996 resultados para Espósito, Fabio


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Bone graft procedures have been used commonly in buco-maxillo-facial surgery. For this reason, many researchers have evaluated the bone substitutes.Purpose:The present study evaluated soft and hard tissue reactions to two different hydroxyapatites HAs (synthetic HA and natural HA) and bioactive glass implanted into the sockets immediately after extraction.Materials and Methods:First and third upper and lower premolars, on both sides, were extracted from six female dogs. The alveolar sockets were randomly assigned to four groups: Group 1 - control (unfilled), Group 2 - filled with synthetic hydroxyapatite, Group 3 - filled with bovine bone mineral (natural HA), and Group 4 - filled with bioactive glass. The animals were euthanized at 4 weeks (n = 2), 8 weeks (n = 2), and 28 weeks (n = 2) after extraction. The mandible and maxilla of each animal were removed for histological analysis to determine soft tissue reactions, newly formed bone, bone characteristics, and presence or absence of implanted materials.Results:Most particles of synthetic hydroxyapatite had bone formation on their surface, although some particles showed a layer of fibrous connective tissue. The bovine bone mineral group exhibited particles partially replaced with bone formation. The bioactive glass group showed particles with a thin layer of calcified tissue, but was absent in some specimens, suggesting complete resorption.Conclusion:All biomaterials had similar behavior. Bovine bone mineral, compared to synthetic hydroxyapatite and bioactive glass, showed a larger number of particles covered with osseous tissue. All biomaterials interfered with the socket repair process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was designed to investigate the effectiveness of different ultrasonic instruments on the root surface. Fourteen patients with 35 single root teeth designated for extraction were recruited to the present study. Teeth were assigned to four experimental groups: group 1, piezoelectric ultrasonic device; group 2, magnetostrictive ultrasonic device; group 3, hand instrumentation; and group 4, untreated teeth (control). After instrumentation, the teeth were extracted and the presence of residual deposits (roughness and root surfaces characteristics) were analyzed. The results showed that residual deposits were similar in all tested groups: piezoelectric, 8.7%; magnetostrictive, 9.7%; hand instrumentation, 11.1% and control, 76.4%. There were statistically significant differences between control and all the experimental groups (p < 0.0001). With respect to roughness parameters evaluation, R(a) and R(z) of the roots treated with the different instruments showed a similar pattern (p > 0.05), but for R(t) and R(y), a significant difference was observed (p < 0.05) among hand instrumentation and ultrasonic devices. SEM analysis revealed a similar root surface pattern for the ultrasonic devices, but curettes showed many instrumental scratches, deep gouges, and a relatively large amount of dentin was removed. Within the limits of the study, although the instruments produced similar results, root surfaces instrumentated with curettes were rougher and had more root surface tissue removed than with the ultrasonic device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low-level laser therapy (LLLT) accelerates tissue repair. Mast cells induce the proliferation of fibroblasts and the development of local fibrosis. The objective of this study was to quantify fibrosis rate and mast cells in connective tissue after endodontic sealer zinc oxide and eugenol (ZOE) was implanted and submitted to LLLT, immediately after implant and again 24 h later. Sixty mice were distributed into three groups: GI, GII, and GIII (n = 20). In GI, the tubes filled with Endofill were implanted in the animals and were not irradiated with LLLT. In GII, the tubes containing Endofill were implanted in the animals and then irradiated with red LLLT (InGaAIP) 685-nm wavelength, D=72 J/Cm(2), E = 2 J, T=58 s, P=35 mW, and in GIII, the tubes with Endofill were implanted and irradiated with infrared LLLT (AsGaAl) 830-nm wavelength, D=70 J/Cm(2), E = 2 J, T=40 s, P=50 mW. After 7 days and 30 days, the animals were killed. A series of 6-mu m-thick sections were obtained and stained with Toluidine Blue and Picrosirius and analyzed under a standard light microscope using a polarized light filter for the quantification of fibrosis. The statistics were qualitative and quantitative with a significance of 5%. The irradiation with LLLT did not offer improvement in the fibrosis rate, however, it provided a significant decrease in the concentration of independent mast cells for the period studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The release and diffusion of hydroxyl ions (OH-) of calcium hydroxide (Ca(OH)2)-based intracanal medications may be affected by the association with other substances. The aim of this study was to evaluate the diffusion of OH- ions through root dentin by the medications: G1, Ca(OH)2/saline; G2, Calen; G3, Calen/camphorated p-monochlorophenol (CMCP); and G4, Calen/0.4% chlorhexidine (CHX). Root canals from bovine teeth were prepared in a standardized manner. A cavity until dentin was prepared in the middle third of the root surface of each specimen. The external surface of the root was made impermeable using a layer of adhesive, except the prepared cavity. The root canals were filled with different medications, and teeth were individually stored in flasks containing 10 ml distilled water at 37 degrees C. The water pH was measured at 1, 3, 7, 14, 21, 30, and 60 days. Data obtained were subjected to anova and Tukeys tests. Increase in pH was observed at 3 days for Calen/CHX and from 7 to 14 days for the other mixtures. Calen paste promoted pH increase up to 21 days. Calen/CMCP had the highest pH up to 21 days, and all groups had similar results at 30 days. At 60 days, the greatest pH values were observed for Calen/CMCP and Calen alone. All different formulations of Ca(OH)2-based medications tested release hydroxyl ion that can diffuse through the dentin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the percentage of gutta-percha (PGP) in mesial root canals of mandibular molars obturated with LC (Lateral Compaction) or SC (Single Cone) ProTaper Universal System techniques at different levels of the root. Mesial root canals of 20 human permanent molars with similar anatomical characteristics were instrumented using the ProTaper Universal rotary system technique until the F2 instrument, with 20 canals filled by SC ProTaper Universal technique and 20 canals by the LC technique. The mesial roots were sectioned transversely to 3, 5, and 7 mm from the root apex. Digital images of specimens were obtained at MIC-D digital microscope in increases of 30 to 35X. The gutta-percha area was measured using ImageTool software. Data were analyzed using two-way ANOVA and Bonferroni test (a = 0.05). The SC technique provided greater PGP than the LC technique in the apical third (3 mm) (P < 0.001). In the other thirds (5 and 7 mm) there was no statistical difference between the two techniques regarding the PGP (P > 0.05). There was no statistically significant difference between thirds of the root canal for both techniques (P > 0.05). It was concluded that SC technique provided greater PGP than the LC technique in the apical third of mesial root canals of mandibular molars. There was no difference between the two techniques regarding the PGP in the cervical and middle thirds. Microsc. Res. Tech. 75:12291232, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the ability of Resilon (Resilon Research, LLC, North Branford, CT) and 2 types of gutta-percha to fill simulated lateral canals when using the Obtura II system (Model 823-700; Obtura Spartan, Fenton, MO). Methods: Forty-five human single-rooted teeth were selected and subjected to root canal preparation. After that, simulated lateral canals were made at 2, 5, and 8 mm from the working length (WL). The specimens were divided into 3 groups (n = 15) according to the filling material used: Obtura Flow 150 gutta-percha (Obtura flow), Odous Endo Flow gutta-percha (Odous; Odous de Deus Ind e Corn. Ltda Belo Horizonte, MG, Brazil), and Resilon pellets (Resilon). Root canals were filled using the Obtura II system with the tip inserted to 3 mm from the WL. No sealer was used for root canal obturation. Specimens were subjected to a tooth decalcification and clearing method, and filling of the lateral canals was analyzed by digital radiography and photographs. The measurement of lateral canal filling was done using Image Tool software (UTHSCSA Image Tool for Windows version 3.0, San Antonio, TX). Data were statistically analyzed with the Kruskal-Wallis test at 5% significance. Results: All materials showed an ability to penetrate into the simulated lateral canals, with a minimum percentage of 73% in all thirds of the root canal. Conclusions: It was concluded that gutta-percha and Resilon are solid core materials with a lateral canal filling ability when used with the Obtura II system. (J Endod 2012;38:676-679)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the apical sealing of dentinal tubules after root-end surface cutting by using Er:YAG and Nd:YAG lasers. After root-canal instrumentation and filling, apices of 50 extracted maxillary canine human teeth were resected by Er: YAG with 400 mJ, 10 Hz, for 30 sec. The samples were randomly assigned to five groups (n = 10): (GI) treated without root-end cavity, but with Nd: YAG (1.0W, 10 Hz, 20 sec) for dentinal tubules sealing; (GII) treated with root-end cavity without the use of Nd: YAG; (GIII) treated with root-end cavity and Nd: YAG application; (GIV) treated with root-end cavity made by Er: YAG with no focus and without Nd: YAG application; and (GV) treated without root-end cavity and without Nd: YAG application. The root-end cavities were performed by using Er: YAG at 300 mJ, 10 Hz, for 20 sec. Subsequently, all teeth were waterproofed and immersed in 2% methylene blue for 48 h in a vacuum environment. The samples were longitudinally sectioned, and microleakage was measured. ANOVA and the Fisher LSD test showed that GIV was less susceptible to microleakage than were the other groups (p < 0.05). Interestingly, the use of the Er: YAG with no focus showed superior dentinal tubule sealing in comparison with the other groups, even with or without root-end cavity and Nd: YAG application.