September 2007 to September 2008, with the exception of April. The birds originated from aviaries in which the following species were raised: great-billed seed-finch (Oryzoborus maximiliani), lesser seed-finch (Oryzoborus angolensis), ultramarine grosbeak (Cyanocompsa brissonii), and rusty-collared seedeater (Sporophila collaris). The samples were preserved in 2.5% potassium dichromate at 4A degrees C until processing. The oocysts were purified by centrifugal flotation in Sheather`s solution, followed by genomic DNA extraction and molecular characterization of oocysts using the nested polymerase chain reaction for amplification of fragments of the 18S subunit of rRNA gene. Intermittent shedding of oocysts was observed by positive amplification for Cryptosporidium spp. in 91 (24.5%) samples of adult birds and 14 (13%) of young birds. The sequencing of the amplified fragments enabled the identification of Cryptosporidium galli. Although all the aviaries had birds positive for C. galli, morbidity or mortality was observed in only one aviary and was associated with concomitant infection with Escherichia coli and Isospora sp.
Resumo:
The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) irradiation on the removal of root surface smear layer of extracted human teeth and to compare its efficacy with that of citric acid, ethylenediamine tetra-acetic acid (EDTA), or a gel containing a mixture of tetracycline hydrochloride (HCl) and citric acid, using scanning electron microscopy (SEM). Thirty human dentin specimens were randomly divided into six groups: G1 (control group), irrigated with 10 ml of physiologic saline solution; G2, conditioned with 24% citric acid gel; G3, conditioned with 24% EDTA gel; G4, conditioned with a 50% citric acid and tetracycline gel; G5, irradiated with Er:YAG laser (47 mJ/10 Hz/5.8 J/cm(2)/pulse); G6, irradiated with Er:YAG laser (83 mJ/10 Hz/10.3 J/cm(2)/pulse). Electron micrographs were obtained and analyzed according to a rating system. Statistical analysis was conducted with Kruskal-Wallis and Mann-Whitney tests (P < 0.05). G1 was statistically different from all the other groups; no statistically significant differences were observed between the Er:YAG laser groups and those undergoing the other treatment modalities. When the two Er:YAG laser groups were compared, the fluency of G6 was statistically more effective in smear layer removal than the one used in G5 (Mann-Whitney test, P < 0.01). Root surfaces irradiated by Er:YAG laser had more irregular contours than those treated by chemical agents. It can be concluded that all treatment modalities were effective in smear layer removal. The results of our study suggest that the Er:YAG laser can be safely used to condition diseased root surfaces effectively. Furthermore, the effect of Er:YAG laser irradiation on root surfaces should be evaluated in vivo so that its potential to enhance the healing of periodontal tissues can be assessed.
Resumo:
Alternative treatment for recurrent labial infection by herpes simplex virus (HSV) have been considered. The aim of this study was to evaluate the effectiveness of laser phototherapy in prevention and reduction of severity of labial manifestations of herpes labialis virus. Seventy-one patients, divided into experimental (n = 41) and control (n = 30) groups were followed up for 16 months. Patients in the control group were treated topically with aciclovir and patients in the experimental group were subjected to laser phototherapy (one session per week, 10 weeks): 780 nm, 60 mW, 3.0 J/cm(2) or 4.5 J/cm(2) on healthy (no HSV-1 infection) and affected (with HSV-1 infection) tissues. Patients in the experimental group presented a significant decrease in dimension of herpes labialis lesions (P = 0.013) and inflammatory edema (P = 0.031). The reduction in pain level (P = 0.051) and monthly recurrences (P = 0.076) did not reach statistical significance. This study represents an in vivo indication that this treatment should be further considered as an effective alternative to therapeutic regimens for herpes labialis lesions.
Resumo:
The immunossuppression caused by HIV infection makes the affected individuals more susceptible to some diseases including infections, neoplasms, or even the association between them. Kaposi sarcoma (KS) is the most common AIDS-related neoplasm, featured as an angioproliferative disorder. Its cause seems to be related to the human herpesvirus type 8 and it is usually associated with lower CD4+ T cell count. Oral involvement is frequent, presenting red to blue-purplish plaques, maculaes, and nodules. On the other hand, paracoccidioidomycosis (PCM) is a systemic mycosis, endemic in Latin America, caused by Paracoccidioides brasiliensis. This mycosis is not commonly related to human immunodeficiency virus (HIV) infection, although PCM can be present in immunosuppression cases. Oral lesions, as granulomatous ulcers, are often identified in seropositive patients with PCM. A rare case, in which a male HIV-positive patient presented simultaneously Kaposi sarcoma and PCM in the same fragment of oral mucosa biopsy, is described. To the best of our knowledge, this concomitant association had not been previously described. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Neurofibroma is a benign peripheral nerve sheath tumor that can be occasionally found in the head and neck region as multiple lesions associated with neurofibromatosis type 1 (NF-1) or as a solitary tumor. The real frequency of isolated neurofibromas not associated with NF is uncertain, and lesions in the temporal region are extremely rare. The aim of the current article was to report an unusual case of solitary neurofibroma localized in the temporal and infratemporal regions with 10 years of evolution in a female patient without any other manifestation or familiar history of NF-1. The patient underwent surgical treatment for complete excision of the lesion, and the 2-year follow-up revealed no signs of recurrence.
Resumo:
Aims: The objective of this study was to compare the frequency of herpes simplex virus type 1 (HSV-1), Epstein-Barr virus (EBV) and human cytomegalovirus (HCMV) in subgingival plaque, saliva and peripheral blood of HIV-positive and-negative patients with periodontal disease. Materials and Methods: Fifty HIV-positive subjects (23 with gingivitis, 27 with periodontitis) and 50 healthy HIV-negative patients with chronic periodontitis were included in the study. Parameters of probing depth (PD), clinical attachment level (CAL), gingival index and plaque index were recorded. The samples were processed for viral identification by the nested polymerase chain reaction technique. Results: HCMV was the most prevalent virus in HIV-positive (82%) and-negative patients (84%), and the detection in the three samples was similar (p > 0.05). HSV-1 was the least prevalent virus in both groups, being detected in similar frequencies in oral sites and in peripheral blood. EBV-1 was found more frequently in saliva and subgingival plaque of HIV-positive patients than in HIV-negative patients (p <= 0.05). Conclusions: EBV-1 was more frequently recovered in oral sites of HIV-positive patients than in HIV-negative patients.
Resumo:
Purpose: To evaluate the influence of dentin moisture on bond strengths of an etch-and-rinse bonding agent to primary dentin clinically and in the laboratory. Methods: The sample consisted of two groups of 20 caries-free primary second molars: molars in exfoliation period (clinical group) and extracted molars (laboratory group). Class I cavities were prepared in all specimens leaving a flat dentin surface on the pulpal floor. A two-step etch-and-rinse adhesive was vigorously rubbed on either dry (n= 5) or wet demineralized dentin (n= 5) under clinical or laboratory conditions. After restorative procedures, the teeth from the clinical group were extracted after 20 minutes. All samples were processed and underwent microtensile bond strength test and silver nitrate uptake evaluation under scanning electron microscopy. Results: Statistically higher bond strength values were observed when the bonding was performed under laboratory conditions and on a wet demineralized dentin. Most of the failures were adhesive and mixed irrespective of the experimental condition. Silver nitrate uptake occurred in all groups irrespective of the experimental condition. Resin-dentin bond strengths produced in the laboratory in primary teeth may overestimate those produced under clinical circumstances. (Am J Dent 2011;24:221-225).
Resumo:
Objectives: The aim of this study was to test the effect of adhesive temperature on the bond strength to dentin (mu TBS) and silver nitrate uptake (SNU) of an ethanol/water (Adper Single Bond 2 [SB]) and an acetone-based (Prime&Bond 2.1 [PB]) etch-and-rinse adhesive system. Methods: The bottles of each adhesive were kept in various temperatures (5 degrees C, 20 degrees C, 37 degrees C and 50 degrees C) for 1 h previously to its application in the occlusal demineralized dentin of 40 molars. Bonded sticks (0.8 mm(2)) were tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6 M) of water storage. Two bonded sticks from each hemi-tooth were immersed in silver nitrate and analyzed by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results: No significant difference in mu TBS was detected for both adhesives at 5 degrees C and 20 degrees C. The highest bond strength for PB was observed in the 37 degrees C group while for SB it was in the 50 degrees C. Significant reductions of bond strengths were observed for PB at 37 degrees C and SB at 50 degrees C after 6 M of water storage. Silver nitrate deposition was seen in all hybrid layers, irrespective of the group. Lower silver nitrate deposition (water trees) in the adhesive layer was seen for PB and SB at higher temperatures. Conclusions: The heating or refrigeration of the adhesives did not improve their resin-dentin bond resistance to water degradation over time. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objectives. To examine the effect of prolonged application time on the early and 3-year resin-dentin microtensile bond strength. Methods. Water/ethanol (Single Bond [SB]) and acetone-based systems (One Step [OS]) were employed. A flat superficial dentin surface was exposed in third human molars by wet abrasion. The adhesives were applied to a delimited area of 52 mm(2) on wet surfaces, for 40, 90, 150 and 300s. Four teeth were assigned for each experimental condition. Composite build-ups were constructed incrementally After water storage at 37 degrees C for 24 h, teeth were sectioned to obtain sticks with cross-sectional areas of 0.8 mm(2) to be tested in tension (0.5 mm/min) either immediately (IM) or after 3 years (3Y) of water storage. The microtensile bond strength (mu TBS) values were analyzed by two way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results. The 90- and 150-s groups achieved the highest IM mu TBS for OS (p < 0.01). For SB, the highest IM mu TBS values were observed after 300-s application (p < 0.01). Significant decreases in mu TBS were observed for OS in the 40- and 90-s groups after 3Y, except for the 150-s group. With regard to SB, after 3Y significant drops in mu TBS values were observed for the 40- and 150-s groups, except for the 300-s group. Significance. Prolonged application times can increase the immediate LTBS of two-step etch-and-rinse adhesive systems and make the adhesive layer more stable over time. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives To characterize the properties of dentin matrix treated with two proanthocyanidin rich cross-linking agents and their effect on dentin bonded interfaces. Methods Sound human molars were cut into 0.5mm thick dentin slabs, demineralized and either treated with one of two cross-linking agents (grape seedGSE and cocoa seedCOE extracts) or left untreated. The modulus of elasticity of demineralized dentin was assessed after 10 or 60min and the swelling ratio after 60min treatment. Bacterial collagenase was also used to assess resistance to enzymatic degradation of samples subjected to ultimate tensile strength. The effect of GSE or COE on the resindentin bond strength was evaluated after 10 or 60min of exposure time. Data were statistically analyzed at a 95% confidence interval. Results Both cross-linkers increased the elastic modulus of demineralized dentin as exposure time increased. Swelling ratio was lower for treated samples when compared to control groups. No statistically significant changes to the UTS indicate that collagenase had no effect on dentin matrix treated with either GSE or COE. Resindentin bonds significantly increased following treatment with GSE regardless of the application time or adhesive system used. Significance Increased mechanical properties and stability of dentin matrix can be achieved by the use of PA-rich collagen cross-linkers most likely due to the formation of a PAcollagen complex. The short term resindentin bonds can be improved after 10min dentin treatment.(C) 2010 Academy of Denta lMaterials. Published by Elsevier Ltd. All rights reserved.
Resumo:
The aims of endodontic treatment in cases of apical periodontitis are to reduce as much as possible the number of microorganisms inside the root canal system and to inactivate toxins produced by them. Most of the times, these objectives are not achieved solely by chemomechanical preparation, and intracanal dressing may be necessary. In these cases, calcium hydroxide is used as a root canal dressing due to its well-known and recognized antimicrobial activity. Chlorhexidine has a wide spectrum of antimicrobial activity and its association with calcium hydroxide has been recommended in an attempt to amplify antimicrobial effects of calcium hydroxide. It is also known that dentin exerts a buffering effect under wide pH variations, and may be responsible for decreasing the antimicrobial activity of drugs inside the root canal. The objectives of this study were to assess the pH of 2% chlorhexidine gel and calcium hydroxide alone or in combination, as well as the influence of dentin on the pH of these compounds. Dentin powder was obtained from bovine teeth and added as 1.8% to the volume of the medications. All substances were individually stored in plastic flasks, in triplicate. A pH meter was used at five different moments to assess pH in viscous medium: immediately after preparation and after 24 h, and 7, 14, and 21 days. Results were analyzed by paired Student`s t-test. Statistically significant differences were observed in the 2% chlorhexidine gel group alone or associated with calcium hydroxide and added of dentin powder (P < 0.05). Mean pH values indicated the influence of dentin powder because of a significant increase in pH. Calcium hydroxide with propylene glycol as the vehicle always showed high pH, demonstrating that this compound was not affected by the presence of dentin.