994 resultados para Elliott, Matt


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Super-luminous supernovae have a tendency to occur in faint host galaxies which are likely to have low mass and low metallicity. While these extremely luminous explosions have been observed from z=0.1 to 1.55, the closest explosions allow more detailed investigations of their host galaxies. We present a detailed analysis of the host galaxy of SN 2010gx (z=0.23), one of the best studied super-luminous type Ic supernovae. The host is a dwarf galaxy (M_g=-17.42+/-0.17) with a high specific star formation rate. It has a remarkably low metallicity of 12+log(O/H)=7.5+/-0.1 dex as determined from the detection of the [OIII] 4363 Angs line. This is the first reliable metallicity determination of a super-luminous stripped-envelope supernova host. We collected deep multi-epoch imaging with Gemini + GMOS between 240-560 days after explosion to search for any sign of radioactive nickel-56, which might provide further insights on the explosion mechanism and the progenitor's nature. We reach griz magnitudes of m_AB~26, but do not detect SN 2010gx at these epochs. The limit implies that any nickel-56 production was similar to or below that of SN 1998bw (a luminous type Ic SN that produced around 0.4 M_sun of nickel-56). The low volumetric rates of these supernovae (~10^-4 of the core-collapse population) could be qualitatively matched if the explosion mechanism requires a combination of low-metallicity (below 0.2 Z_sun), high progenitor mass (>60 M_sun) and high rotation rate (fastest 10% of rotators).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Collaborative group improvisations: Betalevel, Los Angeles; KZSU Day of Noise, Stanford; Thingamajigs performance at the Museum of California, Oakland; CCRMA Concert, Stanford; EarMeal LA Art Stream, Los Angeles; Outsound at the Luggage Store Gallery, San Francisco (with Matt Ingalls, John Ingle, Ted Byrnes, Edward Schocker & others).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coccidiostats are authorized in the European Union (EU) to be used as poultry feed additives. Maximum (residue) levels (M(R)Ls) have been set within the EU for consumer and animal protection against unintended carry-over, and monitoring is compulsory. This paper describes the single-laboratory validation of a previously developed multiplex flow cytometric immunoassay (FCIA) as screening method for coccidiostats in eggs and feed and provides and compares different approaches for the calculation of the cut-off levels which are not described in detail within Commission Decision 2002/657/EC. Comparable results were obtained between the statistical (reference) approach and the rapid approaches. With the most rapid approach, the cut-off levels for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (DNC) and monensin in egg, calculated as percentages of inhibition (%B/B0), were 60, 32, 76, 80 and 84, respectively. In feed, the cut-off levels for narasin/salinomycin, lasalocid, nicarbazin (DNC) and monensin were 70, 64, 72 and 78, respectively, and could not be determined for diclazuril. For all analytes, except for diclazuril in feed, the rate of false positives (false non-compliant) in blank samples was lower than 1 %, and the rate of false negatives (false compliant) at the M(R)Ls was below 5 %. Additionally, very good correlations (r ranging from 0.994 to 0.9994) were observed between two different analysers, a sophisticated flow cytometer (FlexMAP 3D(®)) and a more cost-efficient and transportable planar imaging detector (MAGPIX(®)), hence demonstrating adequate transferability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel multiplexed immunoassay for the analysis of phycotoxins in shellfish samples has been developed. Therefore, a regenerable chemiluminescence (CL) microarray was established which is able to analyze automatically three different phycotoxins (domoic acid (DA), okadaic acid (OA) and saxitoxin (STX)) in parallel on the analysis platform MCR3. As a test format an indirect competitive immunoassay format was applied. These phycotoxins were directly immobilized on an epoxy-activated PEG chip surface. The parallel analysis was enabled by the simultaneous addition of all analytes and specific antibodies on one microarray chip. After the competitive reaction, the CL signal was recorded by a CCD camera. Due to the ability to regenerate the toxin microarray, internal calibrations of phycotoxins in parallel were performed using the same microarray chip, which was suitable for 25 consecutive measurements. For the three target phycotoxins multi-analyte calibration curves were generated. In extracted shellfish matrix, the determined LODs for DA, OA and STX with values of 0.5±0.3 µg L(-1), 1.0±0.6 µg L(-1), and 0.4±0.2 µg L(-1) were slightly lower than in PBS buffer. For determination of toxin recoveries, the observed signal loss in the regeneration was corrected. After applying mathematical corrections spiked shellfish samples were quantified with recoveries for DA, OA, and STX of 86.2%, 102.5%, and 61.6%, respectively, in 20 min. This is the first demonstration of an antibody based phycotoxin microarray.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tetrodotoxin (TTX) is a potent neurotoxin emerging in European waters due to increasing ocean temperatures. Its detection in seafood is currently performed as a consequence of using the Association of Analytical Communities (AOAC) mouse bioassay (MBA) for paralytic shellfish poisoning (PSP) toxins, but TTX is not monitored routinely in Europe. Due to ethical and performance-related issues associated with this bioassay, the European Commission has recently published directives extending procedures that may be used for official PSP control. An AOAC-accredited high-performance liquid chromatography (HPLC) method has now been accepted by the European Union as a first action screening method for PSP toxins to replace the MBA. However, this AOAC HPLC method is not capable of detecting TTX, so this potent toxin would be undetected; thereby, a separate method of analysis is required. Surface plasmon resonance (SPR) optical biosensor technology has been proven as a potential alternative screening method to detect PSP toxins in seafood. The addition of a similar SPR inhibition assay for TTX would complement the PSP assay in removing the MBA. The present report describes the development and single laboratory validation in accordance with AOAC and IUPAC guidelines of an SPR method to be used as a rapid screening tool to detect TTX in the sea snail Charonia lampas lampas, a species which has been implicated in 2008 in the first case of human TTX poisoning in Europe. As no current regulatory limits are set for TTX in Europe, single laboratory validation was undertaken using those for PSP toxins at 800 µg/kg. The decision limit (CCa) was 100 µg/kg, with the detection capability (CCß) found to be =200 µg/kg. Repeatability and reproducibility were assessed at 200, 400, and 800 µg/kg and showed relative standard deviations of 8.3, 3.8, and 5.4 % and 7.8, 8.3, and 3.7 % for both parameters at each level, respectively. At these three respective levels, the recovery of the assay was 112, 98, and 99 %.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The safety of our food is an essential requirement of society. One well-recognised threat is that of chemical contamination of our food, where low-molecular-weight compounds such as biotoxins, drug residues and pesticides are present. Low-cost, rapid screening procedures are sought to discriminate the suspect samples from the population, thus selecting only these to be forwarded for confirmatory analysis. Many biosensor assays have been developed as screening tools in food contaminant analysis, but these tend to be electrochemical, fluorescence or surface plasmon resonance based. An alternative approach is the use of biolayer interferometry, which has become established in drug discovery and life science studies but is only now emerging as a potential tool in the analysis of food contaminants. A biolayer interferometry biosensor was assessed using domoic acid as a model compound. Instrument repeatability was tested by simultaneously producing six calibration curves showing replicate repeatability (n = 2) ranging from 0.1 to 6.5 % CV with individual concentration measurements (n = 12) ranging from 4.3 to 9.3 % CV, giving a calibration curve midpoint of 7.5 ng/ml (2.3 % CV (n = 6)). Reproducibility was assessed by producing three calibration curves on different days, giving a midpoint of 7.5 ng/ml (3.4 %CV (n = 3)). It was further shown, using assay development techniques, that the calibration curve midpoint could be adjusted from 10.4 to 1.9 ng/ml by varying assay parameters before the simultaneous construction of three calibration curves in matrix and buffer. Sensitivity of the assay compared favourably with previously published biosensor data for domoic acid. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multiplex surface plasmon resonance (SPR) biosensor method for the detection of paralytic shellfish poisoning (PSP) toxins, okadaic acid (and analogues) and domoic acid was developed. This method was compared to enzyme-linked immunosorbent assay (ELISA) methods. Seawater samples (n?=?256) from around Europe were collected by the consortia of an EU project MIcroarrays for the Detection of Toxic Algae (MIDTAL) and evaluated using each method. A simple sample preparation procedure was developed which involved lysing and releasing the toxins from the algal cells with glass beads followed by centrifugation and filtering the extract before testing for marine biotoxins by both multi-SPR and ELISA. Method detection limits based on IC20 values for PSP, okadaic acid and domoic acid toxins were 0.82, 0.36 and 1.66 ng/ml, respectively, for the prototype multiplex SPR biosensor. Evaluation by SPR for seawater samples has shown that 47, 59 and 61 % of total seawater samples tested positive (result greater than the IC20) for PSP, okadaic acid (and analogues) and domoic acid toxins, respectively. Toxic samples were received mainly from Spain and Ireland. This work has demonstrated the potential of multiplex analysis for marine biotoxins in algal and seawater samples with results available for 24 samples within a 7 h period for three groups of key marine biotoxins. Multiplex immunological methods could therefore be used as early warning monitoring tools for a variety of marine biotoxins in seawater samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tetrodotoxin (TTX) is one of the most potent marine neurotoxins reported. The global distribution of this toxin is spreading with the European Atlantic coastline now being affected. Climate change and increasing pollution have been suggested as underlying causes for this. In the present study, two different sample preparation techniques were used to extract TTX from Trumpet shells and pufferfish samples. Both extraction procedures (accelerated solvent extraction (ASE) and a simple solvent extraction) were shown to provide good recoveries (80-92%). A UPLC-MS/MS method was developed for the analysis of TTX and validated following the guidelines contained in the Commission Decision 2002/657/EC for chemical contaminant analysis. The performance of this procedure was demonstrated to be fit for purpose. This study is the first report on the use of ASE as a mean for TTX extraction, the use of UPLC-MS/MS for TTX analysis, and the validation of this method for TTX in gastropods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods. © 2013 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As increasing incidences in the occurrence of cylindrospermopsin (CYN) appear, in addition to further research on its toxicological nature, improved rapid methods to detect this toxin are required. Antibody based assays are renowned for their ability to provide rapid, portable, simple to use tests. As yet however there are no publications outlining how an antibody to CYN can be produced. A range of chemical approaches was investigated to synthesise CYN immunogens for antibody production but failed to generate a response. Finally, a modified Mannich reaction for immunogen synthesis was employed to couple the toxin to two carrier proteins. Both protein conjugates were successfully used to raise both polyclonal and monoclonal antibodies of high sensitivity to CYN. These antibodies were characterised employing competitive indirect ELISA and an optical biosensor assay. By ELISA the sensitivity achieved ranged from 27 to 131. pg/mL and by SPR 4.4 to 11.1. ng/mL thus demonstrating that the selection of immunoassay platform is important for the detection level required by the end user for their application. Low cross-reactivity to the much less toxic metabolite deoxyCYN was observed. This is the first reported production of antibodies to this toxin. © 2013 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We simulate and discuss the local electric-field enhancement in a system of a dielectric nanoparticle placed very near to a metallic substrate. We use finite-element numerical simulations in order to understand the field-enhancement mechanism in this dielectric NP-on-mirror system. Under appropriate excitation conditions, the gap between the particle and the substrate becomes a "hot spot", i.e., a region of intense electromagnetic field. We also show how the optical properties of the dielectric NP placed on a metallic substrate affect the plasmonic field enhancement in the nanogap and characterize the confinement in the gap. Our study helps to understand and design systems with dielectric NPs on metallic substrates which can be equally as effective for SERS, fluorescence, and nonlinear phenomena as conventional all plasmonic structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large and rare copy number variants (CNVs) at several loci have been shown to increase risk for schizophrenia. Aiming to discover novel susceptibility CNV loci, we analysed 6,882 cases and 11,255 controls genotyped on Illumina arrays, most of which have not been used for this purpose before. We identified genes enriched for rare exonic CNVs among cases, and then attempted to replicate the findings in an additional 14,568 cases and 15,274 controls. In a combined analysis of all samples, 12 distinct loci were enriched among cases with nominal levels of significance (P500kb), rare CNVs showed a 1.2% excess in cases after excluding known schizophrenia-associated loci, suggesting that additional susceptibility loci exist. However, even larger samples are required for their discovery.