897 resultados para Glass Powder
Resumo:
We present the experimental phase diagram of LiHoxEr1-xF4, a dilution series of dipolar-coupled model magnets. The phase diagram was determined using a combination of ac susceptibility and neutron scattering. Three unique phases in addition to the Ising ferromagnet LiHoF4 and the XY antiferromagnet LiErF4 have been identified. Below x = 0.86, an embedded spin-glass phase is observed, where a spin glass exists within the ferromagnetic structure. Below x = 0.57, an Ising spin glass is observed consisting of frozen needlelike clusters. For x ∼ 0.3–0.1, an antiferromagnetically coupled spin glass occurs. A reduction of TC(x) for the ferromagnet is observed which disobeys the mean-field predictions that worked for LiHoxY1-xF4.
Resumo:
OBJECTIVES The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. MATERIALS AND METHODS Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RESULTS RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. CONCLUSIONS The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. CLINICAL RELEVANCE When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.
Resumo:
Objectives The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Materials and methods Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance–Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal–Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Results Maximum irradiances were 1,545 mW/cm2 (SM), 2,179 mW/cm2 (HPM), and 4,156 mW/cm2 (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Conclusions Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. Clinical relevance When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.
Resumo:
PURPOSE The purpose of this study was to evaluate the bonding of glass ionomer cements (GICs) to sound and caries-affected dentin by microtensile bond strength (μTBS) and nanoleakage (NL) tests. METHODS Occlusal cavity preparations were made in 36 sound primary molars. Half of the specimens were submitted to a pH-cycling model to create simulated caries-affected dentin. Teeth were randomly restored with one of the three materials: (1) resin-modified GIC with nanoparticles (Ketac N100; KN); (2) resin-modified GIC (Vitremer; VI); and (3) high-viscosity GIC (Ketac Molar Easy Mix; KM). Specimens were tested using a microtensile test (1 mm/minute). One specimen from each tooth was immersed in ammoniacal silver nitrate for 24 hours and revealed after eight hours to assess interfacial NL. The μTBS means were analyzed by 2-way analysis of variance and Tukey's post hoc test. For NL, Kruskal-Wallis and Mann-Whitney tests were used (P<.05). RESULTS No difference was found between sound and caries-affected dentin (P>.05). KM showed the lowest GIC-dentin μTBS values, while VI and KN showed higher values. Infiltration of ammoniacal silver nitrate into the adhesive interface was not affected by sound or caries-affected dentin. CONCLUSION Caries-affected dentin does not jeopardize the bonding of glass ionomer cements to primary tooth dentin.
Resumo:
BACKGROUND Fractional exhaled nitric oxide (FENO), a non-invasive marker of eosinophilic airway inflammation, is increasingly used for diagnostic and therapeutic decisions in adult and paediatric asthma. Standardized guidelines for the measurement of FENO recommend performing FENO measurements before rather than after bronchial provocation tests. OBJECTIVE To investigate whether FENO levels decrease after a Mannitol dry powder (MDP) challenge in a clinical setting, and whether the extent of the decrease is influenced by number of MDP manoeuvres, baseline FENO, atopy and doctor diagnosed asthma. METHODS Children aged 6-16 years, referred for possible reactive airway disease to a respiratory outpatient clinic, performed an MDP challenge (Aridol®, Pharmaxis, Australia). FENO was measured in doublets immediately before and after the challenge test using the portable NIOX MINO® device (Aerocrine, Stockholm, Sweden). We analysed the data using Kruskal-Wallis rank tests, Wilcoxon signed rank tests and multivariable linear regressions. RESULTS One hundred and seven children completed both tests (mean±SD age 11.5±2.8 years). Overall, median (interquartile range) FENO decreased slightly by -2.5 ppb (-7.0, -0.5), from 18.5 ppb (10.5, 45.5) before the MDP challenge to 16.5 ppb thereafter (8.5, 40.5; p<0.001). In all participants, the change in FENO was smaller than one standard deviation of the baseline mean. The % fall in FENO was smaller in children with less MDP manoeuvres (e.g. higher bronchial responsiveness; p = 0.08) but was not influenced by levels of baseline FENO (p = 0.68), atopy (p = 0.84) or doctor diagnosed asthma (p = 0.93). CONCLUSION MDP challenge test influences FENO values but differences are small and clinically barely relevant.
Resumo:
Broken glass plate negative. Goal To design a simple protective enclosure for the two pieces of the glass plate negative, that allows the user to visualize the image as a whole. Treatment A sink mat was created by layering museum board and Volera foam, and "sinks" cut to fit the broken pieces along with thumb notches for ease of lifting. A portfolio of e-flute board, buckram, and cotton ties was built up around the sink mat to provide a protective enclosure that is easily stored on edge.
Resumo:
OBJECTIVES The aim of this prospective, randomized, controlled clinical study was to compare the clinical outcomes of the subgingival treatment with erythritol powder by means of an air-polishing (EPAP) device and of scaling and root planing (SRP) during supportive periodontal therapy (SPT). METHOD AND MATERIALS 40 patients enrolled in SPT were randomly assigned to two groups of equal size. Sites had to show signs of inflammation (bleeding on probing [BOP]-positive) and a probing pocket depth (PPD) of ≥ 4 mm, however, without presence of detectable subgingival calculus. During SPT, these sites were treated with EPAP or SRP, respectively. Full mouth and site-specific plaque indices, BOP, PPD, and clinical attachment level (CAL) were recorded at baseline (BL) and at 3 months, whereas the percentage of study sites positive for BOP (BOP+) was considered as primary outcome variable. Additionally, patient comfort using a visual analog scale (VAS) and the time needed to treat per site was evaluated. RESULTS At 3 months, mean BOP level measured 45.1% at test sites and 50.6% at control sites, respectively, without a statistically significant difference between the groups (P > .05). PPD and CAL slightly improved for both groups with comparable mean values at 3 months. Evaluation of patient tolerance showed statistically significantly better values among patients receiving the test treatment (mean VAS [0-10], 1.51) compared to SRP (mean VAS [0-10], 3.66; P = .0012). The treatment of test sites was set to 5 seconds per site. The treatment of control sites, on the other hand, lasted 85 seconds on average. CONCLUSION The new erythritol powder applied with an air-polishing device can be considered a promising modality for repeated instrumentation of residual pockets during SPT. CLINICAL RELEVANCE With regard to clinical outcomes during SPT, similar results can be expected irrespective of the two treatment approaches of hand instrumentation or subgingival application of erythritol powder with an air-polishing device in sites where only biofilm removal is required.
Resumo:
Discussing new or recently reformed citizenship tests in the USA, Australia, and Canada, this article asks whether they amount to a restrictive turn of new world citizenship, similar to recent developments in Europe. I argue that elements of a restrictive turn are noticeable in Australia and Canada, but only at the level of political rhetoric, not of law and policy, which remain liberal and inclusive. Much like in Europe, the restrictive turn is tantamount to Muslims and Islam moving to the center of the integration debate.
Resumo:
PURPOSE To determine the best-performing combination of three core buildup materials and three bonding materials based on their bond strength to ceramic blocks in vitro. MATERIALS AND METHODS The materials used for core buildup were a composite (Tetric EvoCeram), a compomer (Compoglass F), and a glass-ionomer cement (Ketac Fil Plus), and for bonding, a three-step etch-and-rinse adhesive (Syntac), a two-step etch-and-rinse adhesive (ExciTE), and a single-step system (RelyX Unicem). Bond strength to ceramic blocks was determined by shear bond strength testing. Fracture behavior was evaluated by scanning electron microscopy. RESULTS The highest adhesive values between buildup and ceramic were obtained using the materials Compoglass F and Syntac, followed by Compoglass F and ExciTE. Among the two other core buildups, Tetric EvoCeram performed better than Ketac Fil Plus, which was independent of the bonding materials. Adhesive fractures were characteristically observed with Syntac and ExciTE, and cohesive fractures were characteristically observed with RelyX Unicem. CONCLUSION These data show that compomers bonded with a multistep adhesive system achieved statistically significantly higher shear bond strength than composites and glass-ionomer cements. Within the limitations inherent to this in vitro study, the use of compomers for core buildup can be recommended.
Resumo:
The dynamics of glass is of importance in materials science but its nature has not yet been fully understood. Here we report that a verification of the temperature dependencies of the primary relaxation time or viscosity in the ultraslowing/ultraviscous domain of glass-forming systems can be carried out via the analysis of the inverse of the Dyre-Olsen temperature index. The subsequent analysis of experimental data indicates the possibility of the self-consistent description of glass-forming low-molecular-weight liquids, polymers, liquid crystals, orientationally disordered crystals and Ising spin-glass-like systems, as well as the prevalence of equations associated with the 'finite temperature divergence'. All these lead to a new formula for the configurational entropy in glass-forming systems. Furthermore, a link to the dominated local symmetry for a given glass former is identified here. Results obtained show a new relationship between the glass transition and critical phenomena.