903 resultados para FEMORAL-SHAFT FRACTURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was performed to characterize evidence of potential unconformity-type U mineralizing fluids in drill core fractures from the Stewardson Lake prospect, in the Athabasca Basin, located in Northern Saskatchewan and Alberta, Canada. Fractures were visually classified into eight varieties. This classification scheme was improved with the use of mineralogical characterization through SEM (Scanning Electron Microscope) and XRD analyses of the fracture fills and resulted in the identification of various oxides, hydroxides, sulfides, and clays or clay-sized minerals. Fractures were tallied to a total of ten categories with some commonalities in color. The oxidative, reductive or mixed nature of the fluids interacting with each fracture was determined based on its fill mineralogy. The measured Pb isotopic signature of samples was used to distinguish fractures affected solely by fluids emanating from a U mineralization source, from those affected by mixed fluids. Anomalies in U and U-pathfinder elements detected in fractures assisted with attributing them to the secondary dispersion halo of potential mineralization. Three types of fracture functions (chimney, composite and drain) were defined based on their interpreted flow vector and history. A secondary dispersion halo boundary with a zone of dominance of infiltrating fluids was suggested for two boreholes. The control of fill mineralogy on fracture color was investigated and the indicative and non-indicative colors and minerals, with respect to a secondary dispersion halo, were formally described. The fracture colors and fills indicative of proximity to the basement host of the potential mineralization were also identified. In addition, three zones of interest were delineated in the boreholes with respect to their geochemical dynamics and their relationship to the potential mineralization: a shallow barren overburden zone, a dispersion and alteration zone at intermediate depth, and a second deeper zone of dispersion and alteration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the distal femur after resection for malignant bone tumors in skeletally immature children is challenging. The use of megaprostheses has become increasingly popular in this patient group since the introduction of custom-made, expandable devices that do not require surgery for lengthening, such as the Repiphysis(®) Limb Salvage System. Early reports on the device were positive but more recently, a high complication rate and associated bone loss have been reported. QUESTIONS/PURPOSES: We asked: (1) what are the clinical outcomes using the Musculoskeletal Tumor Society (MSTS) scoring system after 5-year minimum followup in patients treated with this prosthesis at one center; (2) what are the problems and complications associated with the lengthening procedures of this implant; and (3) what are the specific concerns associated with revision of this implant? METHODS: At our institute, between 2002 and 2007, the Repiphysis(®) expandable prosthesis was implanted in 15 children (mean age, 8 years; range, 6-11 years) after distal femoral resection for malignant bone tumors. During this time, the general indication for use of this implant was resection of the distal femur for localized malignant bone tumors in pediatric patients. Alternative techniques used for this indication were modular prosthetic reconstruction, massive (osteoarticular or intercalary) allograft reconstruction, or rotationplasty. Age and tumor extension were the main factors to decide on the surgical indication. Of the 15 patients who had this prosthesis implanted during reconstruction surgery, five died with the implant in situ or underwent amputation before 5 years followup and the remaining 10 were evaluated at a minimum of 5 years (mean, 104 months; range, 78-140 months). No patients were lost to followup. These 10 patients were long-term survivors and underwent the lengthening program. They were included in our study analysis. The first seven lengthening procedures were attempted in an outpatient setting; however, owing to pain and burning sensations experienced by the patients, the procedures failed to achieve the desired lengthening. Therefore, other procedures were performed with the patients under general anesthesia. We reviewed clinical data at index surgery for all 15 patients. We further analyzed the lengthening procedures, implant survival, radiographic and functional results, for the 10 long-term survivors. Functional results were assessed according to the MSTS scoring system. Complications were classified according to the International Society of Limb Salvage (ISOLS) classification system. RESULTS: Nine of the 10 survivors underwent revision of the implant for mechanical failure. They had a mean MSTS score of 64% (range, 47%-87%) before revision surgery. At final followup the 10 long-term surviving patients had an average MSTS score of 81% (range, 53%-97%). In total, we obtained an average lengthening of 39 mm per patient (range, 17-67 mm). Exact expansion of the implant was unpredictable and difficult to control. Nine of 10 of the long-term surviving patients underwent revision surgery of the prosthesis-eight for implant breakage and one for stem loosening. At revision surgery, six patients had another type of expandable prosthesis implanted and three had an adult-type megaprosthesis implanted. In five cases, segmental bone grafts were used during revision surgery to compensate for loss of bone stock. CONCLUSIONS: We could not comfortably expand the Repiphysis(®) prosthesis in an outpatient setting because of pain experienced by the patients during the lengthening procedures. Furthermore, use of the prosthesis was associated with frequent failures related to implant breakage and stem loosening. Revisions of these procedures were complex and difficult. We no longer use this prosthesis and caution others against the use of this particular prosthesis design. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim. It has been reported that femoral hernias are rather common after a previous repair of inguinal hernia. We herein present a modified patch repair technique for large femoral hernias that develop after a Lichtenstein operation for ipsilateral inguinal hernia. Patients and methods. The modified technique for femoral hernia was applied to three patients who had a Lichtenstein repair for inguinal hernia. All patients were male. Hernia sac is dissected completely and sent back into to the preperitoneal space. Special attention should be given to the prevascular component of the sac. It is dissected as deep as possible into the preperitoneal space over the femoral vein. The defect is quite wide in this particular type of femoral hernia following Lichtenstein repair. A prosthetic patch that matches the defect is prepared. The medial edge of the mesh is configured to correspond to the pubic corner and lacunar ligament. The lateral margin of the patch is cut to create several petals for inverting the mesh above and medial to the femoral vein to prevent prevascular herniation. The mesh is secured to inguinal ligament, ilioinguinal tract, lacunar ligament, and Cooper ligament. Few sutures are put on the pubic corner and lacunar ligament. Results. One patient was discharged after two hours, other two stayed overnight. Readmission because of seroma development was recorded in two cases where standard polypropylene meshes were used. No complication was observed in the other patient who received lightweight meshes. No early recurrences were recorded after 4, 9, and 30 months. Conclusion. Femoral recurrence after previous inguinal hernia repair seems to be a specific entity. It has a prevascular component and the hernia defect can be much larger than that of a primary femoral hernia. A patch repair with infra-inguinal approach can be a valuable alternative with low complication rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the distal femur after resection for malignant bone tumors in skeletally immature children is challenging. The use of megaprostheses has become increasingly popular in this patient group since the introduction of custom-made, expandable devices that do not require surgery for lengthening, such as the Repiphysis(®) Limb Salvage System. Early reports on the device were positive but more recently, a high complication rate and associated bone loss have been reported. QUESTIONS/PURPOSES: We asked: (1) what are the clinical outcomes using the Musculoskeletal Tumor Society (MSTS) scoring system after 5-year minimum followup in patients treated with this prosthesis at one center; (2) what are the problems and complications associated with the lengthening procedures of this implant; and (3) what are the specific concerns associated with revision of this implant? METHODS: At our institute, between 2002 and 2007, the Repiphysis(®) expandable prosthesis was implanted in 15 children (mean age, 8 years; range, 6-11 years) after distal femoral resection for malignant bone tumors. During this time, the general indication for use of this implant was resection of the distal femur for localized malignant bone tumors in pediatric patients. Alternative techniques used for this indication were modular prosthetic reconstruction, massive (osteoarticular or intercalary) allograft reconstruction, or rotationplasty. Age and tumor extension were the main factors to decide on the surgical indication. Of the 15 patients who had this prosthesis implanted during reconstruction surgery, five died with the implant in situ or underwent amputation before 5 years followup and the remaining 10 were evaluated at a minimum of 5 years (mean, 104 months; range, 78-140 months). No patients were lost to followup. These 10 patients were long-term survivors and underwent the lengthening program. They were included in our study analysis. The first seven lengthening procedures were attempted in an outpatient setting; however, owing to pain and burning sensations experienced by the patients, the procedures failed to achieve the desired lengthening. Therefore, other procedures were performed with the patients under general anesthesia. We reviewed clinical data at index surgery for all 15 patients. We further analyzed the lengthening procedures, implant survival, radiographic and functional results, for the 10 long-term survivors. Functional results were assessed according to the MSTS scoring system. Complications were classified according to the International Society of Limb Salvage (ISOLS) classification system. RESULTS: Nine of the 10 survivors underwent revision of the implant for mechanical failure. They had a mean MSTS score of 64% (range, 47%-87%) before revision surgery. At final followup the 10 long-term surviving patients had an average MSTS score of 81% (range, 53%-97%). In total, we obtained an average lengthening of 39 mm per patient (range, 17-67 mm). Exact expansion of the implant was unpredictable and difficult to control. Nine of 10 of the long-term surviving patients underwent revision surgery of the prosthesis-eight for implant breakage and one for stem loosening. At revision surgery, six patients had another type of expandable prosthesis implanted and three had an adult-type megaprosthesis implanted. In five cases, segmental bone grafts were used during revision surgery to compensate for loss of bone stock. CONCLUSIONS: We could not comfortably expand the Repiphysis(®) prosthesis in an outpatient setting because of pain experienced by the patients during the lengthening procedures. Furthermore, use of the prosthesis was associated with frequent failures related to implant breakage and stem loosening. Revisions of these procedures were complex and difficult. We no longer use this prosthesis and caution others against the use of this particular prosthesis design. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

International audience

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 18-year-old male patient with a diagnosis of pseudoaneurysm of the right supericial femoral artery secondary to penetrating injury by gunshot, which was treated in our Hospital with an aneurysm resection and a saphenous vascular graft inverted with a satisfactory evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical impedance tomography is applied to the problem of detecting, locating, and tracking fractures in ballistics gelatin. The hardware developed is intended to be physically robust and based on off-the-shelf hardware. Fractures were created in two separate ways: by shooting a .22 caliber bullet into the gelatin and by injecting saline solution into the gelatin. The .22 caliber bullet created an air gap, which was seen as an increase in resistivity. The saline solution created a fluid filled gap, which was seen as a decrease in resistivity. A double linear array was used to take data for each of the fracture mechanisms and a two dimensional cross section was inverted from the data. The results were validated by visually inspecting the samples during the fracture event. It was found that although there were reconstruction errors present, it was possible to reconstruct a representation of the resistive cross section. Simulations were performed to better understand the reconstructed cross-sections and to demonstrate the ability of a ring array, which was not experimentally tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-Destructive Testing (NDT) of deep foundations has become an integral part of the industry’s standard manufacturing processes. It is not unusual for the evaluation of the integrity of the concrete to include the measurement of ultrasonic wave speeds. Numerous methods have been proposed that use the propagation speed of ultrasonic waves to check the integrity of concrete for drilled shaft foundations. All such methods evaluate the integrity of the concrete inside the cage and between the access tubes. The integrity of the concrete outside the cage remains to be considered to determine the location of the border between the concrete and the soil in order to obtain the diameter of the drilled shaft. It is also economic to devise a methodology to obtain the diameter of the drilled shaft using the Cross-Hole Sonic Logging system (CSL). Performing such a methodology using the CSL and following the CSL tests is performed and used to check the integrity of the inside concrete, thus allowing the determination of the drilled shaft diameter without having to set up another NDT device. This proposed new method is based on the installation of galvanized tubes outside the shaft across from each inside tube, and performing the CSL test between the inside and outside tubes. From the performed experimental work a model is developed to evaluate the relationship between the thickness of concrete and the ultrasonic wave properties using signal processing. The experimental results show that there is a direct correlation between concrete thicknesses outside the cage and maximum amplitude of the received signal obtained from frequency domain data. This study demonstrates how this new method to measuring the diameter of drilled shafts during construction using a NDT method overcomes the limitations of currently-used methods. In the other part of study, a new method is proposed to visualize and quantify the extent and location of the defects. It is based on a color change in the frequency amplitude of the signal recorded by the receiver probe in the location of defects and it is called Frequency Tomography Analysis (FTA). Time-domain data is transferred to frequency-domain data of the signals propagated between tubes using Fast Fourier Transform (FFT). Then, distribution of the FTA will be evaluated. This method is employed after CSL has determined the high probability of an anomaly in a given area and is applied to improve location accuracy and to further characterize the feature. The technique has a very good resolution and clarifies the exact depth location of any void or defect through the length of the drilled shaft for the voids inside the cage. The last part of study also evaluates the effect of voids inside and outside the reinforcement cage and corrosion in the longitudinal bars on the strength and axial load capacity of drilled shafts. The objective is to quantify the extent of loss in axial strength and stiffness of drilled shafts due to presence of different types of symmetric voids and corrosion throughout their lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les méthodes d'opération permettant la stabilisation temporaire de fractures du fémur ont peu changé dans les dernières décennies. Ce mémoire illustre d'abord les différentes techniques chirurgicales présentement utilisées. Ces dernières sont principalement des outils manuels très simples. Un survol des recherches universitaires sur le sujet démontre que l'effort se porte principalement sur des manipulateurs robotisés complexes qui sont peu susceptibles d'être utilisés dans les salles d'opération à court terme. Avec l'aide de chirurgiens, il a été possible de connaître les besoins de ceux-ci en ce qui concerne la réduction et la stabilisation de fractures. Un appareil mécanique transparent à la radiographie a été conçu. Pour ce faire, plusieurs éléments de machine et mécanismes ont dû être développés en matériaux plastiques ou composites. L'appareil permet aux chirurgiens de déplacer un des fragments de l'os dans les six degrés de liberté puis de le maintenir stable. Un prototype a été fabriqué. Des essais avec un simulateur de fracture ont permis de récolter les commentaires de chirurgiens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo del estudio es evaluar la mortalidad a un año en pacientes con fractura de cadera, mayores de 65 años tratados en un programa establecido de orto-geriatría. 298 se trataron de acuerdo al protocolo de orto-geriatría, se calculo la mortalidad a un año, se establecieron los predictores de mortalidad orto-geriátrico. La sobrevida anual se incremento de 80% a 89% (p = .039) durante los cuatro años de seguimiento del programa y disminuyo el riesgo de mortalidad anual postoperatorio (Hazard Ratio = 0.54, p = .049). La enfermedad cardiaca y la edad maor a 85 años fueron predictores positivos para mortalidad.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the lubrication theory is used to model flow in geological fractures and analyse the compound effect of medium heterogeneity and complex fluid rheology. Such studies are warranted as the Newtonian rheology is adopted in most numerical models because of its ease of use, despite non-Newtonian fluids being ubiquitous in subsurface applications. Past studies on Newtonian and non-Newtonian flow in single rock fractures are summarized in Chapter 1. Chapter 2 presents analytical and semi-analytical conceptual models for flow of a shear-thinning fluid in rock fractures having a simplified geometry, providing a first insight on their permeability. in Chapter 3, a lubrication-based 2-D numerical model is first implemented to solve flow of an Ellis fluid in rough fractures; the finite-volumes model developed is more computationally effective than conducting full 3-D simulations, and introduces an acceptable approximation as long as the flow is laminar and the fracture walls relatively smooth. The compound effect of shear-thinning fluid nature and fracture heterogeneity promotes flow localization, which in turn affects the performance of industrial activities and remediation techniques. In Chapter 4, a Monte Carlo framework is adopted to produce multiple realizations of synthetic fractures, and analyze their ensemble statistics pertaining flow for a variety of real non-Newtonian fluids; the Newtonian case is used as a benchmark. In Chapter 5 and Chapter 6, a conceptual model of the hydro-mechanical aspects of backflow occurring in the last phase of hydraulic fracturing is proposed and experimentally validated, quantifying the effects of the relaxation induced by the flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lower limb amputation is an event that inevitably changes the lifestyle of the person with a significant impact on quality of life. The socket-type prosthesis entails that the residual limb is in direct contact with the socket which often implies numerous disadvantages. Osseointegrated prosthesis is a solution that avoids skin problems because not include the presence of the socket. In this type of prosthesis, a stem is surgically inserted inside the medullary canal and connected with the external prosthetic limb. Therefore, this thesis aims to highlight and explore the main strengths and problems of osseointegrated prostheses and to examine the role of physical activity, with attention to functional capacity and bone quality. The objectives of the thesis will be developed through 5 studies: (I) A gait analysis of a 44 years-old male patient who underwent surgery for the implantation of an osseointegrated prosthesis; (II) A systematic review to investigate the state of stump bone quality in patients with limb amputations; (III) A systematic review of the technologies involved in such devices has been carried out to identify the most fruitful ones in improving bone quality; (IV) A systematic review investigating the topic of physical activity and bone turnover biomarkers; (V) A systematic review to investigate the effects of physical activity interventions combined with drug treatments on bone biomarkers in people with osteopenia and osteoporosis. The integrated prosthesis is a good solution for people with lower limb amputation who cannot use their traditional socket-type prosthesis. Although many objectives have already been achieved, there are still many aspects that we can improve. These include the creation of a multidisciplinary path that support patients along their path, with particular attention to the pre-surgery and the post-rehabilitation phase that is still lacking even if of fundamental impact in determining the quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To determine the mechanisms predisposing penile fracture as well as the rate of long-term penile deformity and erectile and voiding functions. Methods. All fractures were repaired on an emergency basis via subcoronal incision and absorbable suture with simultaneous repair of eventual urethral lesion. Patients' status before fracture and voiding and erectile functions at long term were assessed by periodic follow-up and phone call. Detailed history included cause, symptoms, and single-question self-report of erectile and voiding functions. Results. Among the 44 suspicious cases, 42 (95.4%) were confirmed, mean age was 34.5 years (range: 18-60), mean follow-up 59.3 months (range 9-155). Half presented the classical triad of audible crack, detumescence, and pain. Heterosexual intercourse was the most common cause (28 patients, 66.7%), followed by penile manipulation (6 patients, 14.3%), and homosexual intercourse (4 patients, 9.5%). Woman on top was the most common heterosexual position (n = 14, 50%), followed by doggy style (n = 8, 28.6%). Four patients (9.5%) maintained the cause unclear. Six (14.3%) patients had urethral injury and two (4.8%) had erectile dysfunction, treated by penile prosthesis and PDE-5i. No patient showed urethral fistula, voiding deterioration, penile nodule/curve or pain. Conclusions. Woman on top was the potentially riskiest sexual position (50%). Immediate surgical treatment warrants long-term very low morbidity.