959 resultados para Intermittent catheter
Resumo:
pH monitoring has been used as a diagnostic tool in gastro-oesophageal reflux disease (GERD) for many years. Recent studies have shown that wireless capsule pH monitoring is better tolerated and interferes less with daily activities as compared to traditional catheter-based pH monitoring. Moreover, prolonged recording time (48 h instead of 24 h) is possible with wireless pH monitoring. The main secondary effect of wireless capsule pH monitoring is induction of thoracic discomfort in 10-65% of the patients, which can vary from mild foreign body sensation to severe chest pain. Sensitivity and specificity of wireless capsule monitoring is comparable to that of traditional pH monitoring. It has not been proven yet that better tolerability and a longer recording time increases the diagnostic yield of wireless capsule monitoring in GERD.
Resumo:
Este trabajo presenta un Algoritmo Genético (GA) del problema de secuenciar unidades en una línea de producción. Se tiene en cuenta la posibilidad de cambiar la secuencia de piezas mediante estaciones con acceso a un almacén intermedio o centralizado. El acceso al almacén además está restringido, debido al tamaño de las piezas.AbstractThis paper presents a Genetic Algorithm (GA) for the problem of sequencing in a mixed model non-permutation flowshop. Resequencingis permitted where stations have access to intermittent or centralized resequencing buffers. The access to a buffer is restricted by the number of available buffer places and the physical size of the products.
Resumo:
A 38-year-old woman presented with blurred vision and "jumping" of the right eye for 7 months. Magnetic resonance imaging of the head was normal. Intermittent intorsion of the right eye was noted on examination, consistent with superior oblique myokymia. She was initially treated with carbamazepine but stopped after becoming light-headed. The diagnosis and treatment of superior oblique myokymia are discussed.
Resumo:
Introduction : La leucocorie ou le reflet pupillaire blanchâtre traduit la réflexion de la lumière dans l'aire pupillaire d'une lésion intraoculaire lors de l'éclairage du fond d'oeil. Elle peut prendre des colorations diverses, blanche, jaune, grise, selon la nature de la maladie, présenter un caractère intermittent et fugitif dépendant de l'éclairage, de l'angle d'observation, de la localisation et de la taille de la lésion. La leucocorie est la première manifestation de nombreuses affections oculaires dont le rétinoblastome, tumeur maligne de la rétine, constitue l'atteinte la plus grave parce qu'elle peut mettre en péril non seulement la vue mais aussi la vie de l'enfant. Les autres maladies en cause sont dans l'ordre de fréquence la maladie de Coats, la persistance et hyperplasie du vitré primitif, les maladies inflammatoires (uvéites, toxoplasmose, toxocarose oculaire,...), la rétinopathie du prématuré, les malformations oculaires (fibres à myéline, colobomes, plis falciformes,...), la cataracte, l'hémorragie vitréenne et le décollement de rétine. Objectif : Le but de ce travail est d'analyser les maladies oculaires de l'enfant qui se manifestent par une leucocorie comme signe d'appel et d'étudier leur fréquence relative. Méthode: Il s'agit d'une étude rétrospective de 1037 enfants consécutifs examinés à l'unité d'oncopédiatrie de l'Hôpital Ophtalmique de Lausanne du 1er janvier 1980 au 31 décembre 2010 pour une affection oculaire. Les diagnostics des patients ayant présenté une leucocorie comme signe ont été collectés. En complément, l'âge au premier symptôme, l'âge au diagnostic, le genre, l'hérédité et la latéralité ont été pris en compte selon la nature de la lésion et la documentation disponible. Résultats : Sur 1037 patients, nous avons dénombré 537 cas de rétinoblastome (52%), 281 cas de malformations congénitales (27%), 169 cas de maladies vasculaires (16%). Parmi les affections s'étant manifestées par une leucocorie, le rétinoblastome arrive en première place (315 cas sur 537) (59%), puis viennent la maladie de Coats (21 cas sur 67) (31%), la cataracte (17 cas sur 68) (25%) et la persistance et hyperplasie du vitré primitif (16 cas sur 66) (24%). Conclusion : La connaissance des caractéristiques de la leucocorie chez l'enfant et la prise de conscience de son importance diagnostique sont essentielles dans le dépistage précoce d'affections rétiniennes qui peuvent avoir des répercussions non seulement sur la fonction visuelle mais aussi sur le pronostic vital.
Resumo:
BACKGROUND: Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS: In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS: The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS: Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones.
Resumo:
Työn tarkoituksena oli kehittää jatkuvatoimiseen pesuun soveltuva emäksinen ja hapan huovanpesuaine sekä tutkia huovanpesun parametreja laboratoriossa ja paperikoneella. Kirjallisuusosassa tarkasteltiin paperikoneen puristinosaa, puristinhuopien ominaisuuksia, puristinhuovissa esiintyviä saostumia ja puristinhuopien kunnostusta sekä esiteltiin FeltPerm-vedenläpäisykykymittari. Kokeellisessa osassa analysoitiin käytetty huopa kvalitatiivisesti ja kvantitatiivisesti ja kun huopaa tukkivien yhdisteiden kemiallinen luonne oli selvitetty, kehitettiin käynninaikaiseen pesuun soveltuva emäksinen ja hapan huovanpesuaine. Huovanpesuaineiden kehitystyössä pesuaineiden tehokkuutta tutkittiin kolmella eri menetelmällä, joista kaksi perustui huovan massan muutoksen määrittämiseen pesussa ja yksi huovan vedenläpäisykyvyn mittaamiseen. Kehitetyillä pesuaineilla optimoitiin laboratoriossa happo- ja emäspesun pH sekä vaikutusaika. Lisäksi tutkittiin huovan turpoamista emäspesussa ja lämpötilan vaikutusta pesutulokseen. Puristinhuopien vedenläpäisykykyä tutkittiin FeltPerm-laitteella kahdella eri SC-paperikoneella, joista toisella oli käytössä käynninaikainen jaksottainen pesu ja toisella pelkät seisokkipesut. Koneella, jossa huovat pestiin käynninaikaisesti, määritettiin pesuparametreja ja optimoitiin emäsvaiheen aikainen pH. Kehitetyillä pesuaineilla suoritettiin koeajo tehtaalla.
Resumo:
We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.
Resumo:
OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.
Resumo:
This work concerns the experimental study of rapid granular shear flows in annular Couette geometry. The flow is induced by continuous driving of the horizontal plate at the top of the granular bed in an annulus. The compressive pressure, driving torque, instantaneous bed height and rotational speed of the shearing plate are measured. Moreover, local stress fluctuations are measured in a medium made of steel spheres 2 and 3 mm in diameter. Both monodisperse packing and bidisperse packing are investigated to reveal the influence of size diversity in intermittent features of granular materials. Experiments are conducted in an annulus that can contain up to 15 kg of spherical steel balls. The shearing granular medium takes place via the rotation of the upper plate which compresses the material loaded inside the annulus. Fluctuations of compressive force are locally measured at the bottom of the annulus using a piezoelectric sensor. Rapid shear flow experiments are pursued at different compressive forces and shear rates and the sensitivity of fluctuations are then investigated by different means through monodisperse and bidisperse packings. Another important feature of rapid granular shear flows is the formation of ordered structures upon shearing. It requires a certain range for the amount of granular material (uniform size distribution) loaded in the system in order to obtain stable flows. This is studied more deeply in this thesis. The results of the current work bring some new insights into deformation dynamics and intermittency in rapid granular shear flows. The experimental apparatus is modified in comparison to earlier investigations. The measurements produce data for various quantities continuously sampled from the start of shearing to the end. Static failure and dynamic shearing ofa granular medium is investigated. The results of this work revealed some important features of failure dynamics and structure formation in the system. Furthermore, some computer simulations are performed in a 2D annulus to examine the nature of kinetic energy dissipation. It is found that turbulent flow models can statistically represent rapid granular flows with high accuracy. In addition to academic outcomes and scientific publications our results have a number of technological applications associated with grinding, mining and massive grain storages.
Resumo:
En Riegel v. Medtronic Inc. (552 U.S.__2008; February 20, 2008), el Sr. Riegel tuvo que ser sometido a un by-pass como consecuencia de la rotura del catéter, fabricado por Medtronic, con el que su médico le practicaba una angioplastia. A pesar de que el catéter había obtenido la autorización de comercialización de la FDA y cumplía los requisitos de seguridad previstos por el sistema regulatorio federal, el Sr. Riegel y su mujer interpusieron una acción de daños contra Medtronic –y no contra el médico- conforme a las reglas de responsabilidad civil objetiva y por negligencia del Common Law neoyorquino. Sin embargo, el Tribunal Supremo federal de los EE.UU., en ponencia del Magistrado Antonin Gregory Scalia, votó, por mayoría de ocho magistrados, rechazar el recurso de la Sra. Riegel y confirmar la sentencia de segunda instancia, desestimatoria de la demanda, porque consideró que la regla de primacía del derecho regulatorio federal sobre seguridad de productos sanitarios [Medical Device Amendments de 1976, 21 U.S.C. Artículo 360k(a)] excluye la aplicabilidad no sólo del derecho regulatorio estatal sobre seguridad de productos sanitarios, sino también del Common Law sobre responsabilidad civil del fabricante.
Resumo:
The EAUN Guidelines Working Group for indwelling catheters have prepared this guideline document to help nurses assess the evidence-based management of catheter care and to incorporate the guidelines’ recommendations into their clinical practice. These guidelines are not meant to be proscriptive, nor will adherence to these guidelines guarantee a successful outcome in all cases. Ultimately, decisions regarding care must be made on a case-by-case basis by healthcare professionals after consultation with their patients using their clinical judgement, knowledge and expertise.
Resumo:
Severe acute refractory respiratory failure is considered a life-threatening situation, with a high mortality of 40 to 60%. When conservative oxygenation methods fail, a lifesaving measure is the introduction of extracorporeal membrane oxygenation (ECMO). Venovenous ECMO (VV-ECMO) is a preferred modality of support for patients with refractory acute respiratory failure. Specifically, bicaval VV-ECMO is a well-recognized and validated therapy, where single or double periphery venous access is used for the insertion of two differently sized cannulas in order to achieve adequate blood oxygenation. Compared to venoarterial ECMO, in VV-ECMO, the rate of complications, such as thrombosis, bleeding, infection and ischemic events, is lower. On the other hand, the size and insertion location is an obstacle to patient mobilization. This is a considerable problem for patients where the time interval for lung recovery and the bridge to the transplantation is prolonged. To address this issue, a dual-lumen, single venovenous cannula was introduced. Here, by insertion of one single catheter in one target vessel, in a majority of cases in the right internal jugular vein, satisfactory oxygenation of the patient is achieved. In this form, the instituted VV-ECMO enables patient mobility, better physical rehabilitation and facilitates pulmonary extubation and toilet. However, relatively early, after the first short-term reports were published, a relatively high complication rate became evident. In the recent literature, the complication rate using actual commercially available double-lumen venovenous cannula ranges between 5 and 30%. These cases were mostly conjoined to the implantation phase or the early postoperative phase and vary between right heart perforation to migration of the cannula. This review focuses on complications allied to commercially available dual-lumen, single, venovenous cannula implantation, pointing out the critical segments of the implantation process and analyzing the structure of the device.
Resumo:
PURPOSE: (1) To assess the outcomes of minimally invasive simple prostatectomy (MISP) for the treatment of symptomatic benign prostatic hyperplasia in men with large prostates and (2) to compare them with open simple prostatectomy (OSP). METHODS: A systematic review of outcomes of MISP for benign prostatic hyperplasia with meta-analysis was conducted. The article selection process was conducted according to the PRISMA guidelines. RESULTS: Twenty-seven observational studies with 764 patients were analyzed. The mean prostate volume was 113.5 ml (95 % CI 106-121). The mean increase in Qmax was 14.3 ml/s (95 % CI 13.1-15.6), and the mean improvement in IPSS was 17.2 (95 % CI 15.2-19.2). Mean duration of operation was 141 min (95 % CI 124-159), and the mean intraoperative blood loss was 284 ml (95 % CI 243-325). One hundred and four patients (13.6 %) developed a surgical complication. In comparative studies, length of hospital stay (WMD -1.6 days, p = 0.02), length of catheter use (WMD -1.3 days, p = 0.04) and estimated blood loss (WMD -187 ml, p = 0.015) were significantly lower in the MISP group, while the duration of operation was longer than in OSP (WMD 37.8 min, p < 0.0001). There were no differences in improvements in Qmax, IPSS and perioperative complications between both procedures. The small study sizes, publication bias, lack of systematic complication reporting and short follow-up are limitations. CONCLUSIONS: MISP seems an effective and safe treatment option. It provides similar improvements in Qmax and IPSS as OSP. Despite taking longer, it results in less blood loss and shorter hospital stay. Prospective randomized studies comparing OSP, MISP and laser enucleation are needed to define the standard surgical treatment for large prostates.
Resumo:
OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.