983 resultados para Diagnostic Tests
Resumo:
This leaflet gives information on the blood tests that are normally offered and recommended at the first antenatal visit. These tests look for possible health problems that could affect the mother's health and the health of the baby. Only one sample of blood is needed to do all six tests. The tests are done by consent and this leaflet should help pregnant women make their decision.
Resumo:
Taenia solium-taeniasis and cysticercosis were studied in the human and porcine populations of a rural community in the Southern Ecuadorian Andes. From the 1059 inhabitants, 800 serum samples and 958 stool samples could be collected. In addition, 646 from the estimated 1148 pigs were tongue inspected. Circulating antigen was detected by enzyme linked immunosorbent assay (Ag-ELISA) in 2.25% of the human population, whereas intestinal taeniasis was detected in 1.46% by the formalin-ether technique. Following treatment and recovery of tapeworm fragments these were all identified as T. solium. Porcine cysticercosis was diagnosed in 3.56% of the pigs by tongue inspection. In addition, enzyme linked immunoelectrotransfer blot (EITB) was performed on a subset group of 100 humans to confirm the results of the Ag-ELISA. One hundred serum samples from pigs were also analysed by EITB. It appeared that 43 and 74% of humans and pigs had antibodies against T. solium cysticerci, respectively. It is concluded that contrary to the high exposure of the human population to T. solium that is suggested by EITB, the number of active cysticercosis cases, diagnosed by Ag-ELISA, was low, which may indicate endemic stability. The further use of complementary diagnostic methods for a better understanding of the epidemiology of T. solium is suggested.
Resumo:
Strains of enterotoxigenic Escherichia coli (ETEC) are responsible for significant rates of morbidity and mortality among children, particularly in developing countries. The majority of clinical and public health laboratories are capable of isolating and identifying Salmonella, Shigella, Campylobacter, and Escherichia coli O157:H7 from stool samples, but ETEC cannot be identified by routine methods. The method most often used to identify ETEC is polymerase chain reaction for heat-stable and heat-labile enterotoxin genes, and subsequent serotyping, but most clinical and public health laboratories do not have the capacity or resources to perform these tests. In this study, polyclonal rabbit and monoclonal mouse IgG2b antibodies against ETEC heat-labile toxin-I (LT) were characterized and the potential applicability of a capture assay was analyzed. IgG-enriched fractions from rabbit polyclonal and the IgG2b monoclonal antibodies recognized LT in a conformational shape and they were excellent tools for detection of LT-producing strains. These findings indicate that the capture immunoassay could be used as a diagnostic assay of ETEC LT-producing strains in routine diagnosis and in epidemiological studies of diarrhea in developing countries as enzyme linked immunosorbent assay techniques remain as effective and economical choice for the detection of specific pathogen antigens in cultures.
Resumo:
Parental or professional concern regarding an infant/young child's hearing may be identified at any time.� Where such concern is identified, direct referral should be made, irrespective of newborn hearing screening outcomes and with parental agreement.�
Resumo:
The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
Immune-based assays are promising tools to help to formulate diagnosis of active tuberculosis. A multiparameter flow cytometry assay assessing T-cell responses specific to Mycobacterium tuberculosis and the combination of both CD4 and CD8 T-cell responses accurately discriminated between active tuberculosis and latent infection.
Resumo:
PURPOSE: The goal of this study was to compare magnetic resonance enterography (MRE) and video capsule endoscopy (VCE) in suspected small bowel disease. MATERIALS AND METHODS: Nineteen patients with suspected small bowel disease participated in a prospective clinical comparison of MRE versus VCE. Both methods were evaluated separately and in conjunction with respect to a combined diagnostic endpoint based on clinical, laboratory, surgical, and histopathological findings. The Fisher's exact and j tests were used in comparing MRE and VCE. RESULTS: Small bowel pathologies were found in 15 out of 19 patients: Crohn's disease (n= 5), lymphoma (n= 4), lymphangioma (n= 1), adenocarcinoma (n= 1), postradiation enteropathy (n= 1), NSAID-induced enteropathy (n =1), angiodysplasia (n= 1), and small bowel adhesions (n= 1). VCE and MRE separately and in conjunction showed sensitivities of 92.9, 71.4, and 100% and specificities of 80, 60, and 80% (kappa= 0.73 vs. kappa = 0.29; P= 0.31/kappa = 0.85), respectively. In four patients, VCE depicted mucosal pathologies missed by MRE. MRE revealed 19 extraenteric findings in 11 patients as well as small bowel adhesions not detected on VCE (n= 1). CONCLUSION: VCE can readily depict and characterize subtle mucosal lesions missed at MRE, whereas MRE yields additional mural, perienteric, and extraenteric information. Thus, VCE and MRE appear to be complementary methods which, when used in conjunction, may better characterize suspected small bowel disease.
Resumo:
We validated the polymerase chain reaction (PCR) with a composite reference standard in 61 patients clinically suspected of having mucosal leishmaniasis, 36 of which were cases and 25 were non-cases according to this reference standard. Patient classification and test application were carried out independently by two blind observers. One pair of primers was used to amplify a fragment of 120 bp in the conserved region of kDNA and another pair was used to amplify the internal transcript spacers (ITS) rDNA. PCR showed 68.6% (95% CI 59.2-72.6) sensitivity and 92% (95% CI 78.9-97.7) specificity; positive likelihood ratio: 8.6 (95% CI 2.8-31.3) and negative likelihood ratio: 0.3 (95% CI 0.3-0.5), when kDNA molecular target was amplified. The test performed better on sensitivity using this target compared to the ITS rDNA molecular target which showed 40% (95% CI 31.5-42.3) sensitivity and 96% (95% CI 84.1-99.3) specificity; positive likelihood ratio: 10 (95% CI 2.0-58.8) and negative likelihood ratio: 0.6 (95% CI 0.6-0.8). The inter-observer agreement was excellent for both tests. Based upon results obtained and due to low performance of conventional methods for diagnosing mucosal leishmaniasis, we consider PCR with kDNA as molecular target is a useful diagnostic test and the ITS rDNA molecular target is useful when the aim is to identify species.
Resumo:
The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.
Resumo:
Rates of protein synthesis (PS) and turnover are more rapid during the neonatal period than during any other stage of postnatal life. Vitamin A and lactoferrin (Lf) can stimulate PS in neonates. However, newborn calves are vitamin A deficient and have a low Lf status, but plasma vitamin A and Lf levels increase rapidly after ingestion of colostrum. Neonatal calves (n = 6 per group) were fed colostrum or a milk-based formula without or with vitamin A, Lf, or vitamin A plus Lf to study PS in the jejunum and liver. l-[(13)C]Valine was intravenously administered to determine isotopic enrichment of free (nonprotein-bound) Val (AP(Free)) in the protein precursor pool, atom percentage excess (APE) of protein-bound Val, fractional protein synthesis rate (FSR) in the jejunum and liver, and isotopic enrichment of Val in plasma (APE(Pla)) and in the CO(2) of exhaled air (APE(Ex)). The APE, AP(Free), and FSR in the jejunum and liver did not differ significantly among groups. The APE(Ex) increased, whereas APE(Pla) decreased over time, but there were no group differences. Correlations were calculated between FSR(Jej) and histomorphometrical and histochemical data of the jejunum, and between FSR(Liv) and blood metabolites. There were negative correlations between FSR(Liv) and plasma albumin concentrations and between FSR(Jej) and the ratio of villus height:crypt depth, and there was a positive correlation between FSR(Jej) and small intestinal cell proliferation in crypts. Hence, there were no effects of vitamin A and Lf and no interactions between vitamin A and Lf on intestinal and hepatic PS. However, FSR(Jej) was correlated with histomorphometrical traits of the jejunum and FSR(Liv) was correlated with plasma albumin concentrations.
Resumo:
The first aim of this study was to assess the diagnostic performance of presepsin (sCD14-ST) in postmortem serum from femoral blood compared to procalcitonin (PCT) to detect sepsis-related fatalities. The second aim was to compare sCD14-ST levels found in postmortem serum to the values in pericardial fluid to investigate the usefulness of the latter as an alternative biological fluid. Two study groups were formed, a sepsis-related fatalities group and a control group. Radiology (unenhanced CT scans and postmortem angiographies), autopsies, histology, neuropathology, and toxicology as well as other postmortem biochemistry investigations were performed in all cases. Microbiological investigations on right cardiac blood were carried out exclusively in septic cases. The results of this study indicated that postmortem serum PCT and sCD14-ST levels, individually considered, allowed septic cases to be identified. Even though increases in both PCT and sCD14-ST concentrations were observed in the control cases, coherent PCT and sCD14-ST results in cases with suspected sepsis allowed the diagnosis to be confirmed. Conversely, no relevant correlation was identified between postmortem serum and pericardial fluid sCD14-ST levels in either the septic or control groups.
Resumo:
Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.
Resumo:
We report the case of a 58-year-old diabetic man admitted to the hospital in a comatose state due to medicamentous hypoglycemia in a context of hypovolemic acute renal failure. Hypovolemia was due to hemoperitoneum in a alcoholic patient with cirrhotic hepatic failure. CT-scan and arterial angiographies revealed a voluminous isolated hepatic mass with active bleeding suggesting the diagnosis of spontaneous bleeding from a hepatocellular carcinoma. The hemorrhage resolved after selective arterial embolization, but the patient died two weeks later from an infectious cause. The differential diagnosis of a spontaneous hemoperitoneum and possibilities of treatment in the case of ruptured hepatocellular carcinoma are discussed.