983 resultados para FLUORESCENCE UP-CONVERSION
Resumo:
The commercial development of ocean thermal energy conversion (OTEC) operations will involve some environmental perturbations for which there is no precedent experience. The pumping of very large volumes of warm surface water and cold deep water and its subsequent discharge will result in the impingement, entrainment, and redistribution of biota. Additional stresses to biota will be caused by biocide usage and temperature depressions. However, the artificial upwelling of nutrients associated with the pumping of cold deep water, and the artificial reef created by an OTEC plant may have positive effects on the local environment. Although more detailed information is needed to assess the net effect of an OTEC operation on fisheries, certain assumptions and calculations are made supporting the conclusion that the potential risk to fisheries is not significant enough to deter the early development of IDEe. It will be necessary to monitor a commercial-scale plant in order to remove many of the remaining uncertainties. (PDF file contains 39 pages.)
Resumo:
The 2009/28/EC Directive requires Member States of the European Union to adopt a National Action Plan for Renewable Energy. In this context, the Basque Energy Board, EVE, is committed to research activities such as the Mutriku Oscillating Water Column plant, OWC. This is an experimental facility whose concept consists of a turbine located in a pneumatic energy collection chamber and a doubly fed induction generator that converts energy extracted by the turbine into a form that can be returned to the network. The turbo-generator control requires a precise knowledge of system parameters and of the rotor angular velocity in particular. Thus, to remove the rotor speed sensor implies a simplification of the hardware that is always convenient in rough working conditions. In this particular case, a Luenberger based observer is considered and the effectiveness of the proposed control is shown by numerical simulations. Comparing these results with those obtained using a traditional speed sensor, it is shown that the proposed solution provides better performance since it increases power extraction in the sense that it allows a more reliable and robust performance of the plant, which is even more relevant in a hostile environment as the ocean.
Resumo:
The optimization of solution-processed organic bulk-heterojunction solar cells with the acceptor-substituted quinquethiophene DCV5T-Bu-4 as donor in conjunction with PC61BM as acceptor is described. Power conversion efficiencies up to 3.0% and external quantum efficiencies up to 40% were obtained through the use of 1-chloronaphthalene as solvent additive in the fabrication of the photovoltaic devices. Furthermore, atomic force microscopy investigations of the photoactive layer gave insight into the distribution of donor and acceptor within the blend. The unique combination of solubility and thermal stability of DCV5T-Bu-4 also allows for fabrication of organic solar cells by vacuum deposition. Thus, we were able to perform a rare comparison of the device characteristics of the solution-processed DCV5T-Bu-4:PC61BM solar cell with its vacuum-processed DCV5T-Bu-4:C-60 counterpart. Interestingly in this case, the efficiencies of the small-molecule organic solar cells prepared by using solution techniques are approaching those fabricated by using vacuum technology. This result is significant as vacuum-processed devices typically display much better performances in photovoltaic cells. Keywords
Resumo:
The smart grid is a highly complex system that is being formed from the traditional power grid, adding new and sophisticated communication and control devices. This will enable integrating new elements for distributed power generation and also achieving an increasingly automated operation so for actions of the utilities as for customers. In order to model such systems a bottom-up method is followed, using only a few basic elements which are structured into two layers: a physical layer for the electrical power transmission, and one logical layer for element communication. A simple case study is presented to analyse the possibilities of simulation. It shows a microgrid model with dynamic load management and an integrated approach that can process both electrical and communication flows.
Resumo:
179 p.
Resumo:
A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was < 5 nM, and that of the MCCD was 0.1 mu M. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.
Resumo:
A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was <5 nM, and that of the MCCD was 0.1 μM. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.
Resumo:
This survey was carried out to provide the Kainji Lake Fisheries Promotion Project (KLFPP), whose overall goal is the improvement of the standard of living of fishing communities around Kainji Lake, Nigeria, managing the fisheries on a sustainable basis, with follow-up data for long-term monitoring and evaluation of the overall project goal. A similar survey, conducted in 1996, provided the baseline against which data from the current survey was evaluated. In a cross-sectional survey, anthropometric data was collected from 576 children aged 3-60 months in 282 fisherfolk households around the southern sector of Kainji Lake, Nigeria. In addition, data was collected on the nutritional status and fertility of the mothers, vaccination coverage of children and child survival indicators. For control purposes, 374 children and 181 mothers from non-fishing households around Kainji Lake were likewise covered by the survey. A standardised questionnaire was used to collect relevant data, while anthropometric measurements were made using appropriate equipment. Data compilation and analysis was carried out with a specially designed Microsoft Access application, using NCHS reference data for the analysis of anthropometric measurements. Statistical significance testing was done using EPI-INFO" software. The results of the follow-up survey indicate a slight increase in the percentage of stunted pre-school children in fishing households around Kainji Lake, from 40% in 1996 to 41% in 1999. This increase is however not statistically significant (p= 0.704). Over the same period, the percentage of stunted children in non-fishing households increased from 37% to 39% (p= 0.540), which is also not statistically significant. Likewise, there were no statistically significant differences between the 1996 and 1999 results for the prevalence of either wasted or underweight children in fishing households. The same applies to children from non-fishing households. In addition, vaccination coverage remains very low while infant and child mortality rates continue to be extremely high with about 1 in 5 children dying before their fifth birthday. There has been no perceptible and lasting improvement in the standard of living of fishing households over the course of the second project phase as indicated by the persistently high prevalence of stunting. The situation is the same for the control group, indicating that for the region as a whole, a number of factors beyond the immediate influence of the project continue to negatively impact on the standard of living. The results also show that the project activities have not had any negative long-term effect on the nutritional status of the beneficiaries. (PDF contains 44 pages)
Resumo:
Blood meal and full fat soyabean meal were mixed in different proportions to give 0%, 10%, 25%, 50%, 75%, 90% and 100% meal in the protein fraction of the diet and fed to Claria anguillaris fingerlings in floating hapas. The growth performance of the fingerlings were monitored for 84 days. At the end of the experiment the mean weight of the fingerlings increased in the level of blood meal up to 50% blood meal in the diet after which there was a decline in the mean weight of the fish. This same level of blood meal gave the best specific growth rate, feed conversion efficiency and protein efficiency ratio. Thus the nutritive value of blood meal was enhanced by the addition of an equal level of full fat soyabean meal in the diet
Resumo:
An experimental study on the angular distribution and conversion of multi-keV X-ray sources produced from 2 ns-duration 527nm laser irradiated thick-foil targets on Shenguang II laser facility (SG-II) is reported. The angular distributions measured in front of the targets can be fitted with the function of f(theta) = alpha+ (1- alpha)cos(beta) theta (theta is the viewing angle relative to the target normal), where alpha = 0.41 +/- 0.014, beta = 0.77 +/- 0.04 for Ti K-shell X-ray Sources (similar to 4.75 keV for Ti K-shell), and alpha = 0.085 +/- 0.06, beta = 0.59 +/- 0.07 for Ag/Pd/Mo L-shell X-ray Sources (2-2.8 keV for Mo L-shell, 2.8-3.5 keV for Pd L-shell, and 3-3.8 keV for Ag L-shell). The isotropy of the angular-distribution of L-shell emission is worse than that of the K-shell emission at larger viewing angle (>70 degrees), due to its larger optical depth (stronger self-absorption) in the cold plasma side lobe Surrounding the central emission region, and in the central hot plasma region (emission region). There is no observable difference in the angular distributions of the L-shell X-ray emission among Ag, Pd, and Mo. The conversion efficiency of Ag/Pd/Mo L-shell X-ray sources is higher than that of the Ti K-shell X-ray sources, but the gain relative to the K-shell emission is not as high as that by using short pulse lasers. The conversion efficiency of the L-shell X-ray sources decrease, with increasing atomic numbers (or X-ray photon energy), similar to the behavior of the K-shell X-ray Source.