925 resultados para Interface auditiva


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerclages regain interest due to a rising number of periprosthetic fractures. The contact distribution at the circumferential cerclage-bone interface is still unknown. Local interface pressure depends on the amount of contact area. Cortical damage at the interface would provoke cerclage loosening. Therefore, the contact area, the bone pressure along the interface and the cortical resistance underneath loaded cerclages were determined in an ex vivo model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clay minerals have a fundamental importance in many processes in soils and sediments such as the bioavailability of nutrients, water retention, the adsorption of common pollutants, and the formation of an impermeable barrier upon swelling. Many of the properties of clay minerals are due to the unique environment present at the clay mineral/water interface. Traditional techniques such as X-ray diffraction (XRD) and absorption isotherms have provided a wealth of information about this interface but have suffered from limitations. The methods and results presented herein are designed to yield new experimental information about the clay mineral/water interface.A new method of studying the swelling dynamics of clay minerals was developed using in situ atomic force microscopy (AFM). The preliminary results presented here demonstrate that this technique allows one to study individual clay mineral unit layers, explore the natural heterogeneities of samples, and monitor swelling dynamics of clay minerals in real time. Cation exchange experiments were conducted monitoring the swelling change of individual nontronite quasi-crystals as the chemical composition of the surrounding environment was manipulated several times. A proof of concept study has shown that the changes in swelling are from the exchange of interlayer cations and not from the mechanical force of replacing the solution in the fluid cell. A series of attenuated total internal reflection Fourier transform infrared spectroscopy (ATR-FTIR) experiments were performed to gain a better understanding of the organization of water within the interlayer region of two Fe-bearing clay minerals. These experiments made use of the Subtractive Kramers-Kronig (SKK) Transform and the calculation of difference spectra to obtain information about interfacial water hidden within the absorption bands of bulk water. The results indicate that the reduction of structural iron disrupts the organization of water around a strongly hydrated cation such as sodium as the cation transitions from an outer-sphere complex with the mineral surface to an inner-sphere complex. In the case of a less strongly hydrated cation such as potassium, reduction of structural iron actually increases the ordering of water molecules at the mineral surface. These effects were only noticed with the reduction of iron in the tetrahedral sheet close to the basal surface where the increased charge density is localized closer to the cations in the interlayer.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An implant-abutment interface at the alveolar bone crest is associated with sustained peri-implant inflammation; however, whether magnitude of inflammation is proportionally dependent upon interface position remains unknown. This study compared the distribution and density of inflammatory cells surrounding implants with a supracrestal, crestal, or subcrestal implant-abutment interface. All implants developed a similar pattern of peri-implant inflammation: neutrophilic polymorphonuclear leukocytes (neutrophils) maximally accumulated at or immediately coronal to the interface. However, peri-implant neutrophil accrual increased progressively as the implant-abutment interface depth increased, i.e., subcrestal interfaces promoted a significantly greater maximum density of neutrophils than did supracrestal interfaces (10,512 +/- 691 vs. 2398 +/- 1077 neutrophils/mm(2)). Moreover, inflammatory cell accumulation below the original bone crest was significantly correlated with bone loss. Thus, the implant-abutment interface dictates the intensity and location of peri-implant inflammatory cell accumulation, a potential contributing component in the extent of implant-associated alveolar bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this paper was to review the clinical literature on the Resonance frequency analysis (RFA) and Periotest techniques in order to assess the validity and prognostic value of each technique to detect implants at risk for failure. Material and methods: A search was made using the PubMed database to find clinical studies using the RFA and/or Periotest techniques. Results: A limited number of clinical reports were found. No randomized-controlled clinical trials or prospective cohort studies could be found for validity testing of the techniques. Consequently, only a narrative review was prepared to cover general aspects of the techniques, factors influencing measurements and the clinical relevance of the techniques. Conclusions: Factors such as bone density, upper or lower jaw, abutment length and supracrestal implant length seem to influence both RFA and Periotest measurements. Data suggest that high RFA and low Periotest values indicate successfully integrated implants and that low/decreasing RFA and high/increasing Periotest values may be signs of ongoing disintegration and/or marginal bone loss. However, single readings using any of the techniques are of limited clinical value. The prognostic value of the RFA and Periotest techniques in predicting loss of implant stability has yet to be established in prospective clinical studies. To cite this article: Aparicio C, Lang N P, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin. Oral Imp. Res., 17 (Suppl. 2), 2006; 2-7.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this article was to assess whether matrix metalloproteinase-13 (MMP-13) is produced by cells of the peri-implant interface tissues and to further characterize these cells. Tissue specimens were collected from the bone-prosthesis interface at the time of revision surgery of clinically loosened hip and knee arthroplasties (n = 27). Synovial tissues from osteoarthritic patients and young patients with mild joint deformity were used as controls (n = 6). Tissue samples were fixed in 4% PFA, decalcified with EDTA, and embedded in paraffin. Sections (4 microm) were stained with hematoxylin/eosin and for the osteoclastic marker enzyme tartrate resistant acid phosphatase. Monocytes/macrophages were characterized with a monoclonal antibody against CD68 and mRNAs encoding MMP-13 and alpha(1) collagen I (COL1A1) were detected by in situ hybridization. Cells expressing transcripts encoding MMP-13 were found in 70% of the interface tissues. These cells colocalized with a cell population expressing COL1A1 mRNA, and were fibroblastic in appearance. MMP-13 expressing cells were found in the close vicinity of osteoclasts and multinuclear giant cells. No signals for transcripts encoding MMP-13 were detected in multinuclear giant cells or in osteoclasts. Control tissues were negative for transcripts encoding MMP-13 mRNA. Fibroblasts of the interface from aseptically loosened endoprostheses selectively express MMP-13. By the expression and the release of MMP-13, these fibroblastic cells may contribute to the local degradation of the extracellular matrix and to bone resorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The area of microfluidics has increased in popularity with such fields as MEMS, microreactors, microscaleheat exchangers, etc. A comprehensive understanding of dissipation mechanisms for fluid flow in microchannels is required to accurately predict the behavior in these small systems. Tests were performed using a constant pressure potential created by two immiscible fluids juxtaposed in a microchannel. This study focused on the flow and dissipation mechanisms in round and square microchannels. There are four major dissipation mechanisms in slug flow; wall shear, dissipation at the contact line, menisci interaction and the stretching of the interface. A force balance between the internal driving potential, viscous drag and interface stretching was used to develop a model for the prediction of the velocity of a bislug in a microchannel. Interface stretching is a dissipation mechanism that has been included due to the unique system properties and becomes increasingly more important as the bislug decreases in length.