952 resultados para Fabrication method
Resumo:
Introduction QC, EQA and method evaluation are integral to delivery of quality patient results. To ensure QUT graduates have a solid grounding in these key areas of practice, a theory-to-practice approach is used to progressively develop and consolidate these skills. Methods Using a BCG assay for serum albumin, each student undertakes an eight week project analysing two levels of QC alongside ‘patient’ samples. Results are assessed using both single rules and Multirules. Concomitantly with the QC analyses, an EQA project is undertaken; students analyse two EQA samples, twice in the semester. Results are submitted using cloud software and data for the full ‘peer group’ returned to students in spreadsheets and incomplete Youden plots. Youden plots are completed with target values and calculated ALP values and analysed for ‘lab’ and method performance. The method has a low-level positive bias, which leads to the need to investigate an alternative method. Building directly on the EQA of the first project and using the scenario of a lab that services renal patients, students undertake a method validation comparing BCP and BCG assays in another eight-week project. Precision and patient comparison studies allow students to assess whether the BCP method addresses the proportional bias of the BCG method and overall is a ‘better’ alternative method for analysing serum albumin, accounting for pragmatic factors, such as cost, as well as performance characteristics. Results Students develop understanding of the purpose and importance of QC and EQA in delivering quality results, the need to optimise testing to deliver quality results and importantly, a working knowledge of the analyses that go into ensuring this quality. In parallel to developing these key workplace competencies, students become confident, competent practitioners, able to pipette accurately and precisely and organise themselves in a busy, time pressured work environment.
Resumo:
This paper discusses the use of observational video recordings to document young children’s use of technology in their homes. Although observational research practices have been used for decades, often with video-based techniques, the participant group in this study (i.e., very young children) and the setting (i.e., private homes), provide a rich space for exploring the benefits and limitations of qualitative observation. The data gathered in this study point to a number of key decisions and issues that researchers must face in designing observational research, particularly where non-researchers (in this case, parents) act as surrogates for the researcher at the data collection stage. The involvement of parents and children as research videographers in the home resulted in very rich and detailed data about children’s use of technology in their daily lives. However, limitations noted in the dataset (e.g., image quality) provide important guidance for researchers developing projects using similar methods in future. The paper provides recommendations for future observational designs in similar settings and/or with similar participant groups.
Resumo:
We have used the density matrix renormalization group (DMRG) method to study the linear and nonlinear optical responses of first generation nitrogen based dendrimers with donor acceptor groups. We have employed Pariser–Parr–Pople Hamiltonian to model the interacting pi electrons in these systems. Within the DMRG method we have used an innovative scheme to target excited states with large transition dipole to the ground state. This method reproduces exact optical gaps and polarization in systems where exact diagonalization of the Hamiltonian is possible. We have used a correction vector method which tacitly takes into account the contribution of all excited states, to obtain the ground state polarizibility, first hyperpolarizibility, and two photon absorption cross sections. We find that the lowest optical excitations as well as the lowest excited triplet states are localized. It is interesting to note that the first hyperpolarizibility saturates more rapidly with system size compared to linear polarizibility unlike that of linear polyenes.
Resumo:
The aim of this study was to examine the antimicrobial susceptibility of 97 Haemophilus parasuis cultured from Australian pigs. As there is no existing standard antimicrobial susceptibility technique available for H. parasuis, methods utilising the supplemented media, BA/SN for disc diffusion and test medium broth (TMB) for a microdilution technique, were initially evaluated with the reference strains recommended by the Clinical and Laboratory Standards Institute. The results of the media evaluation suggested that BA/SN and TMB can be used as suitable media for susceptibility testing of H. parasuis. The proposed microdilution technique was then used with 97 H. parasuis isolates and nine antimicrobial agents. The study found that Australian isolates showed elevated minimum inhibitory concentrations (MICs) for ampicillin (1%), penicillin (2%), erythromycin (7%), tulathromycin (9%), tilmicosin (22%), tetracycline (31%) and trimethoprim-sulfamethoxazole (40%). This study has described potential antimicrobial susceptibility methods for H. parasuis and has detected a low percentage of Australian H. parasuis isolates with elevated antimicrobial MICs.
Resumo:
The “partition method” or “sub-domain method” consists of expressing the solution of a governing differential equation, partial or ordinary, in terms of functions which satisfy the boundary conditions and setting to zero the error in the differential equation integrated over each of the sub-domains into which the given domain is partitioned. In this paper, the use of this method in eigenvalue problems with particular reference to vibration of plates is investigated. The deflection of the plate is expressed in terms of polynomials satisfying the boundary conditions completely. Setting the integrated error in each of the subdomains to zero results in a set of simultaneous, linear, homogeneous, algebraic equations in the undetermined coefficients of the deflection series. The algebraic eigenvalue problem is then solved for eigenvalues and eigenvectors. Convergence is examined in a few typical cases and is found to be satisfactory. The results obtained are compared with existing results based on other methods and are found to be in very good agreement.
Resumo:
Thin films of various metal fluorides are suited for optical coatings from infrared (IR) to ultraviolet (UV) range due to their excellent light transmission. In this work, novel metal fluoride processes have been developed for atomic layer deposition (ALD), which is a gas phase thin film deposition method based on alternate saturative surface reactions. Surface controlled self-limiting film growth results in conformal and uniform films. Other strengths of ALD are precise film thickness control, repeatability and dense and pinhole free films. All these make the ALD technique an ideal choice also for depositing metal fluoride thin films. Metal fluoride ALD processes have been largely missing, which is mostly due to a lack of a good fluorine precursor. In this thesis, TiF4 precursor was used for the first time as the fluorine source in ALD for depositing CaF2, MgF2, LaF3 and YF3 thin films. TaF5 was studied as an alternative novel fluorine precursor only for MgF2 thin films. Metal-thd (thd = 2,2,6,6-tetramethyl-3,5-heptanedionato) compounds were applied as the metal precursors. The films were grown at 175 450 °C and they were characterized by various methods. The metal fluoride films grown at higher temperatures had generally lower impurity contents with higher UV light transmittances, but increased roughness caused more scattering losses. The highest transmittances and low refractive indices below 1.4 (at 580 nm) were obtained with MgF2 samples. MgF2 grown from TaF5 precursor showed even better UV light transmittance than MgF2 grown from TiF4. Thus, TaF5 can be considered as a high quality fluorine precursor for depositing metal fluoride thin films. Finally, MgF2 films were applied in fabrication of high reflecting mirrors together with Ta2O5 films for visible region and with LaF3 films for UV region. Another part of the thesis consists of applying already existing ALD processes for novel optical devices. In addition to the high reflecting mirrors, a thin ALD Al2O3 film on top of a silver coating was proven to protect the silver mirror coating from tarnishing. Iridium grid filter prototype for rejecting IR light and Ir-coated micro channel plates for focusing x-rays were successfully fabricated. Finally, Ir-coated Fresnel zone plates were shown to provide the best spatial resolution up to date in scanning x-ray microscopy.
Resumo:
A simple yet fairly accurate method of calculating the ideal detonation velocity of an organic explosive from a knowledge of the chemical composition alone is proposed. The method is based on the concept that the energetics of a stoichiometrically balanced fuel-oxidizer system is a function of the total oxidizing or reducing valences of the composition. A combination of the valences in the form of Image , where R and P are, respectively, the reducing and oxidizing valences and MW is the molecular weight, has been found to be linearly related to the detonation velocity of the expolosive. The predicting capacity of the method has been found to be superior to other methods in the literature.
Resumo:
A new set of equations describing completely the optical phenomena in a model involving continuous rotation of secondary axes and secondary principal-stress differences are obtained. These are solved by Peano-Baker method using experimentally determined characteristic parameters for several wavelengths of light. Experimental verifications are obtained for a rectangular bar subjected to combined torsion and tension.
Resumo:
New Zealand's Greenhouse Gas Inventory (the NZ Inventory) currently estimates methane (CH4) emissions from anaerobic dairy effluent ponds by: (1) determining the total pond volume across New Zealand; (2) dividing this volume by depth to obtain the total pond surface area; and (3) multiplying this area by an observational average CH4 flux. Unfortunately, a mathematically erroneous determination of pond volume has led to an imbalanced equation and a geometry error was made when scaling-up the observational CH4 flux. Furthermore, even if these errors are corrected, the nationwide estimate still hinges on field data from a study that used a debatable method to measure pond CH4 emissions at a single site, as well as a potentially inaccurate estimation of the amount of organic waste anaerobically treated. The development of a new methodology is therefore critically needed.
Resumo:
Near infrared (NIR) spectroscopy was investigated as a potential rapid method of estimating fish age from whole otoliths of Saddletail snapper (Lutjanus malabaricus). Whole otoliths from 209 Saddletail snapper were extracted and the NIR spectral characteristics were acquired over a spectral range of 800–2780 nm. Partial least-squares models (PLS) were developed from the diffuse reflectance spectra and reference-validated age estimates (based on traditional sectioned otolith increments) to predict age for independent otolith samples. Predictive models developed for a specific season and geographical location performed poorly against a different season and geographical location. However, overall PLS regression statistics for predicting a combined population incorporating both geographic location and season variables were: coefficient of determination (R2) = 0.94, root mean square error of prediction (RMSEP) = 1.54 for age estimation, indicating that Saddletail age could be predicted within 1.5 increment counts. This level of accuracy suggests the method warrants further development for Saddletail snapper and may have potential for other fish species. A rapid method of fish age estimation could have the potential to reduce greatly both costs of time and materials in the assessment and management of commercial fisheries.
Resumo:
The objective of this study is to address the question: are those who leave suicide notes representative of the larger population of those who commit suicide? The method involves an analysis of a full population of suicides by residents of Queensland, Australia for the full year of 2004, with the information drawn from Coronial files. Our overall results suggest that, and in support of previous research, the population who leaves suicide notes are remarkably similar to those who do not. Differences are identified in four areas: first, and in contrast to prior research, females are less likely to leave a suicide note; second, and in support of previous research, Aboriginal Australians are less likely to leave suicide notes; third, and in support of some previous research, those who use gas as a method of suicide are more likely to leave notes, while those who use a vehicle or a train are less likely to leave notes; finally, our findings lend support to research which finds that those with a diagnosed mental illness are less likely to leave notes. The discussion addresses some of the reasons these disparities may have occurred, and continues the debate over the degree to which suicide notes give insight into the larger suicide population