994 resultados para Forecast error


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A free-space optical (FSO) laser communication system with perfect fast-tracking experiences random power fading due to atmospheric turbulence. For a FSO communication system without fast-tracking or with imperfect fast-tracking, the fading probability density function (pdf) is also affected by the pointing error. In this thesis, the overall fading pdfs of FSO communication system with pointing errors are calculated using an analytical method based on the fast-tracked on-axis and off-axis fading pdfs and the fast-tracked beam profile of a turbulence channel. The overall fading pdf is firstly studied for the FSO communication system with collimated laser beam. Large-scale numerical wave-optics simulations are performed to verify the analytically calculated fading pdf with collimated beam under various turbulence channels and pointing errors. The calculated overall fading pdfs are almost identical to the directly simulated fading pdfs. The calculated overall fading pdfs are also compared with the gamma-gamma (GG) and the log-normal (LN) fading pdf models. They fit better than both the GG and LN fading pdf models under different receiver aperture sizes in all the studied cases. Further, the analytical method is expanded to the FSO communication system with beam diverging angle case. It is shown that the gamma pdf model is still valid for the fast-tracked on-axis and off-axis fading pdfs with point-like receiver aperture when the laser beam is propagated with beam diverging angle. Large-scale numerical wave-optics simulations prove that the analytically calculated fading pdfs perfectly fit the overall fading pdfs for both focused and diverged beam cases. The influence of the fast-tracked on-axis and off-axis fading pdfs, the fast-tracked beam profile, and the pointing error on the overall fading pdf is also discussed. At last, the analytical method is compared with the previous heuristic fading pdf models proposed since 1970s. Although some of previously proposed fading pdf models provide close fit to the experiment and simulation data, these close fits only exist under particular conditions. Only analytical method shows accurate fit to the directly simulated fading pdfs under different turbulence strength, propagation distances, receiver aperture sizes and pointing errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To estimate a parameter in an elliptic boundary value problem, the method of equation error chooses the value that minimizes the error in the PDE and boundary condition (the solution of the BVP having been replaced by a measurement). The estimated parameter converges to the exact value as the measured data converge to the exact value, provided Tikhonov regularization is used to control the instability inherent in the problem. The error in the estimated solution can be bounded in an appropriate quotient norm; estimates can be derived for both the underlying (infinite-dimensional) problem and a finite-element discretization that can be implemented in a practical algorithm. Numerical experiments demonstrate the efficacy and limitations of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper assesses the influence of an adoption of IAS/IFRS or US GAAP on the financial analysts’ forecast accuracy in a homogenous institutional framework. Our findings suggest that the forecast accuracy is higher for estimates based on IFRS or US GAAP data than for forecasts based on German GAAP data.Moreover, in the year of switching from German GAAP to US GAAP the forecast accuracy is lower than in other years. The paper contributes to prior research by providing evidence about the usefulness of international accounting data and about the adoption effects of a change to such accounting principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper I consider the impact of a noisy indicator regarding a manager’s manipulative behavior on optimal effort incentives and the extent of earnings management. The analysis in this paper extends a twotask, single performance measure LEN model by including a binary random variable. I show that contracting on the noisy indicator variable is not always useful. More specifically, the principal uses the indicator variable to prevent earnings management only under conditions where manipulative behavior is not excessive. Thus, under conditions of excessive earnings management, accounting adjustments that yield a more congruent overall performance measure can be more effective than an appraisal of the existence of earnings management to mitigate the earnings management problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QUESTION UNDER STUDY To establish at what stage Swiss hospitals are in implementing an internal standard concerning communication with patients and families after an error that resulted in harm. METHODS Hospitals were identified via the Swiss Hospital Association's website. An anonymous questionnaire was sent during September and October 2011 to 379 hospitals in German, French or Italian. Hospitals were asked to specify their hospital type and the implementation status of an internal hospital standard that decrees that patients or their relatives are to be promptly informed about medical errors that result in harm. RESULTS Responses from a total of 205 hospitals were received, a response rate of 54%. Most responding hospitals (62%) had an error disclosure standard or planned to implement one within 12 months. The majority of responding university and acute care (75%) hospitals had introduced a disclosure standard or were planning to do so. In contrast, the majority of responding psychiatric, rehabilitation and specialty (53%) clinics had not introduced a standard. CONCLUSION It appears that Swiss hospitals are in a promising state in providing institutional support for practitioners disclosing medical errors to patients. This has been shown internationally to be one important factor in encouraging the disclosure of medical errors. However, many hospitals, in particular psychiatric, rehabilitation and specialty clinics, have not implemented an error disclosure policy. Further research is needed to explore the underlying reasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces an extended hierarchical task analysis (HTA) methodology devised to evaluate and compare user interfaces on volumetric infusion pumps. The pumps were studied along the dimensions of overall usability and propensity for generating human error. With HTA as our framework, we analyzed six pumps on a variety of common tasks using Norman’s Action theory. The introduced method of evaluation divides the problem space between the external world of the device interface and the user’s internal cognitive world, allowing for predictions of potential user errors at the human-device level. In this paper, one detailed analysis is provided as an example, comparing two different pumps on two separate tasks. The results demonstrate the inherent variation, often the cause of usage errors, found with infusion pumps being used in hospitals today. The reported methodology is a useful tool for evaluating human performance and predicting potential user errors with infusion pumps and other simple medical devices.