915 resultados para Illinois. Attorney Registration and Disciplinary Commission.
Resumo:
BACKGROUND: This study is based on a comprehensive survey of the neuropsychological attention-deficit hyperactivity disorder (ADHD) literature and presents the first psychometric analyses of different parameters of intra-subject variability (ISV) in patients with ADHD compared to healthy controls, using the Continuous Performance Test, a Go-NoGo task, a Stop Signal Task, as well as N-back tasks. METHODS: Data of 57 patients with ADHD and 53 age- and gender-matched controls were available for statistical analysis. Different parameters were used to describe central tendency (arithmetic mean, median), dispersion (standard deviation, coefficient of variation, consecutive variance), and shape (skewness, excess) of reaction time distributions, as well as errors (commissions and omissions). RESULTS: Group comparisons revealed by far the strongest effect sizes for measures of dispersion, followed by measures of central tendency, and by commission errors. Statistical control of ISV reduced group differences in the other measures substantially. One (patients) or two (controls) principal components explained up to 67% of the inter-individual differences in intra-individual variability. CONCLUSIONS: Results suggest that, across a variety of neuropsychological tests, measures of ISV contribute best to group discrimination, with limited incremental validity of measures of central tendency and errors. Furthermore, increased ISV might be a unitary construct in ADHD.
Resumo:
BACKGROUND: In this paper, we present a new method for the calibration of a microscope and its registration using an active optical tracker. METHODS: Practically, both operations are done simultaneously by moving an active optical marker within the field of view of the two devices. The IR LEDs composing the marker are first segmented from the microscope images. By knowing their corresponding three-dimensional (3D) position in the optical tracker reference system, it is possible to find the transformation matrix between the referential of the two devices. Registration and calibration parameters can be extracted directly from that transformation. In addition, since the zoom and focus can be modified by the surgeon during the operation, we propose a spline based method to update the camera model to the new setup. RESULTS: The proposed technique is currently being used in an augmented reality system for image-guided surgery in the fields of ear, nose and throat (ENT) and craniomaxillofacial surgeries. CONCLUSIONS: The results have proved to be accurate and the technique is a fast, dynamic and reliable way to calibrate and register the two devices in an OR environment.
Resumo:
OBJECTIVES: To evaluate the feasibility of fusion imaging compound tomography (FICT) of CT/MRI and single photon emission tomography (SPECT) versus planar scintigraphy only (plSc) in pre-surgical staging for vulvar cancer. MATERIALS AND METHODS: Analysis of consecutive patients with vulvar cancer who preoperatively underwent sentinel scintigraphy (planar and 3D-SPECT imaging) and CT or MRI. Body markers were used for exact anatomical co-registration and fusion datasets were reconstructed using SPECT and CT/MRI. The number and localisation of all intraoperatively identified and resected sentinel lymph nodes (SLN) were compared between planar and 3D fusion imaging. RESULTS: Twenty six SLN were localized on planar scintigraphy. Twelve additional SLN were identified after SPECT and CT/MRI reconstruction, all of them were confirmed intraoperatively. In seven cases where single foci were identified at plSc, fusion imaging revealed grouped individual nodes and five additional localisations were discovered at fusion imaging. In seven patients both methods identified SLN contra lateral to the primary tumor site, but only fusion imaging allowed to localise iliac SLN in four patients. All SLN predicted on fusion imaging could be localised and resected during surgery. CONCLUSIONS: Fusion imaging using SPECT and CT/MRI can detect SLN in vulvar cancer more precisely than planar imaging regarding number and anatomical localisation. FICT revealed additional information in seven out of ten cases (70%).
Resumo:
In this issue...Fish and Game Commission, Peace Corps, Great Falls Brewery, George D. McDonald, Glee club, Intramural basketball, Sugar Bowl, Metals Bank
Resumo:
OBJECTIVES A widespread assessment of the reporting of RCT abstracts published in dental journals is lacking. Our aim was to investigate the quality of reporting of abstracts published in leading dental specialty journals using, as a guide, the CONSORT for abstracts checklist. METHODS Electronic and supplementary hand searching were undertaken to identify RCTs published in seven dental specialty journals. The quality of abstract reporting was evaluated using a modified checklist based on the CONSORT for abstracts checklist. Descriptive statistics followed by univariate and multivariate analyses were conducted. RESULTS 228 RCT abstracts were identified. Reporting of interventions, objectives and conclusions within abstracts were adequate. Inadequately reported items included: title, participants, outcomes, random number generation, numbers randomized and effect size estimate. Randomization restrictions, allocation concealment, blinding, numbers analyzed, confidence intervals, intention-to-treat analysis, harms, registration and funding were rarely described. CONCLUSIONS The mean overall reporting quality score was suboptimal at 62.5% (95% CI: 61.9, 63.0). Significantly better abstract reporting was noted in certain specialty journals and in multicenter trials.
Resumo:
This paper presents a firsthand comparative evaluation of three different existing methods for selecting a suitable allograft from a bone storage bank. The three examined methods are manual selection, automatic volume-based registration, and automatic surface-based registration. Although the methods were originally published for different bones, they were adapted to be systematically applied on the same data set of hemi-pelvises. A thorough experiment was designed and applied in order to highlight the advantages and disadvantages of each method. The methods were applied on the whole pelvis and on smaller fragments, thus producing a realistic set of clinical scenarios. Clinically relevant criteria are used for the assessment such as surface distances and the quality of the junctions between the donor and the receptor. The obtained results showed that both automatic methods outperform the manual counterpart. Additional advantages of the surface-based method are in the lower computational time requirements and the greater contact surfaces where the donor meets the recipient.
Resumo:
Objective In order to benefit from the obvious advantages of minimally invasive liver surgery there is a need to develop high precision tools for intraoperative anatomical orientation, navigation and safety control. In a pilot study we adapted a newly developed system for computer-assisted liver surgery (CALS) in terms of accuracy and technical feasibility to the specific requirements of laparoscopy. Here, we present practical aspects related to laparoscopic computer assisted liver surgery (LCALS). Methods Our video relates to a patient presenting with 3 colorectal liver metastases in Seg. II, III and IVa who was selected in an appropriate oncological setting for LCALS using the CAScination system combined with 3D MEVIS reconstruction. After minimal laparoscopic mobilization of the liver, a 4- landmark registration method was applied to enable navigation. Placement of microwave needles was performed using the targeting module of the navigation system and correct needle positioning was confirmed by intraoperative sonography. Ablation of each lesion was carried out by application of microwave energy at 100 Watts for 1 minute. Results To acquire an accurate (less 0.5 cm) registration, 4 registration cycles were necessary. In total, seven minutes were required to accomplish precise registration. Successful ablation with complete response in all treated areas was assessed by intraoperative sonography and confirmed by postoperative CT scan. Conclusions This teaching video demonstrates the theoretical and practical key points of LCALS with a special emphasis on preoperative planning, intraoperative registration and accuracy testing by laparoscopic methodology. In contrast to mere ultrasound-guided ablation of liver lesions, LCALS offers a more dimensional targeting and higher safety control. This is currently also in routine use to treat vanishing lesions and other difficult to target focal lesions within the liver.
Resumo:
New ice-velocity measurements are obtained for the main trunk of Byrd Glacier, East Antarctica, using recently acquired Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) imagery. The velocities are derived from the application of a cross-correlation technique to sequential images acquired in 2000 and 2001. Images were co-registered and ortho-rectified with the aid of a digital elevation model (DEM) generated from ASTER stereo imagery. This paper outlines the process of DEM generation, image co-registration and correction, and the application of the cross-correlation technique to obtain ice velocities. Comparison of the new velocity map with earlier measurements of velocity from 1978 indicates that the glacier has undergone a substantial deceleration between observations. Portions of the glacier flowing at speeds of similar to 850 m a(-1) in 1978/79 were flowing at similar to 650 m a(-1) in 2000/01. The cause of this change in ice dynamics is not known, but the observation shows that East Antarctic outlet glaciers can undergo substantial changes on relatively short timescales.
Resumo:
CMOS-sensors, or in general Active Pixel Sensors (APS), are rapidly replacing CCDs in the consumer camera market. Due to significant technological advances during the past years these devices start to compete with CCDs also for demanding scientific imaging applications, in particular in the astronomy community. CMOS detectors offer a series of inherent advantages compared to CCDs, due to the structure of their basic pixel cells, which each contains their own amplifier and readout electronics. The most prominent advantages for space object observations are the extremely fast and flexible readout capabilities, feasibility for electronic shuttering and precise epoch registration,and the potential to perform image processing operations on-chip and in real-time. Here, the major challenges and design drivers for ground-based and space-based optical observation strategies for objects in Earth orbit have been analyzed. CMOS detector characteristics were critically evaluated and compared with the established CCD technology, especially with respect to the above mentioned observations. Finally, we simulated several observation scenarios for ground- and space-based sensor by assuming different observation and sensor properties. We will introduce the analyzed end-to-end simulations of the ground- and spacebased strategies in order to investigate the orbit determination accuracy and its sensitivity which may result from different values for the frame-rate, pixel scale, astrometric and epoch registration accuracies. Two cases were simulated, a survey assuming a ground-based sensor to observe objects in LEO for surveillance applications, and a statistical survey with a space-based sensor orbiting in LEO observing small-size debris in LEO. The ground-based LEO survey uses a dynamical fence close to the Earth shadow a few hours after sunset. For the space-based scenario a sensor in a sun-synchronous LEO orbit, always pointing in the anti-sun direction to achieve optimum illumination conditions for small LEO debris was simulated.
Resumo:
Purpose To this day, the slit lamp remains the first tool used by an ophthalmologist to examine patient eyes. Imaging of the retina poses, however, a variety of problems, namely a shallow depth of focus, reflections from the optical system, a small field of view and non-uniform illumination. For ophthalmologists, the use of slit lamp images for documentation and analysis purposes, however, remains extremely challenging due to large image artifacts. For this reason, we propose an automatic retinal slit lamp video mosaicking, which enlarges the field of view and reduces amount of noise and reflections, thus enhancing image quality. Methods Our method is composed of three parts: (i) viable content segmentation, (ii) global registration and (iii) image blending. Frame content is segmented using gradient boosting with custom pixel-wise features. Speeded-up robust features are used for finding pair-wise translations between frames with robust random sample consensus estimation and graph-based simultaneous localization and mapping for global bundle adjustment. Foreground-aware blending based on feathering merges video frames into comprehensive mosaics. Results Foreground is segmented successfully with an area under the curve of the receiver operating characteristic curve of 0.9557. Mosaicking results and state-of-the-art methods were compared and rated by ophthalmologists showing a strong preference for a large field of view provided by our method. Conclusions The proposed method for global registration of retinal slit lamp images of the retina into comprehensive mosaics improves over state-of-the-art methods and is preferred qualitatively.
Resumo:
In November 2010, nearly 110,000 people in the United States were waiting for organs for transplantation. Despite the fact that the organ donor registration rate has doubled in the last year, Texas has the lowest registration rate in the nation. Due to the need for improved registration rates in Texas, this practice-based culminating experience was to write an application for federal funding for the central Texas organ procurement organization, Texas Organ Sharing Alliance. The culminating experience has two levels of significance for public health – (1) to engage in an activity to promote organ donation registration, and (2) to provide professional experience in grant writing. ^ The process began with a literature review. The review was to identify successful intervention activities in motivating organ donation registration that could be used in intervention design for the grant application. Conclusions derived from the literature review included (1) the need to specifically encourage family discussions, (2) religious and community leaders can be leveraged to facilitate organ donation conversations in families, (3) communication content must be culturally sensitive and (4) ethnic disparities in transplantation must be acknowledged and discussed.^ Post the literature review; the experience followed a five step process of developing the grant application. The steps included securing permission to proceed, assembling a project team, creation of a project plan and timeline, writing each element of the grant application including the design of proposed intervention activities, and completion of the federal grant application. ^ After the grant application was written, an evaluation of the grant writing process was conducted. Opportunities for improvement were identified. The first opportunity was the need for better timeline management to allow for review of the application by an independent party, iterative development of the budget proposal, and development of collaborative partnerships. Another improvement opportunity was the management of conflict regarding the design of the intervention that stemmed from marketing versus evidence-based approaches. The most important improvement opportunity was the need to develop a more exhaustive evaluation plan.^ Eight supplementary files are attached to appendices: Feasibility Discussion in Appendix 1, Grant Guidance and Workshop Notes in Appendix 2, Presentation to Texas Organ Sharing Alliance in Appendix 3, Team Recruitment Presentation in Appendix 5, Grant Project Narrative in Appendix 7, Federal Application Form in Appendix 8, and Budget Workbook with Budget Narrative in Appendix 9.^
Resumo:
Community health workers (CHWs) are volunteers or paid members of communities that perform outreach, patient assistance, health education, and assist in navigation of healthcare system amongst other duties. The utilization of CHWs in hospital and community setting provides health benefits to their communities while reducing cost to the overall healthcare system. ^ The general population of Texas lacks adequate access to primary care. An important indicator of such a crisis is excessive usage of emergency department services in Texas, especially by the large minority population within the state. Also, unmanaged chronic diseases have been shown to be correlated with the excessive usage of emergency services. According to a recent survey of 25 Houston metropolitan area hospitals, almost 54% of the ER visits could have been resolved in primary care settings. A Galveston based study also indicated that the ER usage was higher amongst African-Americans and Latinos. Meanwhile, 28.5% of the total ER visits were made by Latinos from the surrounding areas (Begley et al., 2007). There is substantial evidence present which indicates enormous cost-savings that CHWs have produced in Texas and nationwide through reduction in unnecessary ER visits along with better management of chronic diseases (Fedder et al, 2003). ^ This paper provides an analysis regarding the need and importance for sustainable and stable sources of funding for Community health workers (CHWs) in Texas utilizing Kingdon's model of Agenda Setting as framework. The policy analysis is also aimed at reporting on the policy process and actions taken by Children at Risk to address this critical issue. Children at Risk, a Houston based advocacy organization, has created a legislative proposal that calls on the Texas Health and Human Commission to apply for a Medicaid §§1115 waiver to provide sustainable sources of funding for CHWs, Rep. John Zerwas sponsored HB 2244 bill and it was filed on March 3, 2011. The bill would affect the use of CHWs in Texas in two ways: 1) through the establishment and operation of a program designed to train and educate CHWs 2) by creating a statewide training and certification advisory committee. The advisory committee is required in the bill to submit recommendations for providing sustainable funding and employment for CHWs. The HB 2244 failed to move out of the House Public Health committee. However, HB2244 was amended into HB 2610 introduced by Representative Guillen. The House Bill 2610 is geared towards establishing a community-based navigator program in order to assist individuals applying for public assistance through the Internet. The House Bill 2610 was signed by the Governor and will be effective September 1, 2011.^
Resumo:
En los últimos tiempos se ha fomentado, a través de distintas normas, la protección del medio ambiente como parte integrante de las diferentes actividades y políticas tanto del sector público como privado, con el propósito de lograr un desarrollo equilibrado y sostenible, compatible con el actual modelo económico. En función de ello, en una bodega emplazada en Maipú (Mendoza, Argentina) se realizó un diagnóstico (Revisión Inicial Ambiental - RIA) para conocer la situación actual del establecimiento con respecto a su relación con el medio ambiente. Una vez recabada la información y concluido el diagnóstico, se planteó un plan de medidas de gestión ambiental. Dichas medidas, que incorporaron los nuevos conceptos de producción limpia, ecoeficiencia y buenas prácticas ambientales, fueron documentadas a través de registros y permitieron conocer el desempeño ambiental a partir de los indicadores propuestos para cada uno de los Puntos Críticos ambientales (PCA). La propuesta inicial del presente trabajo fue lograr que la implementación de las medidas de acción, junto con los registros e indicadores de desempeño ambiental, sirvieran de soporte decisorio y brindaran los lineamientos básicos para diseñar un Sistema de Gestión Ambiental (SGA) que, junto con las Auditorías Ambientales (AA), formaran parte de la propuesta final.
Resumo:
Los primeros diez años del nuevo siglo nos encuentran con un bagaje de producción científica y trabajos de campo a partir de los cuales podemos reflexionar sobre la importancia de abordar la violencia cuando hablamos de políticas públicas de seguridad en sociedades democráticas. Ello implica reconocer un recorte del tema y una toma de posición alrededor de la cual iremos reconstruyendo la problemática de la seguridad que va más allá del delincuente, la asociación del problema de la seguridad al problema del delito, la tipificación de delitos y las técnicas disciplinarias. Nuestra atención esta dirigida a la violencia, la política expresada en políticas públicas y la expresión de las subjetividades en el miedo a ser víctima.
Resumo:
In medicine, the vast majority of conscientious objection (CO) is exercised within the reproductive healthcare field – particularly for abortion and contraception. Current laws and practices in various countries around CO in reproductive healthcare show that it is unworkable and frequently abused, with harmful impacts on women's healthcare and rights. CO in medicine is supposedly analogous to CO in the military, but in fact the two have little in common. This paper argues that CO in reproductive health is not actually Conscientious Objection, but Dishonourable Disobedience (DD) to laws and ethical codes. Healthcare professionals who exercise CO are using their position of trust and authority to impose their personal beliefs on patients, who are completely dependent on them for essential healthcare. Health systems and institutions that prohibit staff from providing abortion or contraception services are being discriminatory by systematically denying healthcare services to a vulnerable population and disregarding conscience rights for abortion providers. CO in reproductive healthcare should be dealt with like any other failure to perform one's professional duty, through enforcement and disciplinary measures. Counteracting institutional CO may require governmental or even international intervention.