923 resultados para Eye enucleation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the knowledge glaucoma patients have about their disease and its treatment. METHODS: One hundred and eighty-three patients were interviewed at the Glaucoma Service of Wills Eye Hospital (Philadelphia, USA, Group 1) and 100 at the Glaucoma Service of University of Campinas (Campinas, Brazil, Group 2). An informal, relaxed atmosphere was created by the interviewer before asking a list of 18 open-ended questions. RESULTS: In Group 1, 44% of the 183 patients did not have an acceptable idea about what glaucoma is, 30% did not know the purpose of the medications they were taking, 47% were not aware of what was an average intraocular pressure, and 45% did not understand why visual fields were examined. In Group 2, 54% gave unsatisfactory answers to the question What is glaucoma?, 54% did not know the purpose of the medications they were taking, 80% were not aware of what was an average intraocular pressure, and 94% did not understand why visual fields were examined (p<0.001). Linear regression analysis demonstrated that level of education was positively correlated to knowledge about glaucoma in both groups (r=0.65, p=0.001). CONCLUSION: This study showed that patients' knowledge about glaucoma varies greatly, and that in an urban, American setting, around one third of the patients have minimal understanding, whereas in an urban setting in Brazil around two thirds of patients were lacking basic information about glaucoma. Innovative and effective methods are needed to correct this situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the mean critical fusion frequency and the short-term fluctuation, to analyze the influence of age, gender, and the learning effect in healthy subjects undergoing flicker perimetry. METHODS: Study 1 - 95 healthy subjects underwent flicker perimetry once in one eye. Mean critical fusion frequency values were compared between genders, and the influence of age was evaluated using linear regression analysis. Study 2 - 20 healthy subjects underwent flicker perimetry 5 times in one eye. The first 3 sessions were separated by an interval of 1 to 30 days, whereas the last 3 sessions were performed within the same day. The first 3 sessions were used to investigate the presence of a learning effect, whereas the last 3 tests were used to calculate short-term fluctuation. RESULTS: Study 1 - Linear regression analysis demonstrated that mean global, foveal, central, and critical fusion frequency per quadrant significantly decreased with age (p<0.05).There were no statistically significant differences in mean critical fusion frequency values between males and females (p>0.05), with the exception of the central area and inferonasal quadrant (p=0.049 and p=0.011, respectively), where the values were lower in females. Study 2 - Mean global (p=0.014), central (p=0.008), and peripheral (p=0.03) critical fusion frequency were significantly lower in the first session compared to the second and third sessions. The mean global short-term fluctuation was 5.06±1.13 Hz, the mean interindividual and intraindividual variabilities were 11.2±2.8% and 6.4±1.5%, respectively. CONCLUSION: This study suggests that, in healthy subjects, critical fusion frequency decreases with age, that flicker perimetry is associated with a learning effect, and that a moderately high short-term fluctuation is expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To collect information and opinions from a group of diabetic patients regarding diabetic retinopathy and its treatment, in order to get reliable information that can help to improve programs and actions to control and prevent this ocular disease. METHODS: A cross-sectional study was performed. The sample was from 980 diabetic patients seen in a diabetic association. A previous questionnaire was made with general questions about the main subject. Thereafter, an appropriate questionnaire was prepared. RESULTS: The sample showed that among 299 patients with age ranging from 16 to 83 years, with a mean of 57 years, mainly female (67.91%) did not know how severe their disease was (30.8%), or believed that it was not a serious problem (19.7%). The laser technique to solve diabetic retinopathy was known by 60.2% of the patients. It was reported as the only treatment available by 24.1%. Among the reasons for no treatment 59.8% reported that they did not think it was necessary and 29.7% could not afford it. CONCLUSIONS: Patients showed lack of knowledge about how serious is diabetic retinopathy, the possibility of using laser technique for it and the severity of the disease. Some patients believed in the efficacy of the treatment and some patients did not, but all of them reported that they were afraid of submitting to it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report a case of Nocardia asteroides scleritis in a patient without risk factors for infeccious scleritis. METHODS: A 38-year old woman was initially examined for pain, discharge, photophobia of 1 month duration in her right eye. Her medical and ophthalmological history were unremarkable. The results of laboratory tests were normal. Surgical debridement of necrotic tissue was performed and material was sent for biopsy and culture confirmed as Nocardia asteroides. Treatment consisted of amikacin eyedrops, and systemic trimethropim-sulfamethoxazole. The infection resolved leaving scleral thinning and a subconjunctival fibrovascular scar. Best corrected visual acuity two months after referral had improved to LE, 20/20. CONCLUSION: Prompt evaluation and treatment is essential for successful management of Nocardia asteroides infectious scleritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case of identical male twins with Cohen syndrome who present multiple ophthalmic findings is reported. The patients were identical 16 year-old twin boys who showed down slanting eyelids, mild ptosis, high-grade myopia, small cortical lens opacities, posterior subcapsular cataracts, myotic and corectopic pupils with poor dilation due to focal iris atrophy and retinochoroidal dystrophy. Ophthalmologists must be aware of the ocular and systemic findings of Cohen syndrome in the evaluation of young patients with mental retardation and visual impairment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: In Divinolândia (SP), the Consortium of Development of São João da Boa Vista Region Policy (CONDERG), in partnership with State University of Campinas (UNICAMP), has founded an eyeglass store to produce low cost glasses to distribute freely to their customers. The purpose is to analyze the evolution and working process of CONDERG eyeglass store in the last 13 years, since its foundation. METHODS: Data were collected from CONDERG store files from 1988 to 2001. Data regarding the amount of spectacles produced per year, ability to increase the production and store feasibility were analyzed. RESULTS: In 13 years, 16,500 spectacles were supplied. Currently, 400 spectacles are delivered per month, being 200 supported by SUS and the other 200 by CONDERG's own resources. CONCLUSION: The 13-year operation of CONDERG eyeglass store, the free provision of 16,500 spectacles and the increase productive ability have shown this model feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hyaluronic acid is a polysaccharide of the glycosaminoglycan family present in mammal tissues. In the eye, it can be found in the cornea, the sclera and the vitreous humor. Currently, it has been employed in several medical specialties, including ophthalmology. The objective of this paper is to demonstrate the various current and future ophthalmic applications of this substance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 33-year-old woman complained of unilateral eyelid edema and blurred vision. Initial ophthalmic examination disclosed anterior chamber reaction with keratic precipitates on the cornea, without posterior abnormalities. Anterior uveitis was treated. Despite that, patient showed rapidly progressive unilateral vision loss with optic nerve swelling. Systemic workup was inconclusive, as well as cranial magnetic resonance imaging and cerebrospinal fluid examination. Based on the hypothesis of optic neuritis, intravenous methylprednisolone pulse was performed with no success. During the following days, the patient presented pericardial effusion and cardiac tamponade, progressing to death. Necropsy was performed and diagnosis of extranodal natural killers/T-cell lymphoma, nasal type with ocular involvement was confirmed by immunohistochemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ocular surface toxicity of two nitric oxide donors in ex vivo and in vivo animal models: S-nitrosoglutathione (GSNO) and S-nitroso-N-acetylcysteine (SNAC) in a hydroxypropyl methylcellulose (HPMC) matrix at final concentrations 1.0 and 10.0 mM. METHODS: Ex vivo GSNO and SNAC toxicities were clinically and histologically analyzed using freshly excised pig eyeballs. In vivo experiments were performed with 20 albino rabbits which were randomized into 4 groups (5 animals each): Groups 1 and 2 received instillations of 150 µL of aqueous HPMC solution containing GSNO 1.0 and 10.0 mM, respectively, in one of the eyes; Groups 3 and 4 received instillations of 150 µL of aqueous HPMC solution-containing SNAC 1.0 and 10.0 mM, respectively, in one of the eyes. The contralateral eyes in each group received aqueous HPMC as a control. All animals underwent clinical evaluation on a slit lamp and the eyes were scored according to a modified Draize eye test and were histologically analyzed. RESULTS: Pig eyeballs showed no signs of perforation, erosion, corneal opacity or other gross damage. These findings were confirmed by histological analysis. There was no difference between control and treated rabbit eyes according to the Draize eye test score in all groups (p>0.05). All formulations showed a mean score under 1 and were classified as non-irritating. There was no evidence of tissue toxicity in the histological analysis in all animals. CONCLUSION: Aqueous HPMC solutions containing GSNO and SNAC at concentrations up to 10.0 mM do not induce ocular irritation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate iris reproduction in the fabrication of ocular prosthesis in order to match the remaining eye is a key factor to mask the loss and achieve an esthetic outcome for anophthalmic patients. This study evaluated the stability of acrylic paints used for replicating iris color in ocular prostheses by the analysis of two factors: the temperature of the acrylic resin polymerization cycle during prosthesis fabrication and the incidence of sun light, which is the main photodegrading agent undermining the longevity of ocular prostheses. An accelerated aging assay was used for both analyses. Specimens simulating the prosthetic iris in the colors blue, yellow, black, brown and green were fabricated, and were submitted to a colorimetric reading before and after undergoing the thermal conditions of acrylic resin polymerization. Next, the specimens were submitted to an artificial accelerated aging assay with ultraviolet radiation A and weekly colorimetric readings during a 3-week period. The color change (??*) values for the four specimens painted with the same color paint were averaged and the resulting values were considered for statistical analysis. Levine's test and Student's t-test were used to analyze the influence of the temperature of the polymerization cycle during prosthesis fabrication on the color stability of each acrylic resin paint. Friedman's test for three dependent samples was used for analysis of color photodegradation as function of time. Significance level was set at 0.05 for all analyses. It was observed that, after the action of the temperature of the polymerization cycle, alteration above clinically acceptable level of ??*> 3.3 was observed only for the yellow color. After the accelerated aging assay, there were statistically significant differences (p<0.05) as a function of time in the green, brown, black and blue colors. Changes were clinically acceptable for the brown and black colors; slightly above the clinically acceptable limit for the green color; and significantly high and impracticable from a clinical standpoint for the blue color. There was no statistically significant differences (p>0.05) for the yellow color, which presented color change only a little above the clinically acceptable limit. In conclusion: 1. Only the yellow color presented alterations above the clinically acceptable levels after the polymerization cycle; 2. After accelerated aging, there was no changes in the yellow color above the clinically acceptable levels; 3. For the green color, degradation was significant and slightly above the clinically acceptable levels; 4. The black, brown and blue colors presented significant alterations as function of time; the alterations of the brown and black colors were within acceptable clinical levels, while the blue color presented a more accentuated degradation over time.