987 resultados para ESR DOSIMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: the assessment of the activity of rheumatoid arthritis and juvenile idiopathic arthritis is made by means of different tools, respectively DAS-28 and JADAS.Objective: To compare DAS-28 and JADAS with scores of 71, 27 and 10 joint counts in juvenile idiopathic arthritis.Method: A secondary analysis of a phase III placebo-controlled trial, testing safety and efficacy of abatacept was conducted in 8 patients with 178 assessment visits. Joint count scores for active and limited joints, physician's and parents'global assessment by 0-10 cm Visual Analog Scale, and erythrocyte sedimentation rate normalized to 0-10 scale, in all visits. The comparison among the activity indices in different observations was made through Anova or adjusted gamma model. The paired observations between DAS-28 and JADAS 71, 27 and 10, respectively, were analyzed by linear regression.Results: There were significant differences among individual measures, except for ESR, in the first four months of biological treatment, when five of the eight patients reached ACR-Pedi 30, with improvement. The indices of DAS-28, JADAS 71, 27 and 10 also showed significant difference during follow-up. Linear regression adjusted model between DAS-28 and JADAS resulted in mathematical formulas for conversion: [DAS-28 = 0.0709 (JADAS 71) + 1.267] (R-2 = 0.49); [DAS-28 = 0.084 (JADAS 27) + 1.7404] (R-2 = 0.47) and [DAS-28 = 0.1129 (JADAS-10) + 1.5748] (R-2 = 0.50).Conclusion: The conversion of scores of DAS-28 and JADAS 71, 27 and 10 for this mathematical model would allow equivalent application of both in adolescents with arthritis. (C) 2014 Elsevier Editora Ltda. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ESR measurements In pressed pellets of doped Poly(3-Methylthiophene)(P3MT) were performed at 10 K and 50 K after cooling the system slowly from room temperature to 110 K, quenching to 77 K and then to 10 K. ESR line asymmetry (A/B) as a function of microwave power was observed and 9.4 GHz conductivity was obtained from Dyson's theory. The data is discussed in terms of Charge-Density Wave (CDW) depinning. At 50 K the threshold electric field is estimated to be less than 1 V/cm. At 10 K a subtle pinning of the CDW was observed around 15 mW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoluminescence intensity as a function of gamma-ray dose of the 325 degreesC peak, in quartz grains extracted from sea sediments and from fluvial aeolic dunes, is studied. It is found that the response curve at low doses has a concavity directed opposite to that of quartz grains extracted from archaeological potteries. To explain this behavior a model is proposed here based on oxygen vacancies and [AlO4/h](0) centers. The experimentally observed ESR intensity of E-I'-centers as a function of radiation dose can also be explained by this model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Head and neck cancer (HNC) is the sixth most common human malignancy worldwide. The main forms of treatment for HNC are surgery, radiotherapy (RT) and chemotherapy (CT). However, the choice of therapy depends on the tumor staging and approaches, which are aimed at organ preservation. Because of systemic RT and CT genotoxicity, one of the important side effects is a secondary cancer that can result from the activity of radiation and antineoplastic drugs on healthy cells. Ionizing radiation can affect the DNA, causing single and double-strand breaks, DNA-protein crosslinks and oxidative damage. The severity of radiotoxicity can be directly associated with the radiation dosimetry and the dose-volume differences. Regarding CT, cisplatin is still the standard protocol for the treatment of squamous cell carcinoma, the most common cancer located in the oral cavity. However, simultaneous treatment with cisplatin, bleomycin and 5-fluorouracil or treatment with paclitaxel and cisplatin are also used. These drugs can interact with the DNA, causing DNA crosslinks, double and single-strand breaks and changes in gene expression. Currently, the late effects of therapy have become a recurring problem, mainly due to the increased survival of HNC patients. Herein, we present an update of the systemic activity of RT and CT for HNC, with a focus on their toxicogenetic and toxicogenomic effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silica gel having a particle size between 0.2 and 0.05 mm and a specific surface area, S BET = 473 m 2 g -1, was chemically modified with benzimidazole. Adsorption isotherms of CuX 2 (X = Cl, Br or ClO 4) from ethanol and acetone solutions were studied at 298 K. The metal is bonded to the surface through the free nitrogen atom of the attached benzimidazole. The average number of ligands co-ordinated to the central metal ion was shown to depend on the solid surface loading by the solute. At low loading the electronic and ESR spectral parameters indicated that the copper ion is in a distorted-tetragonal symmetry field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although they are no longer manufactured, the applicators of 90Sr +90Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been recalibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an 90Sr+90Y betatherapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radiochromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radiochromium films for this type of dosimetry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of gamma radiation on poly{[2,5-bis(3-(N,N-diethylamino)-1-oxapropyl)-1,4-phenylene]-alt-1,4- phenylene} (PPP); poly{[2,5-bis(3-(N,N-diethylammonium bromide)-1-oxapropyl)-1,4-phenylene]-alt-1,4-phenylene} (PPP-Br); and the polymerized dye poly-1-ethyl-2-[3-(1-ethyl-1,3-dihydro-3,3-dimethyl-2H-indol-2-ylidene)-1-propenyl]- 3,3-dimethyl-3H-indolium perchlorate (Poly-CyC) has been investigated. The stability and response of poly [2-methoxy- 5-(2'- ethyl-hexyloxy)-p-phenylenevinylene] (MEH-PPV) in mixed solutions have also been explored. To this end, samples with concentrations ranging from 0.005 to 0.500 mg/mL were irradiated with a 60Co gamma-ray source at room temperature, using doses up to 1 kGy, and the response was analyzed by UV-Vis spectroscopy. The obtained results reinforce the previously proposed mechanism and suggest that the effect depends on specific structural characteristics of the main chain of the polymers. Moreover, the polymerized dyes display interesting dosimetric properties. Additionally, it has been noted that, contrary to what happens in other solvents, MEH-PPV is degraded in bromoform solution. Protective effects have also been observed for bromoform+toluene mixtures (1:1 vol/vol) and solutions containing molecular dyes. - See more at: http://www.eurekaselect.com/117251/article#sthash.gHFnYvJk.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT