925 resultados para Fix and optimize


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context. This thesis is framed in experimental software engineering. More concretely, it addresses the problems arisen when assessing process conformance in test-driven development experiments conducted by UPM's Experimental Software Engineering group. Process conformance was studied using the Eclipse's plug-in tool Besouro. It has been observed that Besouro does not work correctly in some circumstances. It creates doubts about the correction of the existing experimental data which render it useless. Aim. The main objective of this work is the identification and correction of Besouro's faults. A secondary goal is fixing the datasets already obtained in past experiments to the maximum possible extent. This way, existing experimental results could be used with confidence. Method. (1) Testing Besouro using different sequences of events (creation methods, assertions etc..) to identify the underlying faults. (2) Fix the code and (3) fix the datasets using code specially created for this purpose. Results. (1) We confirmed the existence of several fault in Besouro's code that affected to Test-First and Test-Last episode identification. These faults caused the incorrect identification of 20% of episodes. (2) We were able to fix Besouro's code. (3) The correction of existing datasets was possible, subjected to some restrictions (such us the impossibility of tracing code size increase to programming time. Conclusion. The results of past experiments dependent upon Besouro's data could no be trustable. We have the suspicion that more faults remain in Besouro's code, whose identification requires further analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to analyse several factors of variation of slurry composition and to establish prediction equations for potential methane (CH4) and ammonia (NH3) emissions. Seventy-nine feed and slurry samples were collected at two seasons (summer and winter) from commercial pig farms sited at two Spanish regions (Centre and Mediterranean). Nursery, growing-fattening, gestating and lactating facilities were sampled. Feed and slurry composition were determined, and potential CH4 and NH3 emissions measured at laboratory. Feed nutrient contents were used as covariates in the analysis. Near infrared reflectance spectroscopy (NIRS) was evaluated as a predicting tool for slurry composition and potential gaseous emissions. A wide variability was found both in feed and slurry composition. Mediterranean farms had a higher pH (p<0.001) and ash (p=0.02) concentration than those located at the Centre of Spain. Also, type of farm affected ether extract content of the slurry (p=0.02), with highest values obtained for the youngest animal facilities. Results suggested a buffer effect of dietary fibre on slurry pH and a direct relationship (p<0.05) with fibre constituents of manure. Dietary protein content did not affect slurry nitrogen content but decreased (p=0.003) total and volatile solids concentration. Prediction models of potential NH3 emissions (R2=0.89) and CH4 yield (R2=0.61) were obtained from slurry composition. Predictions from NIRS showed a high accuracy for most slurry constituents (R2>0.90) and similar accuracy of prediction of potential NH3 and CH4 emissions (R2=0.84 and 0.68, respectively) to models using slurry characteristics, which can be of interest to estimate emissions from commercial farms and establish mitigation strategies or optimize biogas production.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an adaptation of the Cross-Entropy (CE) method to optimize fuzzy logic controllers. The CE is a recently developed optimization method based on a general Monte-Carlo approach to combinatorial and continuous multi-extremal optimization and importance sampling. This work shows the application of this optimization method to optimize the inputs gains, the location and size of the different membership functions' sets of each variable, as well as the weight of each rule from the rule's base of a fuzzy logic controller (FLC). The control system approach presented in this work was designed to command the orientation of an unmanned aerial vehicle (UAV) to modify its trajectory for avoiding collisions. An onboard looking forward camera was used to sense the environment of the UAV. The information extracted by the image processing algorithm is the only input of the fuzzy control approach to avoid the collision with a predefined object. Real tests with a quadrotor have been done to corroborate the improved behavior of the optimized controllers at different stages of the optimization process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El principal objetivo de este trabajo es proporcionar una solución en tiempo real basada en visión estéreo o monocular precisa y robusta para que un vehículo aéreo no tripulado (UAV) sea autónomo en varios tipos de aplicaciones UAV, especialmente en entornos abarrotados sin señal GPS. Este trabajo principalmente consiste en tres temas de investigación de UAV basados en técnicas de visión por computador: (I) visual tracking, proporciona soluciones efectivas para localizar visualmente objetos de interés estáticos o en movimiento durante el tiempo que dura el vuelo del UAV mediante una aproximación adaptativa online y una estrategia de múltiple resolución, de este modo superamos los problemas generados por las diferentes situaciones desafiantes, tales como cambios significativos de aspecto, iluminación del entorno variante, fondo del tracking embarullado, oclusión parcial o total de objetos, variaciones rápidas de posición y vibraciones mecánicas a bordo. La solución ha sido utilizada en aterrizajes autónomos, inspección de plataformas mar adentro o tracking de aviones en pleno vuelo para su detección y evasión; (II) odometría visual: proporciona una solución eficiente al UAV para estimar la posición con 6 grados de libertad (6D) usando únicamente la entrada de una cámara estéreo a bordo del UAV. Un método Semi-Global Blocking Matching (SGBM) eficiente basado en una estrategia grueso-a-fino ha sido implementada para una rápida y profunda estimación del plano. Además, la solución toma provecho eficazmente de la información 2D y 3D para estimar la posición 6D, resolviendo de esta manera la limitación de un punto de referencia fijo en la cámara estéreo. Una robusta aproximación volumétrica de mapping basada en el framework Octomap ha sido utilizada para reconstruir entornos cerrados y al aire libre bastante abarrotados en 3D con memoria y errores correlacionados espacialmente o temporalmente; (III) visual control, ofrece soluciones de control prácticas para la navegación de un UAV usando Fuzzy Logic Controller (FLC) con la estimación visual. Y el framework de Cross-Entropy Optimization (CEO) ha sido usado para optimizar el factor de escala y la función de pertenencia en FLC. Todas las soluciones basadas en visión en este trabajo han sido probadas en test reales. Y los conjuntos de datos de imágenes reales grabados en estos test o disponibles para la comunidad pública han sido utilizados para evaluar el rendimiento de estas soluciones basadas en visión con ground truth. Además, las soluciones de visión presentadas han sido comparadas con algoritmos de visión del estado del arte. Los test reales y los resultados de evaluación muestran que las soluciones basadas en visión proporcionadas han obtenido rendimientos en tiempo real precisos y robustos, o han alcanzado un mejor rendimiento que aquellos algoritmos del estado del arte. La estimación basada en visión ha ganado un rol muy importante en controlar un UAV típico para alcanzar autonomía en aplicaciones UAV. ABSTRACT The main objective of this dissertation is providing real-time accurate robust monocular or stereo vision-based solution for Unmanned Aerial Vehicle (UAV) to achieve the autonomy in various types of UAV applications, especially in GPS-denied dynamic cluttered environments. This dissertation mainly consists of three UAV research topics based on computer vision technique: (I) visual tracking, it supplys effective solutions to visually locate interesting static or moving object over time during UAV flight with on-line adaptivity approach and multiple-resolution strategy, thereby overcoming the problems generated by the different challenging situations, such as significant appearance change, variant surrounding illumination, cluttered tracking background, partial or full object occlusion, rapid pose variation and onboard mechanical vibration. The solutions have been utilized in autonomous landing, offshore floating platform inspection and midair aircraft tracking for sense-and-avoid; (II) visual odometry: it provides the efficient solution for UAV to estimate the 6 Degree-of-freedom (6D) pose using only the input of stereo camera onboard UAV. An efficient Semi-Global Blocking Matching (SGBM) method based on a coarse-to-fine strategy has been implemented for fast depth map estimation. In addition, the solution effectively takes advantage of both 2D and 3D information to estimate the 6D pose, thereby solving the limitation of a fixed small baseline in the stereo camera. A robust volumetric occupancy mapping approach based on the Octomap framework has been utilized to reconstruct indoor and outdoor large-scale cluttered environments in 3D with less temporally or spatially correlated measurement errors and memory; (III) visual control, it offers practical control solutions to navigate UAV using Fuzzy Logic Controller (FLC) with the visual estimation. And the Cross-Entropy Optimization (CEO) framework has been used to optimize the scaling factor and the membership function in FLC. All the vision-based solutions in this dissertation have been tested in real tests. And the real image datasets recorded from these tests or available from public community have been utilized to evaluate the performance of these vision-based solutions with ground truth. Additionally, the presented vision solutions have compared with the state-of-art visual algorithms. Real tests and evaluation results show that the provided vision-based solutions have obtained real-time accurate robust performances, or gained better performance than those state-of-art visual algorithms. The vision-based estimation has played a critically important role for controlling a typical UAV to achieve autonomy in the UAV application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The more and more demanding conditions in the power generation sector requires to apply all the available technologies to optimize processes and reduce costs. An integrated asset management strategy, combining technical analysis and operation and maintenance management can help to improve plant performance, flexibility and reliability. In order to deploy such a model it is necessary to combine plant data and specific equipment condition information, with different systems devoted to analyze performance and equipment condition, and take advantage of the results to support operation and maintenance decisions. This model that has been dealt in certain detail for electricity transmission and distribution networks, is not yet broadly extended in the power generation sector, as proposed in this study for the case of a combined power plant. Its application would turn in direct benefit for the operation and maintenance and for the interaction to the energy market

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los Centros de Datos se encuentran actualmente en cualquier sector de la economía mundial. Están compuestos por miles de servidores, dando servicio a los usuarios de forma global, las 24 horas del día y los 365 días del año. Durante los últimos años, las aplicaciones del ámbito de la e-Ciencia, como la e-Salud o las Ciudades Inteligentes han experimentado un desarrollo muy significativo. La necesidad de manejar de forma eficiente las necesidades de cómputo de aplicaciones de nueva generación, junto con la creciente demanda de recursos en aplicaciones tradicionales, han facilitado el rápido crecimiento y la proliferación de los Centros de Datos. El principal inconveniente de este aumento de capacidad ha sido el rápido y dramático incremento del consumo energético de estas infraestructuras. En 2010, la factura eléctrica de los Centros de Datos representaba el 1.3% del consumo eléctrico mundial. Sólo en el año 2012, el consumo de potencia de los Centros de Datos creció un 63%, alcanzando los 38GW. En 2013 se estimó un crecimiento de otro 17%, hasta llegar a los 43GW. Además, los Centros de Datos son responsables de más del 2% del total de emisiones de dióxido de carbono a la atmósfera. Esta tesis doctoral se enfrenta al problema energético proponiendo técnicas proactivas y reactivas conscientes de la temperatura y de la energía, que contribuyen a tener Centros de Datos más eficientes. Este trabajo desarrolla modelos de energía y utiliza el conocimiento sobre la demanda energética de la carga de trabajo a ejecutar y de los recursos de computación y refrigeración del Centro de Datos para optimizar el consumo. Además, los Centros de Datos son considerados como un elemento crucial dentro del marco de la aplicación ejecutada, optimizando no sólo el consumo del Centro de Datos sino el consumo energético global de la aplicación. Los principales componentes del consumo en los Centros de Datos son la potencia de computación utilizada por los equipos de IT, y la refrigeración necesaria para mantener los servidores dentro de un rango de temperatura de trabajo que asegure su correcto funcionamiento. Debido a la relación cúbica entre la velocidad de los ventiladores y el consumo de los mismos, las soluciones basadas en el sobre-aprovisionamiento de aire frío al servidor generalmente tienen como resultado ineficiencias energéticas. Por otro lado, temperaturas más elevadas en el procesador llevan a un consumo de fugas mayor, debido a la relación exponencial del consumo de fugas con la temperatura. Además, las características de la carga de trabajo y las políticas de asignación de recursos tienen un impacto importante en los balances entre corriente de fugas y consumo de refrigeración. La primera gran contribución de este trabajo es el desarrollo de modelos de potencia y temperatura que permiten describes estos balances entre corriente de fugas y refrigeración; así como la propuesta de estrategias para minimizar el consumo del servidor por medio de la asignación conjunta de refrigeración y carga desde una perspectiva multivariable. Cuando escalamos a nivel del Centro de Datos, observamos un comportamiento similar en términos del balance entre corrientes de fugas y refrigeración. Conforme aumenta la temperatura de la sala, mejora la eficiencia de la refrigeración. Sin embargo, este incremente de la temperatura de sala provoca un aumento en la temperatura de la CPU y, por tanto, también del consumo de fugas. Además, la dinámica de la sala tiene un comportamiento muy desigual, no equilibrado, debido a la asignación de carga y a la heterogeneidad en el equipamiento de IT. La segunda contribución de esta tesis es la propuesta de técnicas de asigación conscientes de la temperatura y heterogeneidad que permiten optimizar conjuntamente la asignación de tareas y refrigeración a los servidores. Estas estrategias necesitan estar respaldadas por modelos flexibles, que puedan trabajar en tiempo real, para describir el sistema desde un nivel de abstracción alto. Dentro del ámbito de las aplicaciones de nueva generación, las decisiones tomadas en el nivel de aplicación pueden tener un impacto dramático en el consumo energético de niveles de abstracción menores, como por ejemplo, en el Centro de Datos. Es importante considerar las relaciones entre todos los agentes computacionales implicados en el problema, de forma que puedan cooperar para conseguir el objetivo común de reducir el coste energético global del sistema. La tercera contribución de esta tesis es el desarrollo de optimizaciones energéticas para la aplicación global por medio de la evaluación de los costes de ejecutar parte del procesado necesario en otros niveles de abstracción, que van desde los nodos hasta el Centro de Datos, por medio de técnicas de balanceo de carga. Como resumen, el trabajo presentado en esta tesis lleva a cabo contribuciones en el modelado y optimización consciente del consumo por fugas y la refrigeración de servidores; el modelado de los Centros de Datos y el desarrollo de políticas de asignación conscientes de la heterogeneidad; y desarrolla mecanismos para la optimización energética de aplicaciones de nueva generación desde varios niveles de abstracción. ABSTRACT Data centers are easily found in every sector of the worldwide economy. They consist of tens of thousands of servers, serving millions of users globally and 24-7. In the last years, e-Science applications such e-Health or Smart Cities have experienced a significant development. The need to deal efficiently with the computational needs of next-generation applications together with the increasing demand for higher resources in traditional applications has facilitated the rapid proliferation and growing of data centers. A drawback to this capacity growth has been the rapid increase of the energy consumption of these facilities. In 2010, data center electricity represented 1.3% of all the electricity use in the world. In year 2012 alone, global data center power demand grew 63% to 38GW. A further rise of 17% to 43GW was estimated in 2013. Moreover, data centers are responsible for more than 2% of total carbon dioxide emissions. This PhD Thesis addresses the energy challenge by proposing proactive and reactive thermal and energy-aware optimization techniques that contribute to place data centers on a more scalable curve. This work develops energy models and uses the knowledge about the energy demand of the workload to be executed and the computational and cooling resources available at data center to optimize energy consumption. Moreover, data centers are considered as a crucial element within their application framework, optimizing not only the energy consumption of the facility, but the global energy consumption of the application. The main contributors to the energy consumption in a data center are the computing power drawn by IT equipment and the cooling power needed to keep the servers within a certain temperature range that ensures safe operation. Because of the cubic relation of fan power with fan speed, solutions based on over-provisioning cold air into the server usually lead to inefficiencies. On the other hand, higher chip temperatures lead to higher leakage power because of the exponential dependence of leakage on temperature. Moreover, workload characteristics as well as allocation policies also have an important impact on the leakage-cooling tradeoffs. The first key contribution of this work is the development of power and temperature models that accurately describe the leakage-cooling tradeoffs at the server level, and the proposal of strategies to minimize server energy via joint cooling and workload management from a multivariate perspective. When scaling to the data center level, a similar behavior in terms of leakage-temperature tradeoffs can be observed. As room temperature raises, the efficiency of data room cooling units improves. However, as we increase room temperature, CPU temperature raises and so does leakage power. Moreover, the thermal dynamics of a data room exhibit unbalanced patterns due to both the workload allocation and the heterogeneity of computing equipment. The second main contribution is the proposal of thermal- and heterogeneity-aware workload management techniques that jointly optimize the allocation of computation and cooling to servers. These strategies need to be backed up by flexible room level models, able to work on runtime, that describe the system from a high level perspective. Within the framework of next-generation applications, decisions taken at this scope can have a dramatical impact on the energy consumption of lower abstraction levels, i.e. the data center facility. It is important to consider the relationships between all the computational agents involved in the problem, so that they can cooperate to achieve the common goal of reducing energy in the overall system. The third main contribution is the energy optimization of the overall application by evaluating the energy costs of performing part of the processing in any of the different abstraction layers, from the node to the data center, via workload management and off-loading techniques. In summary, the work presented in this PhD Thesis, makes contributions on leakage and cooling aware server modeling and optimization, data center thermal modeling and heterogeneityaware data center resource allocation, and develops mechanisms for the energy optimization for next-generation applications from a multi-layer perspective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El trabajo contenido en esta tesis doctoral está encuadrado en el desarrollo de antenas reconfigurables electrónicamente capaces de proporcionar prestaciones competitivas a las aplicaciones cada vez más comunes que operan a frecuencias superiores a 60 GHz. En concreto, esta tesis se centra en el estudio, diseño, e implementación de las antenas reflectarray, a las que se introduce la tecnología de cristal líquido como elemento característico con el que se consigue reconfigurabilidad de haz de forma electrónica. Desde un punto de vista muy general, se puede describir un cristal líquido como un material cuya permitividad eléctrica es variable y controlada por una excitación externa, que generalmente suele corresponderse con un campo eléctrico quasi-estático (AC). Las antenas reflectarray de cristal líquido se han escogido como objeto de estudio por varias razones. La primera de ellas tiene que ver con las ventajas que los reflectarrays, y en especial aquellos realizados en configuración planar, proporcionan con respecto a otras antenas de alta ganancia como los reflectores o los “phased-arrays”. En los reflectarrays, la alimentación a través de una fuente primaria común (característica de reflectores) y el elevado número de grados de libertad de las celdas que los componen (característica de arrays) hacen que estas antenas puedan proporcionar prestaciones eléctricas iguales o mejores que las anteriores, a un coste más reducido y con estructuras de antena más compactas. La segunda razón radica en la flexibilidad que ofrece el cristal líquido a ser confinado y polarizado en recintos de geometría variada, como consecuencia de su fluidez (propiedad de los líquidos). Por ello, la tecnología de cristal líquido permite que el propio elemento reconfigurable en las celdas de reflectarray se adapte a la configuración planar de manera que en sí mismo, el cristal líquido sea una o varias de las capas características de esta configuración. Esto simplifica de forma drástica la estructura y la fabricación de este tipo de antenas, incluso si se comparan con reflectarrays reconfigurables basados en otras tecnologías como diodos, MEMS, etc. Por tanto, su coste y desarrollo es muy reducido, lo que hace que se puedan fabricar reflectarrays reconfigurables eléctricamente grandes, a bajo coste, y en producción elevada. Un ejemplo claro de una estructura similar, y que ha tenido éxito comercial, son las pantallas de cristal líquido. La tercera razón reside en el hecho de que el cristal líquido es, hasta la fecha, de las pocas tecnologías capaces de ofrecer reconfigurabilidad del haz a frecuencias superiores a 60 GHz. De hecho, el cristal líquido permite reconfigurabilidad en un amplio margen de frecuencias, que va desde DC a frecuencias del espectro visible, incluyendo las microondas y los THz. Otras tecnologías, como los materiales ferroeléctricos, el grafeno o la tecnología CMOS “on chip” permiten también conmutar el haz en estas frecuencias. Sin embargo, la tecnología CMOS tiene un elevado coste y actualmente está limitada a frecuencias inferiores a 150 GHz, y aunque los materiales ferroeléctricos o el grafeno puedan conmutar a frecuencias más altas y en un rango más amplio, tienen serias dificultades que los hacen aún inmaduros. En el caso de los materiales ferroeléctricos, los elevados voltajes para conmutar el material los hacen poco atractivos, mientras que en el caso del grafeno, su modelado aún está en discusión, y todavía no se han arrojado resultados experimentales que validen su idoneidad. Estas tres razones hacen que los reflectarrays basados en cristal líquido sean atractivos para multitud de aplicaciones de haz reconfigurable a frecuencias superiores a 60 GHz. Aplicaciones como radar de escaneo de imágenes de alta resolución, espectroscopia molecular, radiómetros para observación atmosférica, o comunicaciones inalámbricas de alta frecuencia (WiGig) son algunas de ellas. La tesis está estructurada en tres partes. En la primera de ellas se describen las características más comunes de los cristales líquidos, centrándonos en detalle en aquellas propiedades ofrecidas por este material en fase nemática. En concreto, se estudiará la anisotropía dieléctrica (Ae) de los cristales líquidos uniaxiales, que son los que se emplean en esta tesis, definida como la diferencia entre la permitividad paralela (£//) y la perpendicular (e±): Ae = e,, - e±. También se estudiará la variación de este parámetro (Ae) con la frecuencia, y el modelado electromagnético macroscópico más general que, extraído a partir de aquella, permite describir el cristal líquido para cada tensión de polarización en celdas de geometría planar. Este modelo es de suma importancia para garantizar precisión en el desfasaje proporcionado por las diferentes celdas reconfigurables para reflectarrays que se describirán en la siguiente parte de la tesis. La segunda parte de la tesis se centra en el diseño de celdas reflectarray resonantes basadas en cristal líquido. La razón por la que se escogen estos tipos de celdas reside en el hecho de que son las únicas capaces de proporcionar rangos de fase elevados ante la reducida anisotropía dieléctrica que ofrecen los cristales líquidos. El objetivo de esta parte trata, por tanto, de obtener estructuras de celdas reflectarray que sean capaces de proporcionar buenas prestaciones eléctricas a nivel de antena, mejorando sustancialmente las prestaciones de las celdas reportadas en el estado del arte, así como de desarrollar una herramienta de diseño general para aquellas. Para ello, se estudian las prestaciones eléctricas de diferentes tipos de elementos resonantes de cristal líquido que van, desde el más sencillo, que ha limitado el estado de la técnica hasta el desarrollo de esta tesis y que está formado por un sólo resonador, a elementos que constan de varios resonadores (multi-resonantes) y que pueden ser monocapa o multicapa. En un primer paso, el procedimiento de diseño de estas estructuras hace uso de un modelo convencional de cristal líquido que ha venido siendo usado en el estado del arte para este tipo de celdas, y que considera el cristal líquido como un material homogéneo e isótropo cuya permitividad varía entre (e/7) y (e±). Sin embargo, en esta parte de la tesis se demuestra que dicho modelado no es suficiente para describir de forma genérica el comportamiento del cristal líquido en las celdas tipo reflectarray. En la tesis se proponen procedimientos más exactos para el análisis y diseño basados en un modelo más general que define el cristal líquido como un material anisótropo e inhomogeneo en tres dimensiones, y se ha implementado una técnica que permite optimizar celdas multi-resonantes de forma eficiente para conseguir elevadas prestaciones en cuanto a ancho de banda, rango de fase, pérdidas, o sensibilidad al ángulo de incidencia. Los errores cometidos en el uso del modelado convencional a nivel de celda (amplitud y fase) se han analizado para varias geometrías, usando medidas de varios prototipos de antena que usan un cristal líquido real a frecuencias superiores a 100 GHz. Las medidas se han realizado en entorno periódico mediante un banco cuasi-óptico, que ha sido diseñado especialmente para este fin. Uno de estos prototipos se ha optimizado a 100 GHz para conseguir un ancho de banda relativamente elevado (10%), pérdidas reducidas, un rango de fase mayor de 360º, baja sensibilidad al ángulo de incidencia, y baja influencia de la inhomogeneidad transversal del cristal líquido en la celda. Estas prestaciones a nivel de celda superan de forma clara aquellas conseguidas por otros elementos que se han reportado en la literatura, de manera que dicho prototipo se ha usado en la última parte de la tesis para realizar diversas antenas de barrido. Finalmente, en esta parte se presenta una estrategia de caracterización de la anisotropía macroscópica a partir de medidas de los elementos de reflectarray diseñados en banco cuasi-óptico, obteniendo resultados tanto en las frecuencias de interés en RF como en AC, y comparándolas con aquellas obtenidas mediante otros métodos. La tercera parte de la tesis consiste en el estudio, diseño, fabricación y medida de antenas reconfigurables basadas en cristal líquido en configuraciones complejas. En reflectarrays pasivos, el procedimiento de diseño de la antena se limita únicamente al ajuste en cada celda de la antena de las dimensiones de las metalizaciones que se emplean para el control de fase, mediante procesos de optimización bien conocidos. Sin embargo, en el caso de reflectarrays reconfigurables basados en cristal líquido, resulta necesario un paso adicional, que consiste en calcular de forma adecuada las tensiones de control en cada celda del reflectarray para configurar la fase requerida en cada una de ellas, así como diseñar la estructura y los circuitos de control que permitan direccionar a cada elemento su tensión correspondiente. La síntesis de tensiones es por tanto igual o más importante que el diseño de la geometría de las celdas, puesto que éstas son las que están directamente relacionadas con la fase. En el estado del arte, existen varias estrategias de síntesis de tensiones que se basan en la caracterización experimental de la curva de fase respecto al voltaje. Sin embargo, esta caracterización sólo puede hacerse a un solo ángulo de incidencia y para unas determinadas dimensiones de celda, lo que produce que las tensiones sintetizadas sean diferentes de las adecuadas, y en definitiva que se alcancen errores de fase mayores de 70º. De esta forma, hasta la fecha, las prestaciones a nivel de antena que se han conseguido son reducidas en cuanto a ancho de banda, rango de escaneo o nivel de lóbulos secundarios. En esta última parte de la tesis, se introduce una nueva estrategia de síntesis de tensiones que es capaz de predecir mediante simulaciones, y con alta precisión, las tensiones que deben introducirse en cada celda teniendo en cuenta su ángulo de incidencia, sus dimensiones, la frecuencia, así como la señal de polarización definida por su frecuencia y forma de onda AC. Esta estrategia se basa en modelar cada uno de los estados de permitividad del cristal líquido como un sustrato anisótropo con inhomogeneidad longitudinal (1D), o en ciertos casos, como un tensor equivalente homogéneo. La precisión de ambos modelos electromagnéticos también se discute. Con el objetivo de obtener una herramienta eficiente de cálculo de tensiones, también se ha escrito e implementado una herramienta de análisis basada en el Método de los Momentos en el Dominio Espectral (SD-MoM) para sustratos estratificados anisótropos, que se usa en cada iteración del procedimiento de síntesis para analizar cada una de las celdas de la antena. La síntesis de tensiones se ha diseñado además para reducir al máximo el efecto del rizado de amplitud en el diagrama de radiación, que es característico en los reflectarrays que están formados por celdas con pérdidas elevadas, lo que en sí, supone un avance adicional para la obtención de mejores prestaciones de antena. Para el cálculo de los diagramas de radiación empleados en el procedimiento de síntesis, se asume un análisis elemento a elemento considerando periodicidad local, y se propone el uso de un método capaz de modelar el campo incidente de forma que se elimine la limitación de la periodicidad local en la excitación. Una vez definida la estrategia adecuada de cálculo de las tensiones a aplicar al cristal líquido en cada celda, la estructura de direccionamiento de las mismas en la antena, y diseñados los circuitos de control, se diseñan, fabrican y miden dos prototipos diferentes de antena de barrido electrónico a 100 GHz usando las celdas anteriormente presentadas. El primero de estos prototipos es un reflectarray en configuración “single offset” con capacidad de escaneo en un plano (elevación o azimut). Aunque previamente se realizan diseños de antenas de barrido en 2D a varias frecuencias en el rango de milimétricas y sub-milimétricas, y se proponen ciertas estrategias de direccionamiento que permiten conseguir este objetivo, se desarrolla el prototipo con direccionamiento en una dimensión con el fin de reducir el número de controles y posibles errores de fabricación, y así también validar la herramienta de diseño. Para un tamaño medio de apertura (con un numero de filas y columnas entre 30 y 50 elementos, lo que significa un reflectarray con un número de elementos superior a 900), la configuración “single offset” proporciona rangos de escaneo elevados, y ganancias que pueden oscilar entre los 20 y 30 dBi. En concreto, el prototipo medido proporciona un haz de barrido en un rango angular de 55º, en el que el nivel de lóbulos secundarios (SLL) permanece mejor de -13 dB en un ancho de banda de un 8%. La ganancia máxima es de 19.4 dBi. Estas prestaciones superan de forma clara aquellas conseguidas por otros autores. El segundo prototipo se corresponde con una antena de doble reflector que usa el reflectarray de cristal líquido como sub-reflector para escanear el haz en un plano (elevación o azimut). El objetivo básico de esta geometría es obtener mayores ganancias que en el reflectarray “single offset” con una estructura más compacta, aunque a expensas de reducir el rango de barrido. En concreto, se obtiene una ganancia máxima de 35 dBi, y un rango de barrido de 12º. Los procedimientos de síntesis de tensiones y de diseño de las estructuras de las celdas forman, en su conjunto, una herramienta completa de diseño precisa y eficiente de antenas reflectarray reconfigurables basados en cristales líquidos. Dicha herramienta se ha validado mediante el diseño, la fabricación y la medida de los prototipos anteriormente citados a 100 GHz, que consiguen algo nunca alcanzado anteriormente en la investigación de este tipo de antenas: unas prestaciones competitivas y una predicción excelente de los resultados. El procedimiento es general, y por tanto se puede usar a cualquier frecuencia en la que el cristal líquido ofrezca anisotropía dieléctrica, incluidos los THz. Los prototipos desarrollados en esta tesis doctoral suponen también unas de las primeras antenas de barrido real a frecuencias superiores a 100 GHz. En concreto, la antena de doble reflector para escaneo de haz es la primera antena reconfigurable electrónicamente a frecuencias superiores a 60 GHz que superan los 25 dBi de ganancia, siendo a su vez la primera antena de doble reflector que contiene un reflectarray reconfigurable como sub-reflector. Finalmente, se proponen ciertas mejoras que aún deben se deben realizar para hacer que estas antenas puedan ser un producto completamente desarrollado y competitivo en el mercado. ABSTRACT The work presented in this thesis is focused on the development of electronically reconfigurable antennas that are able to provide competitive electrical performance to the increasingly common applications operating at frequencies above 60 GHz. Specifically, this thesis presents the study, design, and implementation of reflectarray antennas, which incorporate liquid crystal (LC) materials to scan or reconfigure the beam electronically. From a general point of view, a liquid crystal can be defined as a material whose dielectric permittivity is variable and can be controlled with an external excitation, which usually corresponds with a quasi-static electric field (AC). By changing the dielectric permittivity at each cell that makes up the reflectarray, the phase shift on the aperture is controlled, so that a prescribed radiation pattern can be configured. Liquid Crystal-based reflectarrays have been chosen for several reasons. The first has to do with the advantages provided by the reflectarray antenna with respect to other high gain antennas, such as reflectors or phased arrays. The RF feeding in reflectarrays is achieved by using a common primary source (as in reflectors). This arrangement and the large number of degrees of freedom provided by the cells that make up the reflectarray (as in arrays), allow these antennas to provide a similar or even better electrical performance than other low profile antennas (reflectors and arrays), but assuming a more reduced cost and compactness. The second reason is the flexibility of the liquid crystal to be confined in an arbitrary geometry due to its fluidity (property of liquids). Therefore, the liquid crystal is able to adapt to a planar geometry so that it is one or more of the typical layers of this configuration. This simplifies drastically both the structure and manufacture of this type of antenna, even when compared with reconfigurable reflectarrays based on other technologies, such as diodes MEMS, etc. Therefore, the cost of developing this type of antenna is very small, which means that electrically large reconfigurable reflectarrays could be manufactured assuming low cost and greater productions. A paradigmatic example of a similar structure is the liquid crystal panel, which has already been commercialized successfully. The third reason lies in the fact that, at present, the liquid crystal is one of the few technologies capable of providing switching capabilities at frequencies above 60 GHz. In fact, the liquid crystal allows its permittivity to be switched in a wide range of frequencies, which are from DC to the visible spectrum, including microwaves and THz. Other technologies, such as ferroelectric materials, graphene or CMOS "on chip" technology also allow the beam to be switched at these frequencies. However, CMOS technology is expensive and is currently limited to frequencies below 150 GHz, and although ferroelectric materials or graphene can switch at higher frequencies and in a wider range, they have serious difficulties that make them immature. Ferroelectric materials involve the use of very high voltages to switch the material, making them unattractive, whereas the electromagnetic modelling of the graphene is still under discussion, so that the experimental results of devices based on this latter technology have not been reported yet. These three reasons make LC-based reflectarrays attractive for many applications that involve the use of electronically reconfigurable beams at frequencies beyond 60 GHz. Applications such as high resolution imaging radars, molecular spectroscopy, radiometers for atmospheric observation, or high frequency wireless communications (WiGig) are just some of them. This thesis is divided into three parts. In the first part, the most common properties of the liquid crystal materials are described, especially those exhibited in the nematic phase. The study is focused on the dielectric anisotropy (Ac) of uniaxial liquid crystals, which is defined as the difference between the parallel (e/7) and perpendicular (e±) permittivities: Ae = e,, - e±. This parameter allows the permittivity of a LC confined in an arbitrary volume at a certain biasing voltage to be described by solving a variational problem that involves both the electrostatic and elastic energies. Thus, the frequency dependence of (Ae) is also described and characterised. Note that an appropriate LC modelling is quite important to ensure enough accuracy in the phase shift provided by each cell that makes up the reflectarray, and therefore to achieve a good electrical performance at the antenna level. The second part of the thesis is focused on the design of resonant reflectarray cells based on liquid crystal. The reason why resonant cells have been chosen lies in the fact that they are able to provide enough phase range using the values of the dielectric anisotropy of the liquid crystals, which are typically small. Thus, the aim of this part is to investigate several reflectarray cell architectures capable of providing good electrical performance at the antenna level, which significantly improve the electrical performance of the cells reported in the literature. Similarly, another of the objectives is to develop a general tool to design these cells. To fulfill these objectives, the electrical yields of different types of resonant reflectarray elements are investigated, beginning from the simplest, which is made up of a single resonator and limits the state of the art. To overcome the electrical limitations of the single resonant cell, several elements consisting of multiple resonators are considered, which can be single-layer or multilayer. In a first step, the design procedure of these structures makes use of a conventional electromagnetic model which has been used in the literature, which considers that the liquid crystal behaves as homogeneous and isotropic materials whose permittivity varies between (e/7) y (e±). However, in this part of the thesis it is shown that the conventional modelling is not enough to describe the physical behaviour of the liquid crystal in reflectarray cells accurately. Therefore, a more accurate analysis and design procedure based on a more general model is proposed and developed, which defines the liquid crystal as an anisotropic three-dimensional inhomogeneous material. The design procedure is able to optimize multi-resonant cells efficiently to achieve good electrical performance in terms of bandwidth, phase range, losses, or sensitivity to the angle of incidence. The errors made when the conventional modelling (amplitude and phase) is considered have been also analysed for various cell geometries, by using measured results from several antenna prototypes made up of real liquid crystals at frequencies above 100 GHz. The measurements have been performed in a periodic environment using a quasi-optical bench, which has been designed especially for this purpose. One of these prototypes has been optimized to achieve a relatively large bandwidth (10%) at 100 GHz, low losses, a phase range of more than 360º, a low sensitivity to angle of incidence, and a low influence of the transversal inhomogeneity of the liquid crystal in the cell. The electrical yields of this prototype at the cell level improve those achieved by other elements reported in the literature, so that this prototype has been used in the last part of the thesis to perform several complete antennas for beam scanning applications. Finally, in this second part of the thesis, a novel strategy to characterise the macroscopic anisotropy using reflectarray cells is presented. The results in both RF and AC frequencies are compared with those obtained by other methods. The third part of the thesis consists on the study, design, manufacture and testing of LCbased reflectarray antennas in complex configurations. Note that the design procedure of a passive reflectarray antenna just consists on finding out the dimensions of the metallisations of each cell (which are used for phase control), using well-known optimization processes. However, in the case of reconfigurable reflectarrays based on liquid crystals, an additional step must be taken into account, which consists of accurately calculating the control voltages to be applied to each cell to configure the required phase-shift distribution on the surface of the antenna. Similarly, the structure to address the voltages at each cell and the control circuitry must be also considered. Therefore, the voltage synthesis is even more important than the design of the cell geometries (dimensions), since the voltages are directly related to the phase-shift. Several voltage synthesis procedures have been proposed in the state of the art, which are based on the experimental characterization of the phase/voltage curve. However, this characterization can be only carried out at a single angle of incidence and at certain cell dimensions, so that the synthesized voltages are different from those needed, thus giving rise to phase errors of more than 70°. Thus, the electrical yields of the LCreflectarrays reported in the literature are limited in terms of bandwidth, scanning range or side lobes level. In this last part of the thesis, a new voltage synthesis procedure has been defined and developed, which allows the required voltage to be calculated at each cell using simulations that take into account the particular dimensions of the cells, their angles of incidence, the frequency, and the AC biasing signal (frequency and waveform). The strategy is based on the modelling of each one of the permittivity states of the liquid crystal as an anisotropic substrate with longitudinal inhomogeneity (1D), or in certain cases, as an equivalent homogeneous tensor. The accuracy of both electromagnetic models is also discussed. The phase errors made by using the proposed voltage synthesis are better than 7º. In order to obtain an efficient tool to analyse and design the reflectarray, an electromagnetic analysis tool based on the Method of Moments in the spectral domain (SD-MoM) has also written and developed for anisotropic stratified media, which is used at each iteration of the voltage synthesis procedure. The voltage synthesis is also designed to minimize the effect of amplitude ripple on the radiation pattern, which is typical of reflectarrays made up of cells exhibiting high losses and represents a further advance in achieving a better antenna performance. To calculate the radiation patterns used in the synthesis procedure, an element-by-element analysis is assumed, which considers the local periodicity approach. Under this consideration, the use of a novel method is proposed, which avoids the limitation that the local periodicity imposes on the excitation. Once the appropriate strategy to calculate the voltages to be applied at each cell is developed, and once it is designed and manufactured both the structure to address the voltages to the antenna and the control circuits, two complete LC-based reflectarray antennas that operate at 100 GHz have been designed, manufactured and tested using the previously presented cells. The first prototype consists of a single offset reflectarray with beam scanning capabilities on one plane (elevation and azimuth). Although several LC-reflectarray antennas that provide 2-D scanning capabilities are also designed, and certain strategies to achieve the 2-D addressing of the voltage are proposed, the manufactured prototype addresses the voltages in one dimension in order to reduce the number of controls and manufacturing errors, and thereby validating the design tool. For an average aperture size (with a number of rows and columns of between 30 and 50 elements, which means a reflectarray with more than 900 cells), the single offset configuration provides an antenna gain of between 20 and 30 dBi and a large scanning range. The prototype tested at 100 GHz exhibits an electronically scanned beam in an angular range of 55º and 8% of bandwidth, in which the side lobe level (SLL) remains better than -13 dB. The maximum gain is 19.4 dBi. The electrical performance of the antenna is clearly an improvement on those achieved by other authors in the state of the art. The second prototype corresponds to a dual reflector antenna with a liquid crystal-based reflectarray used as a sub-reflector for beam scanning in one plane (azimuth or elevation). The main objective is to obtain a higher gain than that provided by the single offset configuration, but using a more compact architecture. In this case, a maximum gain of 35 dBi is achieved, although at the expense of reducing the scanning range to 12°, which is inherent in this type of structure. As a general statement, the voltage synthesis and the design procedure of the cells, jointly make up a complete, accurate and efficient design tool of reconfigurable reflectarray antennas based on liquid crystals. The tool has been validated by testing the previously mentioned prototypes at 100 GHz, which achieve something never reached before for this type of antenna: a competitive electrical performance, and an excellent prediction of the results. The design procedure is general and therefore can be used at any frequency for which the liquid crystal exhibits dielectric anisotropy. The two prototypes designed, manufactured and tested in this thesis are also some of the first antennas that currently operate at frequencies above 100 GHz. In fact, the dual reflector antenna is the first electronically scanned dual reflector antenna at frequencies above 60 GHz (the operation frequency is 100 GHz) with a gain greater than 25 dBi, being in turn the first dual-reflector antenna with a real reconfigurable sub-reflectarray. Finally, some improvements that should be still investigated to make these antennas commercially competitive are proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El objetivo general de esta Tesis Doctoral fue evaluar nuevos sistemas de alojamiento y cría de conejos de granja, estudiando tanto parámetros comportamentales (experimento 1) como productivos y reproductivos (experimento 3). Además, se evaluaron diferentes técnicas de muestreo con el fin de optimizar el tiempo empleado para el estudio del comportamiento animal (experimento 2). En el experimento 1, se estudió el comportamiento de conejas alojadas en dos tipos de jaulas (TJ), convencionales vs. alternativas con una plataforma elevada, en distintos estados fisiológicos (EF), lactantes y gestantes. Se observó el comportamiento de 12 conejas reproductoras con grabaciones de una duración de 24 h continuas. Independientemente del EF y TJ, las conejas pasaron gran parte de su tiempo sobre el reposapatas (57,7 %, de media). Sin embargo, debido al uso de la plataforma (23,0% del tiempo, de media), las conejas lactantes permanecieron un 36,6 % menos de tiempo (P<0,001) sobre el reposapatas y las gestantes un 27,0% menos (P<0,001) sobre el enrejillado en jaulas alternativas que en convencionales. En las jaulas alternativas, las conejas podían adoptar la postura “levantada”, sin embargo ésta fue observada solamente en conejas gestantes una media de 4,6 veces al día. Las conejas bebieron con mas frecuencia en jaulas convencionales que en alternativas (24,6 vs 19,1 veces al día; P<0,05). Se observó una mayor duración y frecuencia del comportamiento “interactuando con compañeras” en conejas gestantes alojadas en jaulas convencionales (276 s/d y 4,6 veces/d; P<0,05). La frecuencia de “interactuando con gazapos” fue menor en jaulas alternativas que en convencionales (2,4 vs 8,6 veces al día; P<0,01). La hora del día afectó al comportamiento de las conejas, teniendo un comportamiento menos activo durante las horas centrales del día. Durante las horas de oscuridad, las conejas estuvieron más inquietas realizando comportamientos como ‘encabritarse’ o amamantar, coincidiendo éstos en el tiempo en el cual las conejas pasaron más tiempo en la plataforma. Las conejas utilizaron frecuentemente la plataforma, independientemente del estado fisiológico. En la fase de lactación, las conejas utilizaron la plataforma para huir de los intentos de mamar por parte de los gazapos cuando éstas no estaban receptivas. El uso de la plataforma puede dar lugar a problemas higiénicos debidos tanto por la acumulación de heces sobre ella como por la caída de heces y orina sobre los animales que están en la parte inferior. La ausencia de estereotipias por parte de las conejas tanto en jaulas alternativas como en convencionales no sugiere una falta de bienestar debida al sistema de alojamiento. En el experimento 2, se compararon distintos métodos de observación simplificada con respecto un método de referencia usando grabaciones continuas de 24 h para la evaluación del comportamiento de conejas en distintos estados fisiológicos (gestantes y lactantes) alojadas en dos tipos de jaulas (convencionales y alternativas). Se analizaron un total de 576 h de grabaciones continuas de 24 h en 12 conejas reproductoras al final del periodo de lactación y en las mismas conejas después del destete. Los comportamientos observados se clasificaron en tres categorías independientes (localización en la jaula, postura y comportamientos funcionales). Se utilizaron grabaciones continuas de 24 h como método de referencia para validar otros cuatro métodos de observación simplificados, utilizando grabaciones de distinta duración y frecuencia a lo largo del día. Métodos regulares: corto y largo con 2.4 y 8 h de observación respectivamente, y métodos irregulares: corto y largo con 6 y 8 h de observación, respectivamente. Como resultado, se observó que independientemente del sistema de alojamiento, el mejor método para reducir el tiempo de observación necesario para evaluar el comportamiento de conejas reproductoras depende del tipo de variable a estudiar y del estado fisiológico de las conejas. En gestantes, los métodos irregulares no fueron adecuados para estimar comportamientos de larga duración tales como tumbada, sentada, descansando y acicalándose. Sin embargo, en ambos estados fisiológicos, los métodos regulares fueron precisos para los comportamientos de los grupos localización y postura y para comportamientos funcionales de larga duración. Por otro lado, los coeficientes de variación de los comportamientos poco frecuentes realizados principalmente durante el periodo de oscuridad fueron muy altos, y el método irregular largo obtuvo los menores errores de estimación para éstos comportamientos. En el experimento 3, se estudió el efecto de un uso combinado de lactaciones largas (hasta 46 días) con jaulas alternativas sobre los parámetros productivos y reproductivos de 104 conejas y sus camadas durante cinco ciclos reproductivos. La mitad de las conejas fueron alojadas en jaulas polivalentes convencionales (39 cm x 100 cm x 30 cm) y la otra mitad en jaulas polivalentes alternativas (39 cm x 100 cm x 60 cm), con una plataforma elevada. Dentro de cada grupo de alojamiento, la mitad de las conejas se destetaron a 32 días y la otra mitad a 46 días tras el parto. Las lactaciones más largas afectaron negativamente al peso (P<0,001), contenido en grasa y energía (P<0,05) de las conejas al final del periodo de lactación, pero éste efecto disminuyó con el número de partos. La fertilidad, prolificidad y la mortalidad de las conejas no fue afectada por la duración de la lactación. El destete tardío dio lugar a un mayor tamaño y peso de la camada al final del periodo de crecimiento (8,9 y 11,3 %, respectivamente) y a un menor índice de conversión por jaula durante el todo el periodo experimental (13,5 %) con respecto al destete convencional (P<0,001). Éstos resultados fueron paralelos a la menor mortalidad global (12,6 vs 17,6 %; P<0,05) observada en gazapos con destete tardío. Las diferencias en los parámetros productivos con las distintas edades al destete sólo fueron observadas en los ciclos con peor estado sanitario (tercer y quinto ciclo), en los cuales el destete tardío redujo la mortalidad. El tipo de jaula no afectó al peso de la coneja, condición corporal, mortalidad, fertilidad ni tamaño de camada durante los cinco primeros ciclos reproductivos. Sin embargo, el peso de la camada y el índice de conversión a los 21 días de edad fueron 4,2% mayor (P<0,001) y 5,0% menor (P<0,005) en animales alojados en jaulas alternativas que en jaulas convencionales. A día 59 las jaulas alternativas dieron lugar a camadas más pesadas (P<0,01); sin embargo, éste efecto fue influenciado por la densidad alcanzada en cada ciclo, ya que cuando la densidad de los animales fue menor que 40kg/m2 (tercer y quinto ciclo), el efecto del tipo de jaula sobre el peso de la camada no fue significativo. De los resultados obtenidos se puede concluir que el uso combinado de lactaciones más largas y jaulas con mayor superficie disponible con una plataforma elevada podría ser una alternativa para mejorar el bienestar animal en determinadas situaciones productivas. ABSTRACT The general aim of this PhD Thesis was to evaluate new housing and husbandry systems of farmed rabbits, studying behavioral (experiment 1), productive and reproductive (experiment 3) parameters. Moreover, different sampling techniques were evaluated in order to optimize the assessment of rabbit behaviour (experiment 2). In experiment 1, the behaviour of rabbit does housed in two different types of cage (TC), conventional vs. alternative with an elevated platform, at different physiological stages (PS), lactation and gestation was to study. Behavioural observations were carried out on 12 commercial rabbit does using continuous 24 hour video recording. Independently of PS and TC, rabbit does spent most of their time on foot mats (57.7 %, as average). However, due to the use of platforms (23.0% of time, as average), lactating does spent 36.6% less time (P<0.001) on foot mats and gestating does spent 27.0% less (P<0.001) time on wire mesh in alternative cages than in conventional cages. Alternative cages allowed for standing posture but this behaviour was only observed in gestating does (4.6 times a day, as average). Frequency of drinking was higher in conventional than in alternative cages (24.6 vs. 19.1 times a day; P<0.05). Gestating does housed in conventional cages reached the highest duration and frequency of interacting with neighbours (276 s/d and 4.6 times/d; P<0.05). The frequency of interacting with kits was lower in alternative than in conventional cages (2.4 vs. 8.6 times a day; P<0.01). Does’ behaviour was influenced by hour of day, being less active at the midday hours. During dark hours rabbit does more frequently performed restless behaviour such as hyperactivity or nursing, matching the time at which rabbit does spent more time on the platform. The platform was frequently used by rabbit does, independent of their physiological state, and during late lactation phase, when mothers were not receptive to nursing, does housed in alternative cages used the platform as a mean to flee from kids trying to suckle. The use of the platform might lead to hygienic problems due to retained faeces on the platform and faeces and urine falling onto animals located in the lower part of the cage. Stereotypies were not observed in any housing system, therefore conventional cages do not suggest lack of animal welfare. In experiment 2, it was compared the results of different simplified sampling methods of behavioural data with respect to reference records of 24-h in order to assess rabbit does behaviours at different physiological stages (gestation and lactation) in animals housed in two types of cages (conventional and alternative). A total of 576 h of continuous video of 12 rabbit does at the end of lactation and on the same females after weaning were analysed. The behavioural observations were studied using three independent categories of classification (location in the cage, posture and functional behaviours). Continuous behavioural recordings of 24 h were considered as the reference method to validate another 4 sampling methods of data collection by aggregated video recordings of different frequency and duration (regular short and long methods with 2.4 and 8 h of observation respectively, and irregular short and long methods with 6 and 8 h of observation, respectively). The current results showed that, independently of housing system, the best method to reduce the total observation time required to assess rabbit does behaviour depends on the trait studied and physiological stage of does. In gestating does, irregular methods were not suitable to estimate behaviours of long duration such as lying, sitting, resting and grooming. However, in both physiological stages, regular methods were accurate for location behaviours, postures and functional behaviours of long duration. Instead, for the study of infrequent behaviours performed mainly during dark period, where coefficients of variation were high, the irregular long method led to the lowest mean estimation errors. In experiment 3, the effects of the combined use of long lactation periods (46 days) with alternative cages on the reproductive and growth performance of 104 rabbit does and their litters during five consecutive reproductive cycles were studied. Half of does were housed in conventional polyvalent cages (39 cm x 100 cm x 30 cm) and the other half in alternative polyvalent cages (39 cm x 100 cm x 60 cm), with a raised platform. Half of the rabbit does in each type of cages were weaned at 32 and the other half at 46 days after parturition. Longer lactations affected negatively to body weight (P<0.001), fat and energy content (P<0.05) of rabbit does at the end of the lactation period, but this effect decreased with the number of parturitions. Fertility, prolificacy and doe mortality were not affected by lactation length. Late weaning led to higher litter size (by 8.9 %) and litter weight (by 11.3 %) at the end of growing period and lower feed conversion ratio per cage during the overall experimental period (13.5 %) than standard weaning (P<0.001). These results were parallels to a lower mortality (12.6 vs 17.6 %; P<0.05) of young rabbit weaned later during the overall experimental period. Differences in performances at different weaning ages were only observed during cycles with worst health status (third and fifth cycles) in which late weaning decreased mortality. Type of cage did not affect doe body weight and body condition, mortality, fertility, prolificacy and litter size during the five firsts reproductive cycles. Nevertheless, at day 21 litter weight and feed conversion ratio were 4.2 % higher (P<0.001) and 5.0 % lower (P<0.005) in animals housed in alternative than in conventional cages. Alternative cages also led to heavier litters at 59 days (P<0.01); however, this effect was influenced by density reached in each cycle, as when the density of animals was lower than 40 kg/m2 (cycles three and five), the difference of litter weight between alternative and conventional cages was not significant. From the results obtained it can be concluded that the combined use of longer lactations and cages with higher available surface with a raised platform could be an alternative to improve animal welfare in some productive situations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last few years, the Data Center market has increased exponentially and this tendency continues today. As a direct consequence of this trend, the industry is pushing the development and implementation of different new technologies that would improve the energy consumption efficiency of data centers. An adaptive dashboard would allow the user to monitor the most important parameters of a data center in real time. For that reason, monitoring companies work with IoT big data filtering tools and cloud computing systems to handle the amounts of data obtained from the sensors placed in a data center.Analyzing the market trends in this field we can affirm that the study of predictive algorithms has become an essential area for competitive IT companies. Complex algorithms are used to forecast risk situations based on historical data and warn the user in case of danger. Considering that several different users will interact with this dashboard from IT experts or maintenance staff to accounting managers, it is vital to personalize it automatically. Following that line of though, the dashboard should only show relevant metrics to the user in different formats like overlapped maps or representative graphs among others. These maps will show all the information needed in a visual and easy-to-evaluate way. To sum up, this dashboard will allow the user to visualize and control a wide range of variables. Monitoring essential factors such as average temperature, gradients or hotspots as well as energy and power consumption and savings by rack or building would allow the client to understand how his equipment is behaving, helping him to optimize the energy consumption and efficiency of the racks. It also would help him to prevent possible damages in the equipment with predictive high-tech algorithms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The phosphosilicate glass (PSG), fabricated by tube furnace diffusion using a POCl3 source, is widely used as a dopant source in the manufacturing of crystalline silicon solar cells. Although it has been a widely addressed research topic for a long time, there is still lack of a comprehensive understanding of aspects such as the growth, the chemical composition, possible phosphorus depletion, the resulting in-diffused phosphorus profiles, the gettering behavior in silicon, and finally the metal-contact formation. This paper addresses these different aspects simultaneously to further optimize process conditions for photovoltaic applications. To do so, a wide range of experimental data is used and combined with device and process simulations, leading to a more comprehensive interpretation. The results show that slight changes in the PSG process conditions can produce high-quality emitters. It is predicted that PSG processes at 860 °C for 60 min in combination with an etch-back and laser doping from PSG layer results in high-quality emitters with a peak dopant density Npeak = 8.0 × 1018 cm−3 and a junction depth dj = 0.4 μm, resulting in a sheet resistivityρsh = 380 Ω/sq and a saturation current-density J0 below 10 fA/cm2. With these properties, the POCl3 process can compete with ion implantation or doped oxide approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In general, a major challenge for the exploitation of renewable energies is to improve their efficiency. In electricity generation from the energy of ocean waves, not unlike other technologies, the converter must be optimized to make the energy harvesting economically feasible. This paper proposes a passive tuning control strategy of a point absorber in which the power captured is maximized by controlling the electromagnetic force of the generator with a resistance emulation approach. The proposed strategy consists of mapping the optimal values for regular waves and applying them to irregular waves. This strategy is tested in a wave energy converter in which the generator is connected to a boost rectifier converter whose controller is designed to emulate a resistance. The power electronics system implemented is validated by comparing its performance with the case in which the generator is directly connected to a resistive load. The simulation results show the effectiveness of the proposed strategy as the maximum captured power is concentrated around the optimal values previously calculated and with the same behavior for both excitations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Novel anti-neoplastic agents such as gene targeting vectors and encapsulated carriers are quite large (approximately 100–300 nm in diameter). An understanding of the functional size and physiological regulation of transvascular pathways is necessary to optimize delivery of these agents. Here we analyze the functional limits of transvascular transport and its modulation by the microenvironment. One human and five murine tumors including mammary and colorectal carcinomas, hepatoma, glioma, and sarcoma were implanted in the dorsal skin-fold chamber or cranial window, and the pore cutoff size, a functional measure of transvascular gap size, was determined. The microenvironment was modulated: (i) spatially, by growing tumors in subcutaneous or cranial locations and (ii) temporally, by inducing vascular regression in hormone-dependent tumors. Tumors grown subcutaneously exhibited a characteristic pore cutoff size ranging from 200 nm to 1.2 μm. This pore cutoff size was reduced in tumors grown in the cranium or in regressing tumors after hormone withdrawal. Vessels induced in basic fibroblast growth factor-containing gels had a pore cutoff size of 200 nm. Albumin permeability was independent of pore cutoff size. These results have three major implications for the delivery of therapeutic agents: (i) delivery may be less efficient in cranial tumors than in subcutaneous tumors, (ii) delivery may be reduced during tumor regression induced by hormonal ablation, and (iii) permeability to a molecule is independent of pore cutoff size as long as the diameter of the molecule is much less than the pore diameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Catalytic antibodies have shown great promise for catalyzing a tremendously diverse set of natural and unnatural chemical transformations. However, few catalytic antibodies have efficiencies that approach those of natural enzymes. In principle, random mutagenesis procedures such as phage display could be used to improve the catalytic activities of existing antibodies; however, these studies have been hampered by difficulties in the recombinant expression of antibodies. Here, we have grafted the antigen binding loops from a murine-derived catalytic antibody, 17E8, onto a human antibody framework in an effort to overcome difficulties associated with recombinant expression and phage display of this antibody. “Humanized” 17E8 retained similar catalytic and hapten binding properties as the murine antibody while levels of functional Fab displayed on phage were 200-fold higher than for a murine variable region/human constant region chimeric Fab. This construct was used to prepare combinatorial libraries. Affinity panning of these resulted in the selection of variants with 2- to 8-fold improvements in binding affinity for a phosphonate transition-state analog. Surprisingly, none of the affinity-matured variants was more catalytically active than the parent antibody and some were significantly less active. By contrast, a weaker binding variant was identified with 2-fold greater catalytic activity and incorporation of a single substitution (Tyr-100aH → Asn) from this variant into the parent antibody led to a 5-fold increase in catalytic efficiency. Thus, phage display methods can be readily used to optimize binding of catalytic antibodies to transition-state analogs, and when used in conjunction with limited screening for catalysis can identify variants with higher catalytic efficiencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is mounting evidence for the organization and compartmentation of signaling molecules at the plasma membrane. We find that hormone-sensitive adenylyl cyclase activity is enriched in a subset of regulatory G protein-containing fractions of the plasma membrane. These subfractions resemble, in low buoyant density, structures of the plasma membrane termed caveolae. Immunofluorescence experiments revealed a punctate pattern of G protein α and β subunits, consistent with concentration of these proteins at distinct sites on the plasma membrane. Partial coincidence of localization of G protein α subunits with caveolin (a marker for caveolae) was observed by double immunofluorescence. Results of immunogold electron microscopy suggest that some G protein is associated with invaginated caveolae, but most of the protein resides in irregular structures of the plasma membrane that could not be identified morphologically. Because regulated adenylyl cyclase activity is present in low-density subfractions of plasma membrane from a cell type (S49 lymphoma) that does not express caveolin, this protein is not required for organization of the adenylyl cyclase system. The data suggest that hormone-sensitive adenylyl cyclase systems are localized in a specialized subdomain of the plasma membrane that may optimize the efficiency and fidelity of signal transduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bacterial mutation rates can increase and produce genetic novelty, as shown by in vitro and in silico experiments. Despite the cost due to a heavy deleterious mutation load, mutator alleles, which increase the mutation rate, can spread in asexual populations during adaptation because they remain associated with the rare favorable mutations they generate. This indirect selection for a genetic system generating diversity (second-order selection) is expected to be highly sensitive to changes in the dynamics of adaptation. Here we show by a simulation approach that even rare genetic exchanges, such as bacterial conjugation or transformation, can dramatically reduce the selection of mutators. Moreover, drift or competition between the processes of mutation and recombination in the course of adaptation reveal how second-order selection is unable to optimize the rate of generation of novelty.