905 resultados para Joint angles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel computerized algorithm for hip joint motion simulation and collision detection, called the Equidistant Method, has been developed. This was compared to three pre-existing methods having different properties regarding definition of the hip joint center and behavior after collision detection. It was proposed that the Equidistant Method would be most accurate in detecting the location and extent of femoroacetabular impingement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This pilot study defines the feasibility of cartilage assessment in symptomatic femoroacetabular impingement patients using intra-articular delayed gadolinium-enhanced MRI of cartilage (ia-dGEMRIC). Nine patients were scanned preliminary to study the contrast infiltration process into hip joint cartilage. Twenty-seven patients with symptomatic femoroacetabular impingement were subsequently scanned with intra-articular delayed gadolinium-enhanced MRI of cartilage. These T(1) findings were correlated to morphological findings. Zonal variations were studied. This pilot study demonstrates a significant difference between the pre- and postcontrast T(1) values (P < 0.001) remaining constant for 45 min. We noted higher mean T(1) values in morphologically normal-appearing cartilage than in damaged cartilage, which was statistically significant for all zones except the anterior-superior zone. Intraobserver (0.972) and interobserver correlation coefficients (0.933) were statistically significant. This study outlines the feasibility of intra-articular delayed gadolinium-enhanced MRI of cartilage for assessment of cartilage changes in patients with femoroacetabular impingement. It can also define the topographic extent and differing severities of cartilage damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate whether T1-mapping of hip joint with intra-articular delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (ia-dGEMRIC) is comparable to the already established intravenous (iv)-technique for assessing different grades of cartilage degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Total joint replacements represent a considerable part of day-to-day orthopaedic routine and a substantial proportion of patients undergoing unilateral total hip arthroplasty require a contralateral treatment after the first operation. This report compares complications and functional outcome of simultaneous versus early and delayed two-stage bilateral THA over a five-year follow-up period. Methods The study is a post hoc analysis of prospectively collected data in the framework of the European IDES hip registry. The database query resulted in 1819 patients with 5801 follow-ups treated with bilateral THA between 1965 and 2002. According to the timing of the two operations the sample was divided into three groups: I) 247 patients with simultaneous bilateral THA, II) 737 patients with two-stage bilateral THA within six months, III) 835 patients with two-stage bilateral THA between six months and five years. Results Whereas postoperative hip pain and flexion did not differ between the groups, the best walking capacity was observed in group I and the worst in group III. The rate of intraoperative complications in the first group was comparable to that of the second. The frequency of postoperative local and systemic complication in group I was the lowest of the three groups. The highest rate of complications was observed in group III. Conclusions From the point of view of possible intra- and postoperative complications, one-stage bilateral THA is equally safe or safer than two-stage interventions. Additionally, from an outcome perspective the one-stage procedure can be considered to be advantageous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tendon transfers and calcaneal osteotomies are commonly used to treat symptoms related to medial ankle arthrosis in fixed pes cavovarus. However, the relative effect of these osteotomies in terms of lateralizing the ground contact point of the hindfoot and redistributing ankle joint contact stresses are unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Osteoarthritis is the most common form of joint disorder and a leading cause of pain and physical disability. Observational studies suggested a benefit for joint lavage, but recent, sham-controlled trials yielded conflicting results, suggesting joint lavage not to be effective. Objectives To compare joint lavage with sham intervention, placebo or non-intervention control in terms of effects on pain, function and safety outcomes in patients with knee osteoarthritis. Search methods We searched CENTRAL, MEDLINE, EMBASE, and CINAHL up to 3 August 2009, checked conference proceedings, reference lists, and contacted authors. Selection criteria We included studies if they were randomised or quasi-randomised trials that compared arthroscopic and non-arthroscopic joint lavage with a control intervention in patients with osteoarthritis of the knee. We did not apply any language restrictions. Data collection and analysis Two independent review authors extracted data using standardised forms. We contacted investigators to obtain missing outcome information. We calculated standardised mean differences (SMDs) for pain and function, and risk ratios for safety outcomes. We combined trials using inverse-variance random-effects meta-analysis. Main results We included seven trials with 567 patients. Three trials examined arthroscopic joint lavage, two non-arthroscopic joint lavage and two tidal irrigation. The methodological quality and the quality of reporting was poor and we identified a moderate to large degree of heterogeneity among the trials (I2 = 65%). We found little evidence for a benefit of joint lavage in terms of pain relief at three months (SMD -0.11, 95% CI -0.42 to 0.21), corresponding to a difference in pain scores between joint lavage and control of 0.3 cm on a 10-cm visual analogue scale (VAS). Results for improvement in function at three months were similar (SMD -0.10, 95% CI -0.30 to 0.11), corresponding to a difference in function scores between joint lavage and control of 0.2 cm on a WOMAC disability sub-scale from 0 to 10. For pain, estimates of effect sizes varied to some degree depending on the type of lavage, but this variation was likely to be explained by differences in the credibility of control interventions: trials using sham interventions to closely mimic the process of joint lavage showed a null-effect. Reporting on adverse events and drop out rates was unsatisfactory, and we were unable to draw conclusions for these secondary outcomes. Authors' conclusions Joint lavage does not result in a relevant benefit for patients with knee osteoarthritis in terms of pain relief or improvement of function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the modern joint protection (JP) concept for people with rheumatoid arthritis (RA) is an active coping strategy to improve daily tasks and role performance by changing working methods and using assistive devices. Effective group JP education includes psycho-educational interventions. The Pictorial Representation of Illness and Self Measure (PRISM) is an interactive hands-on-tool, assessing (a) the individual's perceived burden of illness and (b) relevant individual resources. Both issues are important for intrinsic motivation to take action and change behaviour. This study compared individual conventional JP education (C-JP) with PRISM-based JP education (PRISM-JP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnostic yield of prosthetic joint-associated infection is hampered by the phenotypic change of bacteria into a sessile and resistant form, also called biofilm. With sonication, adherent bacteria can be dislodged from the prosthesis. Species identification may be difficult because of their variations in phenotypic appearance and biochemical reaction. We have studied the phenotypic, genotypic, and biochemical properties of Escherichia coli variants isolated from a periprosthetic joint infection. The strains were collected from synovial fluid, periprosthetic tissue, and fluid from the explanted and sonicated prosthesis. Isolates from synovial fluid revealed a normal phenotype, whereas a few variants from periprosthetic tissue and all isolates from sonication fluid showed different morphological features (including small-colony variants). All isolates from sonication fluid were beta-galactosidase negative and nonmotile; most were indole negative. Because of further variations in biochemical properties, species identification was false or not possible in 50% of the isolates included in this study. In contrast to normal phenotypes, variants were resistant to aminoglycosides. Typing of the isolates using pulsed-field gel electrophoresis yielded nonidentical banding patterns, but all strains were assigned to the same clonal origin when compared with 207 unrelated E. coli isolates. The bacteria were repeatedly passaged on culture media and reanalyzed. Thereafter, most variants reverted to normal phenotype and regained their motility and certain biochemical properties. In addition, some variants displayed aminoglycoside susceptibility after reversion. Sonication of an explanted prosthesis allows insight into the lifestyle of bacteria in biofilms. Since sonication fluid also reveals dislodged sessile forms, species identification of such variants may be misleading.