993 resultados para Función ventricular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with left ventricular noncompaction (LVNC) have an increased risk for life-threatening ventricular arrhythmias. The benefit from implantable cardioverter-defibrillators (ICD) in these patients has been investigated only in small series. Therefore, the aim of the present study was to analyze the clinical outcome of a larger population of patients with LVNC who were treated with an ICD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accurate position of the ventricular catheter inside the frontal horn of the lateral ventricle is essential to prevent proximal failure in shunt surgery. For optimal placement, endoscopic- and image-guided techniques are available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter-related infection of CSF is a potentially life-threatening complication of external ventricular drainage (EVD). When using EVD catheters, contact between the ventricular system and skin surface occurs and CSF infection is possible. The aim of this analysis was to compare the efficacy of silver-bearing EVD catheters for reducing the incidence of infection with standard nonimpregnated EVD catheters in neurosurgical patients with acute hydrocephalus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may result in faster left ventricular recovery. Methods We investigated clinical outcomes of high-risk patients with severe aortic stenosis undergoing medical treatment (n = 71) or TAVI (n = 256) stratified by left ventricular ejection fraction (LVEF) in a prospective single center registry. Results Twenty-five patients (35%) among the medical cohort were found to have an LVEF≤30% (mean 26.7±4.1%) and 37 patients (14%) among the TAVI patients (mean 25.2±4.4%). Estimated peri-interventional risk as assessed by logistic EuroSCORE was significantly higher in patients with severely impaired LVEF as compared to patients with LVEF>30% (medical/TAVI 38.5±13.8%/40.6±16.4% versus medical/TAVI 22.5±10.8%/22.1±12.8%, p <0.001). In patients undergoing TAVI, there was no significant difference in the combined endpoint of death, myocardial infarction, major stroke, life-threatening bleeding, major access-site complications, valvular re-intervention, or renal failure at 30 days between the two groups (21.0% versus 27.0%, p = 0.40). After TAVI, patients with LVEF≤30% experienced a rapid improvement in LVEF (from 25±4% to 34±10% at discharge, p = 0.002) associated with improved NYHA functional class at 30 days (decrease ≥1 NYHA class in 95%). During long-term follow-up no difference in survival was observed in patients undergoing TAVI irrespective of baseline LVEF (p = 0.29), whereas there was a significantly higher mortality in medically treated patients with severely reduced LVEF (log rank p = 0.001). Conclusion TAVI in patients with severely reduced left ventricular function may be performed safely and is associated with rapid recovery of systolic left ventricular function and heart failure symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical treatment of mitral leaflet prolapse using artificial neochordae shows excellent outcomes. Upcoming devices attempt the same treatment in a minimally invasive way but target the left ventricular apex as an anchoring point, rather than the tip of the corresponding papillary muscle. In this study, cine cardiac magnetic resonance imaging was used to compare these 2 different anchoring positions and their dynamic relationship with the mitral leaflets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of positioning and geometry of ventricular cannulas for contemporary continuous flow Left Ventricular Assist Devices (LVADs) was evaluated in a non-beating isolated heart preparation with borescopic visualization. Preload and LVAD flow were varied to evaluate degrees of ventricular decompression up to the point of ventricular collapse. The performance of a flanged cannula was compared to a conventional bevel-tipped cannula: quantitatively by the maximal flow attainable, and qualitatively by visualization of fluid tracer particles within the ventricular chamber. Three forms of ventricular suck-down occurred: concentric collapse, gradual entrainment and instantaneous entrainment. In some circumstances, unstable oscillations of the ventricle were observed prior to complete collapse. Under conditions of low preload, the flanged cannula demonstrated less positional sensitivity, provided greater flow, and exhibited fewer areas of stagnation than the beveled cannula. These observations warrant further consideration of a flanged ventricular cannula to mitigate complications encountered with conventional cannulae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Veteran endurance athletes have an increased risk of developing atrial fibrillation (AF), with a striking male predominance. We hypothesized that male athletes were more prone to atrial and ventricular remodeling and investigated the signal-averaged P wave and factors that promote the occurrence of AF. Nonelite athletes scheduled to participate in the 2010 Grand Prix of Bern, a 10-mile race, were invited. Of the 873 marathon and nonmarathon runners who were willing to participate, 68 female and 70 male athletes were randomly selected. The runners with cardiovascular disease or elevated blood pressure (>140/90 mm Hg) were excluded. Thus, 121 athletes were entered into the final analysis. Their mean age was 42 ± 7 years. No gender differences were found for age, lifetime training hours, or race time. The male athletes had a significantly longer signal-averaged P-wave duration (136 ± 12 vs 122 ± 10 ms; p <0.001). The left atrial volume was larger in the male athletes (56 ± 13 vs 49 ± 10 ml; p = 0.001), while left atrial volume index showed no differences (29 ± 7 vs 30 ± 6 ml/m²; p = 0.332). In male athletes, the left ventricular mass index (107 ± 17 vs 86 ± 16 g/m²; p <0.001) and relative wall thickness (0.44 ± 0.06 vs 0.41 ± 0.07; p = 0.004) were greater. No differences were found in the left ventricular ejection fraction (63 ± 4% vs 66 ± 6%; p = 0.112) and mitral annular tissue Doppler e' velocity (10.9 ± 1.5 vs 10.6 ± 1.5 cm/s; p = 0.187). However, the tissue Doppler a' velocity was higher (8.7 ± 1.2 vs 7.6 ± 1.3 cm/s; p < 0.001) in the male athletes. Male athletes had a higher systolic blood pressure at rest (123 ± 9 vs 110 ± 11 mm Hg; p < 0.001) and at peak exercise (180 ± 15 vs 169 ± 19 mm Hg; p = 0.001). In the frequency domain analysis of heart rate variability, the sympatho-vagal balance, represented by the low/high-frequency power ratio, was significantly greater in male athletes (5.8 ± 2.8 vs 3.9 ± 1.9; p < 0.001). Four athletes (3.3%) had at least one documented episode of paroxysmal AF, all were men (p = 0.042). In conclusion, for a comparable amount of training and performance, male athletes showed a more pronounced atrial remodeling, a concentric type of ventricular remodeling, and an altered diastolic function. A higher blood pressure at rest and during exercise and a higher sympathetic tone might be causal. The altered left atrial substrate might facilitate the occurrence of AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right ventricular (RV) systolic function is prognostically important, but its assessment by echocardiography remains challenging, in part because of the multitude of available measurement methods. The purpose of this prospective study was to rank these methods against the reference of RV ejection fraction (EF) as obtained in a broad clinical population by magnetic resonance imaging (MRI).