953 resultados para Gallo, Maria Francesca of the Five Wounds, Saint, 1715-1791.
Resumo:
We have studied the phosphate mineral vantasselite Al4(PO4)3(OH)3·9H2O using a combination of SEM with EDX and Raman and infrared spectroscopy. Qualitative chemical analysis shows Al, Fe and P. Raman bands at 1013 and 1027cm−1 are assigned to the PO43−ν1 symmetric stretching mode. The observation of two bands suggests the non-equivalence of the phosphate units in the vantasselite structure. Raman bands at 1051, 1076 and 1090cm−1 are attributed to the PO43−ν3 antisymmetric stretching vibration. A comparison is made with the spectroscopy of wardite. Strong infrared bands at 1044, 1078, 1092, 1112, 1133, 1180 and 1210cm−1 are attributed to the PO43−ν3 antisymmetric stretching mode. Some of these bands may be due to δAl2OH deformation modes. Vibrational spectroscopy offers a mechanism for the study of the molecular structure of vantasselite.
Resumo:
Preface The 9th Australasian Conference on Information Security and Privacy (ACISP 2004) was held in Sydney, 13–15 July, 2004. The conference was sponsored by the Centre for Advanced Computing – Algorithms and Cryptography (ACAC), Information and Networked Security Systems Research (INSS), Macquarie University and the Australian Computer Society. The aims of the conference are to bring together researchers and practitioners working in areas of information security and privacy from universities, industry and government sectors. The conference program covered a range of aspects including cryptography, cryptanalysis, systems and network security. The program committee accepted 41 papers from 195 submissions. The reviewing process took six weeks and each paper was carefully evaluated by at least three members of the program committee. We appreciate the hard work of the members of the program committee and external referees who gave many hours of their valuable time. Of the accepted papers, there were nine from Korea, six from Australia, five each from Japan and the USA, three each from China and Singapore, two each from Canada and Switzerland, and one each from Belgium, France, Germany, Taiwan, The Netherlands and the UK. All the authors, whether or not their papers were accepted, made valued contributions to the conference. In addition to the contributed papers, Dr Arjen Lenstra gave an invited talk, entitled Likely and Unlikely Progress in Factoring. This year the program committee introduced the Best Student Paper Award. The winner of the prize for the Best Student Paper was Yan-Cheng Chang from Harvard University for his paper Single Database Private Information Retrieval with Logarithmic Communication. We would like to thank all the people involved in organizing this conference. In particular we would like to thank members of the organizing committee for their time and efforts, Andrina Brennan, Vijayakrishnan Pasupathinathan, Hartono Kurnio, Cecily Lenton, and members from ACAC and INSS.
Resumo:
Background Depression is a common psychiatric disorder in older people. The study aimed to examine the screening accuracy of the Geriatric Depression Scale (GDS) and the Collateral Source version of the Geriatric Depression Scale (CS-GDS) in the nursing home setting. Methods Eighty-eight residents from 14 nursing homes were assessed for depression using the GDS and the CS-GDS, and validated against clinician diagnosed depression using the Semi-structured Clinical Diagnostic Interview for DSM-IV-TR Axis I Disorders (SCID) for residents without dementia and the Provisional Diagnostic Criteria for Depression in Alzheimer Disease (PDCdAD) for those with dementia. The screening performances of five versions of the GDS (30-, 15-, 10-, 8-, and 4-item) and two versions of the CS-GDS (30- and 15-item) were analyzed using receiver operating characteristic (ROC) curves. Results Among residents without dementia, both the self-rated (AUC = 0.75–0.79) and proxy-rated (AUC = 0.67) GDS variations performed significantly better than chance in screening for depression. However, neither instrument adequately identified depression among residents with dementia (AUC between 0.57 and 0.70). Among the GDS variations, the 4- and 8-item scales had the highest AUC and the optimal cut-offs were >0 and >3, respectively. Conclusions The validity of the GDS in detecting depression requires a certain level of cognitive functioning. While the CS-GDS is designed to remedy this issue by using an informant, it did not have adequate validity in detecting depression among residents with dementia. Further research is needed on informant selection and other factors that can potentially influence the validity of proxy-based measures in the nursing home setting.
Resumo:
Background Family caregivers provide invaluable support to stroke survivors during their recovery, rehabilitation, and community re-integration. Unfortunately, it is not standard clinical practice to prepare and support caregivers in this role and, as a result, many experience stress and poor health that can compromise stroke survivor recovery and threaten the sustainability of keeping the stroke survivor at home. We developed the Timing it Right Stroke Family Support Program (TIRSFSP) to guide the timing of delivering specific types of education and support to meet caregivers' evolving needs. The objective of this multi-site randomized controlled trial is to determine if delivering the TIRSFSP across the stroke care continuum improves caregivers' sense of being supported and emotional well-being. Methods/design Our multi-site single-blinded randomized controlled trial will recruit 300 family caregivers of stroke survivors from urban and rural acute care hospitals. After completing a baseline assessment, participants will be randomly allocated to one of three groups: 1) TIRSFSP guided by a stroke support person (health care professional with stroke care experience), delivered in-person during acute care and by telephone for approximately the first six to 12 months post-stroke; 2) caregiver self-directed TIRSFSP with an initial introduction to the program by a stroke support person, or; 3) standard care receiving the educational resource "Let's Talk about Stroke" prepared by the Heart and Stroke Foundation. Participants will complete three follow-up quantitative assessments 3, 6, and 12-months post-stroke. These include assessments of depression, social support, psychological well-being, stroke knowledge, mastery (sense of control over life), caregiving assistance provided, caregiving impact on everyday life, and indicators of stroke severity and disability. Qualitative methods will also be used to obtain information about caregivers' experiences with the education and support received and the impact on caregivers' perception of being supported and emotional well-being. Discussion This research will determine if the TIRSFSP benefits family caregivers by improving their perception of being supported and emotional well-being. If proven effective, it could be recommended as a model of stroke family education and support that meets the Canadian Stroke Best Practice Guideline recommendation for providing timely education and support to families through transitions.
Resumo:
- Objective Examine feasibility of conducting a randomized controlled trial of the Timing it Right Stroke Family Support Program (TIRSFSP) and collect pilot data. - Design Multi-site mixed method randomized controlled trial. - Setting Acute and community care in three Canadian cities. - Subjects Caregivers were family members or friends providing care to individuals who experienced their first stroke. - Intervention The TIRSFSP offered in two formats, self-directed by the caregiver or stroke support person-directed over time, were compared to standard care. - Main Measures Caregivers completed baseline and follow-up measures 1, 3 and 6 months post-stroke including Centre for Epidemiological Studies Depression, Positive Affect, Social Support, and Mastery Scales. We completed in-depth qualitative interviews with caregivers and maintained intervention records describing support provided to each caregiver. - Results Thirty-one caregivers received standard care (n=10), self-directed (n=10), or stroke support person-directed (n=11) interventions. We retained 77% of the sample through 6-months. Key areas of support derived from intervention records (n=11) related to caregiver wellbeing, caregiving strategies, patient wellbeing, community re-integration, and service delivery. Compared to standard care, caregivers receiving the stroke support person-directed intervention reported improvements in perceived support (estimate 3.1, P=.04) and mastery (estimate .35, P=.06). Qualitative caregiver interviews (n=19) reflected the complex interaction between caregiver needs, preferences and available options when reporting on level of satisfaction. - Conclusions Preliminary findings suggest the research design is feasible, caregivers’ needs are complex, and the support intervention may enhance caregivers’ perceived support and mastery. The intervention will be tested further in a large scale trial.
Resumo:
Background Foot dorsiflexion plays an essential role in both controlling balance and human gait. Electromyography (EMG) and sonomyography (SMG) can provide information on several aspects of muscle function. The aim was to establish the relationship between the EMG and SMG variables during isotonic contractions of foot dorsiflexors. Methods Twenty-seven healthy young adults performed the foot dorsiflexion test on a device designed ad hoc. EMG variables were maximum peak and area under the curve. Muscular architecture variables were muscle thickness and pennation angle. Descriptive statistical analysis, inferential analysis and a multivariate linear regression model were carried out. The confidence level was established with a statistically significant p-value of less than 0.05. Results The correlation between EMG variables and SMG variables was r = 0.462 (p < 0.05). The linear regression model to the dependent variable “peak normalized tibialis anterior (TA)” from the independent variables “pennation angle and thickness”, was significant (p = 0.002) with an explained variance of R2 = 0.693 and SEE = 0.16. Conclusions There is a significant relationship and degree of contribution between EMG and SMG variables during isotonic contractions of the TA muscle. Our results suggest that EMG and SMG can be feasible tools for monitoring and assessment of foot dorsiflexors. TA muscle parameterization and assessment is relevant in order to know that increased strength accelerates the recovery of lower limb injuries.
Resumo:
Background The evaluation of the hand function is an essential element within the clinical practice. The usual assessments are focus on the ability to perform activities of daily life. The inclusion of instruments to measure kinematic variables provides a new approach to the assessment. Inertial sensors adapted to the hand could be used as a complementary instrument to the traditional assessment. Material: clinimetric assessment (Upper Limb Functional Index, Quick Dash), antrophometric variables (eight and weight), dynamometry (palm preasure) was taken. Functional analysis was made with Acceleglove system for the right hand and computer system. The glove has six acceleration sensor, one on each finger and another one on the reverse palm. Method Analytic, transversal approach. Ten healthy subject made six task on evaluation table (tripod pinch, lateral pinch and tip pinch, extension grip, spherical grip and power grip). Each task was made and measure three times, the second one was analyze for the results section. A Matlab script was created for the analysis of each movement and detection phase based on module vector. Results The module acceleration vector offers useful information of the hand function. The data analysis obtained during the performance of functional gestures allows to identify five different phases within the movement, three static phase and tow dynamic, each module vector was allied to one task. Conclusion Module vector variables could be used for the analysis of the different task made by the hand. Inertial sensor could be use as a complement for the traditional assessment system.
Resumo:
PURPOSE: The purpose of the present study was to analyze the neuromuscular responses during the performance of a sit to stand [STS] task in water and on dry land. SCOPE: 10 healthy subjects, five males and five females were recruited for study. Surface electromyography sEMG was used for lower limb and trunk muscles maximal voluntarty contraction [MVC] and during the STS task. RESULTS: Muscle activity was significantly higher on dry land than in water normalized signals by MVC from the quadriceps-vastus medialis [17.3%], the quadriceps - rectus femoris [5.3%], the long head of the biceps femoris [5.5%], the tibialis anterior [13.9%], the gastrocnemius medialis [3.4%], the soleus [6.2%]. However, the muscle activity was higher in water for the rectus abdominis [-26.6%] and the erector spinae [-22.6%]. CONCLUSIONS: This study for the first time describes the neuromuscular responses in healthy subjects during the performance of the STS task in water. The differences in lower limb and trunk muscle activity should be considered when using the STS movement in aquatic rehabilitation.
Resumo:
The hemodynamic response function (HRF) describes the local response of brain vasculature to functional activation. Accurate HRF modeling enables the investigation of cerebral blood flow regulation and improves our ability to interpret fMRI results. Block designs have been used extensively as fMRI paradigms because detection power is maximized; however, block designs are not optimal for HRF parameter estimation. Here we assessed the utility of block design fMRI data for HRF modeling. The trueness (relative deviation), precision (relative uncertainty), and identifiability (goodness-of-fit) of different HRF models were examined and test-retest reproducibility of HRF parameter estimates was assessed using computer simulations and fMRI data from 82 healthy young adult twins acquired on two occasions 3 to 4 months apart. The effects of systematically varying attributes of the block design paradigm were also examined. In our comparison of five HRF models, the model comprising the sum of two gamma functions with six free parameters had greatest parameter accuracy and identifiability. Hemodynamic response function height and time to peak were highly reproducible between studies and width was moderately reproducible but the reproducibility of onset time was low. This study established the feasibility and test-retest reliability of estimating HRF parameters using data from block design fMRI studies.
Resumo:
In 2014, the northern outlying population of carnivorous marsupial Dusky Antechinus (Antechinus swainsonii) was nominated a new species, A. arktos. Here, we describe a further new species in the dasyurid A. swainsonii complex, which now contains five taxa. We recognise two distinct species from Tasmania, formerly represented by A. swainsonii swainsonii (Waterhouse); one species (and 2 subspecies) from mainland south-eastern Australia, formerly known as A. swainsonii mimetes (Thomas) and A. swainsonii insulanus Davison; and one species from the Tweed Caldera in mid-eastern Australia, formerly known as A. s. mimetes but recently described as A. arktos Baker, Mutton, Hines and Van Dyck. Primacy of discovery dictates the Tasmanian Dusky Antechinus A. swainsonii (Waterhouse) is nominate; the Mainland Dusky Antechinus taxa, one raised from subspecies within A. swainsonii mimetes (Thomas) is elevated to species (now A. mimetes mimetes) and the other, A. swainsonii insulanus Davison is transferred as a subspecies of A. mimetes (now A. mimetes insulanus); a species from Tasmania, the Tasman Peninsula Dusky Antechinus, is named A. vandycki sp. nov. These taxa are strongly differentiated: geographically (in allopatry), morphologically (in coat colour and craniodental features) and genetically (in mtDNA, 7.5-12.5% between species pairs).
Resumo:
Purpose – The purpose of this paper is to investigate the extent of directors breaching the reporting requirements of the Australian Stock Exchange (ASX) and the Corporations Act in Australia. Further, it seeks to assess whether directors in Australia achieve abnormal returns from trades in their own companies. Design/methodology/approach – Using an event study approach on an Australian sample, abnormal returns for a range of situations were estimated. Findings – A total of 13 (seven) per cent of own‐company directors trades do not meet the ASX (Corporations Act) requirement of reporting within five (14) business days. Directors do achieve abnormal returns through trading in shares of their own companies. Ignoring transaction costs, outsiders can achieve abnormal returns by imitating directors' trades. Analysis of returns to directors after they trade but before they announce the trade to the market shows that directors are making small but statistically significant returns that are not available to the market. Analysis of returns to directors subsequent to the ASX reporting requirement up to the day the trade is reported shows that directors are making small but statistically significant returns that should be available to the market. Research limitations/implications – Future research should investigate the linkages between late reporting by directors and disadvantages to outside shareholders and the implementation of internal policies implemented to mitigate insider trading. Practical implications – Market participants should remain vigilant regarding the potential for late/non‐reporting of directors' trades. Originality/value – Uncovering breaches of reporting regulations are particularly important given that directors tend to purchase (sell) shares when the price is low (high), thereby achieving abnormal returns.
Resumo:
Objectives - It has long been suspected that susceptibility to ankylosing spondylitis (AS) is influenced by genes lying distant to the major histocompatibility complex. This study compares genetic models of AS to assess the most likely mode of inheritance, using recurrence risk ratios in relatives of affected subjects. Methods - Recurrence risk ratios in different degrees of relatives were determined using published data from studies specifically designed to address the question. The methods of Risch were used to determine the expected recurrence risk ratios in different degrees of relatives, assuming equal first degree relative recurrence risk between models. Goodness of fit was determined by χ2 comparison of the expected number of affected subjects with the observed number, given equal numbers of each type of relative studied. Results - The recurrence risks in different degrees of relatives were: monozygotic (MZ) twins 63% (17/27), first degree relatives 8.2% (441/5390), second degree relatives 1.0% (8/834), and third degree relatives 0.7% (7/997). Parent-child recurrence risk (7.9%, 37/466) was not significantly different from the sibling recurrence risk (8.2%, 404/4924), excluding a significant dominance genetic component to susceptibility. Poor fitting models included single gene, genetic heterogeneity, additive, two locus multiplicative, and one locus and residual polygenes (χ2 > 32 (two degrees of freedom), p < 10-6 for all models). The best fitting model studied was a five locus model with multiplicative interaction between loci (χ2 = 1.4 (two degrees of freedom), p = 0.5). Oligogenic multiplicative models were the best fitting over a range of population prevalences and first degree recurrence risk rates. Conclusions - This study suggests that of the genetic models tested, the most likely model operating in AS is an oligogenic model with predominantly multiplicative interaction between loci.
Resumo:
Objective The ank/ank mouse develops a phenotype similar to ankylosing spondylitis (AS) in humans. ANKH, the human homolog of the mutated gene in the ank/ank mouse, has been implicated in familial autosomal-dominant chondrocalcinosis and autosomal-dominant craniometaphyseal dysplasia. This study was undertaken to investigate the role of ANKH in susceptibility to and clinical manifestations of AS. Methods Sequence variants were identified by genomic sequencing of the 12 ANKH exons and their flanking splice sites in 48 AS patients; variants were then screened in 233 patients and 478 controls. Linkage to the ANKH locus was assessed in 185 affected-sibling-pair families. Results Five single-nucleotide polymorphisms were identified within the coding region and flanking splice sites. No association between either susceptibility to AS or its clinical manifestations and these novel polymorphisms, or between disease susceptibility and 3 known promoter variants, was seen. No linkage between the ANKH locus and AS was observed. Multipoint exclusion mapping rejected the hypothesis of a locus of a magnitude λ≥1.4 (logarithm of odds score <-2) (equivalent to a genetic contribution of >10% to the AS sibling recurrence risk ratio) within this area contributing to AS. Conclusion These findings indicate that ANKH is not significantly involved in susceptibility to or clinical manifestations of AS.
Resumo:
This work aims to understand the influence of TiO2 surface structure in Au/TiO2 catalysts on CO oxidation. Au nanoparticles (3 wt%) in the range of 4 to 8 nm were loaded onto four kinds of TiO2 surfaces, which had different surface structures and were synthesized by calcining hydrogen titanate nanotubes at various temperatures and in different atmospheres. The Au catalyst supported on anatase nanorods exhibited the highest activity in CO oxidation at 30 °C among all the five Au/TiO2 catalysts including the reference catalyst of Au/TiO2-P25. X-ray photoelectron spectroscopy (XPS) and infrared emission spectra (IES) results indicate that the anatase nanorods have the most active surface on which water molecules can be strongly adsorbed and OH groups can be formed readily. Theoretical calculation indicates that the surface OH can facilitate the O2 adsorption on the anatase surface. Such active surface features are conducive to the O2 activation and CO oxidation
Resumo:
Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.