908 resultados para Hyperspectral endmember extraction
Resumo:
The algorithm creates a buffer area around the cartographic features of interest in one of the images and compare it with the other one. During the comparison, the algorithm calculates the number of equals and different points and uses it to calculate the statistical values of the analysis. One calculated statistical value is the correctness, which shows the user the percentage of points that were correctly extracted. Another one is the completeness that shows the percentage of points that really belong to the interest feature. And the third value shows the idea of quality obtained by the extraction method, since that in order to calculate the quality the algorithm uses the correctness and completeness previously calculated. All the performed tests using this algorithm were possible to use the statistical values calculated to represent quantitatively the quality obtained by the extraction method executed. So, it is possible to say that the developed algorithm can be used to analyze extraction methods of cartographic features of interest, since that the results obtained were promising.
Resumo:
Objective: To compare with pristine sites bone resorption and soft tissue adaptation at implants placed immediately into extraction sockets (IPIES) in conjunction with deproteinized bovine bone mineral (DBBM) particles and a collagen membrane.Material and methods: The mesial root of the third premolar in the left side of the mandible was endodontically treated (Test). Flaps were elevated, the tooth hemi-sectioned, and the distal root removed to allow the immediate installation of an implant into the extraction socket in a lingual position. DBBM particles were placed into the defect and on the outer contour of the buccal bony ridge, concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. The premolar on the right side of the mandible was left in situ (control). Ground sections from the center of the implant as well as from the center of the distal root of the third premolar of the opposite side of the mandible were obtained. The histological image from the implant site was superimposed to that of the contralateral pristine distal alveolus, and dimensional variation evaluated for the hard tissue and the alveolar ridge.Results: After 3 months of healing, both histological and photographic evaluation revealed a reduction of hard and soft tissue dimensions.Conclusion: The contour augmentation performed with DBBM particles and a collagen membrane at the buccal aspects of implants placed IPIES was not able to maintain the tissue volume.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Testicular sperm extraction (TESE) associated with intracytoplasmic sperm injection has allowed many men presenting non-obstructive azoospermia to achieve fatherhood. Microdissection TESE (microTESE) was proposed as a method to improve sperm retrieval rates in these patients; however, there have been failures. Little is known about whether microTESE leads to spermatogenic alterations in the contralateral testis. We assessed histological outcomes of experimental microTESE in the contralateral testis of adult male rabbits. Nine adult male rabbits were divided into three groups: control (testicular biopsy to observe normal histological and morphometric values), sham (incision of the tunica vaginalis, and a contralateral testicular biopsy to observe histological and morphometric patterns, 45 days later), and study (left testicular microTESE, and a right testicular biopsy to observe histological and morphometric patterns, 45 days later). Sections were assessed by calculating Johnsen-like scores, and measuring total tubule diameter, lumen diameter and epithelial height. The results were compared using ANOVA and Bonferroni's statistical analysis. Morphometric evaluation of the seminiferous tubules did not demonstrate differences between the three groups. However, microTESE caused spermatogenic alterations, leading to maturation arrest in the contralateral testis.
Resumo:
Techniques based on signal analysis for leak detection in water supply systems typically use long pressure and/or flow data series of variable length. This paper presents the feature extraction from pressure signals and their application to the identification of changes related to the onset of a leak. Example signals were acquired from an experimental laboratory circuit, and features were extracted from temporal domain and from transformed signals. Statistical analysis of features values and a classification method were applied. It was verified the feasibility of using feature vectors for distinguish data acquired in the absence or presence of a leak.
Resumo:
Several cements are used as biomaterials. Biopolymers such as chitosan and collagen exhibit excellent biocompatibility and can be used in the remodeling of bone tissue. The cement must have high mechanical strength and compatibility with original tissue. In this context, the objective of this study was to extract, characterize and cross-link collagen from bovine tendon, forlater associate it with chitosan and calcium phosphate to obtain cements for bone regeneration. Glutaraldehyde was used as cross-linker in 0.1, 0.5, 1.0 and 10% concentration. Infrared analysis confirmed the presence of functional groups characteristic of collagen, whereas the capacity of water absorption decreased with the increasing of cross-linking degree. Denaturation temperatures of collagen samples were obtained by Differential Scanning Calorimetry and Scanning Electron Microscopy showed the fiber structure characteristics of collagen, which were more organized for high degree of cross-linking samples.
Resumo:
This manuscript describes the use of a tooth indicated for extraction due to orthodontic reasons as an anchorage aid to receive undesirable side effects caused by orthodontic uprighting of a contralateral molar tooth. The mandibular right second molar was mesially tipped as a result of loss of the adjacent first molar. Since the treatment plan involved extraction of the mandibular left first premolar, undesirable side effects associated with the molar uprighting movement were transferred to this tooth. Once the second molar was vertical, the premolar was extracted and the treatment continued. The results suggest that treatment time can be reduced if undesirable orthodontic mechanical side effects can be directed to a tooth whose extraction is indicated.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Third molar extraction is one of the most frequently performed procedures in the dental clinic, and it is associated with innumerable trans- and postoperative complications, such as pain, trismus, edema, localized alveolar osteitis, and surgical site infection. Some authors advocate the use of local or systemic antibiotics to reduce the incidence of these postoperative complications. However, several studies have revealed an insignificant gain after using antibiotics. Despite the risks of allergic reactions, toxicity, and the development of resistant microorganisms, about 50% of dentists routinely prescribe the use of prophylactic antibiotics for this purpose. The goal of this paper is to evaluate the scientific evidence that justifies antibiotic prescription to healthy patients undergoing third molar extraction.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this letter, a semiautomatic method for road extraction in object space is proposed that combines a stereoscopic pair of low-resolution aerial images with a digital terrain model (DTM) structured as a triangulated irregular network (TIN). First, we formulate an objective function in the object space to allow the modeling of roads in 3-D. In this model, the TIN-based DTM allows the search for the optimal polyline to be restricted along a narrow band that is overlaid upon it. Finally, the optimal polyline for each road is obtained by optimizing the objective function using the dynamic programming optimization algorithm. A few seed points need to be supplied by an operator. To evaluate the performance of the proposed method, a set of experiments was designed using two stereoscopic pairs of low-resolution aerial images and a TIN-based DTM with an average resolution of 1 m. The experimental results showed that the proposed method worked properly, even when faced with anomalies along roads, such as obstructions caused by shadows and trees.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)